Detail Scrutiny Report

Lohardaga Nagar Parishad

Version Number: 1.0.29
Version Date: 30/06/2018
Report Generated On: 22-10-2018

[-] Collapse All


General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictLOHARDAGA
AuthorityLOHARDAGA NAGAR PARISHAD
Inward_NoLNP/BP/0024/W16/2018
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentNew
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillageLohardaga
Taluka26
Architect Details
Architect NameASHWINI KUMAR SAHU
License No.LNP/ENG/0005/2017
Architect AddressNear check post, PWD Road
Architect EmailIDerashwinisahu@gmail.com
Architect Mobile No9308730823
Plot Details
Plot Use Residential
Plot SubUse Residential Bldg/Apartment
PlotNearbyReligiousStructure NA
Plot/SubPlot No2729/2733/2734
North -
South -
East -
West -
Owner's Details
NameOM PRAKASH SAHU/JAY PRAKASH SAHU
AddressLOHARDAGA
Email IDerashwinisahu@gmail.com
Mobile No9162343377
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 145.28
2 Plot area as per Document by Applicant 145.28
3 Physical area measured at site 145.28
4 Area as per Site Visit (Site Visit Report) 145.28
5Area as per Drawing 145.28

Area of Plot Considered : 145.28

[-] Table 2b
Proposal Detail :
UnitMeters
Development Detail :
PlotPLOT
Plot OccupancyResidential
Plot SubUse Residential Bldg/Apartment
Building StructureNon-Highrise
Building TypeSingle Detached House
Gross Plot Area 145.28
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 145.28
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 129.20
Deductions for Balance Plot Area (from Gross Plot Area)
- Common Plot 16.08
16.08
Balance Plot Area 129.20

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 70.00 % ) 101.70
Proposed Coverage Area ( 52.50 % ) 76.27
Total Prop. Coverage Area ( 52.5 % ) 76.27
Balance coverage area ( 17.50 % ) 25.43
FAR CHECK
Perm. FAR Area ( 1.80 ) 261.50
Total Perm. FAR area 261.50
Residential FAR 238.85
Proposed FAR Area 238.85
Total Proposed FAR Area 238.85
Consumed FAR (Factor) 1.64
Balance FAR Area 22.65
BUA CHECK
Total Proposed BuiltUp Area 238.85


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Exceeding 1000 meter -
Existing Road Width 6 6.00
Proposed Road Width as per Master Plan 10 -
Road Widening Width 5 -
Plot size (as per measurement) 145.28 145.28




[-] Plot Level Checking (Table 3)

[-] Common Plot Checks (Table 3b)
Name Total Area Status
Reqd Prop
Common Plot 14.53 16.08 OK


[-] Common Plot Checks (Table 3b)
Name Minimum Area Coverage Area Width Angle Access Status
Reqd Prop Perm Prop Reqd Prop Reqd Prop
Tree Cover (Plantation) - 16.08 0.00 0.00 - 3.56 - 50.21 No Access Provided OK




[-] Tree Details (Table 3g)
Name Nos Of Trees Status
Reqd Prop
Tree 2 8 OK





[-] Building Details (Table 4)

[-] Building USE/SUBUSE Details Building USE/SUBUSE Details
Building Name Building Use Building SubUse Building Structure
A (OM PRAKASH SAHU JAY PRAKASH SAHU) Residential Residential Bldg/Apartment Non-Highrise



[-] Height Details (4a)



[-] Total Height (Table 4a-1)
Building Height Height (From GL) Height (From Street LVL) Status
Perm Prop
A (OM PRAKASH SAHU JAY PRAKASH SAHU) 10.00 9.02 9.02 9.02 OK




[-] Floor Height Check (Table 4a-2)
Building Name Floor Name Height Status
Reqd Perm Prop
A (OM PRAKASH SAHU JAY PRAKASH SAHU) Second Floor 2.75 - 3.01 OK
First Floor 2.75 - 3.01 OK
Ground Floor 2.75 - 3.01 OK
Plinth 0.45 - 0.84 OK


[-] Parapet Height Check (Table 4a-2.1)
Building Name Floor Name Height Status
Reqd Perm Prop
A (OM PRAKASH SAHU JAY PRAKASH SAHU) Terrace Floor 1.00 1.20 1.08 OK


[-] Floor Number Check (Table 4a-4)
Building Name No. of Floors No. of Tenements Status
Perm Prop Perm Prop
A (OM PRAKASH SAHU JAY PRAKASH SAHU) G + 2 3 - 1 OK


[-] Coverage Check (Table 4b)
Permissible Proposed Status
101.70 76.27 OK
70% 52.5%

[-] Individual Coverage Check
Coverage Area Perm. Prop.
A-1 (OM PRAKASH SAHU JAY PRAKASH SAHU) - 76.27
Total Prop. Coverage Area - 76.27
Total Coverage Area 101.70 76.27


[-] FAR & Tenement Details (Table 4c-1)
Building No. of Same Bldg Total Built Up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
Resi.
A (OM PRAKASH SAHU JAY PRAKASH SAHU) 1 238.85 238.85 238.85 238.85 01
Grand Total : 1 238.85 238.85 238.85 238.85 01


[-] Buildingwise Floor FAR Details
Floor Name Building Name Total
A (OM PRAKASH SAHU JAY PRAKASH SAHU)
Proposed Built Up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Total Proposed Built Up Area (Sq.mt.) Total FAR Area (Sq.mt.)
Ground Floor 76.27 76.27 76.27 76.27
First Floor 81.29 81.29 81.29 81.29
Second Floor 81.29 81.29 81.29 81.29
Terrace Floor 0.00 0.00 0.00 0.00
Total : 238.85 238.85 238.85 238.85


[-] UnitBUA Table for Building :A (OM PRAKASH SAHU JAY PRAKASH SAHU) UnitBUA CALCULATION
FLOOR Name UnitBUA Type UnitBUA Area Carpet Area No. of Rooms No. of Tenement
GROUND FLOOR PLAN SPLIT A FLAT 150.55 150.18 4 1
FIRST FLOOR PLAN SPLIT A FLAT 0.00 0.00 7 0
SECOND FLOOR PLAN SPLIT A FLAT 0.00 0.00 7 0
Total: - - 150.55 150.18 18 1


[-] Building :A (OM PRAKASH SAHU JAY PRAKASH SAHU)
Floor Name Total Built Up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
Resi.
Ground Floor 76.27 76.27 76.27 76.27 01
First Floor 81.29 81.29 81.29 81.29 00
Second Floor 81.29 81.29 81.29 81.29 00
Terrace Floor 0.00 0.00 0.00 0.00 00
Total : 238.85 238.85 238.85 238.85 01
Total Number of Same Buildings : 1
Total : 238.85 238.85 238.85 238.85 01

[-] Table 4c-2

FARArea
Building FAR Area:238.85
Existing FAR Area :0.00
Perm.
261.50
Prop.
238.85
Status
OK





[-] Margin Checks (Table 5)
[-] Plot Margin (Table 5a)
Building / Wing Road Name Front Side Rear Side Side1 Side2 Status
Reqd. Prop. Reqd. Prop. Reqd. Prop. Reqd. Prop.
A-1 (OM PRAKASH SAHU JAY PRAKASH SAHU) 6.0 MTR WIDE ROAD Access Road 4.00 4.75 2.50 4.51 1.00 0.00 1.00 0.92 Failed


[-] BldgLine Margin (Table 5a-1)
Building/Wing Front Side Reqd. Prop. Main Road Name ResvRoad Name Reqd. Width Prop. Width Status
A-1 (OM PRAKASH SAHU JAY PRAKASH SAHU) BldgLine for 6.0 MTR WIDE ROAD Access Road 0.75 4.75 6.0 MTR WIDE ROAD Access Road 0.75 0.00 Failed






[-] Inner Building Details (Table 6)


No OTS/Duct/VShaft/Balcony/Passage/Lift/Tenements Found.



[-] Parking Details (Table 7)


NO PARKING CHECK REQUIRED FOR SINGLE DWELLING UNIT. Residential Bldg/Apartment, In Building: A (OM PRAKASH SAHU JAY PRAKASH SAHU)



[-] Exemption Details (Table 8)



Not Required to Check StairCase Number Rule.


[-] Staircase Checks (Table 8a-1)


[-] For Building :A (OM PRAKASH SAHU JAY PRAKASH SAHU)
Floor Name StairCase Name Flight Width Tread Width Riser Height Riser No. On Flight Cabin Ht. Status
Reqd Prop Reqd Prop Perm Prop Perm Prop Reqd Perm Prop
GROUND FLOOR PLAN Staircase -3FL 0.900 0.991 0.250 0.254 0.200 0.088 - 16 - - 0.000 OK
FIRST FLOOR PLAN Staircase -3FL 0.900 0.991 0.250 0.254 0.200 0.088 - 16 - - 0.000 OK
SECOND FLOOR PLAN Staircase -3FL 0.900 0.991 0.250 0.254 0.200 0.088 - 16 - - 0.000 OK
TERRACE FLOOR PLAN Staircase -3FL - 0.991 - 0.254 - 0.000 - 0 - - 2.746 OK



[-] Accessory Use Check (Table 8d)
Accessory Use Name Area Width Depth Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
Sewage Treatment Plant - - 0.92 - - 0.88 - - 1.05 - - 0.00 OK
RAIN WATER HARVESTING - - 1.89 - - 1.20 - - 1.57 - - 0.00 OK
SOLAR HEATING SYSTEM - - 1.15 - - 0.96 - - 1.20 - - 0.00 OK






[-] Floor Details (Table 9)


[-] Building:A (OM PRAKASH SAHU JAY PRAKASH SAHU)


[-] Floor:GROUND FLOOR PLAN



All Dimensions and Area of all the Rooms on this Floor are as per the Rules.

[-] Floor:FIRST FLOOR PLAN



Not Required to Check Dimensions and Area of all the Rooms on this Floor Rule.

[-] Floor:SECOND FLOOR PLAN



All Dimensions and Area of all the Rooms on this Floor are as per the Rules.





[-] Summary (Table 10)

Name Perm./Reqd. Proposed Status
Plot Area - 145.28 OK
Plot Width - 5.17 OK
Plot Depth - 28.12 OK
Access Width - 6.00 OK
Plot Frontage - 4.57 OK
Coverage Area 101.70 76.27 OK
FARArea
Bldg. FAR Area : 238.85
Sanctioned FAR Area :0.00
261.50 238.85 OK





[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use
Plot Width No rule provided for Min. Plot size for proposed Use
Plot Depth No rule provided for Min. Plot size for proposed Use
Access Width The minimum width of abutting road for any Building shall be with respect to Length of Road {As per Rule No. 34 Table No.6}
Plot Frontage No rule provided for Min. Plot size for proposed Use
FAR Area (1) In Old Area, for Residential Building on abutting roadwidth 4.80 (16 ft.) to 6.10 mt., the Floor Area Ratio-FAR shall be 1.8 {As per Rule No.39, Table 15}
(2) For Lohardaga Nagar Parishad Max. 2.0 permissible FAR may be permitted for Residential Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Residential Building on abutting roadwidth 4.80 (16 ft.) to 6.10 mt., the Floor Area Ratio-FAR shall be 1.8 {As per Rule No.39, Table 15}
(2) For Lohardaga Nagar Parishad Max. 2.0 permissible FAR may be permitted for Residential Use {As per Annexure III}
Common Plot Area In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
Common Plot (1) In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
(2) ;
Tree Number 2-4 Trees shall be required for the Plot area upto 250.0 sq.mt. (As per Rule No. 20.1.6)
Margin Rule For narrow plots,the setbacks on sides may be compensated in front and rear setbacks so as to ensure that the overall aggregate setbacks are maintained in the site, subject to maintaining a minimum of side setback of 1m in case of buildings of height up to 10.0 mt.
Building Line Check The min. width of Road for length of Road Exceeding 300 mt. shall be 7.50 mt. {As per Rule No. 34 Table No. 6}
ResvRoad Width Check The min. width of Road for length of Road Exceeding 300 mt. shall be 7.50 mt. {As per Rule No. 34 Table No. 6}
Building Level
Building Height For old area, on Road width 4.8-6.10 mt., Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 10.0 mt. {As per Rule No. 39.1 Table 15}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(3) The plinth or any part of a building shall be so located with respect to the surrounding ground level that adequate drainage of the site is assured. The height of the plinth (except in case of stilted parking) shall be not less than 0.45 mt. from the surrounding ground level {As per Rule No. 42.10}
Parapet Height Parapet walls and handrails provided on the edges of roof terraces, balcony, verandah, etc shall not be less than 1.0 m and not more than 1.2 m in height from the finished floor level {As per Rule No. 42.5}
Floor Number For old area location,on Road width 4.8-6.1 mt. only G+2 floors shall be allowed {As per Rule No. 39.1 Table 15}
StairCase (1) Width of Winding staircase shall be mini. 0.90 mt.,Maximum rise 0.20 mt. & Minimum tread 0.25 mt. & Cabin Height 2.1 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) No Rule Defined
(4) ; No Rule Defined
Plot / Building Level
Accessory Use (1) -
(2) No need to check distance from Building Sewage Treatment Plant
(3) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(4) No need to check distance from Building RAIN WATER HARVESTING
(5) -
(6) No need to check distance from Building SOLAR HEATING SYSTEM
Building Level (Rooms)