General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictLOHARDAGA
AuthorityLOHARDAGA NAGAR PARISHAD
Inward_NoLNP/BP/0019/W05/2020
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentNew
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillageKatmu
Taluka26
Architect Details
Architect NameASHWINI KUMAR SAHU
License No.LNP/ENG/0005/2017
Architect AddressNear check post, PWD Road
Architect EmailIDerashwinisahu@gmail.com
Architect Mobile No9308730823
Plot Details
Plot Use Mixed
Plot SubUse Resi+Comm
PlotNearbyReligiousStructure NA
Plot/SubPlot No1128/869
NorthPlot No. - 869
SouthRoad Width - 10.2
EastRoad Width - 4.57
WestPlot No. - 866
Owner's Details
NameSAHITA SAHU
AddressNEAR RAILWAY CROSSING , KISKO MORE
Email IDSOALOHARDAGA@GMAIL.COM
Mobile No7978670701
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 901.57
2 Plot area as per Document by Applicant 405.90
3 Physical area measured at site 405.90
4 Area as per Site Visit (Site Visit Report) 405.90
5Area as per Drawing 405.90

Area of Plot Considered : 405.90

[-] Table 2b
Proposal Detail :
UnitMeters
Development Detail :
PlotPLOT
Plot OccupancyMixed
Plot SubUse -
Higher Plot Use
Higher Plot Sub UseResi+Comm
Lower Plot Use
Lower Plot Sub Use
Building StructureNon-Highrise
Building TypeSingle Detached House
Gross Plot Area 405.90
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 405.90
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 354.84
Deductions for Balance Plot Area (from Gross Plot Area)
- Common Plot 51.06
51.06
Balance Plot Area 354.84

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 60.00 % ) 243.54
Proposed Coverage Area ( 34.49 % ) 139.98
Total Prop. Coverage Area ( 34.49 % ) 139.98
Balance coverage area ( 25.51 % ) 103.56
FAR CHECK
Perm. FAR Area ( 2.00 ) 811.80
Total Perm. FAR area 811.80
Residential FAR 79.95
Commercial FAR 404.93
Proposed FAR Area 484.88
Total Proposed FAR Area 484.88
Consumed FAR (Factor) 1.19
Balance FAR Area 326.92
BUA CHECK
Total Proposed BuiltUp Area 558.15


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Exceeding 1000 meter -
Existing Road Width 10.2 10.20
Proposed Road Width as per Master Plan 10.2 -
Road Widening Width 0 -
Plot size (as per measurement) 405.9 405.90
[-] Extra Land Area Checks
Name Area Status
Reqd Prop
Extra Land - 0.00 OK

     Extra Land Area Details
Name Description Unit Reqd Perm Proposed Status
Extra Land Area Details Extra Land Area - - 0.00 OK

     Plot Related Details
Name Description Unit Reqd Perm Proposed Status
PLOT Plot Area Sq.Mt. - - 405.90 OK
Plot Width Mt. - - 16.50 OK
Plot Depth Mt. - - 24.60 OK
Access Width Mt. - - 10.20 OK
Plot Frontage Mt. - - 16.50 OK
Coverage Area Sq.Mt. - 243.54 139.98 OK
FAR Area Sq.Mt. - 811.80 484.88 OK
Consumed FAR Sq.Mt. - 2.00 1.19 OK
Common Plot Checks Common Plot - Total Area Sq.Mt. 40.59 51.06 OK
Common Plot Tree Cover (Plantation) - Minimum Area Sq.Mt. - 51.06 OK
Tree Cover (Plantation) - Coverage Area Sq.Mt. - - OK
Tree Cover (Plantation) - Width Mt. - 3.72 OK
Tree Cover (Plantation) - Angle Degree - 90.00 OK
Tree Cover (Plantation) - Access Mt. - OK
Tree Tree - Nos Of Trees No. 4 15 OK
Car In Area Sq.Mt. - - 50.00 OK
Two Stack.Car In Area Sq.Mt. - - 50.00 OK
Total Car In Area Sq.Mt. 37.50 - 100.00 OK
Total Visitor Parking In Area Sq.Mt. 37.50 - 40.50 OK
Parallel Visitor's Car Parking In Area Sq.Mt. - - 40.50 OK
TwoWheeler In Area Sq.Mt. - - 20.00 OK
Total TwoWheeler In Area Sq.Mt. 4.00 - 20.00 OK
Other Parking In Area Sq.Mt. - - 63.10 OK
A-1 (SMT SAHITA SAHU) Front Margin... 10.20 MTR. WIDE ROAD Access Road Mt. 3.00 - 6.96 OK
Rear Margin Mt. 2.25 - 5.07 OK
Side1 Margin Mt. 1.50 - 2.55 OK
Side2 Margin Mt. 1.50 - 2.82 OK

     Building Related Details
Name Description Unit Reqd Perm Proposed Status
A (SMT SAHITA SAHU) Height Mt. 22.26 12.40 OK
A (SMT SAHITA SAHU) Third Floor - Height Mt. 2.75 - 3.10 OK
Third Floor - Clear Height Mt. 2.75 - 3.00 OK
Third Floor - Beam Clear Height Mt. 2.40 - 2.85 OK
Second Floor - Height Mt. 2.75 - 3.10 OK
Second Floor - Clear Height Mt. 2.75 - 3.00 OK
Second Floor - Beam Clear Height Mt. 2.40 - 2.85 OK
First Floor - Height Mt. 2.75 - 3.10 OK
First Floor - Clear Height Mt. 2.75 - 3.00 OK
First Floor - Beam Clear Height Mt. 2.40 - 2.85 OK
Ground Floor - Height Mt. 2.75 - 3.10 OK
Ground Floor - Clear Height Mt. 2.75 - 3.00 OK
Ground Floor - Beam Clear Height Mt. 2.40 - 2.85 OK
Plinth - Height Mt. 0.45 - 0.60 OK
Plinth - Clear Height Mt. - - 0.60 OK
Plinth - Beam Clear Height Mt. - - 0.60 OK
A (SMT SAHITA SAHU) Terrace Floor - Height Mt. 1.00 1.20 1.07 OK
A (SMT SAHITA SAHU) No. of Floors No. G + 6 4 OK
No. of Tenements No. - 6 OK
A (SMT SAHITA SAHU) Number Of Lift(s) No. - 1 OK
Number Of Strature Lift(s) No. - - OK
Capacity Of Lift(s) Passanger No. - 6 OK
A (SMT SAHITA SAHU) GROUND FLOOR PLAN - Lift - Width Mt. 1.70 1.75 OK
GROUND FLOOR PLAN - Lift - Depth Mt. 1.90 1.94 OK
FIRST FLOOR PLAN - Lift - Width Mt. 1.70 1.75 OK
FIRST FLOOR PLAN - Lift - Depth Mt. 1.90 1.94 OK
SECOND FLOOR PLAN - Lift - Width Mt. 1.70 1.75 OK
SECOND FLOOR PLAN - Lift - Depth Mt. 1.90 1.94 OK
THIRD FLOOR PLAN - Lift - Width Mt. 1.70 1.75 OK
THIRD FLOOR PLAN - Lift - Depth Mt. 1.90 1.94 OK
TERRACE FLOOR PLAN - Lift Machine Room - Width Mt. 1.70 1.75 OK
TERRACE FLOOR PLAN - Lift Machine Room - Depth Mt. 1.90 1.94 OK
GROUND FLOOR PLAN STAIRCASE - Flight Width Mt. 0.900 1.050 OK
STAIRCASE - Tread Width Mt. 0.250 0.250 OK
STAIRCASE - Riser Height Mt. 0.200 0.141 OK
STAIRCASE - Riser No. On Flight No. - 11 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
FIRST FLOOR PLAN STAIRCASE - Flight Width Mt. 0.900 0.900 OK
STAIRCASE - Tread Width Mt. 0.250 0.250 OK
STAIRCASE - Riser Height Mt. 0.200 0.155 OK
STAIRCASE - Riser No. On Flight No. - 7 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
STAIRCASE - Flight Width Mt. 0.900 1.050 OK
STAIRCASE - Tread Width Mt. 0.250 0.250 OK
STAIRCASE - Riser Height Mt. 0.200 0.141 OK
STAIRCASE - Riser No. On Flight No. - 11 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
SECOND FLOOR PLAN STAIRCASE - Flight Width Mt. 0.900 1.050 OK
STAIRCASE - Tread Width Mt. 0.250 0.250 OK
STAIRCASE - Riser Height Mt. 0.200 0.141 OK
STAIRCASE - Riser No. On Flight No. - 11 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
THIRD FLOOR PLAN STAIRCASE - Flight Width Mt. 0.900 1.050 OK
STAIRCASE - Tread Width Mt. 0.250 0.250 OK
STAIRCASE - Riser Height Mt. 0.200 0.141 OK
STAIRCASE - Riser No. On Flight No. - 11 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
TERRACE FLOOR PLAN STAIRCASE - Flight Width Mt. - 1.050 OK
STAIRCASE - Tread Width Mt. - 0.250 OK
STAIRCASE - Riser Height Mt. - - OK
STAIRCASE - Riser No. On Flight No. - - OK
STAIRCASE - Cabin Ht. Mt. - - 2.550 OK
Toilet Area Sq.Mt. - 5.00 4.10 OK
Width Mt. - - 1.67 OK
Depth Mt. - - 2.46 OK
Height Mt. - - - OK
Sewage Treatment Plant Area Sq.Mt. - - 0.99 OK
Width Mt. - - 0.92 OK
Depth Mt. - - 1.07 OK
Height Mt. - - - OK
RAIN WATER HARVESTING Area Sq.Mt. - - 2.08 OK
Width Mt. - - 1.22 OK
Depth Mt. - - 1.71 OK
Height Mt. - - - OK
ENT.GATE Area Sq.Mt. - - 1.10 OK
Width Mt. - - 0.41 OK
Depth Mt. - - 2.67 OK
Height Mt. - - - OK
Area Sq.Mt. - - 1.49 OK
Width Mt. - - 0.53 OK
Depth Mt. - - 2.81 OK
Height Mt. - - - OK
SOLAR HEATING SYSTEM Area Sq.Mt. - - 1.88 OK
Width Mt. - - 1.12 OK
Depth Mt. - - 1.68 OK
Height Mt. - - - OK
A (SMT SAHITA SAHU) Rain Water Harvesting - No No. 1 - 1 OK
   
    All Rooms are as per Rule in Room Checking




[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use
Plot Width No rule provided for Min. Plot size for proposed Use
Plot Depth No rule provided for Min. Plot size for proposed Use
Access Width The minimum width of abutting road for any Building shall be with respect to Length of Road {As per Rule No. 34 Table No.6}
Plot Frontage No rule provided for Min. Plot size for proposed Use
FAR Area (1) In Old Area, for Non-Residential Building on abutting roadwidth 9.10 (30 ft.) to 12.20 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15}
(2) For Lohardaga Nagar Parishad, Max. 2.0 permissible FAR may be permitted for Commercial or Mercantile type Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Non-Residential Building on abutting roadwidth 9.10 (30 ft.) to 12.20 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15}
(2) For Lohardaga Nagar Parishad, Max. 2.0 permissible FAR may be permitted for Commercial or Mercantile type Use {As per Annexure III}
Common Plot Area In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
Common Plot (1) In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
(2) ;
Tree Number 4-8 Trees shall be required for the Plot area above 250.0 and upto 1000.0 sq.mt. (As per Rule No. 20.1.6)
Margin Rule For Non-highrise Residential Building 10-13.3 mt. Ht. having Plot Depth 21-27 mt. and Plot width 15-21 mt., Margin required in Front shall be 3.0 mt., Rear 2.25 mt. and 1.5 mt. shall be provided on both side. {As per Rule No. 36 (Table 8 & 9 and updated as per 4th Amendment dated 2nd Jan, 2019}
Building Level
Building Height For old area, on Road width 9.10-12.20 mt., Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 23.10 mt. {As per Rule No. 39.1 Table 15}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(3) The plinth or any part of a building shall be so located with respect to the surrounding ground level that adequate drainage of the site is assured. The height of the plinth (except in case of stilted parking) shall be not less than 0.45 mt. from the surrounding ground level {As per Rule No. 42.10}
Parapet Height Parapet walls and handrails provided on the edges of roof terraces, balcony, verandah, etc shall not be less than 1.0 m and not more than 1.2 m in height from the finished floor level {As per Rule No. 42.5}
Floor Number For old area location,on Road width 9.1-12.20 mt. only G+6 floors shall be allowed {As per Rule No. 39.1 Table 15}
Lift Count (1) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(2) For Residential Building height upto 15.0 mt or upto G+4 floors, No Lift is reqd. {As per Amended 06-06-2019 Rule No. 49.1.1}
Lift (1) The area of lift well at one floor only (not the sum of total area of lift well at every floor) shall be counted for F.A.R calculation)
(2) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(3) The area of lift well shall not be counted for F.A.R calculation)
(4) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(5) -
StairCase (1) Width of Winding staircase shall be mini. 0.90 mt.,Maximum rise 0.20 mt. & Minimum tread 0.25 mt. & Cabin Height 2.1 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) No Rule Defined
(4) ; No Rule Defined
Plot / Building Level
Accessory Use (1) Common toilet of maximum size of 5 sq.mt shall be taken Free from FAR
(2) No need to check distance from Building Toilet
(3) -
(4) No need to check distance from Building Sewage Treatment Plant
(5) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(6) No need to check distance from Building RAIN WATER HARVESTING
(7) No need to check distance from Building ENT.GATE
(8) -
(9) No need to check distance from Building SOLAR HEATING SYSTEM
Accessory Use Number Provision of rainwater harvesting shall be mandatory for 300 sqm. and above size of plots-The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area Rain Water Harvesting
Building Level (Rooms)