No Image Found

Check List Report

Lohardaga Nagar Parishad

Version Number: 1.0.37
Version Date: 29/04/2019
Report Generated On: 17-07-2019

[-] Collapse All


General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictLOHARDAGA
AuthorityLOHARDAGA NAGAR PARISHAD
Inward_NoLNP/BP/0026/W19/2019
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentNew
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillageLohardaga
Taluka26
Architect Details
Architect NameANUP KUMAR SINHA
License No.LNP/ARC/0001/2018
Architect Address3rd Floor, Roshpa Tower, Main Road, Ranchi
Architect EmailIDtheaksassociates@gmail.com
Architect Mobile No8986652248
Plot Details
Plot Use Residential
Plot SubUse MultiDwelling Units
PlotNearbyReligiousStructure NA
Plot/SubPlot No1882
NorthPlot No. - 1883
SouthPlot No. - 1887
EastRoad Width - 5.186
WestPlot No. - 1560
Owner's Details
NameLILAWATI DEVI
AddressC/O, LILAWATI DEVI ASHOK NAGAR, NEAR BANK OF BARODA, THAKURAIN TALAB, LOHARDAGA
Email IDsantosh1396@gmail.com
Mobile No9415052000
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 349.45
2 Plot area as per Document by Applicant 349.45
3 Physical area measured at site 349.45
4 Area as per Site Visit (Site Visit Report) 349.45
5Area as per Drawing 349.45

Area of Plot Considered : 349.45

Plot area provided in drawing shall not be more than Plot area as per Document.
[-] Table 2b
Proposal Detail :
UnitMeters
Development Detail :
PlotPLOT
Plot OccupancyResidential
Plot SubUse MultiDwelling Units
Building StructureNon-Highrise
Building TypeSingle Detached House
Gross Plot Area 349.45
Deduction from Gross Plot area
- Surrender Free of Cost 10.77
10.77
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 338.68
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 296.95
Deductions for Balance Plot Area (from Gross Plot Area)
- Surrender Free of Cost 10.77
- Common Plot 41.72
52.50
Balance Plot Area 296.95

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 60.00 % ) 203.21
Proposed Coverage Area ( 57.60 % ) 195.07
Total Prop. Coverage Area ( 57.6 % ) 195.07
Balance coverage area ( 2.40 % ) 8.14
FAR CHECK
Perm. FAR Area ( 1.50 ) 524.18
Total Perm. FAR area 524.18
Residential FAR 333.42
Proposed FAR Area 333.42
Total Proposed FAR Area 333.42
Consumed FAR (Factor) 0.95
Balance FAR Area 190.76
BUA CHECK
Total Proposed BuiltUp Area 389.80


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Exceeding 300 meter and upto 400 meter -
Existing Road Width 4.2 4.20
Proposed Road Width as per Master Plan 4.2 -
Road Widening Width 1.2 1.65
Plot size (as per measurement) 349.45 349.45
[-] Extra Land Area Checks
Name Area Status
Reqd Prop
Extra Land - 0.00 OK

Extra Land Area Details
Name Description Unit Reqd Perm Proposed Status
Extra Land Area Details Extra Land Area - - 0.00 OK

Plot Related Details
Name Description Unit Reqd Perm Proposed Status
PLOT Plot Area Sq.Mt. - - 338.68 OK
Plot Width Mt. - - 7.28 OK
Plot Depth Mt. - - 46.54 OK
Access Width Mt. - - 4.20 OK
Plot Frontage Mt. - - 6.53 OK
Coverage Area Sq.Mt. - 203.21 195.07 OK
FAR Area Sq.Mt. - 524.18 333.42 OK
Consumed FAR Sq.Mt. - 1.50 0.95 OK
Common Plot Checks Common Plot - Total Area Sq.Mt. 33.87 41.72 OK
Common Plot Normal Open Space - Minimum Area Sq.Mt. - 14.51 OK
Normal Open Space - Access Mt. - OK
Normal Open Space - Minimum Area Sq.Mt. - 27.21 OK
Normal Open Space - Access Mt. - OK
Tree Tree - Nos Of Trees No. 4 6 OK
A-1 (RESIDENTIAL BUILDING) Front Margin... ROAD WIDENING AREA(SURRENDERED FREE OF COST) Mt. 4.00 - 6.35 OK
Rear Margin Mt. 4.00 - 4.00 OK
Side1 Margin Mt. 1.00 - 1.00 OK
Side2 Margin Mt. 1.00 - 1.00 OK
A-1 (RESIDENTIAL BUILDING) BldgLine for 4.2 M WIDE ROAD Mt. 1.65 8.00 OK
A-1 (RESIDENTIAL BUILDING) ResvRoad Width Check for... 4.2 M WIDE ROAD Mt. 1.65 1.65 OK

Building Related Details
Name Description Unit Reqd Perm Proposed Status
A (RESIDENTIAL BUILDING) Height Mt. 10.00 6.60 OK
A (RESIDENTIAL BUILDING) First Floor - Height Mt. 2.75 - 3.30 OK
First Floor - Clear Height Mt. 2.75 - 3.20 OK
First Floor - Beam Clear Height Mt. 2.40 - 3.00 OK
Ground Floor - Height Mt. 2.75 - 3.30 OK
Ground Floor - Clear Height Mt. 2.75 - 3.20 OK
Ground Floor - Beam Clear Height Mt. 2.40 - 3.00 OK
Plinth - Height Mt. 0.45 - 0.45 OK
Plinth - Clear Height Mt. - - 0.45 OK
Plinth - Beam Clear Height Mt. - - 0.45 OK
A (RESIDENTIAL BUILDING) Terrace Floor - Height Mt. 1.00 1.20 1.00 OK
A (RESIDENTIAL BUILDING) No. of Floors No. G + 2 2 OK
No. of Tenements No. - 1 OK
GROUND FLOOR PLAN STAIRCASE - Flight Width Mt. 0.750 1.050 OK
STAIRCASE - Tread Width Mt. 0.225 0.250 OK
STAIRCASE - Riser Height Mt. 0.200 0.165 OK
STAIRCASE - Riser No. On Flight No. - 10 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
FIRST FLOOR PLAN STAIRCASE - Flight Width Mt. 0.750 1.050 OK
STAIRCASE - Tread Width Mt. 0.225 0.250 OK
STAIRCASE - Riser Height Mt. 0.200 0.165 OK
STAIRCASE - Riser No. On Flight No. - 10 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
RAIN WATER HARVESTING Area Sq.Mt. - - 0.92 OK
Width Mt. - - 0.48 OK
Depth Mt. - - 1.94 OK
Height Mt. - - - OK
ENT.GATE Area Sq.Mt. - - 0.52 OK
Width Mt. - - 0.18 OK
Depth Mt. - - 2.84 OK
Height Mt. - - - OK
Entrance Lobby Area Sq.Mt. - 12.00 7.85 OK
Width Mt. - - 2.36 OK
Depth Mt. - - 3.65 OK
Height Mt. - - - OK
Area Sq.Mt. - 12.00 7.85 OK
Width Mt. - - 2.36 OK
Depth Mt. - - 3.65 OK
Height Mt. - - - OK
SOLAR HEATING SYSTEM Area Sq.Mt. - - 5.63 OK
Width Mt. - - 2.13 OK
Depth Mt. - - 2.64 OK
Height Mt. - - - OK
A (RESIDENTIAL BUILDING) Rain Water Harvesting - No No. 1 - 1 OK
All Rooms are as per Rule in Room Checking




[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use
Plot Width No rule provided for Min. Plot size for proposed Use
Plot Depth No rule provided for Min. Plot size for proposed Use
Access Width The minimum width of abutting road for any Building shall be with respect to Length of Road {As per Rule No. 34 Table No.6}
Plot Frontage No rule provided for Min. Plot size for proposed Use
FAR Area (1) In Old Area, for Residential Building on abutting roadwidth 3.60 (12 ft.) to 4.80 mt., the Floor Area Ratio-FAR shall be 1.5 {As per Rule No.39, Table 15}
(2) For Lohardaga Nagar Parishad Max. 2.0 permissible FAR may be permitted for Residential Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Residential Building on abutting roadwidth 3.60 (12 ft.) to 4.80 mt., the Floor Area Ratio-FAR shall be 1.5 {As per Rule No.39, Table 15}
(2) For Lohardaga Nagar Parishad Max. 2.0 permissible FAR may be permitted for Residential Use {As per Annexure III}
Common Plot Area In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
Common Plot (1) ;
(2) ;
(3) ; ;
Tree Number 4-8 Trees shall be required for the Plot area above 250.0 and upto 1000.0 sq.mt. (As per Rule No. 20.1.6)
Margin Rule For narrow plots,the setbacks on sides may be compensated in front and rear setbacks so as to ensure that the overall aggregate setbacks are maintained in the site, subject to maintaining a minimum of side setback of 1m in case of buildings of height up to 10.0 mt.
Building Line Check The min. width of Road for length of Road Exceeding 300 mt. shall be 7.50 mt. {As per Rule No. 34 Table No. 6}
ResvRoad Width Check The min. width of Road for length of Road Exceeding 300 mt. shall be 7.50 mt. {As per Rule No. 34 Table No. 6}
Building Level
Building Height For old area, on Road width 3.6-4.8 mt., Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 10.0 mt. {As per Rule No. 39.1 Table 15}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(3) The plinth or any part of a building shall be so located with respect to the surrounding ground level that adequate drainage of the site is assured. The height of the plinth (except in case of stilted parking) shall be not less than 0.45 mt. from the surrounding ground level {As per Rule No. 42.10}
Parapet Height Parapet walls and handrails provided on the edges of roof terraces, balcony, verandah, etc shall not be less than 1.0 m and not more than 1.2 m in height from the finished floor level {As per Rule No. 42.5}
Floor Number For old area location,on Road width 3.6-4.8 mt. only G+2 floors shall be allowed {As per Rule No. 39.1 Table 15}
StairCase (1) Width of Winding staircase shall be mini. 0.75 mt.,Maximum rise 0.20 mt. & Minimum tread 0.225 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
Plot / Building Level
Accessory Use (1) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(2) No need to check distance from Building RAIN WATER HARVESTING
(3) No need to check distance from Building ENT.GATE
(4) Entrance Lobby of maximum size of 12 sq.m. shall be taken Free from FAR
(5) No need to check distance from Building Entrance Lobby
(6) -
(7) No need to check distance from Building SOLAR HEATING SYSTEM
Accessory Use Number Provision of rainwater harvesting shall be mandatory for 300 sqm. and above size of plots-The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area Rain Water Harvesting
Building Level (Rooms)