General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictLOHARDAGA
AuthorityLOHARDAGA NAGAR PARISHAD
Inward_NoLNP/BP/0002/W21/2018/ALT1
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentAddition or Alteration
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillageLohardaga
Taluka26
Layout Sanction No127
Layout Sanction Date4/2/2017
Architect Details
Architect NameASHWINI KUMAR SAHU
License No.LNP/ENG/0005/2017
Architect AddressNear check post, PWD Road
Architect EmailIDerashwinisahu@gmail.com
Architect Mobile No9308730823
Plot Details
Plot Use Residential
Plot SubUse Residential Bldg/Apartment
PlotNearbyReligiousStructure NA
Plot/SubPlot No1267
North -
South -
East -
West -
Owner's Details
NameMR SHAILESH KUMAR SINGH
AddressCHHATAR BAGICHA LOHARDAGA
Email IDerashwinisahu@gmail.com
Mobile No7488812570
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 271.43
2 Plot area as per Document by Applicant 271.43
3 Physical area measured at site 271.43
4 Area as per Site Visit (Site Visit Report) 271.43
5Area as per Drawing 271.43

Area of Plot Considered : 271.43

Plot area provided in drawing shall not be more than Plot area as per Document.
[-] Table 2b
Proposal Detail :
UnitMeters
Development Detail :
PlotPLOT
Plot OccupancyResidential
Plot SubUse Residential Bldg/Apartment
Building StructureNon-Highrise
Building TypeSingle Detached House
Gross Plot Area 271.43
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 271.43
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 242.94
Deductions for Balance Plot Area (from Gross Plot Area)
- Common Plot 28.49
28.49
Balance Plot Area 242.94

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 60.00 % ) 162.86
Proposed Coverage Area ( 58.19 % ) 157.95
Total Prop. Coverage Area ( 58.19 % ) 157.95
Balance coverage area ( 1.81 % ) 4.91
FAR CHECK
Perm. FAR Area ( 2.00 ) 542.86
Total Perm. FAR area 542.86
Residential FAR 435.04
Proposed FAR Area 447.71
Total Proposed FAR Area 447.71
Consumed FAR (Factor) 1.65
Balance FAR Area 95.15
BUA CHECK
Total Proposed BuiltUp Area 631.80


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Exceeding 1000 meter -
Existing Road Width 10 10.00
Proposed Road Width as per Master Plan 11.2 -
Road Widening Width 0.6 -
Plot size (as per measurement) 271.43 271.43


Plot Related Details
Name Description Unit Reqd Perm Proposed Status
PLOT Plot Area Sq.Mt. - - 271.43 OK
Plot Width Sq.Mt. - - 10.24 OK
Plot Depth Sq.Mt. - - 26.52 OK
Access Width Sq.Mt. - - 10.00 OK
Plot Frontage Sq.Mt. - - 10.67 OK
Coverage Area Sq.Mt. - 162.86 157.95 OK
FAR Area Sq.Mt. - 542.86 447.71 OK
Consumed FAR Sq.Mt. - 2.00 1.65 OK
Common Plot Checks Common Plot - Total Area Sq.Mt. 27.14 28.49 OK
Common Plot Tree Cover (Plantation) - Minimum Area Sq.Mt. - 28.49 OK
Tree Cover (Plantation) - Coverage Area Sq.Mt. - - OK
Tree Cover (Plantation) - Width Mt. - 1.40 OK
Tree Cover (Plantation) - Angle Degree - 89.67 OK
Tree Cover (Plantation) - Access Mt. - OK
Tree Tree - Nos Of Trees No. 4 15 OK
A-1 (MR SHAILESH KUMAR SINGH) Front Margin... 10.0 MTR WIDE ROAD Access Road Mt. 3.00 - 3.20 OK
Rear Margin Mt. 1.80 - 3.64 OK
Side1 Margin Mt. 0.90 - 0.91 OK
Side2 Margin Mt. 0.90 - 0.99 OK
A-1 (MR SHAILESH KUMAR SINGH) Basement Front Margin... 10.0 MTR WIDE ROAD Access Road Mt. 3.00 - 3.20 OK
Basement Rear Margin Mt. 1.80 - 3.64 OK
Basement Side1 Margin Mt. 0.90 - 0.91 OK
Basement Side2 Margin Mt. 0.90 - 0.99 OK

Building Related Details
Name Description Unit Reqd Perm Proposed Status
A (MR SHAILESH KUMAR SINGH) Height Mt. 18.20 8.55 OK
A (MR SHAILESH KUMAR SINGH) Second Floor - Height Mt. 2.60 - 2.85 OK
First Floor - Height Mt. 2.60 - 2.85 OK
Ground Floor - Height Mt. 2.60 - 2.85 OK
Basement Floor - Height Mt. 2.40 - 2.86 OK
Plinth - Height Mt. 0.45 - 0.81 OK
A (MR SHAILESH KUMAR SINGH) Terrace Floor - Height Mt. 1.00 1.20 1.07 OK
A (MR SHAILESH KUMAR SINGH) Basement Floor - Height Below GL Mt. - 1.64 OK
Basement Floor - Area Sq.Mt. - 157.95 OK
Basement Floor - Ventilation Area (Sq.mt.) Sq.Mt. - - OK
A (MR SHAILESH KUMAR SINGH) Area Sq.Mt. - 157.95 OK
Status - OK
Total Area Sq.Mt. - 157.95 OK
A (MR SHAILESH KUMAR SINGH) No. of Basement Floor No. 1 1 OK
A (MR SHAILESH KUMAR SINGH) No. of Floors No. G + 6 3 OK
No. of Tenements No. - 1 OK
A (MR SHAILESH KUMAR SINGH) Number Of Lift(s) No. - 2 OK
A (MR SHAILESH KUMAR SINGH) GROUND FLOOR PLAN - Lift - Width Mt. 1.70 1.89 OK
GROUND FLOOR PLAN - Lift - Depth Mt. 1.90 2.09 OK
TERRACE FLOOR PLAN - Lift Machine Room - Width Mt. 1.70 1.89 OK
TERRACE FLOOR PLAN - Lift Machine Room - Depth Mt. 1.90 2.09 OK
SECOND FLOOR PLAN - Lift - Width Mt. 1.70 1.89 OK
SECOND FLOOR PLAN - Lift - Depth Mt. 1.90 2.09 OK
GROUND FLOOR PLAN STAIRCASE - Flight Width Mt. 0.900 0.910 OK
STAIRCASE - Tread Width Mt. 0.250 0.250 OK
STAIRCASE - Riser Height Mt. 0.200 0.158 OK
STAIRCASE - Riser No. On Flight No. - 7 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
TERRACE FLOOR PLAN Staircase -3FL - Flight Width Mt. - 0.914 OK
Staircase -3FL - Tread Width Mt. - 0.250 OK
Staircase -3FL - Riser Height Mt. - - OK
Staircase -3FL - Riser No. On Flight No. - - OK
Staircase -3FL - Cabin Ht. Mt. - - 2.430 OK
SECOND FLOOR PLAN Staircase -3FL - Flight Width Mt. 0.900 0.914 OK
Staircase -3FL - Tread Width Mt. 0.250 0.250 OK
Staircase -3FL - Riser Height Mt. 0.200 0.095 OK
Staircase -3FL - Riser No. On Flight No. - 8 OK
Staircase -3FL - Cabin Ht. Mt. - - - OK
Sewage Treatment Plant Area Sq.Mt. - - 0.91 OK
Width Mt. - - 0.76 OK
Depth Mt. - - 1.21 OK
Height Mt. - - - OK
RAIN WATER HARVESTING Area Sq.Mt. - - 2.49 OK
Width Mt. - - 1.21 OK
Depth Mt. - - 2.06 OK
Height Mt. - - - OK
SOLAR HEATING SYSTEM Area Sq.Mt. - - 1.28 OK
Width Mt. - - 0.91 OK
Depth Mt. - - 1.40 OK
Height Mt. - - - OK
All Rooms are as per Rule in Room Checking




[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use
Plot Width No rule provided for Min. Plot size for proposed Use
Plot Depth No rule provided for Min. Plot size for proposed Use
Access Width The minimum width of abutting road for any Building shall be with respect to Length of Road {As per Rule No. 34 Table No.6}
Plot Frontage No rule provided for Min. Plot size for proposed Use
FAR Area (1) In Old Area, for Residential Building on abutting roadwidth 9.10 (30 ft.) to 12.20 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15}
(2) For Lohardaga Nagar Parishad Max. 2.0 permissible FAR may be permitted for Residential Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Residential Building on abutting roadwidth 9.10 (30 ft.) to 12.20 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15}
(2) For Lohardaga Nagar Parishad Max. 2.0 permissible FAR may be permitted for Residential Use {As per Annexure III}
Common Plot Area In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
Common Plot (1) In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
(2) ;
Tree Number 4-8 Trees shall be required for the Plot area above 250.0 and upto 1000.0 sq.mt. (As per Rule No. 20.1.6)
Margin Rule For Non-highrise Residential Building upto 10.0 mt. Ht. having Plot Depth 21-27 mt. and Plot width 10-15 mt., Margin required in Front shall be 3.0 mt., Rear 1.8 mt. and 0.9 mt. shall be provided on both side. {As per Rule No. 36 (Table 8 & 9)}
Basement Margin Rule In case of apartment/ group housing/commercial building and basements may be allowed to be constructed under the entire plot area leaving mini. 3 mt. space from the boundary of the premises {As per Rule No. 48}
Building Level
Building Height For old area, on Road width 9.10-12.20 mt., Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 23.10 mt. {As per Rule No. 39.1 Table 15}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.6m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab) for Low income Housing {As per IS Rule No.8888-1978}
(2) The height of all rooms for human habitation shall not be less than 2.6m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab) for Low income Housing {As per IS Rule No.8888-1978}
(3) The height of all rooms for human habitation shall not be less than 2.6m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab) for Low income Housing {As per IS Rule No.8888-1978}
(4) The height of all rooms for human habitation shall not be less than 2.6m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab) for Low income Housing {As per IS Rule No.8888-1978}
(5) o Every basement shall be in every part at least 2.4 m. in height from the floor to the soffit of the roof slab or ceiling and mini. Of 2.1 mr. below the soffit of beams {As per Rule No. 48}
(6) The plinth or any part of a building shall be so located with respect to the surrounding ground level that adequate drainage of the site is assured. The height of the plinth (except in case of stilted parking) shall be not less than 0.45 mt. from the surrounding ground level {As per Rule No. 42.10}
Parapet Height Parapet walls and handrails provided on the edges of roof terraces, balcony, verandah, etc shall not be less than 1.0 m and not more than 1.2 m in height from the finished floor level {As per Rule No. 42.5}
Below GL Floor Height ,
Basement Floor No. Individual residential and small commercial buildings, plot size upto minimum 750 Sq. Meter may have one basement {As per Rule No. 48}
Floor Number For old area location,on Road width 9.1-12.20 mt. only G+6 floors shall be allowed {As per Rule No. 39.1 Table 15}
Lift Count (1) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(2) For Residential Building height upto 12.0 mt., for every 16 flats or upto G+4 floors, No Lift is reqd. {As per Rule No. 49.1.2}
Lift (1) The area of lift well at one floor only (not the sum of total area of lift well at every floor) shall be counted for F.A.R calculation)
(2) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(3) -
(4) The area of lift well shall not be counted for F.A.R calculation)
(5) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
StairCase (1) Width of Winding staircase shall be mini. 0.90 mt.,Maximum rise 0.20 mt. & Minimum tread 0.25 mt. & Cabin Height 2.1 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) No Rule Defined
(4) ; No Rule Defined
Plot / Building Level
Accessory Use (1) -
(2) No need to check distance from Building Sewage Treatment Plant
(3) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(4) No need to check distance from Building RAIN WATER HARVESTING
(5) -
(6) No need to check distance from Building SOLAR HEATING SYSTEM
Building Level (Rooms)