-
No Image Found   

Check List Report

Lohardaga Nagar Parishad

Version Number: 1.0.66  
Version Date: 16/10/2020 
Report Generated On: 27-06-2023 
 

[-] Collapse All


General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictLOHARDAGA
AuthorityLOHARDAGA NAGAR PARISHAD
Inward_NoLNP/BP/0033/W03/2019/ALT2
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentAddition or Alteration
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillageNadia
Taluka26
Layout Sanction Date14/10/2019
Architect Details
Architect NameASHWINI KUMAR SAHU
License No.LNP/ENG/0005/2017
Architect AddressNear check post, PWD Road
Architect EmailIDerashwinisahu@gmail.com
Architect Mobile No9308730823
Plot Details
Plot Use Mixed
Plot SubUse Resi+Comm
PlotNearbyReligiousStructure NA
Plot/SubPlot No52
NorthRoad Width - 7.6
SouthPlot No. - 52
EastPlot No. - 52
WestPlot No. - 52
Owner's Details
NameSRI MALAY DUTTA SMT TANUJA DUTTA SMT DIPALI DUTTA
AddressGOPI NATH LANE LOHARDAGA
Email IDSOALOHARDAGA@GMAIL.COM
Mobile No7717797054
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 324.26
2 Plot area as per Document by Applicant 324.26
3 Physical area measured at site 324.26
4 Area as per Site Visit (Site Visit Report) 324.26
5Area as per Drawing 324.26

Area of Plot Considered : 324.26

Plot area provided in drawing shall not be more than Plot area as per Document.
[-] Table 2b
Proposal Detail :
Unit
Development Detail :
PlotPLOT
Plot OccupancyMixed
Plot SubUse -
Higher Plot Use
Higher Plot Sub UseResi+Comm
Lower Plot Use
Lower Plot Sub Use
Building StructureNon-Highrise
Building TypeSingle Detached House
Gross Plot Area 324.26
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 324.26
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 260.56
Deductions for Balance Plot Area (from Gross Plot Area)
- Common Plot 63.70
63.70
Balance Plot Area 260.56

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 60.00 % ) 194.56
Proposed Coverage Area ( 25.88 % ) 83.92
Total Prop. Coverage Area ( 25.88 % ) 83.92
Balance coverage area ( 34.12 % ) 110.64
FAR CHECK
Perm. FAR Area ( 2.000 ) 648.52
Total Perm. FAR area 648.52
Residential FAR 97.72
Commercial FAR 261.31
Proposed FAR Area 359.03
Total Proposed FAR Area 359.03
Consumed FAR (Factor) 1.11
Balance FAR Area 289.49
BUA CHECK
Total Proposed BuiltUp Area 371.76


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Exceeding 100 meter and upto 250 meter -
Existing Road Width 7.6 7.60
Proposed Road Width as per Master Plan 7.6 -
Road Widening Width 0 -
Plot size (as per measurement) 324.26 324.26
[-] Extra Land Area Checks
Name Area Status
Reqd Prop
Extra Land - 0.00 OK

     Extra Land Area Details
Name Description Unit Reqd Perm Proposed Status
Extra Land Area Details Extra Land Area - - 0.00 OK

     Plot Related Details
Name Description Unit Reqd Perm Proposed Status
PLOT Plot Area Sq.Mt. - - 324.26 OK
Plot Width Mt. - - 16.01 OK
Plot Depth Mt. - - 20.25 OK
Access Width Mt. - - 7.60 OK
Plot Frontage Mt. - - 16.10 OK
Coverage Area Sq.Mt. - 194.56 83.92 OK
FAR Area Sq.Mt. - 648.52 359.03 OK
Consumed FAR Sq.Mt. - 2.00 1.11 OK
Common Plot Checks Common Plot - Total Area Sq.Mt. 32.43 63.70 OK
Common Plot Tree Cover (Plantation) - Minimum Area Sq.Mt. - 63.70 OK
Tree Cover (Plantation) - Coverage Area Sq.Mt. - - OK
Tree Cover (Plantation) - Width Mt. - 4.02 OK
Tree Cover (Plantation) - Angle Degree - 89.25 OK
Tree Cover (Plantation) - Access Mt. - OK
Tree Tree - Nos Of Trees No. 4 14 OK
Car In Area Sq.Mt. - - 25.00 OK
Total Car In Area Sq.Mt. 12.50 - 52.00 OK
Parallel Car In Area Sq.Mt. - - 27.00 OK
Total Visitor Parking In Area Sq.Mt. 12.50 - 40.50 OK
Parallel Visitor's Car Parking In Area Sq.Mt. - - 40.50 OK
TwoWheeler In Area Sq.Mt. - - 12.00 OK
Total TwoWheeler In Area Sq.Mt. 2.00 - 12.00 OK
ERiksha Stand Area In Area Sq.Mt. - - 27.00 OK
DriveWay PLOT - - - DRIVEWAY - Width No. 3.60 - 3.80 OK
A-1 (SMT MALAY DUTTA AND SMT TANUJA DATTA AND SMT DIPALI DUTTA) Front Margin... 7.60 MTR WIDE MAINROAD Mt. 5.50 - 6.08 OK
Rear Margin Mt. 4.00 - 4.03 OK
Side1 Margin Mt. 2.50 - 2.52 OK
Side2 Margin Mt. 2.50 - 2.52 OK

     Building Related Details
Name Description Unit Reqd Perm Proposed Status
A (SMT MALAY DUTTA AND SMT TANUJA DATTA AND SMT DIPALI DUTTA) Height Mt. 17.48 12.19 OK
A (SMT MALAY DUTTA AND SMT TANUJA DATTA AND SMT DIPALI DUTTA) Third Floor - Height Mt. 2.75 - 3.05 OK
Third Floor - Clear Height Mt. 2.75 - 2.95 OK
Third Floor - Beam Clear Height Mt. 2.40 - 2.81 OK
Second Floor - Height Mt. 2.75 - 3.05 OK
Second Floor - Clear Height Mt. 2.75 - 2.95 OK
Second Floor - Beam Clear Height Mt. 2.40 - 2.81 OK
First Floor - Height Mt. 2.75 - 3.05 OK
First Floor - Clear Height Mt. 2.75 - 2.95 OK
First Floor - Beam Clear Height Mt. 2.40 - 2.81 OK
Ground Floor - Height Mt. 2.75 - 3.05 OK
Ground Floor - Clear Height Mt. 2.75 - 2.95 OK
Ground Floor - Beam Clear Height Mt. 2.40 - 2.81 OK
Plinth - Height Mt. 0.45 - 0.51 OK
Plinth - Clear Height Mt. - - 0.51 OK
Plinth - Beam Clear Height Mt. - - 0.51 OK
A (SMT MALAY DUTTA AND SMT TANUJA DATTA AND SMT DIPALI DUTTA) Terrace Floor - Height Mt. - - 1.07 OK
Terrace Floor - Clear Height Mt. - - 1.07 OK
Terrace Floor - Beam Clear Height Mt. - - 1.07 OK
A (SMT MALAY DUTTA AND SMT TANUJA DATTA AND SMT DIPALI DUTTA) No. of Floors No. G + 5 4 OK
No. of Tenements No. - 4 OK
A (SMT MALAY DUTTA AND SMT TANUJA DATTA AND SMT DIPALI DUTTA) Number Of Lift(s) No. - 1 OK
Number Of Strature Lift(s) No. - - OK
Capacity Of Lift(s) Passanger No. - 6 OK
A (SMT MALAY DUTTA AND SMT TANUJA DATTA AND SMT DIPALI DUTTA) THIRD FLOOR PLAN - Lift - Width Mt. 1.70 1.98 OK
THIRD FLOOR PLAN - Lift - Depth Mt. 1.90 2.14 OK
TERRACE FLOOR PLAN - Lift Machine Room - Width Mt. 1.70 1.98 OK
TERRACE FLOOR PLAN - Lift Machine Room - Depth Mt. 1.90 2.14 OK
THIRD FLOOR PLAN STAIRCASE - Flight Width Mt. 0.900 0.914 OK
STAIRCASE - Tread Width Mt. 0.250 0.254 OK
STAIRCASE - Riser Height Mt. 0.200 0.145 OK
STAIRCASE - Riser No. On Flight No. - 11 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
TERRACE FLOOR PLAN STAIRCASE - Flight Width Mt. - 0.914 OK
STAIRCASE - Tread Width Mt. - 0.254 OK
STAIRCASE - Riser Height Mt. - - OK
STAIRCASE - Riser No. On Flight No. - - OK
STAIRCASE - Cabin Ht. Mt. - - 2.591 OK
Sewage Treatment Plant Area Sq.Mt. - - 1.10 OK
Width Mt. - - 0.94 OK
Depth Mt. - - 1.17 OK
Height Mt. - - - OK
RAIN WATER HARVESTING Area Sq.Mt. - - 2.52 OK
Width Mt. - - 1.30 OK
Depth Mt. - - 1.95 OK
Height Mt. - - - OK
ENT.GATE Area Sq.Mt. - - 0.68 OK
Width Mt. - - 0.31 OK
Depth Mt. - - 2.19 OK
Height Mt. - - - OK
SOLAR HEATING SYSTEM Area Sq.Mt. - - 3.05 OK
Width Mt. - - 1.57 OK
Depth Mt. - - 1.95 OK
Height Mt. - - - OK
A (SMT MALAY DUTTA AND SMT TANUJA DATTA AND SMT DIPALI DUTTA) Rain Water Harvesting - No No. 1 - 1 OK
   
    All Rooms are as per Rule in Room Checking




[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Width No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Depth No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Access Width The minimum width of abutting road for any Building shall be with respect to Length of Road {As per Rule No. 34 Table No.6}
Plot Frontage No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
FAR Area (1) In Old Area, for Non-Residential Building on abutting roadwidth 7.5 (25 ft.) to 9.10 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15}
(2) For Lohardaga Nagar Parishad, Max. 2.0 permissible FAR may be permitted for Commercial or Mercantile type Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Non-Residential Building on abutting roadwidth 7.5 (25 ft.) to 9.10 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15}
(2) For Lohardaga Nagar Parishad, Max. 2.0 permissible FAR may be permitted for Commercial or Mercantile type Use {As per Annexure III}
Common Plot Area In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
Common Plot (1) In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
(2) ;
Tree Number 4-8 Trees shall be required for the Plot area above 250.0 and upto 1000.0 sq.mt. (As per Rule No. 20.1.6)
DriveWay Rule For Plor area upto 2000 sq.mt., the minimum width or driveways should not be less than 3.60 mt. {As per Rule No. 41.2 and modified as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
Margin Rule For Non-highrise Commercial Building upto 16.4 mt. Ht. having Plot Depth 15-21 mt. and Plot width 15-21 mt. or above, Margin required in Front shall be 5.5 mt., Rear 4.0 mt. and 2.5 mt. shall be provided on both side. {As per Rule No. 36 Table 10 & 11}
Building Level
Building Height For old area, on Road width 7.50-9.10 mt., Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 19.25 mt. {As per Rule No. 39.1 Table 15}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(3) The plinth or any part of a building shall be so located with respect to the surrounding ground level that adequate drainage of the site is assured. The height of the plinth (except in case of stilted parking) shall be not less than 0.45 mt. from the surrounding ground level {As per Rule No. 42.10}
Parapet Height (1) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
(2) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
(3) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
Floor Number For old area location,on Road width 7.5-9.1 mt. only G+5 floors shall be allowed {As per Rule No. 39.1 Table 15}
Lift Count (1) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(2) For Residential Building height upto 15.0 mt or upto G+4 floors, No Lift is reqd. {As per Amended 06-06-2019 Rule No. 49.1.1}
Lift (1) The area of lift well shall not be counted for F.A.R calculation)
(2) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(3) -
StairCase (1) Width of Winding staircase shall be mini. 0.90 mt.,Maximum rise 0.20 mt. & Minimum tread 0.25 mt. & Cabin Height 2.1 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) No Rule Defined
(4) ; No Rule Defined
Plot / Building Level
Accessory Use (1) -
(2) No need to check distance from Building Sewage Treatment Plant
(3) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(4) No need to check distance from Building RAIN WATER HARVESTING
(5) No need to check distance from Building ENT.GATE
(6) -
(7) No need to check distance from Building SOLAR HEATING SYSTEM
Accessory Use Number Provision of Rain Water Harvesting shall be mandatory for any use {Updated as per JBBL, Amendment VIII dated 16/03/2021} Rain Water Harvesting
Building Level (Rooms)