No Image Found   

Detail Scrutiny Report

Lohardaga Nagar Parishad

Version Number: 1.0.50  
Version Date: 16/10/2020 
Report Generated On: 03-12-2020 
 
[-] Collapse All


General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictLOHARDAGA
AuthorityLOHARDAGA NAGAR PARISHAD
Inward_NoLNP/BP/0012/W13/2020
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentNew
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillageNadia
Taluka26
Architect Details
Architect NameSUNIL KUMAR
License No.LNP/ENG/0004/2017
Architect AddressBARWATOLI
Architect EmailIDsunil7527@gmail.com
Architect Mobile No7292899641
Plot Details
Plot Use Residential
Plot SubUse Bungalow/ Dwelling / Non Apartment
PlotNearbyReligiousStructure NA
Plot/SubPlot No27/1091
NorthRoad Width - 3.60 MTR WIDE ROAD
SouthPlot No. - NASIM HAIDARI
EastPlot No. - OWNER S PLOT
WestPlot No. - OWNER S PLOT
Owner's Details
NameSAYEED AKHTER
AddressRELIANCE TOWER NEW ROAD LOHARDAG
Email IDhousemap.arc@gmail.com
Mobile No9430731170
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 299.46
2 Plot area as per Document by Applicant 299.46
3 Physical area measured at site 299.46
4 Area as per Site Visit (Site Visit Report) 298.10
5Area as per Drawing 296.17

Area of Plot Considered : 296.17

[-] Table 2b
Proposal Detail :
UnitMeters
Development Detail :
PlotPLOT
Plot OccupancyResidential
Plot SubUse Bungalow/ Dwelling / Non Apartment
Building StructureNon-Highrise
Building TypeSingle Detached House
Gross Plot Area 296.17
Deduction from Gross Plot area
- Surrender Free of Cost 18.89
18.89
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 277.28
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 239.33
Deductions for Balance Plot Area (from Gross Plot Area)
- Surrender Free of Cost 18.89
- Common Plot 37.95
56.84
Balance Plot Area 239.33

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 60.00 % ) 166.37
Proposed Coverage Area ( 34.65 % ) 96.09
Total Prop. Coverage Area ( 34.65 % ) 96.09
Balance coverage area ( 25.35 % ) 70.28
FAR CHECK
Perm. FAR Area ( 1.50 ) 444.26
Total Perm. FAR area 444.26
Residential FAR 192.18
Proposed FAR Area 192.18
Total Proposed FAR Area 192.18
Consumed FAR (Factor) 0.65
Balance FAR Area 252.08
BUA CHECK
Total Proposed BuiltUp Area 192.18


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Exceeding 1000 meter -
Existing Road Width 3.6 3.60
Proposed Road Width as per Master Plan 7.5 -
Road Widening Width 1.95 2.00
Plot size (as per measurement) 298.1 296.17
[-] Extra Land Area Checks
Name Area Status
Reqd Prop
Extra Land - 0.00 OK


[-] Plot Level Checking (Table 3)
   
[-] Common Plot Checks (Table 3b)
Name Total Area Status
Reqd Prop
Common Plot 13.86 37.95 OK


[-] Common Plot Checks (Table 3b)
Name Minimum Area Coverage Area Width Angle Access Status
Reqd Prop Perm Prop Reqd Prop Reqd Prop
Tree Cover (Plantation) - 37.95 0.00 0.00 - 5.24 - 80.36 No Access Provided OK


   
   
[-] Tree Details (Table 3g)
Name Nos Of Trees Status
Reqd Prop
Tree 4 23 OK
   
   
   
   
   


[-] Building Details (Table 4)
   
[-] Building USE/SUBUSE Details Building USE/SUBUSE Details
Building Name Building Use Building SubUse Building Structure
A (SAYEED AKHTER) Residential Bungalow/ Dwelling / Non Apartment Non-Highrise
   
   
   
[-] Height Details (4a)



[-] Total Height (Table 4a-1)
Building Height Height (From GL) Height (From Street LVL) Status
Perm Prop
A (SAYEED AKHTER) 10.00 6.00 6.00 6.00 OK


   
   
[-] Floor Height Check (Table 4a-2)
Building Name Floor Name Height Clear Height Beam Clear Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
A (SAYEED AKHTER) First Floor 2.75 - 3.00 2.75 - 2.90 2.40 - 2.75 OK
Ground Floor 2.75 - 3.00 2.75 - 2.90 2.40 - 2.75 OK
Plinth 0.45 - 0.46 - - 0.46 - - 0.46 OK


[-] Parapet Height Check (Table 4a-2.1)
Building Name Floor Name Height Status
Reqd Perm Prop
A (SAYEED AKHTER) Terrace Floor 1.00 1.20 1.03 OK
   
   
   
[-] Floor Number Check (Table 4a-4)
Building Name No. of Floors No. of Tenements Status
Perm Prop Perm Prop
A (SAYEED AKHTER) G + 2 2 - 1 OK

 
   
    [-] Coverage Check (Table 4b)
Permissible Proposed Status
166.37 96.09 OK
60% 34.65%

[-] Individual Coverage Check
Coverage Area Perm. Prop.
  A-1 (SAYEED AKHTER) - 96.09
  Total Prop. Coverage Area - 96.09
  Total Coverage Area 166.37 96.09

[-] FAR & Tenement Details (Table 4c-1)
Building No. of Same Bldg Total Built Up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
Resi.
A (SAYEED AKHTER) 1 192.18 192.18 192.18 192.18 01
Grand Total : 1 192.18 192.18 192.18 192.18 01


[-] Buildingwise Floor FAR Details
Floor Name Building Name Total
A (SAYEED AKHTER)
Proposed Built Up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Total Proposed Built Up Area (Sq.mt.) Total FAR Area (Sq.mt.)
Ground Floor 96.09 96.09 96.09 96.09
First Floor 96.09 96.09 96.09 96.09
Terrace Floor 0.00 0.00 0.00 0.00
Total : 192.18 192.18 192.18 192.18


[-] UnitBUA Table for Building :A (SAYEED AKHTER)
UnitBUA CALCULATION
FLOOR Name UnitBUA Type UnitBUA Area Carpet Area No. of Rooms No. of Tenement
GROUND FLOOR PLAN SPLIT A FLAT 142.33 142.24 6 1
FIRST FLOOR PLAN SPLIT A FLAT 0.00 0.00 6 0
Total: - - 142.33 142.24 12 1


[-] Building :A (SAYEED AKHTER)
Floor Name Total Built Up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
Resi.
Ground Floor 96.09 96.09 96.09 96.09 01
First Floor 96.09 96.09 96.09 96.09 00
Terrace Floor 0.00 0.00 0.00 0.00 00
Total : 192.18 192.18 192.18 192.18 01
Total Number of Same Buildings : 1
Total : 192.18 192.18 192.18 192.18 01
[-] Table 4c-2

  FAR Area
Building FAR Area:192.18
Existing FAR Area :0.00
Perm.
444.26
Prop.
192.18
Status
OK




[-] Margin Checks (Table 5)
   
[-] Plot Margin (Table 5a)
Building / Wing Road Name Front Side Rear Side Side1 Side2 Status
Reqd. Prop. Reqd. Prop. Reqd. Prop. Reqd. Prop.
A-1 (SAYEED AKHTER) ROAD WIDENING AREA(SURRENDERED FREE OF COST) 4.00 5.10 2.50 10.02 0.90 1.22 - 1.16 OK


[-] BldgLine Margin (Table 5a-1)
Building/Wing Front Side Reqd. Prop. Main Road Name ResvRoad Name Reqd. Width Prop. Width Status
A-1 (SAYEED AKHTER) BldgLine for 3.60 MTR WIDE ROAD Access Road 1.95 7.10 3.60 MTR WIDE ROAD Access Road ROAD WIDENING AREA(SURRENDERED FREE OF COST) 1.95 2.00 Ok





[-] Inner Building Details (Table 6)
   

No OTS/Duct/VShaft/Balcony/Passage/Lift/Tenements Found.
   


[-] Parking Details (Table 7)
   

NO PARKING CHECK REQUIRED FOR SINGLE DWELLING UNIT. Bungalow/ Dwelling / Non Apartment, In Building: A (SAYEED AKHTER)
   


[-] Exemption Details (Table 8)
   


Not Required to Check StairCase Number Rule.


[-] Staircase Checks (Table 8a-1)


[-] For Building :A (SAYEED AKHTER)
Floor Name StairCase Name Flight Width Tread Width Riser Height Riser No. On Flight Cabin Ht. Status
Reqd Prop Reqd Prop Perm Prop Perm Prop Reqd Perm Prop
GROUND FLOOR PLAN Staircase -3FL 0.750 0.991 0.225 0.254 0.200 0.097 - 9 - - 0.000 OK
FIRST FLOOR PLAN Staircase -3FL 0.750 0.991 0.225 0.254 0.200 0.097 - 9 - - 0.000 OK
TERRACE FLOOR PLAN Staircase -3FL - 0.991 - 0.254 - 0.000 - 0 2.100 - 2.534 OK

   
   
   
[-] Accessory Use Check (Table 8d)
Accessory Use Name Area Width Depth Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
Sewage Treatment Plant - - 0.94 - - 0.81 - - 1.15 - - 0.00 OK
RAIN WATER HARVESTING - - 2.02 - - 1.41 - - 1.44 - - 0.00 OK
ENT.GATE - - 1.92 - - 0.57 - - 3.35 - - 0.00 OK
SOLAR HEATING SYSTEM - - 1.34 - - 1.15 - - 1.16 - - 0.00 OK


   
   


[-] Floor Details (Table 9)
   

[-] Building:A (SAYEED AKHTER)


[-] Floor:GROUND FLOOR PLAN



All Dimensions and Area of all the Rooms on this Floor are as per the Rules.

[-] Floor:FIRST FLOOR PLAN



Not Required to Check Dimensions and Area of all the Rooms on this Floor Rule.


   


[-] Summary (Table 10)
   
Name Perm./Reqd. Proposed Status
  Plot Area - 277.28 OK
  Plot Width - 9.44 OK
  Plot Depth - 29.36 OK
  Access Width - 3.60 OK
  Plot Frontage - 9.45 OK
  Coverage Area 166.37 96.09 OK
  FAR Area
Bldg. FAR Area : 192.18
Sanctioned FAR Area :0.00
444.26 192.18 OK





[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use
Plot Width No rule provided for Min. Plot size for proposed Use
Plot Depth No rule provided for Min. Plot size for proposed Use
Access Width The minimum width of abutting road for any Building shall be with respect to Length of Road {As per Rule No. 34 Table No.6}
Plot Frontage No rule provided for Min. Plot size for proposed Use
FAR Area (1) In Old Area, for Residential Building on abutting roadwidth 3.60 (12 ft.) to 4.80 mt., the Floor Area Ratio-FAR shall be 1.5 {As per Rule No.39, Table 15}
(2) For Lohardaga Nagar Parishad Max. 2.0 permissible FAR may be permitted for Residential Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Residential Building on abutting roadwidth 3.60 (12 ft.) to 4.80 mt., the Floor Area Ratio-FAR shall be 1.5 {As per Rule No.39, Table 15}
(2) For Lohardaga Nagar Parishad Max. 2.0 permissible FAR may be permitted for Residential Use {As per Annexure III}
Common Plot Area In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
Common Plot (1) In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
(2) ;
Tree Number 4-8 Trees shall be required for the Plot area above 250.0 and upto 1000.0 sq.mt. (As per Rule No. 20.1.6)
Margin Rule For Non-highrise Residential Building upto 10.0 mt. Ht. having Plot Depth 27-33 mt. and Plot width upto 10 mt., Margin required in Front shall be 4.0 mt., Rear 2.5 mt. and Atleast 0.9 mt. shall be provided at one side. {As per Rule No. 36 (Table 8 & 9)}
Building Line Check The min. width of Road for length of Road Exceeding 300 mt. shall be 7.50 mt. {As per Rule No. 34 Table No. 6}
ResvRoad Width Check The min. width of Road for length of Road Exceeding 300 mt. shall be 7.50 mt. {As per Rule No. 34 Table No. 6}
Building Level
Building Height For old area, on Road width 3.6-4.8 mt., Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 10.0 mt. {As per Rule No. 39.1 Table 15}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(3) The plinth or any part of a building shall be so located with respect to the surrounding ground level that adequate drainage of the site is assured. The height of the plinth (except in case of stilted parking) shall be not less than 0.45 mt. from the surrounding ground level {As per Rule No. 42.10}
Parapet Height Parapet walls and handrails provided on the edges of roof terraces, balcony, verandah, etc shall not be less than 1.0 m and not more than 1.2 m in height from the finished floor level {As per Rule No. 42.5}
Floor Number For old area location,on Road width 3.6-4.8 mt. only G+2 floors shall be allowed {As per Rule No. 39.1 Table 15}
StairCase (1) Width of Winding staircase shall be mini. 0.75 mt.,Maximum rise 0.20 mt. & Minimum tread 0.225 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) Width of Winding staircase shall be mini. 0.75 mt.,Maximum rise 0.20 mt. & Minimum tread 0.225 mt. & Cabin height 2.1 mt {As per Rule No. 83.18}
(4) ; No Rule Defined
Plot / Building Level
Accessory Use (1) -
(2) No need to check distance from Building Sewage Treatment Plant
(3) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(4) No need to check distance from Building RAIN WATER HARVESTING
(5) No need to check distance from Building ENT.GATE
(6) -
(7) No need to check distance from Building SOLAR HEATING SYSTEM
Building Level (Rooms)