RegionJHARKHAND URBAN LOCAL BODIES
DistrictKODERMA
AuthorityJHUMRITILAIYA NAGAR PARISHAD
Inward_NoJNP/BP/0089/W10/2021
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentNew
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillageTilaiya
Taluka25
Architect Details
Architect NameKIRAN KUMARI
License No.JNP/ENG/0001/2019
Architect AddressIDEAL CONSTRUCTION, JHUMRI TELAIYA, KODERMA
Architect EmailIDIDEALCONSTRUCTION78@GMAIL.COM
Architect Mobile No7717750796
Plot Details
Plot Use Mixed
Plot SubUse Resi+Comm
PlotNearbyReligiousStructure NA
Plot/SubPlot No7458. 7459
NorthPlot No. - HOUSE OF CHANDRIKA SINGH
SouthPlot No. - LAND OF LADDU GOPAL RAJGARIYA ALIAS
EastPlot No. - HOUSE OF RAVINDRA NATH SINGH
WestPlot No. - 4.5
Owner's Details
Name(1) SMT SHUBHA KAPSIME (2) SMT SUNITA SETH
Address(1) AT - JHUMRI TELAIYA, BHADANI ROAD DIST - KODERMA JHARKHAND, (2) AT- JHUMRI TELAIYA PATNA TRANSPORT GALI, DIST - KODERMA JHARKHAND.
Email IDIDEALCONSTRUCTION78@GMAIL.COM
Mobile No7070098753
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 415.77
2 Plot area as per Document by Applicant 415.77
3 Area as per Site Visit (Site Visit Report) 415.77
4Area as per Drawing 415.77

Area of Plot Considered : 415.77

[-] Table 2b
Proposal Detail :
UnitMeters
Development Detail :
PlotPLOT
Plot OccupancyMixed
Plot SubUse -
Higher Plot Use
Higher Plot Sub UseResi+Comm
Lower Plot Use
Lower Plot Sub Use
Building StructureNon-Highrise
Building TypeSingle Detached House
Gross Plot Area 415.77
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 415.77
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 373.61
Deductions for Balance Plot Area (from Gross Plot Area)
- Common Plot 42.16
42.16
Balance Plot Area 373.61

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 60.00 % ) 249.46
Proposed Coverage Area ( 58.34 % ) 242.56
Total Prop. Coverage Area ( 58.34 % ) 242.56
Balance coverage area ( 1.66 % ) 6.90
FAR CHECK
Perm. FAR Area ( 2.00 ) 831.54
Total Perm. FAR area 831.54
Residential FAR 140.87
Commercial FAR 505.68
Proposed FAR Area 656.03
Total Proposed FAR Area 656.03
Consumed FAR (Factor) 1.58
Balance FAR Area 175.51
BUA CHECK
Total Proposed BuiltUp Area 970.23


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Up to 50 meter -
Existing Road Width 4.5 4.50
Proposed Road Width as per Master Plan 4.5 -
Road Widening Width 0.1 -
Plot size (as per measurement) 415.77 415.77
[-] Extra Land Area Checks
Name Area Status
Reqd Prop
Extra Land - 0.00 OK

     Extra Land Area Details
Name Description Unit Reqd Perm Proposed Status
Extra Land Area Details Extra Land Area - - 0.00 OK

     Plot Related Details
Name Description Unit Reqd Perm Proposed Status
PLOT Plot Area Sq.Mt. - - 415.77 OK
Plot Width Mt. - - 9.83 OK
Plot Depth Mt. - - 42.29 OK
Access Width Mt. - - 4.50 OK
Plot Frontage Mt. - - 9.14 OK
Coverage Area Sq.Mt. - 249.46 242.56 OK
FAR Area Sq.Mt. - 831.54 656.03 OK
Consumed FAR Sq.Mt. - 2.00 1.58 OK
Common Plot Checks Common Plot - Total Area Sq.Mt. 41.58 42.16 OK
Common Plot Tree Cover (Plantation) - Minimum Area Sq.Mt. - 42.16 OK
Tree Cover (Plantation) - Coverage Area Sq.Mt. - - OK
Tree Cover (Plantation) - Width Mt. - 1.48 OK
Tree Cover (Plantation) - Angle Degree - 88.78 OK
Tree Cover (Plantation) - Access Mt. - OK
Tree Tree - Nos Of Trees No. 4 8 OK
Car In Area Sq.Mt. - - 37.50 OK
Four Stack.Car In Area Sq.Mt. - - 112.50 OK
Total Car In Area Sq.Mt. 62.50 - 150.00 OK
TwoWheeler In Area Sq.Mt. - - 62.00 OK
Total TwoWheeler In Area Sq.Mt. 32.00 - 62.00 OK
Other Parking In Area Sq.Mt. - - 167.10 OK
DriveWay PLOT - - - DRIVEWAY - Width No. 3.60 - 3.93 OK
A (SHOP) - BASEMENT FLOOR PLAN - DRIVEWAY TW1 - Width No. 3.00 - 3.00 OK
A-1 (SHOP) Front Margin... 4.5 METER WIDE ROAD Mt. 4.00 - 8.38 OK
Rear Margin Mt. 4.00 - 4.53 OK
Side1 Margin Mt. - - 0.00 OK
Side2 Margin Mt. 0.90 - 1.50 OK
A-1 (SHOP) Basement Front Margin... 4.5 METER WIDE ROAD Mt. 2.00 - 8.38 OK
Basement Rear Margin Mt. 2.00 - 4.53 OK
Basement Side1 Margin Mt. - - 0.00 OK
Basement Side2 Margin Mt. 0.90 - 1.42 OK

     Building Related Details
Name Description Unit Reqd Perm Proposed Status
A (SHOP) Height Mt. 10.00 8.69 OK
A (SHOP) Second Floor - Height Mt. 2.75 - 2.90 OK
Second Floor - Clear Height Mt. 2.75 - 2.77 OK
Second Floor - Beam Clear Height Mt. 2.40 - 2.51 OK
First Floor - Height Mt. 2.75 - 2.90 OK
First Floor - Clear Height Mt. 2.75 - 2.77 OK
First Floor - Beam Clear Height Mt. 2.40 - 2.51 OK
Ground Floor - Height Mt. 2.75 - 2.90 OK
Ground Floor - Clear Height Mt. 2.75 - 2.77 OK
Ground Floor - Beam Clear Height Mt. 2.40 - 2.51 OK
Basement Floor - Height Mt. 2.40 - 2.74 OK
Basement Floor - Clear Height Mt. 2.40 - 2.62 OK
Basement Floor - Beam Clear Height Mt. 2.10 - 2.36 OK
A (SHOP) Terrace Floor - Height Mt. - - 1.07 OK
A (SHOP) Basement Floor - Height Below GL Mt. - 1.67 OK
Basement Floor - Area Sq.Mt. - 242.56 OK
Basement Floor - Ventilation Area (Sq.mt.) Sq.Mt. - - OK
A (SHOP) Area Sq.Mt. - 242.56 OK
Status - OK
Total Area Sq.Mt. - 242.56 OK
A (SHOP) No. of Basement Floor No. 1 1 OK
A (SHOP) No. of Floors No. G + 2 3 OK
No. of Tenements No. - 7 OK
A (SHOP) GROUND FLOOR PLAN - Passage Name - OK
GROUND FLOOR PLAN - Width Mt. 1.00 1.83 OK
GROUND FLOOR PLAN - Length Mt. - 3.05 OK
GROUND FLOOR PLAN - Passage Name - OK
GROUND FLOOR PLAN - Width Mt. 1.00 2.68 OK
GROUND FLOOR PLAN - Length Mt. - 6.03 OK
GROUND FLOOR PLAN - Passage Name - OK
GROUND FLOOR PLAN - Width Mt. 1.00 1.83 OK
GROUND FLOOR PLAN - Length Mt. - 14.18 OK
TYPICAL - 1& 2 FLOOR PLAN - Passage Name - OK
TYPICAL - 1& 2 FLOOR PLAN - Width Mt. 1.00 1.83 OK
TYPICAL - 1& 2 FLOOR PLAN - Length Mt. - 14.18 OK
A (SHOP) Number Of Lift(s) No. - 1 OK
Number Of Strature Lift(s) No. - - OK
Capacity Of Lift(s) Passanger No. - 10 OK
A (SHOP) BASEMENT FLOOR PLAN - PASSENGER LIFT for 10 Persons - Width Mt. 1.90 1.90 OK
BASEMENT FLOOR PLAN - PASSENGER LIFT for 10 Persons - Depth Mt. 2.10 2.10 OK
GROUND FLOOR PLAN - PASSENGER LIFT for 10 Persons - Width Mt. 1.90 1.90 OK
GROUND FLOOR PLAN - PASSENGER LIFT for 10 Persons - Depth Mt. 2.10 2.10 OK
TYPICAL - 1& 2 FLOOR PLAN - PASSENGER LIFT for 10 Persons - Width Mt. 1.90 1.90 OK
TYPICAL - 1& 2 FLOOR PLAN - PASSENGER LIFT for 10 Persons - Depth Mt. 2.10 2.10 OK
TERRACE FLOOR PLAN - Lift Machine Room - Width Mt. 1.70 1.90 OK
TERRACE FLOOR PLAN - Lift Machine Room - Depth Mt. 1.90 2.10 OK
BASEMENT FLOOR PLAN STAIRCASE - Flight Width Mt. 0.900 1.219 OK
STAIRCASE - Tread Width Mt. 0.250 0.254 OK
STAIRCASE - Riser Height Mt. 0.200 - OK
STAIRCASE - Riser No. On Flight No. - - OK
STAIRCASE - Cabin Ht. Mt. - - - OK
GROUND FLOOR PLAN STAIRCASE - Flight Width Mt. 0.900 1.219 OK
STAIRCASE - Tread Width Mt. 0.250 0.254 OK
STAIRCASE - Riser Height Mt. 0.200 0.161 OK
STAIRCASE - Riser No. On Flight No. - 9 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
TYPICAL - 1& 2 FLOOR PLAN STAIRCASE - Flight Width Mt. 0.900 1.219 OK
STAIRCASE - Tread Width Mt. 0.250 0.254 OK
STAIRCASE - Riser Height Mt. 0.200 0.161 OK
STAIRCASE - Riser No. On Flight No. - 9 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
TERRACE FLOOR PLAN STAIRCASE - Flight Width Mt. - 1.219 OK
STAIRCASE - Tread Width Mt. - 0.254 OK
STAIRCASE - Riser Height Mt. - - OK
STAIRCASE - Riser No. On Flight No. - - OK
STAIRCASE - Cabin Ht. Mt. - - 2.438 OK
Toilet Area Sq.Mt. - 5.00 4.76 OK
Width Mt. - - 1.45 OK
Depth Mt. - - 3.28 OK
Height Mt. - - - OK
Area Sq.Mt. - 5.00 4.84 OK
Width Mt. - - 1.48 OK
Depth Mt. - - 3.28 OK
Height Mt. - - - OK
Area Sq.Mt. - 5.00 4.76 OK
Width Mt. - - 1.45 OK
Depth Mt. - - 3.28 OK
Height Mt. - - - OK
Area Sq.Mt. - 5.00 4.84 OK
Width Mt. - - 1.48 OK
Depth Mt. - - 3.28 OK
Height Mt. - - - OK
RW Area Sq.Mt. - - 0.07 OK
Width Mt. - - 0.30 OK
Depth Mt. - - 0.30 OK
Height Mt. - - - OK
ENT.GATE Area Sq.Mt. - - 0.20 OK
Width Mt. - - 0.09 OK
Depth Mt. - - 2.23 OK
Height Mt. - - - OK
Entrance Lobby Area Sq.Mt. - 12.00 11.99 OK
Width Mt. - - 3.15 OK
Depth Mt. - - 5.06 OK
Height Mt. - - - OK
Area Sq.Mt. - 12.00 11.99 OK
Width Mt. - - 3.15 OK
Depth Mt. - - 5.06 OK
Height Mt. - - - OK
SHS Area Sq.Mt. - - 0.05 OK
Width Mt. - - 0.25 OK
Depth Mt. - - 0.25 OK
Height Mt. - - - OK
A (SHOP) Rain Water Harvesting - No No. 1 - 1 OK
Entrance Gate - No No. 1 - 1 OK
PLOT 7.30 mt. long 1.00 mt. High 3.00 mt. Wide Natural Slope - Width Mt. - 3.00 OK
7.30 mt. long 1.00 mt. High 3.00 mt. Wide Natural Slope - Depth Mt. - 1.00 OK
7.30 mt. long 1.00 mt. High 3.00 mt. Wide Natural Slope - Slope Ratio - - - OK
Ramp No. A (SHOP) - BASEMENT FLOOR PLAN - No. No. 1 1 OK
   
    All Rooms are as per Rule in Room Checking




[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Width No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Depth No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Access Width The minimum width of abutting road for any Building shall be with respect to Length of Road {As per Rule No. 34 Table No.6}
Plot Frontage No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
FAR Area (1) In Old Area, for Non-Residential Building on abutting roadwidth 3.60 (12 ft.) to 4.80 mt., the Floor Area Ratio-FAR shall be Nil {As per Rule No.39, Table 15}
(2) For Jhumritilaiya Nagar Parishad, Max. 2.0 permissible FAR may be permitted for Commercial or Mercantile type Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Non-Residential Building on abutting roadwidth 3.60 (12 ft.) to 4.80 mt., the Floor Area Ratio-FAR shall be Nil {As per Rule No.39, Table 15}
(2) For Jhumritilaiya Nagar Parishad, Max. 2.0 permissible FAR may be permitted for Commercial or Mercantile type Use {As per Annexure III}
Common Plot Area In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
Common Plot (1) In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
(2) ;
Tree Number 4-8 Trees shall be required for the Plot area above 250.0 and upto 1000.0 sq.mt. (As per Rule No. 20.1.6)
DriveWay Rule (1) For Plor area upto 2000 sq.mt., the minimum width or driveways should not be less than 3.60 mt. {As per Rule No. 41.2 and modified as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
(2) The minimum width of the drive way meant exclusively for 2 wheelers should be 3.0 mt {As per Rule No. 41.2}
Margin Rule For Non-highrise Residential Building upto 10.0 mt. Ht. having Plot Depth 39-45 mt. and Plot width upto 10 mt., Margin required in Front shall be 4.0 mt., Rear 4.0 mt. and Atleast 0.9 mt. shall be provided at one side. {As per Rule No. 36 (Table 8 & 9)}
Basement Margin Rule In case of apartment/ group housing/commercial building and basements may be allowed to be constructed under the entire plot area leaving mini. 2 mt. space from the boundary of the premises {As per Rule No. 48}
Building Level
Building Height For old area, on Road width 3.6-4.8 mt., Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 10.0 mt. {As per Rule No. 39.1 Table 15}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(3) o Every basement shall be in every part at least 2.4 m. in height from the floor to the soffit of the roof slab or ceiling and mini. Of 2.1 mr. below the soffit of beams {As per Rule No. 48}
Parapet Height Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
Below GL Floor Height ,
Basement Floor No. Individual residential and small commercial buildings, plot size upto minimum 750 Sq. Meter may have one basement {As per Rule No. 48}
Floor Number For old area location,on Road width 3.6-4.8 mt. only G+2 floors shall be allowed {As per Rule No. 39.1 Table 15}
Passage No exit doorway shall be less than 1.00 m. in width. {As per Rule No.43.4.2} ;
Lift Count (1) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(2) For Residential Building height upto 15.0 mt or upto G+4 floors, No Lift is reqd. {As per Amended 06-06-2019 Rule No. 49.1.1}
Lift (1) The area of lift well shall not be counted for F.A.R calculation)
(2) The lift shall have a minimum width 1.9 mt. and minimum depth 2.1 mt.{As per clause no 4 and page no. 14 NBC }
(3) The area of lift well at one floor only (not the sum of total area of lift well at every floor) shall be counted for F.A.R calculation)
(4) The lift shall have a minimum width 1.9 mt. and minimum depth 2.1 mt.{As per clause no 4 and page no. 14 NBC }
(5) -
StairCase (1) Width of Winding staircase shall be mini. 0.90 mt.,Maximum rise 0.20 mt. & Minimum tread 0.25 mt. & Cabin Height 2.1 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) No Rule Defined
(4) ; No Rule Defined
Ramp No Need to Check Natural Slope width, Depth or height. ;
Ramp No. For parking spaces in basements and upper storey of parking floors, if car parking is less then 40 one ramp of minimum of 3.30m width if it is straight and 4.50m width if it is curved shall be provided
Plot / Building Level
Accessory Use (1) Common toilet of maximum size of 5 sq.mt shall be taken Free from FAR
(2) No need to check distance from Building Toilet
(3) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(4) No need to check distance from Building RW
(5) No need to check distance from Building ENT.GATE
(6) Entrance Lobby of maximum size of 12 sq.m. shall be taken Free from FAR
(7) No need to check distance from Building Entrance Lobby
(8) -
(9) No need to check distance from Building SHS
Accessory Use Number (1) Provision of Rain Water Harvesting shall be mandatory for any use {Updated as per JBBL, Amendment VIII dated 16/03/2021} Rain Water Harvesting
(2) In case of buildings with a height of 15.0 meters and above or ground coverage more than 500 sqm., the main entrance to the premise shall not be less than 5 (five) meters i n width in order to allow easy access to fire engine Entrance Gate
Building Level (Rooms)