-
No Image Found   

Check List Report

Lohardaga Nagar Parishad

Version Number: 1.0.49  
Version Date: 22/06/2020 
Report Generated On: 08-10-2020 
 

[-] Collapse All


General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictLOHARDAGA
AuthorityLOHARDAGA NAGAR PARISHAD
Inward_NoLNP/BP/0029/W14/2020
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentNew
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillageLohardaga
Taluka26
Architect Details
Architect NameASHWINI KUMAR SAHU
License No.LNP/ENG/0005/2017
Architect AddressNear check post, PWD Road
Architect EmailIDerashwinisahu@gmail.com
Architect Mobile No9308730823
Plot Details
Plot Use Residential
Plot SubUse Bungalow/ Dwelling / Non Apartment
PlotNearbyReligiousStructure NA
Plot/SubPlot No581,579
NorthPlot No. - 577,580
SouthRoad Width - 3
EastRoad Width - 3
WestPlot No. - 578
Owner's Details
NameAMIYA KERKETTA
AddressSARNA TOLI LOHARDAGA
Email IDSOALOHARDAGA@GMAIL.COM
Mobile No9430187837
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Plot area as per Document by Applicant 465.86
2 Physical area measured at site 465.86
3 Area as per Site Visit (Site Visit Report) 465.86
4Area as per Drawing 465.69

Area of Plot Considered : 465.69

[-] Table 2b
Proposal Detail :
UnitMeters
Development Detail :
PlotPLOT
Plot OccupancyResidential
Plot SubUse Bungalow/ Dwelling / Non Apartment
Building StructureNon-Highrise
Building TypeSingle Detached House
Gross Plot Area 465.69
Deduction from Gross Plot area
- Surrender Free of Cost 39.71
39.71
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 425.98
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 380.98
Deductions for Balance Plot Area (from Gross Plot Area)
- Surrender Free of Cost 39.71
- Common Plot 44.99
84.71
Balance Plot Area 380.98

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 60.00 % ) 255.59
Proposed Coverage Area ( 24.74 % ) 105.38
Total Prop. Coverage Area ( 24.74 % ) 105.38
Balance coverage area ( 35.26 % ) 150.21
FAR CHECK
Perm. FAR Area ( 1.20 ) 558.83
Total Perm. FAR area 558.83
Residential FAR 192.11
Proposed FAR Area 192.11
Total Proposed FAR Area 192.11
Consumed FAR (Factor) 0.41
Balance FAR Area 366.72
BUA CHECK
Total Proposed BuiltUp Area 210.76


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Exceeding 100 meter and upto 250 meter -
Existing Road Width 3 3.00
Proposed Road Width as per Master Plan 3 -
Road Widening Width 0 1.60
Plot size (as per measurement) 465.86 465.69

     Plot Related Details
Name Description Unit Reqd Perm Proposed Status
PLOT Plot Area Sq.Mt. - - 425.98 OK
Plot Width Mt. - - 27.69 OK
Plot Depth Mt. - - 15.39 OK
Access Width Mt. - - 3.00 OK
Plot Frontage Mt. - - 24.89 OK
Coverage Area Sq.Mt. - 255.59 105.38 OK
FAR Area Sq.Mt. - 558.83 192.11 OK
Consumed FAR Sq.Mt. - 1.20 0.41 OK
Common Plot Checks Common Plot - Total Area Sq.Mt. 21.30 44.99 OK
Common Plot Tree Cover (Plantation) - Minimum Area Sq.Mt. - 44.99 OK
Tree Cover (Plantation) - Coverage Area Sq.Mt. - - OK
Tree Cover (Plantation) - Width Mt. - 3.39 OK
Tree Cover (Plantation) - Angle Degree - 75.79 OK
Tree Cover (Plantation) - Access Mt. - OK
Tree Tree - Nos Of Trees No. 4 9 OK
A-1 (AMIYA KERKETTA) Front Margin... ROAD WIDENING AREA(SURRENDERED FREE OF COST) Mt. 2.50 - 2.53 OK
Rear Margin Mt. 1.50 - 1.50 OK
Side1 Margin Mt. 1.50 - 2.43 OK
Side2 Margin Mt. 1.50 - 13.85 OK
A-1 (AMIYA KERKETTA) BldgLine for 3.0 MTR WIDE ROAD Access Road Mt. 1.55 4.11 OK
A-1 (AMIYA KERKETTA) ResvRoad Width Check for... 3.0 MTR WIDE ROAD Access Road Mt. 1.55 1.58 OK

     Building Related Details
Name Description Unit Reqd Perm Proposed Status
A (AMIYA KERKETTA) First Floor - Height Mt. 2.75 - 3.00 OK
First Floor - Clear Height Mt. 2.75 - 2.90 OK
First Floor - Beam Clear Height Mt. 2.40 - 2.77 OK
Ground Floor - Height Mt. 2.75 - 3.00 OK
Ground Floor - Clear Height Mt. 2.75 - 2.90 OK
Ground Floor - Beam Clear Height Mt. 2.40 - 2.77 OK
Plinth - Height Mt. 0.45 - 0.60 OK
Plinth - Clear Height Mt. - - 0.60 OK
Plinth - Beam Clear Height Mt. - - 0.60 OK
A (AMIYA KERKETTA) Terrace Floor - Height Mt. 1.00 1.20 1.03 OK
A (AMIYA KERKETTA) No. of Floors No. G + 1 2 OK
No. of Tenements No. - 1 OK
GROUND FLOOR PLAN STAIRCASE - Flight Width Mt. 0.750 0.900 OK
STAIRCASE - Tread Width Mt. 0.225 0.250 OK
STAIRCASE - Riser Height Mt. 0.200 0.143 OK
STAIRCASE - Riser No. On Flight No. - 8 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
FIRST FLOOR PLAN STAIRCASE - Flight Width Mt. 0.750 0.900 OK
STAIRCASE - Tread Width Mt. 0.225 0.250 OK
STAIRCASE - Riser Height Mt. 0.200 0.143 OK
STAIRCASE - Riser No. On Flight No. - 8 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
TERRACE FLOOR PLAN STAIRCASE - Flight Width Mt. - 0.900 OK
STAIRCASE - Tread Width Mt. - 0.250 OK
STAIRCASE - Riser Height Mt. - - OK
STAIRCASE - Riser No. On Flight No. - - OK
STAIRCASE - Cabin Ht. Mt. 2.100 - 2.500 OK
Sewage Treatment Plant Area Sq.Mt. - - 0.91 OK
Width Mt. - - 0.76 OK
Depth Mt. - - 1.19 OK
Height Mt. - - - OK
RAIN WATER HARVESTING Area Sq.Mt. - - 1.76 OK
Width Mt. - - 1.20 OK
Depth Mt. - - 1.47 OK
Height Mt. - - - OK
ENT.GATE Area Sq.Mt. - - 1.60 OK
Width Mt. - - 0.62 OK
Depth Mt. - - 2.59 OK
Height Mt. - - - OK
Entrance Lobby Area Sq.Mt. - 12.00 4.05 OK
Width Mt. - - 1.80 OK
Depth Mt. - - 2.25 OK
Height Mt. - - - OK
Area Sq.Mt. - 12.00 4.28 OK
Width Mt. - - 1.90 OK
Depth Mt. - - 2.25 OK
Height Mt. - - - OK
Area Sq.Mt. - 12.00 1.00 OK
Width Mt. - - 0.44 OK
Depth Mt. - - 2.25 OK
Height Mt. - - - OK
Area Sq.Mt. - 12.00 4.05 OK
Width Mt. - - 1.80 OK
Depth Mt. - - 2.25 OK
Height Mt. - - - OK
Area Sq.Mt. - 12.00 4.28 OK
Width Mt. - - 1.90 OK
Depth Mt. - - 2.25 OK
Height Mt. - - - OK
Area Sq.Mt. - 12.00 1.00 OK
Width Mt. - - 0.44 OK
Depth Mt. - - 2.25 OK
Height Mt. - - - OK
SOLAR HEATING SYSTEM Area Sq.Mt. - - 1.76 OK
Width Mt. - - 1.20 OK
Depth Mt. - - 1.47 OK
Height Mt. - - - OK
A (AMIYA KERKETTA) Rain Water Harvesting - No No. 1 - 1 OK
   
    All Rooms are as per Rule in Room Checking




[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use
Plot Width No rule provided for Min. Plot size for proposed Use
Plot Depth No rule provided for Min. Plot size for proposed Use
Access Width The minimum width of abutting road for any Building shall be with respect to Length of Road {As per Rule No. 34 Table No.6}
Plot Frontage No rule provided for Min. Plot size for proposed Use
FAR Area (1) In Old Area, for Residential Building on abutting roadwidth less than 3.60 mt., the Floor Area Ratio-FAR shall be 1.2 {As per Rule No.39, Table 15, Note i}
(2) For Lohardaga Nagar Parishad Max. 2.0 permissible FAR may be permitted for Residential Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Residential Building on abutting roadwidth less than 3.60 mt., the Floor Area Ratio-FAR shall be 1.2 {As per Rule No.39, Table 15, Note i}
(2) For Lohardaga Nagar Parishad Max. 2.0 permissible FAR may be permitted for Residential Use {As per Annexure III}
Common Plot Area In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
Common Plot (1) In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
(2) ;
Tree Number 4-8 Trees shall be required for the Plot area above 250.0 and upto 1000.0 sq.mt. (As per Rule No. 20.1.6)
Margin Rule For Non-highrise Residential Building upto 10.0 mt. Ht. having Plot Depth 15-21 mt. and Plot width 27-33 mt., Margin required in Front shall be 2.5 mt., Rear 1.5 mt. and 1.5 mt. shall be provided on both side. {As per Rule No. 36 (Table 8 & 9)}
Building Line Check The min. width of Road for length of Road Exceeding 100 mt. and upto 300 mt. shall be 6.1 mt. {As per Rule No. 34 Table No. 6 and as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
ResvRoad Width Check The min. width of Road for length of Road Exceeding 100 mt. and upto 300 mt. shall be 6.1 mt. {As per Rule No. 34 Table No. 6 and as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
Building Level
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(3) The plinth or any part of a building shall be so located with respect to the surrounding ground level that adequate drainage of the site is assured. The height of the plinth (except in case of stilted parking) shall be not less than 0.45 mt. from the surrounding ground level {As per Rule No. 42.10}
Parapet Height Parapet walls and handrails provided on the edges of roof terraces, balcony, verandah, etc shall not be less than 1.0 m and not more than 1.2 m in height from the finished floor level {As per Rule No. 42.5}
Floor Number For old area location,on Road width upto 3.6 mt. only G+1 floors shall be allowed {As per Rule No. 39.1 Note 1}
StairCase (1) Width of Winding staircase shall be mini. 0.75 mt.,Maximum rise 0.20 mt. & Minimum tread 0.225 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) Width of Winding staircase shall be mini. 0.75 mt.,Maximum rise 0.20 mt. & Minimum tread 0.225 mt. & Cabin height 2.1 mt {As per Rule No. 83.18}
(4) ; No Rule Defined
Plot / Building Level
Accessory Use (1) -
(2) No need to check distance from Building Sewage Treatment Plant
(3) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(4) No need to check distance from Building RAIN WATER HARVESTING
(5) No need to check distance from Building ENT.GATE
(6) Entrance Lobby of maximum size of 12 sq.m. shall be taken Free from FAR
(7) No need to check distance from Building Entrance Lobby
(8) -
(9) No need to check distance from Building SOLAR HEATING SYSTEM
Accessory Use Number Provision of rainwater harvesting shall be mandatory for 300 sqm. and above size of plots-The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area Rain Water Harvesting
Building Level (Rooms)