No Image Found   

Detail Scrutiny Report

Jhumritilaiya Nagar Parishad

Version Number: 1.0.61  
Version Date: 16/10/2020 
Report Generated On: 11-01-2022 
 
[-] Collapse All


General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictKODERMA
AuthorityJHUMRITILAIYA NAGAR PARISHAD
Inward_NoJNP/BP/0075/W05/2021
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentNew
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillageAsana
Taluka25
Architect Details
Architect NameMD SHOAIB ALAM
License No.JNP/ENG/0001/2017
Architect AddressGUMO, NEAR MICANITE , PO - JHUMRI TELAIYA , DISTT - KODERMA
Architect EmailIDalam.construction@gmail.com
Architect Mobile No9934190015
Plot Details
Plot Use Residential
Plot SubUse Bungalow/ Dwelling / Non Apartment
PlotNearbyReligiousStructure NA
Plot/SubPlot No2070
NorthPlot No. - AWADESH SETH
SouthPlot No. - RAJESH SAW
EastPlot No. - SAM,U PRASAD MEHTA
WestRoad Width - 3.65M WIDE KATCHA RASTA
Owner's Details
NameSRI SANTOSH KUMAR
AddressJHUMRI TELAIYA
Email IDsantosh235ps@gmail.com
Mobile No7004872402
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Plot area as per Document by Applicant 147.21
2 Physical area measured at site 147.00
3 Area as per Site Visit (Site Visit Report) 147.21
4Area as per Drawing 147.81

Area of Plot Considered : 147.00

Plot area provided in drawing shall not be more than Plot area as per Document.
[-] Table 2b
Proposal Detail :
UnitMeters
Development Detail :
PlotPLOT
Plot OccupancyResidential
Plot SubUse Bungalow/ Dwelling / Non Apartment
Building StructureNon-Highrise
Building TypeNA
Gross Plot Area 147.00
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 147.00
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 131.89
Deductions for Balance Plot Area (from Gross Plot Area)
- Common Plot 15.11
15.11
Balance Plot Area 131.89

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 70.00 % ) 102.90
Proposed Coverage Area ( 50.90 % ) 74.82
Total Prop. Coverage Area ( 50.9 % ) 74.82
Balance coverage area ( 19.10 % ) 28.08
FAR CHECK
Perm. FAR Area ( 1.50 ) 220.50
Total Perm. FAR area 220.50
Residential FAR 149.64
Proposed FAR Area 156.11
Substructure Area Add in FAR (Layout Lvl) 5.61
Total Proposed FAR Area 156.11
Consumed FAR (Factor) 1.06
Balance FAR Area 58.78
BUA CHECK
Total Proposed BuiltUp Area 224.46


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Up to 50 meter -
Existing Road Width 3.65 3.65
Proposed Road Width as per Master Plan 3.65 -
Road Widening Width 0.1 -
Plot size (as per measurement) 147.21 147.81


[-] Plot Level Checking (Table 3)
   
[-] Common Plot Checks (Table 3b)
Name Total Area Status
Reqd Prop
Common Plot 7.35 15.11 OK


[-] Common Plot Checks (Table 3b)
Name Minimum Area Coverage Area Width Angle Access Status
Reqd Prop Perm Prop Reqd Prop Reqd Prop
Tree Cover (Plantation) - 15.11 0.00 0.00 - 2.43 - 90.00 No Access Provided OK


   
   
[-] Tree Details (Table 3g)
Name Nos Of Trees Status
Reqd Prop
Tree 2 3 OK
   
   
   
   
   


[-] Building Details (Table 4)
   
[-] Building USE/SUBUSE Details Building USE/SUBUSE Details
Building Name Building Use Building SubUse Building Structure
A (SRI SANTOSH KUMAR) Residential Bungalow/ Dwelling / Non Apartment Non-Highrise
   
   
   
[-] Height Details (4a)



[-] Total Height (Table 4a-1)
Building Height Height (From GL) Height (From Street LVL) Status
Perm Prop
A (SRI SANTOSH KUMAR) 8.63 8.55 8.55 8.55 OK


   
   
[-] Floor Height Check (Table 4a-2)
Building Name Floor Name Height Clear Height Beam Clear Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
A (SRI SANTOSH KUMAR) Second Floor 2.75 - 2.85 2.75 - 2.75 2.40 - 2.48 OK
First Floor 2.75 - 2.85 2.75 - 2.75 2.40 - 2.44 OK
Ground Floor 2.75 - 2.85 2.75 - 2.75 2.40 - 2.48 OK
Plinth 0.45 - 0.60 - - 0.60 - - 0.60 OK


[-] Parapet Height Check (Table 4a-2.1)
Building Name Floor Name Height Status
Reqd Perm Prop
A (SRI SANTOSH KUMAR) Terrace Floor - - 1.00 OK
   
   
   
[-] Floor Number Check (Table 4a-4)
Building Name No. of Floors No. of Tenements Status
Perm Prop Perm Prop
A (SRI SANTOSH KUMAR) G + 2 3 - 2 OK

 
   
    [-] Coverage Check (Table 4b)
Permissible Proposed Status
102.90 74.82 OK
70% 50.9%

[-] Individual Coverage Check
Coverage Area Perm. Prop.
  A-1 (SRI SANTOSH KUMAR) - 74.82
  Total Prop. Coverage Area - 74.82
  Total Coverage Area 102.90 74.82

[-] FAR & Tenement Details (Table 4c-1)
Building No. of Same Bldg Total Built Up Area (Sq.mt.) Deductions (Area in Sq.mt.) Proposed FAR Area (Sq.mt.) Add Area In FAR (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
Parking Resi. Stair
A (SRI SANTOSH KUMAR) 1 224.46 68.36 149.64 6.46 156.10 156.10 02
Grand Total : 1 224.46 68.36 149.64 6.46 156.10 156.10 02


[-] Buildingwise Floor FAR Details
Floor Name Building Name Total
A (SRI SANTOSH KUMAR)
Proposed Built Up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Total Proposed Built Up Area (Sq.mt.) Total FAR Area (Sq.mt.)
Ground Floor 74.82 6.46 74.82 6.46
First Floor 74.82 74.82 74.82 74.82
Second Floor 74.82 74.82 74.82 74.82
Terrace Floor 0.00 0.00 0.00 0.00
Total : 224.46 156.10 224.46 156.10


[-] UnitBUA Table for Building :A (SRI SANTOSH KUMAR)
UnitBUA CALCULATION
FLOOR Name UnitBUA Type UnitBUA Area Carpet Area No. of Rooms No. of Tenement
TYPICAL - 1& 2 FLOOR PLAN SPLIT FLAT A FLAT 62.28 59.07 7 2
Total: - - 124.56 118.15 14 2


[-] Building :A (SRI SANTOSH KUMAR)
Floor Name Total Built Up Area (Sq.mt.) Deductions (Area in Sq.mt.) Proposed FAR Area (Sq.mt.) Add Area In FAR (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
Parking Resi. Stair
Ground Floor 74.82 68.36 0.00 6.46 6.46 6.46 00
First Floor 74.82 0.00 74.82 0.00 74.82 74.82 01
Second Floor 74.82 0.00 74.82 0.00 74.82 74.82 01
Terrace Floor 0.00 0.00 0.00 0.00 0.00 0.00 00
Total : 224.46 68.36 149.64 6.46 156.10 156.10 02
Total Number of Same Buildings : 1
Total : 224.46 68.36 149.64 6.46 156.10 156.10 02
[-] Table 4c-2

  FAR Area
Building FAR Area:161.72
Existing FAR Area :0.00
Perm.
220.50
Prop.
161.72
Status
OK




[-] Margin Checks (Table 5)
   
[-] Plot Margin (Table 5a)
Building / Wing Road Name Front Side Rear Side Side1 Side2 Status
Reqd. Prop. Reqd. Prop. Reqd. Prop. Reqd. Prop.
A-1 (SRI SANTOSH KUMAR) 3.65M WIDE ROAD 2.00 3.15 1.50 1.50 0.90 0.90 0.90 0.90 OK






[-] Inner Building Details (Table 6)
   

No OTS/Duct/VShaft/Balcony/Passage/Lift/Tenements Found.
   


[-] Parking Details (Table 7)
   
[-] Required Parking(Table 7a)
Building Name Type SubUse Area (Sq.mt.) Units Car Visitors Car
Reqd. Prop. Reqd./Unit Reqd. Prop. Reqd./Unit Reqd. Prop.
A (SRI SANTOSH KUMAR) Residential Bungalow/ Dwelling / Non Apartment > 0 1 2.00 1 2 - - - -
> 0 1 2.00 - - - 1 1 -
Total : - - - - 2 2 - 1 1

[-] Parking Check (Table 7b)
Vehicle Type Reqd. Prop. Status
No. Area No. Area
Car - - 2 25.00 OK
Total Car 2 25.00 2 25.00 OK
Visitor's Car Parking - - 1 12.50 OK
Total Visitor Parking 1 12.50 1 12.50 OK
Other Parking - - - 43.36 OK
Total 37.50 80.86 OK

Individual Parking Checks (Table 7c)
Dimensions and Area for all Vehicle(s) are as per the Rules

[-] Driveway Parking Checks (Table 7d)
Building/Plot Name Floor Name Driveway Name Width Status
Reqd Perm Prop
A (SRI SANTOSH KUMAR) GROUND FLOOR PLAN DRIVEWAY 3.60 - 3.75 OK

   


[-] Exemption Details (Table 8)
   


Not Required to Check StairCase Number Rule.


[-] Staircase Checks (Table 8a-1)


[-] For Building :A (SRI SANTOSH KUMAR)
Floor Name StairCase Name Flight Width Tread Width Riser Height Riser No. On Flight Cabin Ht. Status
Reqd Prop Reqd Prop Perm Prop Perm Prop Reqd Perm Prop
GROUND FLOOR PLAN STAIRCASE 0.900 1.060 0.250 0.250 0.200 0.178 - 8 - - 0.000 OK
TYPICAL - 1& 2 FLOOR PLAN STAIRCASE 0.900 1.060 0.250 0.250 0.200 0.178 - 8 - - 0.000 OK
TERRACE FLOOR PLAN STAIRCASE - 1.060 - 0.250 - 0.000 - 0 - - 2.500 OK

   
   
   
[-] Accessory Use Check (Table 8d)
Accessory Use Name Area Width Depth Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
Toilet - 5.00 5.61 - - 2.97 - - 3.24 - - 0.00 Failed
SUMP TANK - - 5.24 - - 1.36 - - 3.99 - - 0.00 OK
RAIN WATER HARVESTING - - 5.24 - - 1.36 - - 3.99 - - 0.00 OK





[-] Accessory Use No. Checks
Building Name Accessory Use Name No Status
Reqd Perm Prop
A (SRI SANTOSH KUMAR) Rain Water Harvesting 1 - 1 OK
   
   


[-] Floor Details (Table 9)
   

[-] Building:A (SRI SANTOSH KUMAR)


[-] Floor:GROUND FLOOR PLAN



No Room Found.


[-] Floor:TYPICAL - 1& 2 FLOOR PLAN



All Dimensions and Area of all the Rooms on this Floor are as per the Rules.


   


[-] Summary (Table 10)
   
Name Perm./Reqd. Proposed Status
  Plot Area - 147.00 OK
  Plot Width - 12.76 OK
  Plot Depth - 11.58 OK
  Access Width - 3.65 OK
  Plot Frontage - 13.79 OK
  Coverage Area 102.90 74.82 OK
  FAR Area
Bldg. FAR Area : 161.72
Sanctioned FAR Area :0.00
220.50 161.72 OK





[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Width No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Depth No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Access Width The minimum width of abutting road for any Building shall be with respect to Length of Road {As per Rule No. 34 Table No.6}
Plot Frontage No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
FAR Area (1) In Old Area, for Residential Building on abutting roadwidth 3.60 (12 ft.) to 4.80 mt., the Floor Area Ratio-FAR shall be 1.5 {As per Rule No.39, Table 15}
(2) For Jhumritilaiya Nagar Parishad, Max. 2.0 permissible FAR may be permitted for Residential Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Residential Building on abutting roadwidth 3.60 (12 ft.) to 4.80 mt., the Floor Area Ratio-FAR shall be 1.5 {As per Rule No.39, Table 15}
(2) For Jhumritilaiya Nagar Parishad, Max. 2.0 permissible FAR may be permitted for Residential Use {As per Annexure III}
Common Plot Area In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
Common Plot (1) In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
(2) ;
Tree Number 2-4 Trees shall be required for the Plot area upto 250.0 sq.mt. (As per Rule No. 20.1.6)
DriveWay Rule For Plor area upto 2000 sq.mt., the minimum width or driveways should not be less than 3.60 mt. {As per Rule No. 41.2 and modified as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
Margin Rule For Non-highrise Residential Building upto 10.0 mt. Ht. having Plot Depth 10-15 mt. and Plot width 10-15 mt., Margin required in Front shall be 2.0 mt., Rear 1.5 mt. and 0.9 mt. shall be provided on both side. {As per Rule No. 36 (Table 8 & 9)}
Building Level
Building Height For old area, on Road width 3.6-4.8 mt., Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 10.0 mt. {As per Rule No. 39.1 Table 15}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(3) The plinth or any part of a building shall be so located with respect to the surrounding ground level that adequate drainage of the site is assured. The height of the plinth (except in case of stilted parking) shall be not less than 0.45 mt. from the surrounding ground level {As per Rule No. 42.10}
Parapet Height Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
Floor Number For old area location,on Road width 3.6-4.8 mt. only G+2 floors shall be allowed {As per Rule No. 39.1 Table 15}
StairCase (1) Width of Winding staircase shall be mini. 0.90 mt.,Maximum rise 0.20 mt. & Minimum tread 0.25 mt. & Cabin Height 2.1 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) No Rule Defined
(4) ; No Rule Defined
Plot / Building Level
Accessory Use (1) Common toilet of maximum size of 5 sq.mt shall be taken Free from FAR
(2) No need to check distance from Building Toilet
(3) -
(4) No need to check distance from Building SUMP TANK
(5) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(6) No need to check distance from Building RAIN WATER HARVESTING
Accessory Use Number Provision of Rain Water Harvesting shall be mandatory for any use {Updated as per JBBL, Amendment VIII dated 16/03/2021} Rain Water Harvesting
Building Level (Rooms)