No Image Found   

Detail Scrutiny Report

Lohardaga Nagar Parishad

Version Number: 1.0.44  
Version Date: 29/04/2019 
Report Generated On: 04-06-2020 
 
[-] Collapse All


General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictLOHARDAGA
AuthorityLOHARDAGA NAGAR PARISHAD
Inward_NoLNP/BP/0009/W22/2020
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentNew
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillageLohardaga
Taluka26
Architect Details
Architect NameSUNIL KUMAR
License No.LNP/ENG/0004/2017
Architect AddressBARWATOLI
Architect EmailIDsunil7527@gmail.com
Architect Mobile No7292899641
Plot Details
Plot Use Residential
Plot SubUse Bungalow/ Dwelling / Non Apartment
PlotNearbyReligiousStructure NA
Plot/SubPlot No796
NorthRoad Width - 5.40 MTR WIDE ROAD
SouthPlot No. - PLOT NO- 795
EastPlot No. - PLOT NO- 796
WestPlot No. - PLOT NO- 796
Owner's Details
NameSMT REKHA DEVI
AddressSUBRAN TOLI, LOHARDAG
Email IDsunil7527@gmail.com
Mobile No9097161889
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 230.95
2 Plot area as per Document by Applicant 230.95
3 Physical area measured at site 230.95
4 Area as per Site Visit (Site Visit Report) 230.95
5Area as per Drawing 230.95

Area of Plot Considered : 230.95

[-] Table 2b
Proposal Detail :
UnitMeters
Development Detail :
PlotPLOT
Plot OccupancyResidential
Plot SubUse Bungalow/ Dwelling / Non Apartment
Building StructureNon-Highrise
Building TypeSingle
Gross Plot Area 230.95
Deduction from Gross Plot area
- Surrender Free of Cost 28.60
28.60
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 202.35
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 172.51
Deductions for Balance Plot Area (from Gross Plot Area)
- Surrender Free of Cost 28.60
- Common Plot 29.83
58.43
Balance Plot Area 172.51

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 70.00 % ) 141.65
Proposed Coverage Area ( 50.56 % ) 102.31
Total Prop. Coverage Area ( 50.56 % ) 102.31
Balance coverage area ( 19.44 % ) 39.34
FAR CHECK
Perm. FAR Area ( 1.80 ) 415.71
Total Perm. FAR area 415.71
Residential FAR 204.62
Proposed FAR Area 204.62
Total Proposed FAR Area 204.62
Consumed FAR (Factor) 0.89
Balance FAR Area 211.09
BUA CHECK
Total Proposed BuiltUp Area 204.62


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Exceeding 250 meter and upto 300 meter -
Existing Road Width 5.4 5.40
Proposed Road Width as per Master Plan 5.4 -
Road Widening Width 0 2.00
Plot size (as per measurement) 230.95 230.95
[-] Extra Land Area Checks
Name Area Status
Reqd Prop
Extra Land - 0.00 OK


[-] Plot Level Checking (Table 3)
   
[-] Common Plot Checks (Table 3b)
Name Total Area Status
Reqd Prop
Common Plot 10.12 29.83 OK


[-] Common Plot Checks (Table 3b)
Name Minimum Area Coverage Area Width Angle Access Status
Reqd Prop Perm Prop Reqd Prop Reqd Prop
Tree Cover (Plantation) - 29.83 0.00 0.00 - 2.45 - 90.00 No Access Provided OK


   
   
[-] Tree Details (Table 3g)
Name Nos Of Trees Status
Reqd Prop
Tree 2 11 OK
   
   
   
   
   


[-] Building Details (Table 4)
   
[-] Building USE/SUBUSE Details Building USE/SUBUSE Details
Building Name Building Use Building SubUse Building Structure
A (SMT REKHA DEVI) Residential Bungalow/ Non-Highrise
   
   
   
[-] Height Details (4a)



[-] Total Height (Table 4a-1)
Building Height Height (From GL) Height (From Street LVL) Status
Perm Prop
A (SMT REKHA DEVI) - 6.00 6.00 6.00 OK


   
   
[-] Floor Height Check (Table 4a-2)
Building Name Floor Name Height Clear Height Beam Clear Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
A (SMT REKHA DEVI) First Floor 2.60 - 3.00 2.60 - 2.90 2.40 - 2.78 OK
Ground Floor 2.60 - 3.00 2.60 - 2.90 2.40 - 2.78 OK
Plinth 0.45 - 0.60 - - 0.60 - - 0.60 OK


[-] Parapet Height Check (Table 4a-2.1)
Building Name Floor Name Height Status
Reqd Perm Prop
A (SMT REKHA DEVI) Terrace Floor 1.00 1.20 1.07 OK
   
   
   
[-] Floor Number Check (Table 4a-4)
Building Name No. of Floors No. of Tenements Status
Perm Prop Perm Prop
A (SMT REKHA DEVI) - 2 - 1 OK

 
   
    [-] Coverage Check (Table 4b)
Permissible Proposed Status
141.65 102.31 OK
70% 50.56%

[-] Individual Coverage Check
Coverage Area Perm. Prop.
  A-1 (SMT REKHA DEVI) - 102.31
  Total Prop. Coverage Area - 102.31
  Total Coverage Area 141.65 102.31

[-] FAR & Tenement Details (Table 4c-1)
Building No. of Same Bldg Total Built Up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
Resi.
A (SMT REKHA DEVI) 1 204.62 204.62 204.62 204.62 01
Grand Total : 1 204.62 204.62 204.62 204.62 01


[-] Buildingwise Floor FAR Details
Floor Name Building Name Total
A (SMT REKHA DEVI)
Proposed Built Up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Total Proposed Built Up Area (Sq.mt.) Total FAR Area (Sq.mt.)
Ground Floor 102.31 102.31 102.31 102.31
First Floor 102.31 102.31 102.31 102.31
Terrace Floor 0.00 0.00 0.00 0.00
Total : 204.62 204.62 204.62 204.62


[-] UnitBUA Table for Building :A (SMT REKHA DEVI)
UnitBUA CALCULATION
FLOOR Name UnitBUA Type UnitBUA Area Carpet Area No. of Rooms No. of Tenement
GROUND FLOOR PLAN SPLIT A FLAT 166.44 166.23 9 1
FIRST FLOOR PLAN SPLIT A FLAT 0.00 0.00 9 0
Total: - - 166.44 166.23 18 1


[-] Building :A (SMT REKHA DEVI)
Floor Name Total Built Up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
Resi.
Ground Floor 102.31 102.31 102.31 102.31 01
First Floor 102.31 102.31 102.31 102.31 00
Terrace Floor 0.00 0.00 0.00 0.00 00
Total : 204.62 204.62 204.62 204.62 01
Total Number of Same Buildings : 1
Total : 204.62 204.62 204.62 204.62 01
[-] Table 4c-2

  FAR Area
Building FAR Area:204.62
Existing FAR Area :0.00
Perm.
415.71
Prop.
204.62
Status
OK




[-] Margin Checks (Table 5)
   
[-] Plot Margin (Table 5a)
Building / Wing Road Name Front Side Rear Side Side1 Side2 Status
Reqd. Prop. Reqd. Prop. Reqd. Prop. Reqd. Prop.
A-1 (SMT REKHA DEVI) ROAD WIDENING AREA(SURRENDERED FREE OF COST) 2.00 2.53 1.50 1.60 0.90 1.50 0.90 1.70 OK


[-] BldgLine Margin (Table 5a-1)
Building/Wing Front Side Reqd. Prop. Main Road Name ResvRoad Name Reqd. Width Prop. Width Status
A-1 (SMT REKHA DEVI) BldgLine for 5.40 MTR WIDE ROAD Access Road 0.35 4.53 5.40 MTR WIDE ROAD Access Road ROAD WIDENING AREA(SURRENDERED FREE OF COST) 0.35 2.00 Ok





[-] Inner Building Details (Table 6)
   

No OTS/Duct/VShaft/Balcony/Passage/Lift/Tenements Found.
   


[-] Parking Details (Table 7)
   

NO PARKING CHECK REQUIRED FOR SINGLE DWELLING UNIT. Bungalow/, In Building: A (SMT REKHA DEVI)


NO PARKING CHECK REQUIRED FOR SINGLE DWELLING UNIT. Bungalow/, In Building: A (SMT REKHA DEVI)
   


[-] Exemption Details (Table 8)
   


Not Required to Check StairCase Number Rule.


[-] Staircase Checks (Table 8a-1)


[-] For Building :A (SMT REKHA DEVI)
Floor Name StairCase Name Flight Width Tread Width Riser Height Riser No. On Flight Cabin Ht. Status
Reqd Prop Reqd Prop Perm Prop Perm Prop Reqd Perm Prop
GROUND FLOOR PLAN STAIRCASE 0.750 0.975 0.225 0.250 0.200 0.150 - 10 - - 0.000 OK
FIRST FLOOR PLAN STAIRCASE 0.750 0.975 0.225 0.250 0.200 0.150 - 10 - - 0.000 OK
TERRACE FLOOR PLAN STAIRCASE - 0.975 - 0.250 - 0.000 - 0 2.100 - 2.700 OK

   
   
   
[-] Accessory Use Check (Table 8d)
Accessory Use Name Area Width Depth Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
Sewage Treatment Plant - - 0.91 - - 0.76 - - 1.19 - - 0.00 OK
RAIN WATER HARVESTING - - 1.13 - - 0.96 - - 1.18 - - 0.00 OK
ENT.GATE - - 0.82 - - 0.44 - - 1.85 - - 0.00 OK
SOLAR HEATING SYSTEM - - 1.13 - - 0.96 - - 1.18 - - 0.00 OK


   
   


[-] Floor Details (Table 9)
   

[-] Building:A (SMT REKHA DEVI)


[-] Floor:GROUND FLOOR PLAN



All Dimensions and Area of all the Rooms on this Floor are as per the Rules.

[-] Floor:FIRST FLOOR PLAN



Not Required to Check Dimensions and Area of all the Rooms on this Floor Rule.


   


[-] Summary (Table 10)
   
Name Perm./Reqd. Proposed Status
  Plot Area - 202.35 OK
  Plot Width - 14.30 OK
  Plot Depth - 14.15 OK
  Access Width - 5.40 OK
  Plot Frontage - 14.30 OK
  Coverage Area 141.65 102.31 OK
  FAR Area
Bldg. FAR Area : 204.62
Sanctioned FAR Area :0.00
415.71 204.62 OK





[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use
Plot Width No rule provided for Min. Plot size for proposed Use
Plot Depth No rule provided for Min. Plot size for proposed Use
Access Width The minimum width of abutting road for any Building shall be with respect to Length of Road {As per Rule No. 34 Table No.6}
Plot Frontage No rule provided for Min. Plot size for proposed Use
FAR Area (1) In Old Area, for Residential Building on abutting roadwidth 4.80 (16 ft.) to 6.10 mt., the Floor Area Ratio-FAR shall be 1.8 {As per Rule No.39, Table 15}
(2) For Lohardaga Nagar Parishad Max. 2.0 permissible FAR may be permitted for Residential Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Residential Building on abutting roadwidth 4.80 (16 ft.) to 6.10 mt., the Floor Area Ratio-FAR shall be 1.8 {As per Rule No.39, Table 15}
(2) For Lohardaga Nagar Parishad Max. 2.0 permissible FAR may be permitted for Residential Use {As per Annexure III}
Common Plot Area In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
Common Plot (1) In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
(2) ;
Tree Number 2-4 Trees shall be required for the Plot area upto 250.0 sq.mt. (As per Rule No. 20.1.6)
Margin Rule For Non-highrise Residential Building upto 10.0 mt. Ht. having Plot Depth 10-15 mt. and Plot width 10-15 mt., Margin required in Front shall be 2.0 mt., Rear 1.5 mt. and 0.9 mt. shall be provided on both side. {As per Rule No. 36 (Table 8 & 9)}
Building Line Check The min. width of Road for length of Road Exceeding 100 mt. and upto 300 mt. shall be 6.1 mt. {As per Rule No. 34 Table No. 6 and as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
ResvRoad Width Check The min. width of Road for length of Road Exceeding 100 mt. and upto 300 mt. shall be 6.1 mt. {As per Rule No. 34 Table No. 6 and as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
Building Level
Building Height For Affordable Housing, No height limitation shall be applicable {As per Chapter XI}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.6m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab) for Low income Housing {As per IS Rule No.8888-1978}
(2) The height of all rooms for human habitation shall not be less than 2.6m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab) for Low income Housing {As per IS Rule No.8888-1978}
(3) The height of all rooms for human habitation shall not be less than 2.6m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab) for Low income Housing {As per IS Rule No.8888-1978}
(4) The plinth or any part of a building shall be so located with respect to the surrounding ground level that adequate drainage of the site is assured. The height of the plinth (except in case of stilted parking) shall be not less than 0.45 mt. from the surrounding ground level {As per Rule No. 42.10}
Parapet Height Parapet walls and handrails provided on the edges of roof terraces, balcony, verandah, etc shall not be less than 1.0 m and not more than 1.2 m in height from the finished floor level {As per Rule No. 42.5}
Floor Number For Affordable Housing, No floor number limitation shall be applicable {As per Chapter XI}
StairCase (1) Width of Winding staircase shall be mini. 0.75 mt.,Maximum rise 0.20 mt. & Minimum tread 0.225 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) Width of Winding staircase shall be mini. 0.75 mt.,Maximum rise 0.20 mt. & Minimum tread 0.225 mt. & Cabin height 2.1 mt {As per Rule No. 83.18}
(4) ; No Rule Defined
Plot / Building Level
Accessory Use (1) -
(2) No need to check distance from Building Sewage Treatment Plant
(3) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(4) No need to check distance from Building RAIN WATER HARVESTING
(5) No need to check distance from Building ENT.GATE
(6) -
(7) No need to check distance from Building SOLAR HEATING SYSTEM
Building Level (Rooms)