RegionJHARKHAND URBAN LOCAL BODIES
DistrictKODERMA
AuthorityJHUMRITILAIYA NAGAR PARISHAD
Inward_NoJNP/BP/0062/W27/2024
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentNew
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillageBelatar
Taluka25
Architect Details
Architect NameKIRAN KUMARI
License No.JNP/ENG/0001/2019
Architect AddressIDEAL CONSTRUCTION, JHUMRI TELAIYA, KODERMA
Architect EmailIDIDEALCONSTRUCTION78@GMAIL.COM
Architect Mobile No7717750796
Plot Details
Plot Use Residential
Plot SubUse Bungalow/ Dwelling / Non Apartment
PlotNearbyReligiousStructure NA
Plot/SubPlot No25
NorthPlot No. - PLOT NO - 15
SouthRoad Width - 7.62
EastPlot No. - LAND WITH HOUSE OF SURENDRA PRASAD PARHPURIA
WestPlot No. - LAND WITH HOUSE OF RAMESHWAR MODI
Owner's Details
NameSRI RISHABH RAJ
AddressAT - WARD NO - 27 JHANJHARI GALI JHUMRI TELAIYA DIST KODERMA JHARKHAND
Email IDrishabhkapsime@gmail.com
Mobile No8961334417
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 242.87
2 Plot area as per Document by Applicant 242.87
3 Physical area measured at site 242.87
4 Area as per Site Visit (Site Visit Report) 242.87
5Area as per Drawing 242.87

Area of Plot Considered : 242.87

Plot area provided in drawing shall not be more than Plot area as per Document.
[-] Table 2b
Proposal Detail :
Unit
Development Detail :
PlotPLOT
Plot OccupancyResidential
Plot SubUse Bungalow/ Dwelling / Non Apartment
Building StructureNon-Highrise
Building TypeSingle Detached House
Gross Plot Area 242.87
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 242.87
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 215.98
Deductions for Balance Plot Area (from Gross Plot Area)
- Common Plot 26.89
26.89
Balance Plot Area 215.98

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 60.00 % ) 145.72
Proposed Coverage Area ( 59.99 % ) 145.69
Total Prop. Coverage Area ( 59.99 % ) 145.69
Balance coverage area ( 0.01 % ) 0.03
FAR CHECK
Perm. FAR Area ( 2.000 ) 485.74
Total Perm. FAR area 485.74
Residential FAR 395.76
Proposed FAR Area 395.76
Total Proposed FAR Area 395.76
Consumed FAR (Factor) 1.63
Balance FAR Area 89.98
BUA CHECK
Total Proposed BuiltUp Area 438.17


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Up to 50 meter -
Existing Road Width 7.62 7.62
Proposed Road Width as per Master Plan 7.62 -
Road Widening Width 7.62 -
Plot size (as per measurement) 242.87 242.87
[-] Extra Land Area Checks
Name Area Status
Reqd Prop
Extra Land - 0.00 OK

     Extra Land Area Details
Name Description Unit Reqd Perm Proposed Status
Extra Land Area Details Extra Land Area - - 0.00 OK

     Plot Related Details
Name Description Unit Reqd Perm Proposed Status
PLOT Plot Area Sq.Mt. - - 242.87 OK
Plot Width Mt. - - 7.99 OK
Plot Depth Mt. - - 30.38 OK
Access Width Mt. - - 7.62 OK
Plot Frontage Mt. - - 6.05 OK
Coverage Area Sq.Mt. - 145.72 145.69 OK
FAR Area Sq.Mt. - 485.74 395.76 OK
Consumed FAR Sq.Mt. - 2.00 1.63 OK
Common Plot Checks Common Plot - Total Area Sq.Mt. 12.14 26.89 OK
Common Plot Tree Cover (Plantation) - Minimum Area Sq.Mt. - 26.89 OK
Tree Cover (Plantation) - Coverage Area Sq.Mt. - - OK
Tree Cover (Plantation) - Width Mt. - 4.45 OK
Tree Cover (Plantation) - Angle Degree - 89.99 OK
Tree Cover (Plantation) - Access Mt. - OK
Tree Tree - Nos Of Trees No. 2 4 OK
A-1 (RESIDENTIAL) Front Margin... 7.62 METER WIDE ROAD Mt. 4.00 - 5.87 OK
Rear Margin Mt. 2.50 - 2.50 OK
Side1 Margin Mt. - - 0.00 OK
Side2 Margin Mt. 0.90 - 1.07 OK

     Building Related Details
Name Description Unit Reqd Perm Proposed Status
A (RESIDENTIAL) Height Mt. 17.30 9.16 OK
A (RESIDENTIAL) Second Floor - Height Mt. 2.75 - 3.05 OK
Second Floor - Clear Height Mt. 2.75 - 2.92 OK
Second Floor - Beam Clear Height Mt. 2.40 - 2.79 OK
First Floor - Height Mt. 2.75 - 3.05 OK
First Floor - Clear Height Mt. 2.75 - 2.92 OK
First Floor - Beam Clear Height Mt. 2.40 - 2.79 OK
Ground Floor - Height Mt. 2.75 - 3.05 OK
Ground Floor - Clear Height Mt. 2.75 - 2.92 OK
Ground Floor - Beam Clear Height Mt. 2.40 - 2.79 OK
Plinth - Height Mt. 0.45 - 0.91 OK
Plinth - Clear Height Mt. - - 0.91 OK
Plinth - Beam Clear Height Mt. - - 0.91 OK
A (RESIDENTIAL) Terrace Floor - Height Mt. - - 1.07 OK
Terrace Floor - Clear Height Mt. - - 1.07 OK
Terrace Floor - Beam Clear Height Mt. - - 1.07 OK
A (RESIDENTIAL) No. of Floors No. G + 5 3 OK
No. of Tenements No. - 1 OK
GROUND FLOOR PLAN Staircase -3FL - Flight Width Mt. 0.900 1.067 OK
Staircase -3FL - Tread Width Mt. 0.250 0.254 OK
Staircase -3FL - Riser Height Mt. 0.200 0.085 OK
Staircase -3FL - Riser No. On Flight No. - 10 OK
Staircase -3FL - Cabin Ht. Mt. - - - OK
Internal Staircase - Flight Width Mt. - 1.067 OK
Internal Staircase - Tread Width Mt. - 0.229 OK
Internal Staircase - Riser Height Mt. - 0.139 OK
Internal Staircase - Riser No. On Flight No. 14 12 OK
Internal Staircase - Cabin Ht. Mt. - - - OK
FIRST FLOOR PLAN Staircase -3FL - Flight Width Mt. 0.900 1.067 OK
Staircase -3FL - Tread Width Mt. 0.250 0.254 OK
Staircase -3FL - Riser Height Mt. 0.200 0.085 OK
Staircase -3FL - Riser No. On Flight No. - 10 OK
Staircase -3FL - Cabin Ht. Mt. - - - OK
SECOND FLOOR PLAN Staircase -3FL - Flight Width Mt. 0.900 1.067 OK
Staircase -3FL - Tread Width Mt. 0.250 0.254 OK
Staircase -3FL - Riser Height Mt. 0.200 0.085 OK
Staircase -3FL - Riser No. On Flight No. - 10 OK
Staircase -3FL - Cabin Ht. Mt. - - - OK
TERRACE FLOOR PLAN Staircase -3FL - Flight Width Mt. - 1.067 OK
Staircase -3FL - Tread Width Mt. - 0.254 OK
Staircase -3FL - Riser Height Mt. - - OK
Staircase -3FL - Riser No. On Flight No. - - OK
Staircase -3FL - Cabin Ht. Mt. - - 2.438 OK
RWH Area Sq.Mt. - - 0.22 OK
Width Mt. - - 0.53 OK
Depth Mt. - - 0.53 OK
Height Mt. - - - OK
SOLAR HEATING SYSTEM Area Sq.Mt. - - 0.22 OK
Width Mt. - - 0.53 OK
Depth Mt. - - 0.53 OK
Height Mt. - - - OK
A (RESIDENTIAL) Rain Water Harvesting - No No. 1 - 1 OK
   
    All Rooms are as per Rule in Room Checking




[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Width No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Depth No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Access Width The minimum width of abutting road for any Building shall be with respect to Length of Road {As per Rule No. 34 Table No.6}
Plot Frontage No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
FAR Area (1) In Old Area, for Residential Building on abutting roadwidth 7.5 (25 ft.) to 9.10 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15}
(2) For Jhumritilaiya Nagar Parishad, Max. 2.0 permissible FAR may be permitted for Residential Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Residential Building on abutting roadwidth 7.5 (25 ft.) to 9.10 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15}
(2) For Jhumritilaiya Nagar Parishad, Max. 2.0 permissible FAR may be permitted for Residential Use {As per Annexure III}
Common Plot Area In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
Common Plot (1) In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
(2) ;
Tree Number 2-4 Trees shall be required for the Plot area upto 250.0 sq.mt. (As per Rule No. 20.1.6)
Margin Rule For Non-highrise Residential Building upto 10.0 mt. Ht. having Plot Depth 27-33 mt. and Plot width upto 10 mt., Margin required in Front shall be 4.0 mt., Rear 2.5 mt. and Atleast 0.9 mt. shall be provided at one side. {As per Rule No. 36 (Table 8 & 9)}
Building Level
Building Height For old area, on Road width 7.50-9.10 mt., Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 19.25 mt. {As per Rule No. 39.1 Table 15}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(3) The plinth or any part of a building shall be so located with respect to the surrounding ground level that adequate drainage of the site is assured. The height of the plinth (except in case of stilted parking) shall be not less than 0.45 mt. from the surrounding ground level {As per Rule No. 42.10}
Parapet Height (1) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
(2) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
(3) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
Floor Number For old area location,on Road width 7.5-9.1 mt. only G+5 floors shall be allowed {As per Rule No. 39.1 Table 15}
StairCase (1) Width of Winding staircase shall be mini. 0.90 mt.,Maximum rise 0.20 mt. & Minimum tread 0.25 mt. & Cabin Height 2.1 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) No Rule Defined
(4) ; Number of riser shall not exceed 14 per flight of stairs. {As per Rule No. 43.5.2.6}
(5) No Rule Defined
(6) ; No Rule Defined
Plot / Building Level
Accessory Use (1) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(2) No need to check distance from Building RWH
(3) -
(4) No need to check distance from Building SOLAR HEATING SYSTEM
Accessory Use Number Provision of Rain Water Harvesting shall be mandatory for any use {Updated as per JBBL, Amendment VIII dated 16/03/2021} Rain Water Harvesting
Building Level (Rooms)
Bed Room2.67x3.89 The area of habitable room shall not be less than 9.5 m2, where there is only one room with a minimum width of 2.4 m. Where there are two rooms, one of these shall not be less than 9.5 m2 and the other not less than 7.5 m2, with a minimum width of 2.1 mt.
Dining2.87x3.81 No Rule Defined
Kitchen1.80x3.89 Area for Kitchen shall be Mini. 5.0 sq.mt. having side mini. 1.8 mt. {Rule No. 42.3.2}
Kitchen3.28x1.98 Area for Kitchen when store room is provided shall be Mini. 4.5 sq.mt. having side mini. 1.8 mt. {Rule No. 42.3.2}
Toilet1.47x2.77 Area for Toilet shall be Mini. 2.8 sq.mt. having side mini. 1.2 mt. {Rule No. 42.4.2}