No Image Found   

Failed List Report

Jhumritilaiya Nagar Parishad

Version Number: 1.0.70  
Version Date: 16/10/2020 
Report Generated On: 24-07-2024 
 

[-] Collapse All


General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictKODERMA
AuthorityJHUMRITILAIYA NAGAR PARISHAD
Inward_NoJNP/BP/0074/W15/2024
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentNew
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillageTilaiya
Taluka25
Architect Details
Architect NameDEEPAK KUMAR SAW
License No.JNP/ENG/0004/2023
Architect AddressRAM AND SAN S CONSTRUCTION PLANNER SMART BAZAR. UJJALA COMPLEX JHUMRI TELAIYA
Architect EmailIDerdeepakcivil9939@gmail.com
Architect Mobile No9939257831
Plot Details
Plot Use Residential
Plot SubUse Bungalow/ Dwelling / Non Apartment
PlotNearbyReligiousStructure NA
Plot/SubPlot No5542, 7516
NorthRoad Width - 7.61
SouthPlot No. - ROAD MUNICIPAL ROAD
EastRoad Width - 3.65
WestRoad Width - 3.65
Owner's Details
Name1. SMT ASHA DEVI KHETYAN 2. OM PRAKESH KHETYAN
AddressADDI BANGLOW ROAD JHUMRI TELAIYA KODERMA
Email IDAJAYKUMAR7033100@GMAIL.COM
Mobile No9934190109
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 339.16
2 Plot area as per Document by Applicant 317.56
3 Physical area measured at site 337.56
4 Area as per Site Visit (Site Visit Report) 337.56
5Area as per Drawing 317.56

Area of Plot Considered : 317.56

Plot area provided in drawing shall not be more than Plot area as per Document.
[-] Table 2b
Proposal Detail :
Unit
Development Detail :
PlotPLOT
Plot OccupancyResidential
Plot SubUse Bungalow/ Dwelling / Non Apartment
Building StructureNon-Highrise
Building TypeSingle Detached House
Gross Plot Area 317.56
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 317.56
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 283.47
Deductions for Balance Plot Area (from Gross Plot Area)
- Common Plot 34.09
34.09
Balance Plot Area 283.47

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 60.00 % ) 190.54
Proposed Coverage Area ( 38.81 % ) 123.23
Total Prop. Coverage Area ( 38.81 % ) 123.23
Balance coverage area ( 21.20 % ) 67.31
FAR CHECK
Perm. FAR Area ( 2.000 ) 635.12
Total Perm. FAR area 635.12
Residential FAR 492.93
Proposed FAR Area 492.93
Total Proposed FAR Area 492.93
Consumed FAR (Factor) 1.55
Balance FAR Area 142.19
BUA CHECK
Total Proposed BuiltUp Area 492.92


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Up to 50 meter -
Existing Road Width 7.61 7.61
Proposed Road Width as per Master Plan 7.55 -
Road Widening Width 0 -
Plot size (as per measurement) 337.56 317.56
[-] Extra Land Area Checks
Name Area Status
Reqd Prop
Extra Land - 0.00 OK
   



[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Width No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Depth No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Access Width The minimum width of abutting road for any Building shall be with respect to Length of Road {As per Rule No. 34 Table No.6}
Plot Frontage No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
FAR Area (1) In Old Area, for Residential Building on abutting roadwidth 7.5 (25 ft.) to 9.10 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15}
(2) For Jhumritilaiya Nagar Parishad, Max. 2.0 permissible FAR may be permitted for Residential Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Residential Building on abutting roadwidth 7.5 (25 ft.) to 9.10 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15}
(2) For Jhumritilaiya Nagar Parishad, Max. 2.0 permissible FAR may be permitted for Residential Use {As per Annexure III}
Common Plot Area In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
Common Plot (1) In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
(2) ;
Tree Number 4-8 Trees shall be required for the Plot area above 250.0 and upto 1000.0 sq.mt. (As per Rule No. 20.1.6)
Margin Rule For Non-highrise Residential Building 10-13.3 mt. Ht. having Plot Depth 21-27 mt. and Plot width 10-15 mt., Margin required in Front shall be 3.0 mt., Rear 2.25 mt. and 0.9 mt. shall be provided on both side. {As per Rule No. 36 (Table 8 & 9 and updated as per 4th Amendment dated 2nd Jan, 2019}
Building Level
Building Height For old area, on Road width 7.50-9.10 mt., Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 19.25 mt. {As per Rule No. 39.1 Table 15}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
Parapet Height (1) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
(2) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
(3) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
Floor Number For old area location,on Road width 7.5-9.1 mt. only G+5 floors shall be allowed {As per Rule No. 39.1 Table 15}
StairCase (1) Width of Winding staircase shall be mini. 0.90 mt.,Maximum rise 0.20 mt. & Minimum tread 0.25 mt. & Cabin Height 2.1 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) No Rule Defined
(4) ; No Rule Defined
Plot / Building Level
Accessory Use (1) -
(2) No need to check distance from Building SUMP TANK
(3) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(4) No need to check distance from Building RAIN WATER HARVESTING
(5) -
(6) No need to check distance from Building SOLAR HEATING SYSTEM
Accessory Use Number Provision of Rain Water Harvesting shall be mandatory for any use {Updated as per JBBL, Amendment VIII dated 16/03/2021} Rain Water Harvesting
Building Level (Rooms)
Foyer3.02x1.37 No Rule Defined
Hall3.83x6.33 No Rule Defined
Kitchen2.64x2.44 Area for Kitchen shall be Mini. 5.0 sq.mt. having side mini. 1.8 mt. {Rule No. 42.3.2}
Puja2.64x1.37 No Rule Defined
Room3.25x3.72 No Rule Defined
Room3.35x3.72 No Rule Defined
Room4.27x6.43 No Rule Defined
Toilet1.37x3.72 Area for Toilet shall be Mini. 2.8 sq.mt. having side mini. 1.2 mt. {Rule No. 42.4.2}
Toilet2.31x1.37 Area for Toilet shall be Mini. 2.8 sq.mt. having side mini. 1.2 mt. {Rule No. 42.4.2}