Name |
Description |
Unit |
Reqd |
Perm |
Proposed |
Status |
|
A (VISHAW VIJAY KUMAR AND ABHISHEK KUMAR AGARWAL) |
Height |
Mt. |
|
10.00
|
9.00
|
OK
|
|
A (VISHAW VIJAY KUMAR AND ABHISHEK KUMAR AGARWAL) |
Second Floor - Height |
Mt. |
2.75
|
-
|
3.00
|
OK
|
Second Floor - Clear Height |
Mt. |
2.75
|
-
|
2.90
|
OK
|
Second Floor - Beam Clear Height |
Mt. |
2.40
|
-
|
2.75
|
OK
|
First Floor - Height |
Mt. |
2.75
|
-
|
3.00
|
OK
|
First Floor - Clear Height |
Mt. |
2.75
|
-
|
2.90
|
OK
|
First Floor - Beam Clear Height |
Mt. |
2.40
|
-
|
2.75
|
OK
|
Ground Floor - Height |
Mt. |
2.75
|
-
|
3.00
|
OK
|
Ground Floor - Clear Height |
Mt. |
2.75
|
-
|
2.90
|
OK
|
Ground Floor - Beam Clear Height |
Mt. |
2.40
|
-
|
2.75
|
OK
|
Plinth - Height |
Mt. |
0.45
|
-
|
0.60
|
OK
|
Plinth - Clear Height |
Mt. |
-
|
-
|
0.60
|
OK
|
Plinth - Beam Clear Height |
Mt. |
-
|
-
|
0.60
|
OK
|
|
A (VISHAW VIJAY KUMAR AND ABHISHEK KUMAR AGARWAL) |
Terrace Floor - Height |
Mt. |
1.00
|
1.20
|
1.07
|
OK
|
|
A (VISHAW VIJAY KUMAR AND ABHISHEK KUMAR AGARWAL) |
No. of Floors |
No. |
|
G + 2
|
3
|
OK
|
No. of Tenements |
No. |
|
-
|
1
|
OK
|
|
A (VISHAW VIJAY KUMAR AND ABHISHEK KUMAR AGARWAL) |
Number Of Lift(s) |
No. |
-
|
|
1
|
OK
|
Number Of Strature Lift(s) |
No. |
-
|
|
-
|
OK
|
Capacity Of Lift(s) Passanger |
No. |
-
|
|
6
|
OK
|
|
A (VISHAW VIJAY KUMAR AND ABHISHEK KUMAR AGARWAL) |
GROUND FLOOR PLAN - Lift - Width |
Mt. |
1.70
|
|
1.76
|
OK
|
GROUND FLOOR PLAN - Lift - Depth |
Mt. |
1.90
|
|
1.93
|
OK
|
FIRST FLOOR PLAN - Lift - Width |
Mt. |
1.70
|
|
1.76
|
OK
|
FIRST FLOOR PLAN - Lift - Depth |
Mt. |
1.90
|
|
1.93
|
OK
|
SECOND FLOOR PLAN - Lift - Width |
Mt. |
1.70
|
|
1.76
|
OK
|
SECOND FLOOR PLAN - Lift - Depth |
Mt. |
1.90
|
|
1.93
|
OK
|
TERRACE FLOOR PLAN - Lift Machine Room - Width |
Mt. |
1.70
|
|
1.76
|
OK
|
TERRACE FLOOR PLAN - Lift Machine Room - Depth |
Mt. |
1.90
|
|
1.93
|
OK
|
|
GROUND FLOOR PLAN |
Staircase -3FL - Flight Width |
Mt. |
0.900
|
|
1.050
|
OK
|
Staircase -3FL - Tread Width |
Mt. |
0.250
|
|
0.250
|
OK
|
Staircase -3FL - Riser Height |
Mt. |
|
0.200
|
0.100
|
OK
|
Staircase -3FL - Riser No. On Flight |
No. |
|
-
|
3
|
OK
|
Staircase -3FL - Cabin Ht. |
Mt. |
-
|
-
|
-
|
OK
|
FIRST FLOOR PLAN |
Staircase -3FL - Flight Width |
Mt. |
0.900
|
|
1.050
|
OK
|
Staircase -3FL - Tread Width |
Mt. |
0.250
|
|
0.250
|
OK
|
Staircase -3FL - Riser Height |
Mt. |
|
0.200
|
0.100
|
OK
|
Staircase -3FL - Riser No. On Flight |
No. |
|
-
|
3
|
OK
|
Staircase -3FL - Cabin Ht. |
Mt. |
-
|
-
|
-
|
OK
|
SECOND FLOOR PLAN |
Staircase -3FL - Flight Width |
Mt. |
0.900
|
|
1.050
|
OK
|
Staircase -3FL - Tread Width |
Mt. |
0.250
|
|
0.250
|
OK
|
Staircase -3FL - Riser Height |
Mt. |
|
0.200
|
0.100
|
OK
|
Staircase -3FL - Riser No. On Flight |
No. |
|
-
|
3
|
OK
|
Staircase -3FL - Cabin Ht. |
Mt. |
-
|
-
|
-
|
OK
|
TERRACE FLOOR PLAN |
Staircase -3FL - Flight Width |
Mt. |
-
|
|
1.050
|
OK
|
Staircase -3FL - Tread Width |
Mt. |
-
|
|
0.250
|
OK
|
Staircase -3FL - Riser Height |
Mt. |
|
-
|
-
|
OK
|
Staircase -3FL - Riser No. On Flight |
No. |
|
-
|
-
|
OK
|
Staircase -3FL - Cabin Ht. |
Mt. |
-
|
-
|
2.550
|
OK
|
|
Sewage Treatment Plant |
Area |
Sq.Mt. |
-
|
-
|
0.91
|
OK
|
Width |
Mt. |
-
|
-
|
0.85
|
OK
|
Depth |
Mt. |
-
|
-
|
1.07
|
OK
|
Height |
Mt. |
-
|
-
|
-
|
OK
|
RAIN WATER HARVESTING |
Area |
Sq.Mt. |
-
|
-
|
1.03
|
OK
|
Width |
Mt. |
-
|
-
|
0.85
|
OK
|
Depth |
Mt. |
-
|
-
|
1.22
|
OK
|
Height |
Mt. |
-
|
-
|
-
|
OK
|
ENT.GATE |
Area |
Sq.Mt. |
-
|
-
|
1.10
|
OK
|
Width |
Mt. |
-
|
-
|
0.41
|
OK
|
Depth |
Mt. |
-
|
-
|
2.67
|
OK
|
Height |
Mt. |
-
|
-
|
-
|
OK
|
SOLAR HEATING SYSTEM |
Area |
Sq.Mt. |
-
|
-
|
0.95
|
OK
|
Width |
Mt. |
-
|
-
|
0.85
|
OK
|
Depth |
Mt. |
-
|
-
|
1.12
|
OK
|
Height |
Mt. |
-
|
-
|
-
|
OK
|
|
|
[-] Rules
Topic |
Rule |
Plot Level |
Plot Area |
No rule provided for Min. Plot size for proposed Use
|
Plot Width |
No rule provided for Min. Plot size for proposed Use
|
Plot Depth |
No rule provided for Min. Plot size for proposed Use
|
Access Width |
The minimum width of abutting road for any Building shall be with respect to Length of Road {As per Rule No. 34 Table No.6}
|
Plot Frontage |
No rule provided for Min. Plot size for proposed Use
|
FAR Area |
(1)
In Old Area, for Residential Building on abutting roadwidth 4.80 (16 ft.) to 6.10 mt., the Floor Area Ratio-FAR shall be 1.8 {As per Rule No.39, Table 15}
(2)
For Lohardaga Nagar Parishad Max. 2.0 permissible FAR may be permitted for Residential Use {As per Annexure III}
|
Consumed FAR |
(1)
In Old Area, for Residential Building on abutting roadwidth 4.80 (16 ft.) to 6.10 mt., the Floor Area Ratio-FAR shall be 1.8 {As per Rule No.39, Table 15}
(2)
For Lohardaga Nagar Parishad Max. 2.0 permissible FAR may be permitted for Residential Use {As per Annexure III}
|
Common Plot Area |
In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
|
Common Plot |
(1)
In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
(2)
;
|
Tree Number |
2-4 Trees shall be required for the Plot area upto 250.0 sq.mt. (As per Rule No. 20.1.6)
|
Margin Rule |
For narrow plots,the setbacks on sides may be compensated in front and rear setbacks so as to ensure that the overall aggregate setbacks are maintained in the site, subject to maintaining a minimum of side setback of 1m in case of buildings of height up to 10.0 mt.
|
Building Line Check |
The min. width of Road for length of Road Exceeding 300 mt. shall be 7.50 mt. {As per Rule No. 34 Table No. 6}
|
ResvRoad Width Check |
The min. width of Road for length of Road Exceeding 300 mt. shall be 7.50 mt. {As per Rule No. 34 Table No. 6}
|
Building Level |
Building Height |
For old area, on Road width 4.8-6.10 mt., Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 10.0 mt. {As per Rule No. 39.1 Table 15}
|
Floor Height |
(1)
The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2)
The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(3)
The plinth or any part of a building shall be so located with respect to the surrounding ground level that adequate drainage of the site is assured. The height of the plinth (except in case of stilted parking) shall be not less than 0.45 mt. from the surrounding ground level {As per Rule No. 42.10}
|
Parapet Height |
Parapet walls and handrails provided on the edges of roof terraces, balcony, verandah, etc shall not be less than 1.0 m and not more than 1.2 m in height from the finished floor level {As per Rule No. 42.5}
|
Floor Number |
For old area location,on Road width 4.8-6.1 mt. only G+2 floors shall be allowed {As per Rule No. 39.1 Table 15}
|
Lift Count |
(1)
The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(2)
For Residential Building height upto 15.0 mt or upto G+4 floors, No Lift is reqd. {As per Amended 06-06-2019 Rule No. 49.1.1}
|
Lift |
(1)
The area of lift well at one floor only (not the sum of total area of lift well at every floor) shall be counted for F.A.R calculation)
(2)
The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(3)
The area of lift well shall not be counted for F.A.R calculation)
(4)
The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(5)
-
|
StairCase |
(1)
Width of Winding staircase shall be mini. 0.90 mt.,Maximum rise 0.20 mt. & Minimum tread 0.25 mt. & Cabin Height 2.1 mt. {As per Rule No. 83.18}
(2)
; No Rule Defined
(3)
No Rule Defined
(4)
; No Rule Defined
|
Plot / Building Level |
Accessory Use |
(1)
-
(2)
No need to check distance from Building Sewage Treatment Plant
(3)
The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(4)
No need to check distance from Building RAIN WATER HARVESTING
(5)
No need to check distance from Building ENT.GATE
(6)
-
(7)
No need to check distance from Building SOLAR HEATING SYSTEM
|
Building Level (Rooms) |
|