No Image Found   

Check List Report

Lohardaga Nagar Parishad

Version Number: 1.0.39  
Version Date: 29/04/2019 
Report Generated On: 05-08-2019 
 

[-] Collapse All


General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictLOHARDAGA
AuthorityLOHARDAGA NAGAR PARISHAD
Inward_NoLNP/BP/0018/W09/2019
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentNew
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillageNadia
Taluka26
Architect Details
Architect NameANUP KUMAR SINHA
License No.LNP/ARC/0001/2018
Architect Address3rd Floor, Roshpa Tower, Main Road, Ranchi
Architect EmailIDtheaksassociates@gmail.com
Architect Mobile No8986652248
Plot Details
Plot Use Mixed
Plot SubUse Residential Bldg/Apartment
PlotNearbyReligiousStructure NA
Plot/SubPlot No292, 293, 281
NorthPlot No. - 291
SouthPlot No. - 293
EastPlot No. - 285
WestRoad Width - 5.18
Owner's Details
NameDR. VIDYA BINOD PRASAD DR. SANJAY PD. MRS. URMILA PD. DR. SMRITI
AddressDr.(Capt) V. B. Prasad Clinic, in front of Sadar Hospital powergunj, Lohardaga
Email IDdrsanjayp64@gmail.com
Mobile No8210000782
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 873.71
2 Plot area as per Document by Applicant 873.71
3 Area as per Site Visit (Site Visit Report) 873.71
4Area as per Drawing 873.66

Area of Plot Considered : 873.66

[-] Table 2b
Proposal Detail :
UnitMeters
Development Detail :
PlotPLOT
Plot OccupancyMixed
Plot SubUse -
Higher Plot Use
Higher Plot Sub UseResidential Bldg/Apartment
Lower Plot Use
Lower Plot Sub Use
Building StructureNon-Highrise
Building TypeSingle Detached House
Gross Plot Area 873.66
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 873.66
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 726.07
Deductions for Balance Plot Area (from Gross Plot Area)
- Common Plot 147.59
147.59
Balance Plot Area 726.07

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 60.00 % ) 524.20
Proposed Coverage Area ( 29.77 % ) 260.09
Total Prop. Coverage Area ( 29.77 % ) 260.09
Balance coverage area ( 30.23 % ) 264.11
FAR CHECK
Perm. FAR Area ( 2.00 ) 1747.32
Additional FAR 436.83
Total Perm. FAR area 2184.15
Residential FAR 555.83
Special FAR 424.84
Proposed FAR Area 980.67
Total Proposed FAR Area 980.67
Consumed FAR (Factor) 1.12
Balance FAR Area 1203.48
BUA CHECK
Total Proposed BuiltUp Area 1208.08


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Exceeding 100 meter and upto 250 meter -
Existing Road Width 6.35 6.35
Proposed Road Width as per Master Plan 6.35 -
Road Widening Width 0 -
Plot size (as per measurement) 873.71 873.66
[-] Extra Land Area Checks
Name Area Status
Reqd Prop
Extra Land - 0.00 OK

     Extra Land Area Details
Name Description Unit Reqd Perm Proposed Status
Extra Land Area Details Extra Land Area - - 0.00 OK

     Plot Related Details
Name Description Unit Reqd Perm Proposed Status
PLOT Plot Area Sq.Mt. - - 873.66 OK
Plot Width Mt. - - 38.74 OK
Plot Depth Mt. - - 22.55 OK
Access Width Mt. - - 6.35 OK
Plot Frontage Mt. - - 40.19 OK
Coverage Area Sq.Mt. - 524.20 260.09 OK
FAR Area Sq.Mt. - 2184.15 980.67 OK
Consumed FAR Sq.Mt. - 2.00 1.12 OK
Common Plot Checks Common Plot - Total Area Sq.Mt. 87.37 147.59 OK
Common Plot Normal Open Space - Minimum Area Sq.Mt. - 70.28 OK
Normal Open Space - Access Mt. - OK
Normal Open Space - Minimum Area Sq.Mt. - 77.31 OK
Normal Open Space - Access Mt. - OK
Tree Tree - Nos Of Trees No. 4 8 OK
Car In Area Sq.Mt. - - 125.00 OK
Total Car In Area Sq.Mt. 25.00 - 125.00 OK
Visitor's Car Parking In Area Sq.Mt. - - 12.50 OK
Total Visitor Parking In Area Sq.Mt. 12.50 - 12.50 OK
Ambulance In Area Sq.Mt. - - 26.25 OK
TwoWheeler In Area Sq.Mt. - - 36.00 OK
Total TwoWheeler In Area Sq.Mt. 4.00 - 36.00 OK
A-1 (A2) Front Margin... 6.35 M WIDE ROAD Mt. 3.00 - 6.28 OK
Rear Margin Mt. 2.25 - 4.00 OK
Side1 Margin Mt. 3.00 - 4.00 OK
Side2 Margin Mt. 3.00 - 10.11 OK

     Building Related Details
Name Description Unit Reqd Perm Proposed Status
A (A2) Height Mt. 15.81 12.85 OK
A (A2) Third Floor - Height Mt. 2.75 - 3.00 OK
Third Floor - Clear Height Mt. 2.75 - 2.88 OK
Third Floor - Beam Clear Height Mt. 2.40 - 2.55 OK
Second Floor - Height Mt. 2.75 - 3.00 OK
Second Floor - Clear Height Mt. 2.75 - 2.88 OK
Second Floor - Beam Clear Height Mt. 2.40 - 2.55 OK
First Floor - Height Mt. 3.30 - 3.43 OK
First Floor - Clear Height Mt. 3.30 - 3.30 OK
First Floor - Beam Clear Height Mt. 2.40 - 3.30 OK
Ground Floor - Height Mt. 3.30 - 3.43 OK
Ground Floor - Clear Height Mt. 3.30 - 3.30 OK
Ground Floor - Beam Clear Height Mt. 2.40 - 3.30 OK
Plinth - Height Mt. 0.45 - 0.45 OK
Plinth - Clear Height Mt. - - 0.45 OK
Plinth - Beam Clear Height Mt. - - 0.45 OK
A (A2) Terrace Floor - Height Mt. 1.00 1.20 1.00 OK
A (A2) No. of Floors No. G + 4 4 OK
No. of Tenements No. - 4 OK
A (A2) TYPICAL - 2- 3 FLOOR PLAN - BALCONY - Width Mt. 1.20 0.20 OK
TYPICAL - 2- 3 FLOOR PLAN - BALCONY - Width Mt. 1.20 0.20 OK
TYPICAL - 2- 3 FLOOR PLAN - BALCONY - Width Mt. 1.20 1.13 OK
TYPICAL - 2- 3 FLOOR PLAN - BALCONY - Width Mt. 1.20 1.13 OK
TYPICAL - 2- 3 FLOOR PLAN - BALCONY - Width Mt. 1.20 1.20 OK
TYPICAL - 2- 3 FLOOR PLAN - BALCONY - Width Mt. 1.20 1.20 OK
A (A2) Number Of Lift(s) No. 1 1 OK
A (A2) GROUND FLOOR PLAN - Lift - Width Mt. 1.70 1.80 OK
GROUND FLOOR PLAN - Lift - Depth Mt. 1.90 3.05 OK
FIRST FLOOR PLAN - Lift - Width Mt. 1.70 1.80 OK
FIRST FLOOR PLAN - Lift - Depth Mt. 1.90 3.05 OK
TYPICAL - 2- 3 FLOOR PLAN - Lift - Width Mt. 1.70 1.80 OK
TYPICAL - 2- 3 FLOOR PLAN - Lift - Depth Mt. 1.90 3.05 OK
TERRACE FLOOR PLAN - Lift Machine Room - Width Mt. 1.70 1.80 OK
TERRACE FLOOR PLAN - Lift Machine Room - Depth Mt. 1.90 3.05 OK
GROUND FLOOR PLAN STAIRCASE - Flight Width Mt. 0.900 1.650 OK
STAIRCASE - Tread Width Mt. 0.250 0.300 OK
STAIRCASE - Riser Height Mt. 0.200 0.132 OK
STAIRCASE - Riser No. On Flight No. - 13 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
Fire Escape Staircase - Flight Width Mt. 0.900 1.050 OK
Fire Escape Staircase - Tread Width Mt. 0.250 0.300 OK
Fire Escape Staircase - Riser Height Mt. 0.200 0.163 OK
Fire Escape Staircase - Riser No. On Flight No. 16 9 OK
Fire Escape Staircase - Cabin Ht. Mt. - - - OK
FIRST FLOOR PLAN Fire Escape Staircase - Flight Width Mt. 0.900 1.050 OK
Fire Escape Staircase - Tread Width Mt. 0.250 0.300 OK
Fire Escape Staircase - Riser Height Mt. 0.200 0.163 OK
Fire Escape Staircase - Riser No. On Flight No. 16 9 OK
Fire Escape Staircase - Cabin Ht. Mt. - - - OK
STAIRCASE - Flight Width Mt. 0.900 1.650 OK
STAIRCASE - Tread Width Mt. 0.250 0.300 OK
STAIRCASE - Riser Height Mt. 0.200 0.132 OK
STAIRCASE - Riser No. On Flight No. - 13 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
TYPICAL - 2- 3 FLOOR PLAN Fire Escape Staircase - Flight Width Mt. 0.900 1.050 OK
Fire Escape Staircase - Tread Width Mt. 0.250 0.300 OK
Fire Escape Staircase - Riser Height Mt. 0.200 0.143 OK
Fire Escape Staircase - Riser No. On Flight No. 16 9 OK
Fire Escape Staircase - Cabin Ht. Mt. - - - OK
RAIN WATER HARVESTING Area Sq.Mt. - - 4.47 OK
Width Mt. - - 1.54 OK
Depth Mt. - - 2.91 OK
Height Mt. - - - OK
ENT.GATE Area Sq.Mt. - - 0.28 OK
Width Mt. - - 0.25 OK
Depth Mt. - - 1.19 OK
Height Mt. - - - OK
Entrance Lobby Area Sq.Mt. - 12.00 8.87 OK
Width Mt. - - 2.30 OK
Depth Mt. - - 3.86 OK
Height Mt. - - - OK
Area Sq.Mt. - 12.00 9.90 OK
Width Mt. - - 3.00 OK
Depth Mt. - - 3.30 OK
Height Mt. - - - OK
Area Sq.Mt. - 12.00 10.93 OK
Width Mt. - - 2.10 OK
Depth Mt. - - 5.21 OK
Height Mt. - - - OK
Area Sq.Mt. - 12.00 10.11 OK
Width Mt. - - 2.40 OK
Depth Mt. - - 4.21 OK
Height Mt. - - - OK
Area Sq.Mt. - 12.00 4.44 OK
Width Mt. - - 1.05 OK
Depth Mt. - - 4.23 OK
Height Mt. - - - OK
Area Sq.Mt. - 12.00 10.53 OK
Width Mt. - - 2.40 OK
Depth Mt. - - 4.39 OK
Height Mt. - - - OK
Area Sq.Mt. - 12.00 3.99 OK
Width Mt. - - 1.74 OK
Depth Mt. - - 2.30 OK
Height Mt. - - - OK
Area Sq.Mt. - 12.00 11.80 OK
Width Mt. - - 2.40 OK
Depth Mt. - - 4.92 OK
Height Mt. - - - OK
Area Sq.Mt. - 12.00 9.19 OK
Width Mt. - - 1.50 OK
Depth Mt. - - 6.13 OK
Height Mt. - - - OK
Area Sq.Mt. - 12.00 3.49 OK
Width Mt. - - 1.78 OK
Depth Mt. - - 2.53 OK
Height Mt. - - - OK
Area Sq.Mt. - 12.00 9.06 OK
Width Mt. - - 3.55 OK
Depth Mt. - - 4.03 OK
Height Mt. - - - OK
Area Sq.Mt. - 12.00 11.80 OK
Width Mt. - - 2.40 OK
Depth Mt. - - 4.92 OK
Height Mt. - - - OK
Area Sq.Mt. - 12.00 3.40 OK
Width Mt. - - 1.42 OK
Depth Mt. - - 2.40 OK
Height Mt. - - - OK
SOLAR HEATING SYSTEM Area Sq.Mt. - - 21.74 OK
Width Mt. - - 3.04 OK
Depth Mt. - - 7.15 OK
Height Mt. - - - OK
A (A2) Rain Water Harvesting - No No. 1 - 1 OK
Entrance Gate - No No. 1 - 1 OK
   
    All Rooms are as per Rule in Room Checking




[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use
Plot Width No rule provided for Min. Plot size for proposed Use
Plot Depth No rule provided for Min. Plot size for proposed Use
Access Width The minimum width of abutting road for any Building shall be with respect to Length of Road {As per Rule No. 34 Table No.6}
Plot Frontage No rule provided for Min. Plot size for proposed Use
FAR Area (1) In Old Area, for Non-Residential Building on abutting roadwidth 6.10 (20 ft.) to 7.5 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15 and modified as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
(2) For Lohardaga Nagar Parishad, Max. 2.0 permissible FAR may be permitted for Commercial or Mercantile type Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Non-Residential Building on abutting roadwidth 6.10 (20 ft.) to 7.5 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15 and modified as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
(2) For Lohardaga Nagar Parishad, Max. 2.0 permissible FAR may be permitted for Commercial or Mercantile type Use {As per Annexure III}
Common Plot Area In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
Common Plot (1) ;
(2) ;
(3) ; ;
Tree Number 4-8 Trees shall be required for the Plot area above 250.0 and upto 1000.0 sq.mt. (As per Rule No. 20.1.6)
Margin Rule For Non-highrise Residential Building 10-13.3 mt. Ht. having Plot Depth 21-27 mt. and Plot width 33-39 mt., Margin required in Front shall be 3.0 mt., Rear 2.25 mt. and 3.0 mt. shall be provided on both side. {As per Rule No. 36 (Table 8 & 9 and updated as per 4th Amendment dated 2nd Jan, 2019}
Building Level
Building Height For old area, on Road width 6.10-7.50 mt., Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 16.4 mt. {As per Rule No. 39.1 Table 15}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(3) For Educational Bulding, The height of all rooms shall not be less than 3.3 m measured from the surface of the floor to the lowest point of the ceiling
(4) For Educational Bulding, The height of all rooms shall not be less than 3.3 m measured from the surface of the floor to the lowest point of the ceiling
(5) The plinth or any part of a building shall be so located with respect to the surrounding ground level that adequate drainage of the site is assured. The height of the plinth (except in case of stilted parking) shall be not less than 0.45 mt. from the surrounding ground level {As per Rule No. 42.10}
Parapet Height Parapet walls and handrails provided on the edges of roof terraces, balcony, verandah, etc shall not be less than 1.0 m and not more than 1.2 m in height from the finished floor level {As per Rule No. 42.5}
Floor Number For old area location,on Road width 6.1-7.5 mt. only G+4 floors shall be allowed {As per Rule No. 39.1 Table 15}
Balcony For setback more than 2.5 meters projected balcony shall be allowed with a width of 1.2 meters {As per Rule No. 46.4}
Lift Count (1) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(2) For Residential Building height 12.0 mt. or above, upto G+4 floors or if the number of flats is upto 16, provision of lift will be compulsory. {As per Rule No. 49.1.2}
Lift (1) The area of lift well at one floor only (not the sum of total area of lift well at every floor) shall be counted for F.A.R calculation)
(2) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(3) The area of lift well shall not be counted for F.A.R calculation)
(4) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(5) -
StairCase (1) Width of Winding staircase shall be mini. 0.90 mt.,Maximum rise 0.20 mt. & Minimum tread 0.25 mt. & Cabin Height 2.1 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) Width of the Fire Stair case shall be mini. 0.90 mt.,Maximum rise 0.20 mt. & Minimum tread 0.25 mt. {As per Rule No. 43.5.3.6}
(4) ; Number of riser shall not exceed 16 per flight of stairs. {As per Rule No. 43.5.3.6}
Plot / Building Level
Accessory Use (1) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(2) No need to check distance from Building RAIN WATER HARVESTING
(3) No need to check distance from Building ENT.GATE
(4) Entrance Lobby of maximum size of 12 sq.m. shall be taken Free from FAR
(5) No need to check distance from Building Entrance Lobby
(6) -
(7) No need to check distance from Building SOLAR HEATING SYSTEM
Accessory Use Number (1) Provision of rainwater harvesting shall be mandatory for 300 sqm. and above size of plots-The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area Rain Water Harvesting
(2) In case of buildings with a height of 15.0 meters and above or ground coverage more than 500 sqm., the main entrance to the premise shall not be less than 5 (five) meters i n width in order to allow easy access to fire engine Entrance Gate
Building Level (Rooms)