No Image Found   

Check List Report

Jhumritilaiya Nagar Parishad

Version Number: 1.0.42  
Version Date: 29/04/2019 
Report Generated On: 18-10-2019 
 

[-] Collapse All


General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictKODERMA
AuthorityJHUMRITILAIYA NAGAR PARISHAD
Inward_NoJNP/BP/0054/W22/2019
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentNew
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillageGomo
Taluka25
Architect Details
Architect NameRAJIB KUMAR SAHA
License No.JNP/ARC/0004/2017
Architect AddressC/O AJANTA SWEETS, NEAR RAILWAY STATION, JHUMRI TELAIYA
Architect EmailIDPRITHVIRAJSAHA@GMAIL.COM
Architect Mobile No9709218244
Plot Details
Plot Use Medical
Plot SubUse Dispensary
PlotNearbyReligiousStructure NA
Plot/SubPlot No5666
North -
South -
East -
West -
Owner's Details
NameSMT. PINKI KUMARI
AddressBHAGWAT CLINIC, RANCHI PATNA ROAD
Email IDdr_akdinkar@rediffmail.com
Mobile No9431361946
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 670.44
2 Plot area as per Document by Applicant 670.44
3 Physical area measured at site 670.44
4 Area as per Site Visit (Site Visit Report) 670.44
5Area as per Drawing 670.44

Area of Plot Considered : 670.44

Plot area provided in drawing shall not be more than Plot area as per Document.
[-] Table 2b
Proposal Detail :
UnitMeters
Development Detail :
PlotPLOT
Plot OccupancyMedical
Plot SubUse Dispensary
Building StructureNon-Highrise
Building TypeSingle Detached House
Gross Plot Area 670.44
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 670.44
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 565.31
Deductions for Balance Plot Area (from Gross Plot Area)
- Common Plot 105.13
105.13
Balance Plot Area 565.31

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 60.00 % ) 402.26
Proposed Coverage Area ( 39.69 % ) 266.10
Total Prop. Coverage Area ( 39.69 % ) 266.10
Balance coverage area ( 20.31 % ) 136.16
FAR CHECK
Perm. FAR Area ( 2.00 ) 1340.88
Total Perm. FAR area 1340.88
Residential FAR 215.12
Special FAR 1101.31
Proposed FAR Area 1336.50
Total Proposed FAR Area 1336.50
Consumed FAR (Factor) 1.99
Balance FAR Area 4.38
BUA CHECK
Total Proposed BuiltUp Area 1643.43


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Up to 50 meter -
Existing Road Width 9.14 9.14
Proposed Road Width as per Master Plan 9.14 -
Road Widening Width 0.1 -
Plot size (as per measurement) 670.44 670.44
[-] Extra Land Area Checks
Name Area Status
Reqd Prop
Extra Land - 0.00 OK

     Extra Land Area Details
Name Description Unit Reqd Perm Proposed Status
Extra Land Area Details Extra Land Area - - 0.00 OK

     Plot Related Details
Name Description Unit Reqd Perm Proposed Status
PLOT Plot Area Sq.Mt. - - 670.44 OK
Plot Width Mt. - - 20.09 OK
Plot Depth Mt. - - 33.37 OK
Access Width Mt. 9.00 - 9.14 OK
Plot Frontage Mt. - - 16.87 OK
Coverage Area Sq.Mt. - 402.26 266.10 OK
FAR Area Sq.Mt. - 1340.88 1336.50 OK
Consumed FAR Sq.Mt. - 2.00 1.99 OK
Common Plot Checks Common Plot - Total Area Sq.Mt. 33.52 105.13 OK
Common Plot Tree Cover (Plantation) - Minimum Area Sq.Mt. - 105.13 OK
Tree Cover (Plantation) - Coverage Area Sq.Mt. - - OK
Tree Cover (Plantation) - Width Mt. - 4.51 OK
Tree Cover (Plantation) - Angle Degree - 90.00 OK
Tree Cover (Plantation) - Access Mt. - OK
Tree Tree - Nos Of Trees No. 4 5 OK
Car In Area Sq.Mt. - - 62.50 OK
Total Car In Area Sq.Mt. 25.00 - 62.50 OK
Visitor's Car Parking In Area Sq.Mt. - - 12.50 OK
Total Visitor Parking In Area Sq.Mt. 12.50 - 12.50 OK
TwoWheeler In Area Sq.Mt. - - 50.00 OK
Total TwoWheeler In Area Sq.Mt. 2.00 - 50.00 OK
Other Parking In Area Sq.Mt. - - 124.56 OK
J-1 (K) Front Margin... 9.14M WIDE MAIN ROAD Mt. 7.00 - 7.01 OK
Rear Margin Mt. 4.50 - 4.51 OK
Side1 Margin Mt. 2.50 - 2.50 OK
Side2 Margin Mt. 2.50 - 2.50 OK
J-1 (K) Basement Front Margin... 9.14M WIDE MAIN ROAD Mt. 3.00 - 5.01 OK
Basement Rear Margin Mt. 3.00 - 4.51 OK
Basement Side1 Margin Mt. 2.50 - 2.50 OK
Basement Side2 Margin Mt. 2.50 - 2.50 OK

     Building Related Details
Name Description Unit Reqd Perm Proposed Status
J (K) Height Mt. 20.72 14.26 OK
J (K) Fourth Floor - Height Mt. 2.75 - 2.85 OK
Fourth Floor - Clear Height Mt. 2.75 - 2.75 OK
Fourth Floor - Beam Clear Height Mt. 2.40 - 2.55 OK
Third Floor - Height Mt. 2.75 - 2.85 OK
Third Floor - Clear Height Mt. 2.75 - 2.75 OK
Third Floor - Beam Clear Height Mt. 2.40 - 2.55 OK
Second Floor - Height Mt. 2.75 - 2.85 OK
Second Floor - Clear Height Mt. 2.75 - 2.75 OK
Second Floor - Beam Clear Height Mt. 2.40 - 2.55 OK
First Floor - Height Mt. 2.75 - 2.85 OK
First Floor - Clear Height Mt. 2.75 - 2.75 OK
First Floor - Beam Clear Height Mt. 2.40 - 2.55 OK
Ground Floor - Height Mt. 2.75 - 2.85 OK
Ground Floor - Clear Height Mt. 2.75 - 2.75 OK
Ground Floor - Beam Clear Height Mt. 2.40 - 2.55 OK
Basement Floor - Height Mt. 2.40 - 2.74 OK
Basement Floor - Clear Height Mt. 2.40 - 2.64 OK
Basement Floor - Beam Clear Height Mt. 2.10 - 2.44 OK
J (K) Terrace Floor - Height Mt. 1.00 1.20 1.07 OK
J (K) Basement Floor - Height Below GL Mt. - 1.53 OK
Basement Floor - Area Sq.Mt. - 294.63 OK
Basement Floor - Ventilation Area (Sq.mt.) Sq.Mt. - - OK
J (K) Area Sq.Mt. - 294.63 OK
Status - OK
Total Area Sq.Mt. - 294.63 OK
J (K) No. of Basement Floor No. 1 1 OK
J (K) No. of Floors No. G + 6 5 OK
No. of Tenements No. - 9 OK
J (K) FIRST FLOOR PLAN - Passage Name - OK
FIRST FLOOR PLAN - Width Mt. 1.00 2.02 OK
FIRST FLOOR PLAN - Length Mt. - 18.80 OK
GROUND FLOOR PLAN - Passage Name - OK
GROUND FLOOR PLAN - Width Mt. 1.00 2.06 OK
GROUND FLOOR PLAN - Length Mt. - 23.75 OK
THIRD FLOOR PLAN - Passage Name - OK
THIRD FLOOR PLAN - Width Mt. 1.00 2.02 OK
THIRD FLOOR PLAN - Length Mt. - 18.80 OK
SECOND FLOOR PLAN - Passage Name - OK
SECOND FLOOR PLAN - Width Mt. 1.00 2.02 OK
SECOND FLOOR PLAN - Length Mt. - 18.80 OK
J (K) Number Of Lift(s) No. 1 1 OK
J (K) FIRST FLOOR PLAN - STRETCHER LIFT for 15 Person - Width Mt. 1.80 2.59 OK
FIRST FLOOR PLAN - STRETCHER LIFT for 15 Person - Depth Mt. 3.00 3.13 OK
GROUND FLOOR PLAN - STRETCHER LIFT for 15 Person - Width Mt. 1.80 2.59 OK
GROUND FLOOR PLAN - STRETCHER LIFT for 15 Person - Depth Mt. 3.00 3.13 OK
BASEMENT FLOOR PLAN - STRETCHER LIFT for 15 Person - Width Mt. 1.80 2.59 OK
BASEMENT FLOOR PLAN - STRETCHER LIFT for 15 Person - Depth Mt. 3.00 3.13 OK
THIRD FLOOR PLAN - STRETCHER LIFT for 15 Person - Width Mt. 1.80 2.59 OK
THIRD FLOOR PLAN - STRETCHER LIFT for 15 Person - Depth Mt. 3.00 3.13 OK
SECOND FLOOR PLAN - STRETCHER LIFT for 15 Person - Width Mt. 1.80 2.59 OK
SECOND FLOOR PLAN - STRETCHER LIFT for 15 Person - Depth Mt. 3.00 3.13 OK
FOURTH FLOOR PLAN - STRETCHER LIFT for 15 Person - Width Mt. 1.80 2.59 OK
FOURTH FLOOR PLAN - STRETCHER LIFT for 15 Person - Depth Mt. 3.00 3.13 OK
TERRACE FLOOR PLAN - Lift Machine Room - Width Mt. 1.70 2.59 OK
TERRACE FLOOR PLAN - Lift Machine Room - Depth Mt. 1.90 3.13 OK
FIRST FLOOR PLAN Staircase -3FL - Flight Width Mt. 0.900 1.524 OK
Staircase -3FL - Tread Width Mt. 0.250 0.305 OK
Staircase -3FL - Riser Height Mt. 0.200 0.092 OK
Staircase -3FL - Riser No. On Flight No. - 9 OK
Staircase -3FL - Cabin Ht. Mt. - - - OK
GROUND FLOOR PLAN Staircase -3FL - Flight Width Mt. 0.900 1.524 OK
Staircase -3FL - Tread Width Mt. 0.250 0.305 OK
Staircase -3FL - Riser Height Mt. 0.200 0.092 OK
Staircase -3FL - Riser No. On Flight No. - 9 OK
Staircase -3FL - Cabin Ht. Mt. - - - OK
BASEMENT FLOOR PLAN Staircase -3FL - Flight Width Mt. 0.900 1.524 OK
Staircase -3FL - Tread Width Mt. 0.250 0.305 OK
Staircase -3FL - Riser Height Mt. 0.200 - OK
Staircase -3FL - Riser No. On Flight No. - - OK
Staircase -3FL - Cabin Ht. Mt. - - - OK
THIRD FLOOR PLAN Staircase -3FL - Flight Width Mt. 0.900 1.524 OK
Staircase -3FL - Tread Width Mt. 0.250 0.305 OK
Staircase -3FL - Riser Height Mt. 0.200 0.092 OK
Staircase -3FL - Riser No. On Flight No. - 9 OK
Staircase -3FL - Cabin Ht. Mt. - - - OK
SECOND FLOOR PLAN Staircase -3FL - Flight Width Mt. 0.900 1.524 OK
Staircase -3FL - Tread Width Mt. 0.250 0.305 OK
Staircase -3FL - Riser Height Mt. 0.200 0.092 OK
Staircase -3FL - Riser No. On Flight No. - 9 OK
Staircase -3FL - Cabin Ht. Mt. - - - OK
FOURTH FLOOR PLAN Staircase -3FL - Flight Width Mt. 0.900 1.524 OK
Staircase -3FL - Tread Width Mt. 0.250 0.305 OK
Staircase -3FL - Riser Height Mt. 0.200 0.092 OK
Staircase -3FL - Riser No. On Flight No. - 9 OK
Staircase -3FL - Cabin Ht. Mt. - - - OK
TERRACE FLOOR PLAN Staircase -3FL - Flight Width Mt. - 1.524 OK
Staircase -3FL - Tread Width Mt. - 0.305 OK
Staircase -3FL - Riser Height Mt. - - OK
Staircase -3FL - Riser No. On Flight No. - - OK
Staircase -3FL - Cabin Ht. Mt. - - 2.781 OK
Sewage Treatment Plant Area Sq.Mt. - - 9.73 OK
Width Mt. - - 1.98 OK
Depth Mt. - - 4.92 OK
Height Mt. - - - OK
RAIN WATER HARVESTING Area Sq.Mt. - - 0.93 OK
Width Mt. - - 0.89 OK
Depth Mt. - - 1.05 OK
Height Mt. - - - OK
Overhead WaterTank Area Sq.Mt. - - 20.07 OK
Width Mt. - - 3.66 OK
Depth Mt. - - 5.49 OK
Height Mt. - - 1.41 OK
ENT.GATE Area Sq.Mt. - - 0.67 OK
Width Mt. - - 0.17 OK
Depth Mt. - - 4.04 OK
Height Mt. - - - OK
SOLAR HEATING SYSTEM Area Sq.Mt. - - 9.71 OK
Width Mt. - - 2.90 OK
Depth Mt. - - 3.35 OK
Height Mt. - - - OK
Generator Room Area Sq.Mt. - - 19.55 OK
Width Mt. - - 2.90 OK
Depth Mt. - - 6.75 OK
Height Mt. - - - OK
J (K) Rain Water Harvesting - No No. 1 - 1 OK
Solar Water Heating System - No No. 1 - 1 OK
Entrance Gate - No No. 1 - 1 OK
PLOT 10.76 mt. long 1.53 mt. High 3.66 mt. Wide Car Ramp - Width Mt. 3.00 3.66 OK
10.76 mt. long 1.53 mt. High 3.66 mt. Wide Car Ramp - Depth Mt. 1.00 1.53 OK
10.76 mt. long 1.53 mt. High 3.66 mt. Wide Car Ramp - Slope Ratio 1.00 : 8.00 1.00 : 20.00 01 : 08 OK
Ramp No. J (K) - BASEMENT FLOOR PLAN - No. No. 1 1 OK
   
    All Rooms are as per Rule in Room Checking




[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use
Plot Width No rule provided for Min. Plot size for proposed Use
Plot Depth No rule provided for Min. Plot size for proposed Use
Access Width The minimum width of abutting road for Institutional, administrative, assembly, industrial and other Nonresidential and commercial activities shall be 9.0 mt.{As per Rule no. 34.5 and modified as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
Plot Frontage No rule provided for Min. Plot size for proposed Use
FAR Area (1) In Old Area, for Non-Residential Building on abutting roadwidth 9.10 (30 ft.) to 12.20 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15}
(2) For Jhumritilaiya Nagar Parishad, Max. 2.0 permissible FAR may be permitted for Commercial or Mercantile type Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Non-Residential Building on abutting roadwidth 9.10 (30 ft.) to 12.20 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15}
(2) For Jhumritilaiya Nagar Parishad, Max. 2.0 permissible FAR may be permitted for Commercial or Mercantile type Use {As per Annexure III}
Common Plot Area In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
Common Plot (1) In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
(2) ;
Tree Number 4-8 Trees shall be required for the Plot area above 250.0 and upto 1000.0 sq.mt. (As per Rule No. 20.1.6)
Margin Rule For Non-highrise Commercial Building upto 16.4 mt. Ht. having Plot Depth 33-39 mt. and Plot width 15-21 mt., Margin required in Front shall be 7.0 mt., Rear 4.5 mt. and 2.5 mt. shall be provided on both side. {As per Rule No. 36 Table 10 & 11}
Basement Margin Rule In case of apartment/ group housing/commercial building and basements may be allowed to be constructed under the entire plot area leaving mini. 3 mt. space from the boundary of the premises {As per Rule No. 48}
Building Level
Building Height For old area, on Road width 9.10-12.20 mt., Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 23.10 mt. {As per Rule No. 39.1 Table 15}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(3) o Every basement shall be in every part at least 2.4 m. in height from the floor to the soffit of the roof slab or ceiling and mini. Of 2.1 mr. below the soffit of beams {As per Rule No. 48}
Parapet Height Parapet walls and handrails provided on the edges of roof terraces, balcony, verandah, etc shall not be less than 1.0 m and not more than 1.2 m in height from the finished floor level {As per Rule No. 42.5}
Below GL Floor Height ,
Basement Floor No. Individual residential and small commercial buildings, plot size upto minimum 750 Sq. Meter may have one basement {As per Rule No. 48}
Floor Number For old area location,on Road width 9.1-12.20 mt. only G+6 floors shall be allowed {As per Rule No. 39.1 Table 15}
Passage No exit doorway shall be less than 1.00 m. in width. {As per Rule No.43.4.2} ;
Lift Count (1) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(2) For Non-Residential Building, Minimum number of lifts to be 2 for all non-residential building above ground + 2 and the minimum capacity shall be 6 persons per floor. {As per Rule No. 49.2.3 and as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
Lift (1) The area of lift well shall not be counted for F.A.R calculation)
(2) The lift shall have a minimum width 1.8 mt. and minimum depth 3.0 mt.{As per clause no 4 and page no. 14 NBC }
(3) The area of lift well at one floor only (not the sum of total area of lift well at every floor) shall be counted for F.A.R calculation)
(4) The lift shall have a minimum width 1.8 mt. and minimum depth 3.0 mt.{As per clause no 4 and page no. 14 NBC }
(5) -
StairCase (1) Width of Winding staircase shall be mini. 0.90 mt.,Maximum rise 0.20 mt. & Minimum tread 0.25 mt. & Cabin Height 2.1 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) No Rule Defined
(4) ; No Rule Defined
Ramp For parking spaces in basements and upper storey of parking floors, at least two ramps of minimum of 3.00m width if it is strait and 3.6 width if it is curved at any point, or one ramp of minimum 4.5 m width and with minimum slope gradient of 1:8 for depth up to 1.8m and 1:10 for more than 1.8m depth shall be provided. In the case of Hospitals, the slope of ramp shall not be greater than 1:20 {As per Rule No. 41.8} ;
Ramp No. For parking spaces in basements and upper storey of parking floors, if car parking is less then 40 one ramp of minimum of 3.30m width if it is straight and 4.50m width if it is curved shall be provided
Plot / Building Level
Accessory Use (1) -
(2) No need to check distance from Building Sewage Treatment Plant
(3) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(4) No need to check distance from Building RAIN WATER HARVESTING
(5) -
(6) No need to check distance from Building Overhead WaterTank
(7) No need to check distance from Building ENT.GATE
(8) -
(9) No need to check distance from Building SOLAR HEATING SYSTEM
(10) Electric cabin or substation of maximum size of 4 sq.m. with minimum width or diameter of 2 m
(11) No need to check distance from Building Generator Room
Accessory Use Number (1) Provision of rainwater harvesting shall be mandatory for 300 sqm. and above size of plots-The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area Rain Water Harvesting
(2) For Hospitals and Nursing Home type of Building, Provisions of Solar Water Heating System shall be done. Solar Water Heating System
(3) In case of buildings with a height of 15.0 meters and above or ground coverage more than 500 sqm., the main entrance to the premise shall not be less than 5 (five) meters i n width in order to allow easy access to fire engine Entrance Gate