General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictLOHARDAGA
AuthorityLOHARDAGA NAGAR PARISHAD
Inward_NoLNP/BP/0008/W07/2020
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentNew
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillageHarmu
Taluka26
Architect Details
Architect NameASHWINI KUMAR SAHU
License No.LNP/ENG/0005/2017
Architect AddressNear check post, PWD Road
Architect EmailIDerashwinisahu@gmail.com
Architect Mobile No9308730823
Plot Details
Plot Use Residential
Plot SubUse Bungalow/ Dwelling / Non Apartment
PlotNearbyReligiousStructure NA
Plot/SubPlot NoMS-609
NorthPlot No. - 609
SouthPlot No. - 608
EastRoad Width - 3.65
WestPlot No. - 597
Owner's Details
NameBALRAM KUMAR
AddressNEAR S.P KOTHI , HARMU ,LOHARDAGA
Email IDSOALOHARDAGA@GMAIL.COM
Mobile No7763804000
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Plot area as per Document by Applicant 378.03
2 Physical area measured at site 378.03
3 Area as per Site Visit (Site Visit Report) 378.03
4Area as per Drawing 376.94

Area of Plot Considered : 376.94

[-] Table 2b
Proposal Detail :
UnitMeters
Development Detail :
PlotPLOT
Plot OccupancyResidential
Plot SubUse Bungalow/ Dwelling / Non Apartment
Building StructureNon-Highrise
Building TypeSingle Detached House
Gross Plot Area 376.94
Deduction from Gross Plot area
- Surrender Free of Cost 32.69
32.69
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 344.25
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 294.47
Deductions for Balance Plot Area (from Gross Plot Area)
- Surrender Free of Cost 32.69
- Common Plot 49.79
82.48
Balance Plot Area 294.47

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 60.00 % ) 206.55
Proposed Coverage Area ( 59.93 % ) 206.31
Total Prop. Coverage Area ( 59.93 % ) 206.31
Balance coverage area ( 0.07 % ) 0.24
FAR CHECK
Perm. FAR Area ( 1.50 ) 565.41
Total Perm. FAR area 565.41
Residential FAR 506.60
Proposed FAR Area 519.67
Total Proposed FAR Area 519.67
Consumed FAR (Factor) 1.38
Balance FAR Area 45.74
BUA CHECK
Total Proposed BuiltUp Area 635.55


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Exceeding 50 meter and upto 100 meter -
Existing Road Width 3.6 3.60
Proposed Road Width as per Master Plan 3.6 -
Road Widening Width 3.6 1.50
Plot size (as per measurement) 378.03 376.94

     Plot Related Details
Name Description Unit Reqd Perm Proposed Status
PLOT Plot Area Sq.Mt. - - 344.25 OK
Plot Width Mt. - - 22.54 OK
Plot Depth Mt. - - 15.27 OK
Access Width Mt. - - 3.60 OK
Plot Frontage Mt. - - 21.79 OK
Coverage Area Sq.Mt. - 206.55 206.31 OK
FAR Area Sq.Mt. - 565.41 519.67 OK
Consumed FAR Sq.Mt. - 1.50 1.38 OK
Common Plot Checks Common Plot - Total Area Sq.Mt. 17.21 49.79 OK
Common Plot Tree Cover (Plantation) - Minimum Area Sq.Mt. - 49.79 OK
Tree Cover (Plantation) - Coverage Area Sq.Mt. - - OK
Tree Cover (Plantation) - Width Mt. - 3.01 OK
Tree Cover (Plantation) - Angle Degree - 87.01 OK
Tree Cover (Plantation) - Access Mt. - OK
Tree Tree - Nos Of Trees No. 4 12 OK
A-1 (SHRI BALRAM KUMARSHRI BALRAM KUMAR) Front Margin... ROAD WIDENING AREA(SURRENDERED FREE OF COST) Mt. - - 1000.10 OK
Rear Margin Mt. 1.50 - 1.56 OK
Side1 Margin Mt. 1.50 - 1.65 OK
Side2 Margin Mt. 1.50 - 1.64 OK
A-1 (SHRI BALRAM KUMARSHRI BALRAM KUMAR) BldgLine for 3.60 MTR WIDE FRONT ROAD Access Road Mt. 0.75 4.03 OK
A-1 (SHRI BALRAM KUMARSHRI BALRAM KUMAR) ResvRoad Width Check for... 3.60 MTR WIDE FRONT ROAD Access Road Mt. 0.75 1.50 OK

     Building Related Details
Name Description Unit Reqd Perm Proposed Status
A (SHRI BALRAM KUMARSHRI BALRAM KUMAR) Height Mt. 9.43 9.14 OK
A (SHRI BALRAM KUMARSHRI BALRAM KUMAR) Second Floor - Height Mt. 2.75 - 3.05 OK
Second Floor - Clear Height Mt. 2.75 - 2.93 OK
Second Floor - Beam Clear Height Mt. 2.40 - 2.80 OK
First Floor - Height Mt. 2.75 - 3.05 OK
First Floor - Clear Height Mt. 2.75 - 2.93 OK
First Floor - Beam Clear Height Mt. 2.40 - 2.80 OK
Ground Floor - Height Mt. 2.75 - 3.05 OK
Ground Floor - Clear Height Mt. 2.75 - 2.93 OK
Ground Floor - Beam Clear Height Mt. 2.40 - 2.80 OK
Plinth - Height Mt. 0.45 - 0.61 OK
Plinth - Clear Height Mt. - - 0.61 OK
Plinth - Beam Clear Height Mt. - - 0.61 OK
A (SHRI BALRAM KUMARSHRI BALRAM KUMAR) Terrace Floor - Height Mt. 1.00 1.20 1.07 OK
A (SHRI BALRAM KUMARSHRI BALRAM KUMAR) No. of Floors No. G + 2 3 OK
No. of Tenements No. - 1 OK
GROUND FLOOR PLAN STAIRCASE - Flight Width Mt. 0.900 1.067 OK
STAIRCASE - Tread Width Mt. 0.250 0.254 OK
STAIRCASE - Riser Height Mt. 0.200 0.152 OK
STAIRCASE - Riser No. On Flight No. - 10 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
TERRACE FLOOR PLAN STAIRCASE - Flight Width Mt. - 1.067 OK
STAIRCASE - Tread Width Mt. - 0.254 OK
STAIRCASE - Riser Height Mt. - - OK
STAIRCASE - Riser No. On Flight No. - - OK
STAIRCASE - Cabin Ht. Mt. - - 3.048 OK
FIRST FLOOR PLAN STAIRCASE - Flight Width Mt. 0.900 1.067 OK
STAIRCASE - Tread Width Mt. 0.250 0.254 OK
STAIRCASE - Riser Height Mt. 0.200 0.152 OK
STAIRCASE - Riser No. On Flight No. - 10 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
SECOND FLOOR PLAN STAIRCASE - Flight Width Mt. 0.900 1.067 OK
STAIRCASE - Tread Width Mt. 0.250 0.254 OK
STAIRCASE - Riser Height Mt. 0.200 0.152 OK
STAIRCASE - Riser No. On Flight No. - 10 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
Sewage Treatment Plant Area Sq.Mt. - - 0.94 OK
Width Mt. - - 0.95 OK
Depth Mt. - - 0.99 OK
Height Mt. - - - OK
RAIN WATER HARVESTING Area Sq.Mt. - - 1.42 OK
Width Mt. - - 0.99 OK
Depth Mt. - - 1.44 OK
Height Mt. - - - OK
ENT.GATE Area Sq.Mt. - - 0.88 OK
Width Mt. - - 0.39 OK
Depth Mt. - - 2.26 OK
Height Mt. - - - OK
SOLAR HEATING SYSTEM Area Sq.Mt. - - 0.94 OK
Width Mt. - - 0.95 OK
Depth Mt. - - 0.99 OK
Height Mt. - - - OK
A (SHRI BALRAM KUMARSHRI BALRAM KUMAR) Rain Water Harvesting - No No. 1 - 1 OK
Solar Water Heating System - No No. 1 - 1 OK
Entrance Gate - No No. 1 - 1 OK
   
    All Rooms are as per Rule in Room Checking




[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use
Plot Width No rule provided for Min. Plot size for proposed Use
Plot Depth No rule provided for Min. Plot size for proposed Use
Access Width The minimum width of abutting road for any Building shall be with respect to Length of Road {As per Rule No. 34 Table No.6}
Plot Frontage No rule provided for Min. Plot size for proposed Use
FAR Area (1) In Old Area, for Residential Building on abutting roadwidth 3.60 (12 ft.) to 4.80 mt., the Floor Area Ratio-FAR shall be 1.5 {As per Rule No.39, Table 15}
(2) For Lohardaga Nagar Parishad Max. 2.0 permissible FAR may be permitted for Residential Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Residential Building on abutting roadwidth 3.60 (12 ft.) to 4.80 mt., the Floor Area Ratio-FAR shall be 1.5 {As per Rule No.39, Table 15}
(2) For Lohardaga Nagar Parishad Max. 2.0 permissible FAR may be permitted for Residential Use {As per Annexure III}
Common Plot Area In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
Common Plot (1) In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
(2) ;
Tree Number 4-8 Trees shall be required for the Plot area above 250.0 and upto 1000.0 sq.mt. (As per Rule No. 20.1.6)
Building Line Check The min. width of Road for length of Road Exceeding 50 mt. and upto 100 mt. shall be 5.1 mt. {As per Rule No. 34 Table No. 6}
ResvRoad Width Check The min. width of Road for length of Road Exceeding 50 mt. and upto 100 mt. shall be 5.1 mt. {As per Rule No. 34 Table No. 6}
Building Level
Building Height For old area, on Road width 3.6-4.8 mt., Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 10.0 mt. {As per Rule No. 39.1 Table 15}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(3) The plinth or any part of a building shall be so located with respect to the surrounding ground level that adequate drainage of the site is assured. The height of the plinth (except in case of stilted parking) shall be not less than 0.45 mt. from the surrounding ground level {As per Rule No. 42.10}
Parapet Height Parapet walls and handrails provided on the edges of roof terraces, balcony, verandah, etc shall not be less than 1.0 m and not more than 1.2 m in height from the finished floor level {As per Rule No. 42.5}
Floor Number For old area location,on Road width 3.6-4.8 mt. only G+2 floors shall be allowed {As per Rule No. 39.1 Table 15}
StairCase (1) Width of Winding staircase shall be mini. 0.90 mt.,Maximum rise 0.20 mt. & Minimum tread 0.25 mt. & Cabin Height 2.1 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) No Rule Defined
(4) ; No Rule Defined
Plot / Building Level
Accessory Use (1) -
(2) No need to check distance from Building Sewage Treatment Plant
(3) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(4) No need to check distance from Building RAIN WATER HARVESTING
(5) No need to check distance from Building ENT.GATE
(6) -
(7) No need to check distance from Building SOLAR HEATING SYSTEM
Accessory Use Number (1) Provision of rainwater harvesting shall be mandatory for 300 sqm. and above size of plots-The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area Rain Water Harvesting
(2) For Individual residential buildings having more than 150 sq m. plinth area, Provisions of Solar Water Heating System shall be done Solar Water Heating System
(3) In case of buildings with a height of 15.0 meters and above or ground coverage more than 500 sqm., the main entrance to the premise shall not be less than 5 (five) meters i n width in order to allow easy access to fire engine Entrance Gate
Building Level (Rooms)