No Image Found   

Detail Scrutiny Report

Jhumritilaiya Nagar Parishad

Version Number: 1.0.61  
Version Date: 16/10/2020 
Report Generated On: 02-11-2021 
 
[-] Collapse All


General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictKODERMA
AuthorityJHUMRITILAIYA NAGAR PARISHAD
Inward_NoJNP/BP/0083/W11/2021
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentNew
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillageTilaiya
Taluka25
Architect Details
Architect NameKIRAN KUMARI
License No.JNP/ENG/0001/2019
Architect AddressIDEAL CONSTRUCTION, JHUMRI TELAIYA, KODERMA
Architect EmailIDIDEALCONSTRUCTION78@GMAIL.COM
Architect Mobile No7717750796
Plot Details
Plot Use Residential
Plot SubUse Bungalow/ Dwelling / Non Apartment
PlotNearbyReligiousStructure NA
Plot/SubPlot No7404
NorthPlot No. - TODAY SOLD TO PRADEEP KUMAR HISARIYA
SouthPlot No. - LAND OF RAMCHANDRA PRASAD AND OTHERS
EastPlot No. - LAND OF YASODA DEVI
WestRoad Width - 9.1
Owner's Details
Name(1) SMT SHUBHA KAPSIME (2) SMT SUNITA SETH
AddressAT - BHADANI ROAD JHUMRI TELAIYA DIST - KODERMA JHARKHAND
Email IDIDEALCONSTRUCTION78@GMAIL.COM
Mobile No7070098753
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 215.71
2 Plot area as per Document by Applicant 215.71
3 Area as per Site Visit (Site Visit Report) 215.71
4Area as per Drawing 215.71

Area of Plot Considered : 215.71

[-] Table 2b
Proposal Detail :
UnitMeters
Development Detail :
PlotPLOT
Plot OccupancyResidential
Plot SubUse Bungalow/ Dwelling / Non Apartment
Building StructureNon-Highrise
Building TypeSingle Detached House
Gross Plot Area 215.71
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 215.71
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 200.58
Deductions for Balance Plot Area (from Gross Plot Area)
- Common Plot 15.13
15.13
Balance Plot Area 200.58

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 60.00 % ) 129.43
Proposed Coverage Area ( 59.08 % ) 127.44
Total Prop. Coverage Area ( 59.08 % ) 127.44
Balance coverage area ( 0.92 % ) 1.99
FAR CHECK
Perm. FAR Area ( 2.00 ) 431.42
Total Perm. FAR area 431.42
Residential FAR 509.98
Proposed FAR Area 522.48
Total Proposed FAR Area 522.48
Consumed FAR (Factor) 2.42
Balance FAR Area 0.00
Total Paid Proposed FAR Area 91.06
BUA CHECK
Total Proposed BuiltUp Area 659.01


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Up to 50 meter -
Existing Road Width 9.1 9.10
Proposed Road Width as per Master Plan 9.1 -
Road Widening Width 0.1 -
Plot size (as per measurement) 215.71 215.71
[-] Extra Land Area Checks
Name Area Status
Reqd Prop
Extra Land - 0.00 OK


[-] Plot Level Checking (Table 3)
   
[-] Common Plot Checks (Table 3b)
Name Total Area Status
Reqd Prop
Common Plot 10.79 15.13 OK


[-] Common Plot Checks (Table 3b)
Name Minimum Area Coverage Area Width Angle Access Status
Reqd Prop Perm Prop Reqd Prop Reqd Prop
Tree Cover (Plantation) - 15.13 0.00 0.00 - 0.94 - 90.00 No Access Provided OK


   
   
[-] Tree Details (Table 3g)
Name Nos Of Trees Status
Reqd Prop
Tree 2 4 OK
   
    [-] Plot Miscellanies Checks

No Rule Status
1 No construction shall be permitted for Building Height above 10.0 mt. or above G+2 in Plot having width less than 10.0 mt. {As per Rule No. 36} Failed
   
   
   


[-] Building Details (Table 4)
   
[-] Building USE/SUBUSE Details Building USE/SUBUSE Details
Building Name Building Use Building SubUse Building Structure
A (RESIDENTIAL) Residential Bungalow/ Dwelling / Non Apartment Non-Highrise
   
   
   
[-] Height Details (4a)



[-] Total Height (Table 4a-1)
Building Height Height (From GL) Height (From Street LVL) Status
Perm Prop
A (RESIDENTIAL) 17.61 11.58 11.58 11.58 OK


   
   
[-] Floor Height Check (Table 4a-2)
Building Name Floor Name Height Clear Height Beam Clear Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
A (RESIDENTIAL) Third Floor 2.75 - 2.90 2.75 - 2.80 2.40 - 2.64 OK
Second Floor 2.75 - 2.90 2.75 - 2.80 2.40 - 2.64 OK
First Floor 2.75 - 2.90 2.75 - 2.80 2.40 - 2.64 OK
Ground Floor 2.75 - 2.90 2.75 - 2.80 2.40 - 2.64 OK
Basement Floor 2.40 - 2.74 2.40 - 2.64 2.10 - 2.49 OK


[-] Parapet Height Check (Table 4a-2.1)
Building Name Floor Name Height Status
Reqd Perm Prop
A (RESIDENTIAL) Terrace Floor - - 1.07 OK
   
   
[-] Basement Floor Check (Table 4a-3)
Building Name Floor Name Height Below GL Area Ventilation Area (Sq.mt.) Status
Perm Prop Perm Prop Reqd Prop
A (RESIDENTIAL) Basement Floor - 1.67 - 127.44 - 0.00 OK


[-] Basement Floor Area Check
Building Name Area Status
Perm Prop
A (RESIDENTIAL) - 127.44
Total - 127.44 OK

1 [-] Basement Margin Check
Building / Wing Road Name Front Side Rear Side Side1 Side2 Status
Reqd. Prop. Reqd. Prop. Reqd. Prop. Reqd. Prop.
  A-1 (RESIDENTIAL)   9.1 METER WIDE ROAD 3.00 3.96 2.25 1.83 0.90 0.97 0.90 0.97 Failed

    >
    [-] Permissible Use In Basement
Basement Area Status
Permissible Proposed
10.61 3.95 OK
   
[-] Floor Number Check (Table 4a-4)
Building Name No. of Floors No. of Tenements Status
Perm Prop Perm Prop
A (RESIDENTIAL) G + 6 4 - 1 OK


[-] Basement Floor Number Check
Building Name No. of Basement Floor Status
Perm Prop
A (RESIDENTIAL) 1 1 OK
 
   
    [-] Coverage Check (Table 4b)
Permissible Proposed Status
129.43 127.44 OK
60% 59.08%

[-] Individual Coverage Check
Coverage Area Perm. Prop.
  A-1 (RESIDENTIAL) - 127.44
  Total Prop. Coverage Area - 127.44
  Total Coverage Area 129.43 127.44

[-] FAR & Tenement Details (Table 4c-1)
Building No. of Same Bldg Total Built Up Area (Sq.mt.) Deductions (Area in Sq.mt.) Proposed FAR Area (Sq.mt.) Add Area In FAR (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
Lift Balcony Accessory Use Parking Resi. Stair
A (RESIDENTIAL) 1 659.01 19.68 6.84 3.95 106.07 509.97 12.50 522.47 522.47 01
Grand Total : 1 659.01 19.68 6.84 3.95 106.07 509.97 12.50 522.47 522.47 01


[-] Buildingwise Floor FAR Details
Floor Name Building Name Total
A (RESIDENTIAL)
Proposed Built Up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Total Proposed Built Up Area (Sq.mt.) Total FAR Area (Sq.mt.)
Basement Floor 127.44 12.50 127.44 12.50
Ground Floor 127.44 127.44 127.44 127.44
First Floor 134.71 127.51 134.71 127.51
Second Floor 134.71 127.51 134.71 127.51
Third Floor 134.71 127.51 134.71 127.51
Terrace Floor 0.00 0.00 0.00 0.00
Total : 659.01 522.47 659.01 522.47


[-] UnitBUA Table for Building :A (RESIDENTIAL)
UnitBUA CALCULATION
FLOOR Name UnitBUA Type UnitBUA Area Carpet Area No. of Rooms No. of Tenement
GROUND FLOOR PLAN SPLIT A FLAT 404.23 384.75 3 1
TYPICAL - 1- 3 FLOOR PLAN SPLIT A FLAT 0.00 0.00 3 0
Total: - - 404.23 384.75 12 1


[-] Building :A (RESIDENTIAL)
Floor Name Total Built Up Area (Sq.mt.) Deductions (Area in Sq.mt.) Proposed FAR Area (Sq.mt.) Add Area In FAR (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
Lift Balcony Accessory Use Parking Resi. Stair
Basement Floor 127.44 4.92 0.00 3.95 106.07 0.00 12.50 12.50 12.50 00
Ground Floor 127.44 0.00 0.00 0.00 0.00 127.44 0.00 127.44 127.44 01
First Floor 134.71 4.92 2.28 0.00 0.00 127.51 0.00 127.51 127.51 00
Second Floor 134.71 4.92 2.28 0.00 0.00 127.51 0.00 127.51 127.51 00
Third Floor 134.71 4.92 2.28 0.00 0.00 127.51 0.00 127.51 127.51 00
Terrace Floor 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 00
Total : 659.01 19.68 6.84 3.95 106.07 509.97 12.50 522.47 522.47 01
Total Number of Same Buildings : 1
Total : 659.01 19.68 6.84 3.95 106.07 509.97 12.50 522.47 522.47 01
[-] Table 4c-2

  FAR Area
Building FAR Area:522.48
Existing FAR Area :0.00
Perm.
431.42
Prop.
522.48
Status
Failed




[-] Margin Checks (Table 5)
   
[-] Plot Margin (Table 5a)
Building / Wing Road Name Front Side Rear Side Side1 Side2 Status
Reqd. Prop. Reqd. Prop. Reqd. Prop. Reqd. Prop.
A-1 (RESIDENTIAL) 9.1 METER WIDE ROAD 3.00 3.96 2.25 1.83 0.90 0.97 0.90 0.97 Failed






[-] Inner Building Details (Table 6)
   
   
[-] Balcony Details (Table 6c)

[-] For Building:A (RESIDENTIAL)
Floor Name Balcony Name Width Status
Perm Prop
TYPICAL - 1- 3 FLOOR PLAN BALCONY 1.20 0.92 OK



For PWork At Layout : 

No Balcony Found.

   
   
   
[-] Lift Details (Table 6d)
Building Name Height Number Of Lift(s) Number Of Strature Lift(s) Capacity Of Lift(s) Passanger Status
Prop Reqd Prop Reqd Prop Reqd Prop
A (RESIDENTIAL) 11.58 - 1 - 0 - 13 OK

[-] Lift Check Table

[-] For Building :A (RESIDENTIAL)
Floor Name Lift Name Width Depth Status
Reqd Prop Reqd Prop
BASEMENT FLOOR PLAN PASSENGER LIFT for 13 Persons 1.90 1.90 2.50 2.59 OK
GROUND FLOOR PLAN PASSENGER LIFT for 13 Persons 1.90 1.90 2.50 2.59 OK
TYPICAL - 1- 3 FLOOR PLAN PASSENGER LIFT for 13 Persons 1.90 1.90 2.50 2.59 OK
TERRACE FLOOR PLAN Lift Machine Room 1.70 1.90 1.90 2.59 OK

   


[-] Parking Details (Table 7)
   

NO PARKING CHECK REQUIRED FOR SINGLE DWELLING UNIT. Bungalow/ Dwelling / Non Apartment, In Building: A (RESIDENTIAL)
   


[-] Exemption Details (Table 8)
   


Not Required to Check StairCase Number Rule.


[-] Staircase Checks (Table 8a-1)


[-] For Building :A (RESIDENTIAL)
Floor Name StairCase Name Flight Width Tread Width Riser Height Riser No. On Flight Cabin Ht. Status
Reqd Prop Reqd Prop Perm Prop Perm Prop Reqd Perm Prop
BASEMENT FLOOR PLAN STAIRCASE 0.900 1.219 0.250 0.254 0.200 0.000 - 0 - - 0.000 OK
GROUND FLOOR PLAN STAIRCASE 0.900 1.219 0.250 0.254 0.200 0.132 - 11 - - 0.000 OK
TYPICAL - 1- 3 FLOOR PLAN STAIRCASE 0.900 1.219 0.250 0.254 0.200 0.132 - 11 - - 0.000 OK
TERRACE FLOOR PLAN STAIRCASE - 1.219 - 0.254 - 0.000 - 0 - - 2.438 OK

   
   
   

[-] Ramp Checks (Table 8b-a)
Ramp Name Width Depth Slope Status
Reqd Prop Reqd Prop Reqd Perm Prop
11.76 mt. long 1.68 mt. High 3.05 mt. Wide Natural Slope - 3.05 - 1.68 - - - OK


[-] Ramp Checks (Table 8b)
Building Name Floor Name No. Status
Reqd Prop
A (RESIDENTIAL) BASEMENT FLOOR PLAN 1 1 OK

   
   
   
[-] Accessory Use Check (Table 8d)
Accessory Use Name Area Width Depth Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
Toilet - 5.00 3.95 - - 1.52 - - 2.59 - - 0.00 OK
RWH - - 0.23 - - 0.55 - - 0.55 - - 0.00 OK
ENT.GATE - - 0.32 - - 0.11 - - 2.95 - - 0.00 OK
SOLAR HEATING SYSTEM - - 0.22 - - 0.53 - - 0.53 - - 0.00 OK





[-] Accessory Use No. Checks
Building Name Accessory Use Name No Status
Reqd Perm Prop
A (RESIDENTIAL) Rain Water Harvesting 1 - 1 OK
Entrance Gate 1 - 1 OK
   
   


[-] Floor Details (Table 9)
   

[-] Building:A (RESIDENTIAL)


[-] Floor:BASEMENT FLOOR PLAN



No Room Found.


[-] Floor:GROUND FLOOR PLAN



All Dimensions and Area of all the Rooms on this Floor are as per the Rules.

[-] Floor:TYPICAL - 1- 3 FLOOR PLAN



All Dimensions and Area of all the Rooms on this Floor are as per the Rules.


   


[-] Summary (Table 10)
   
Name Perm./Reqd. Proposed Status
  Plot Area - 215.71 OK
  Plot Width - 9.88 OK
  Plot Depth - 21.83 OK
  Access Width - 9.10 OK
  Plot Frontage - 9.88 OK
  Coverage Area 129.43 127.44 OK
  FAR Area
Bldg. FAR Area : 522.48
Sanctioned FAR Area :0.00
431.42 522.48 Failed





[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Width No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Depth No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Access Width The minimum width of abutting road for any Building shall be with respect to Length of Road {As per Rule No. 34 Table No.6}
Plot Frontage No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
FAR Area (1) In Old Area, for Residential Building on abutting roadwidth 9.10 (30 ft.) to 12.20 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15}
(2) For Jhumritilaiya Nagar Parishad, Max. 2.0 permissible FAR may be permitted for Residential Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Residential Building on abutting roadwidth 9.10 (30 ft.) to 12.20 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15}
(2) For Jhumritilaiya Nagar Parishad, Max. 2.0 permissible FAR may be permitted for Residential Use {As per Annexure III}
Common Plot Area In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
Common Plot (1) In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
(2) ;
Tree Number 2-4 Trees shall be required for the Plot area upto 250.0 sq.mt. (As per Rule No. 20.1.6)
Margin Rule For Non-highrise Residential Building 10-13.3 mt. Ht. having Plot Depth 21-27 mt. and Plot width upto 10 mt., Margin required in Front shall be 3.0 mt., Rear 2.25 mt. and 0.9 mt. shall be provided on both side. {As per Rule No. 36 (Table 8 & 9 and updated as per 4th Amendment dated 2nd Jan, 2019}
Basement Margin Rule Basements/cellars may be permitted to be constructed leaving the prescribed set back/open space applicable to the building {As per Rule No. 48}
Building Level
Building Height For old area, on Road width 9.10-12.20 mt., Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 23.10 mt. {As per Rule No. 39.1 Table 15}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(3) o Every basement shall be in every part at least 2.4 m. in height from the floor to the soffit of the roof slab or ceiling and mini. Of 2.1 mr. below the soffit of beams {As per Rule No. 48}
Parapet Height Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
Below GL Floor Height ,
Basement Floor No. Individual residential and small commercial buildings, plot size upto minimum 750 Sq. Meter may have one basement {As per Rule No. 48}
Floor Number For old area location,on Road width 9.1-12.20 mt. only G+6 floors shall be allowed {As per Rule No. 39.1 Table 15}
Balcony Projected balcony may be allowed with a widt of 1.2 mt. where the setback is more than 2.5 mt. {As per Rule No. 46.4 and modified as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
Lift Count (1) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(2) For Residential Building height upto 15.0 mt or upto G+4 floors, No Lift is reqd. {As per Amended 06-06-2019 Rule No. 49.1.1}
Lift (1) The area of lift well shall not be counted for F.A.R calculation)
(2) The lift shall have a minimum width 1.9 mt. and minimum depth 2.5 mt.{As per clause no 4 and page no. 14 NBC }
(3) The area of lift well at one floor only (not the sum of total area of lift well at every floor) shall be counted for F.A.R calculation)
(4) The lift shall have a minimum width 1.9 mt. and minimum depth 2.5 mt.{As per clause no 4 and page no. 14 NBC }
(5) -
StairCase (1) Width of Winding staircase shall be mini. 0.90 mt.,Maximum rise 0.20 mt. & Minimum tread 0.25 mt. & Cabin Height 2.1 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) No Rule Defined
(4) ; No Rule Defined
Ramp No Need to Check Natural Slope width, Depth or height. ;
Ramp No. For parking spaces in basements and upper storey of parking floors, if car parking is less then 40 one ramp of minimum of 3.30m width if it is straight and 4.50m width if it is curved shall be provided
Plot / Building Level
Accessory Use (1) Common toilet of maximum size of 5 sq.mt shall be taken Free from FAR
(2) No need to check distance from Building Toilet
(3) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(4) No need to check distance from Building RWH
(5) No need to check distance from Building ENT.GATE
(6) -
(7) No need to check distance from Building SOLAR HEATING SYSTEM
Accessory Use Number (1) Provision of Rain Water Harvesting shall be mandatory for any use {Updated as per JBBL, Amendment VIII dated 16/03/2021} Rain Water Harvesting
(2) In case of buildings with a height of 15.0 meters and above or ground coverage more than 500 sqm., the main entrance to the premise shall not be less than 5 (five) meters i n width in order to allow easy access to fire engine Entrance Gate
Building Level (Rooms)