No Image Found

Check List Report

Lohardaga Nagar Parishad

Version Number: 1.0.30
Version Date: 30/06/2018
Report Generated On: 11-12-2018

[-] Collapse All


General Details
Region JHARKHAND URBAN LOCAL BODIES
District LOHARDAGA
Authority LOHARDAGA NAGAR PARISHAD
Inward_No LNP/BP/0040/W18/2018
Application Type General Proposal
Project Type Building Permission
Nature of Development New
Location of Development Area Old Area
City Area/TPScheme No NA
Village Lohardaga
Taluka 26
Architect Details
Architect Name SUNIL KUMAR
License No. LNP/ENG/0004/2017
Architect Address BARWATOLI
Architect EmailID sunil7527@gmail.com
Architect Mobile No 9097161889
Plot Details
Plot Use Residential
Plot SubUse Bungalow/ Dwelling / Non Apartment
PlotNearbyReligiousStructure NA
Plot/SubPlot No 1255
North -
South -
East -
West -
Owner's Details
Name SRI JAYANT KUMAR SINGH
Address LOHARDAGA
Email ID sunil75277527@gmail.com
Mobile No 9110111465
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 301.93
2 Plot area as per Document by Applicant 301.93
3 Physical area measured at site 301.93
4 Area as per Site Visit (Site Visit Report) 301.93
5 Area as per Drawing 301.93

Area of Plot Considered : 301.93

Plot area provided in drawing shall not be more than Plot area as per Document.
[-] Table 2b
Proposal Detail :
Unit Meters
Development Detail :
Plot PLOT
Plot Occupancy Residential
Plot SubUse Bungalow/ Dwelling / Non Apartment
Building Structure Non-Highrise
Building Type Single Detached House
Gross Plot Area 301.93
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 301.93
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 265.22
Deductions for Balance Plot Area (from Gross Plot Area)
- Common Plot 36.71
36.71
Balance Plot Area 265.22

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 60.00 % ) 181.16
Proposed Coverage Area ( 25.77 % ) 77.81
Total Prop. Coverage Area ( 25.77 % ) 77.81
Balance coverage area ( 34.23 % ) 103.35
FAR CHECK
Perm. FAR Area ( 2.00 ) 603.86
Total Perm. FAR area 603.86
Residential FAR 155.62
Proposed FAR Area 155.62
Total Proposed FAR Area 155.62
Consumed FAR (Factor) 0.52
Balance FAR Area 448.24
BUA CHECK
Total Proposed BuiltUp Area 155.62


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Exceeding 1000 meter -
Existing Road Width 12 12.00
Proposed Road Width as per Master Plan 12 -
Road Widening Width 0 -
Plot size (as per measurement) 301.93 301.93


Plot Related Details
Name Description Unit Reqd Perm Proposed Status
PLOT Plot Area Sq.Mt. - - 301.93 OK
Plot Width Sq.Mt. - - 9.91 OK
Plot Depth Sq.Mt. - - 30.48 OK
Access Width Sq.Mt. - - 12.00 OK
Plot Frontage Sq.Mt. - - 10.67 OK
Coverage Area Sq.Mt. - 181.16 77.81 OK
FAR Area Sq.Mt. - 603.86 155.62 OK
Consumed FAR Sq.Mt. - 2.00 0.52 OK
Common Plot Checks Common Plot - Total Area Sq.Mt. 15.10 36.71 OK
Common Plot Tree Cover (Plantation) - Minimum Area Sq.Mt. - 36.71 OK
Tree Cover (Plantation) - Coverage Area Sq.Mt. - - OK
Tree Cover (Plantation) - Width Mt. - 4.10 OK
Tree Cover (Plantation) - Angle Degree - 90.00 OK
Tree Cover (Plantation) - Access Mt. - OK
Tree Tree - Nos Of Trees No. 4 10 OK
A-1 (SRI JAYANT KUMAR SINGH) Front Margin... 12.0 MTR WIDE ROAD Access Road Mt. 4.00 - 6.33 OK
Rear Margin Mt. 2.50 - 14.10 OK
Side1 Margin Mt. - - 1.05 OK
Side2 Margin Mt. 0.90 - 1.06 OK

Building Related Details
Name Description Unit Reqd Perm Proposed Status
A (SRI JAYANT KUMAR SINGH) Height Mt. 23.10 6.10 OK
A (SRI JAYANT KUMAR SINGH) First Floor - Height Mt. 2.75 - 3.05 OK
Ground Floor - Height Mt. 2.75 - 3.05 OK
Plinth - Height Mt. 0.45 - 0.61 OK
A (SRI JAYANT KUMAR SINGH) Terrace Floor - Height Mt. 1.00 1.20 1.08 OK
A (SRI JAYANT KUMAR SINGH) No. of Floors No. G + 6 2 OK
No. of Tenements No. - 1 OK
GROUND FLOOR PLAN STAIRCASE - Flight Width Mt. 0.750 1.054 OK
STAIRCASE - Tread Width Mt. 0.225 0.250 OK
STAIRCASE - Riser Height Mt. 0.200 0.152 OK
STAIRCASE - Riser No. On Flight No. - 10 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
FIRST FLOOR PLAN STAIRCASE - Flight Width Mt. 0.750 1.054 OK
STAIRCASE - Tread Width Mt. 0.225 0.250 OK
STAIRCASE - Riser Height Mt. 0.200 0.152 OK
STAIRCASE - Riser No. On Flight No. - 10 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
TERRACE FLOOR PLAN STAIRCASE - Flight Width Mt. - 1.054 OK
STAIRCASE - Tread Width Mt. - 0.250 OK
STAIRCASE - Riser Height Mt. - - OK
STAIRCASE - Riser No. On Flight No. - - OK
STAIRCASE - Cabin Ht. Mt. 2.100 - 2.743 OK
Sewage Treatment Plant Area Sq.Mt. - - 0.90 OK
Width Mt. - - 0.80 OK
Depth Mt. - - 1.13 OK
Height Mt. - - - OK
RAIN WATER HARVESTING Area Sq.Mt. - - 7.81 OK
Width Mt. - - 1.91 OK
Depth Mt. - - 4.08 OK
Height Mt. - - - OK
ENT.GATE Area Sq.Mt. - - 1.98 OK
Width Mt. - - 0.57 OK
Depth Mt. - - 3.46 OK
Height Mt. - - - OK
SOLAR HEATING SYSTEM Area Sq.Mt. - - 5.01 OK
Width Mt. - - 1.93 OK
Depth Mt. - - 2.60 OK
Height Mt. - - - OK
A (SRI JAYANT KUMAR SINGH) Rain Water Harvesting - No No. 1 - 1 OK
All Rooms are as per Rule in Room Checking




[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use
Plot Width No rule provided for Min. Plot size for proposed Use
Plot Depth No rule provided for Min. Plot size for proposed Use
Access Width The minimum width of abutting road for any Building shall be with respect to Length of Road {As per Rule No. 34 Table No.6}
Plot Frontage No rule provided for Min. Plot size for proposed Use
FAR Area (1) In Old Area, for Residential Building on abutting roadwidth 9.10 (30 ft.) to 12.20 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15}
(2) For Lohardaga Nagar Parishad Max. 2.0 permissible FAR may be permitted for Residential Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Residential Building on abutting roadwidth 9.10 (30 ft.) to 12.20 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15}
(2) For Lohardaga Nagar Parishad Max. 2.0 permissible FAR may be permitted for Residential Use {As per Annexure III}
Common Plot Area In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
Common Plot (1) In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
(2) ;
Tree Number 4-8 Trees shall be required for the Plot area above 250.0 and upto 1000.0 sq.mt. (As per Rule No. 20.1.6)
Margin Rule For Non-highrise Residential Building upto 10.0 mt. Ht. having Plot Depth 27-33 mt. and Plot width upto 10 mt., Margin required in Front shall be 4.0 mt., Rear 2.5 mt. and Atleast 0.9 mt. shall be provided at one side. {As per Rule No. 36 (Table 8 & 9)}
Building Level
Building Height For old area, on Road width 9.10-12.20 mt., Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 23.10 mt. {As per Rule No. 39.1 Table 15}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(3) The plinth or any part of a building shall be so located with respect to the surrounding ground level that adequate drainage of the site is assured. The height of the plinth (except in case of stilted parking) shall be not less than 0.45 mt. from the surrounding ground level {As per Rule No. 42.10}
Parapet Height Parapet walls and handrails provided on the edges of roof terraces, balcony, verandah, etc shall not be less than 1.0 m and not more than 1.2 m in height from the finished floor level {As per Rule No. 42.5}
Floor Number For old area location,on Road width 9.1-12.20 mt. only G+6 floors shall be allowed {As per Rule No. 39.1 Table 15}
StairCase (1) Width of Winding staircase shall be mini. 0.75 mt.,Maximum rise 0.20 mt. & Minimum tread 0.225 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) Width of Winding staircase shall be mini. 0.75 mt.,Maximum rise 0.20 mt. & Minimum tread 0.225 mt. & Cabin height 2.1 mt {As per Rule No. 83.18}
(4) ; No Rule Defined
Plot / Building Level
Accessory Use (1) -
(2) No need to check distance from Building Sewage Treatment Plant
(3) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(4) No need to check distance from Building RAIN WATER HARVESTING
(5) No need to check distance from Building ENT.GATE
(6) -
(7) No need to check distance from Building SOLAR HEATING SYSTEM
Accessory Use Number Provision of rainwater harvesting shall be mandatory for 300 sqm. and above size of plots-The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area Rain Water Harvesting
Building Level (Rooms)