No Image Found   

Check List Report

Lohardaga Nagar Parishad

Version Number: 1.0.60  
Version Date: 16/10/2020 
Report Generated On: 24-09-2021 
 

[-] Collapse All


General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictLOHARDAGA
AuthorityLOHARDAGA NAGAR PARISHAD
Inward_NoLNP/BP/0036/W05/2021
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentAddition or Alteration
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillageKaimo
Taluka26
Layout Sanction No10
Layout Sanction Date21/3/2017
Architect Details
Architect NameASHWINI KUMAR SAHU
License No.LNP/ENG/0005/2017
Architect AddressNear check post, PWD Road
Architect EmailIDerashwinisahu@gmail.com
Architect Mobile No9308730823
Plot Details
Plot Use Mixed
Plot SubUse Resi+Comm
PlotNearbyReligiousStructure NA
Plot/SubPlot No1516
NorthRoad Width - 12
SouthPlot No. - 1516
EastPlot No. - 1516
WestRoad Width - 12
Owner's Details
NameGOPI KRISHANA KUNWAR
AddressNEAR ELECTRIC OFFICE LOHARDAGA
Email IDSOALOHARDAGA@GMAIL.COM
Mobile No7004934278
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Plot area as per Document by Applicant 416.02
2 Physical area measured at site 416.02
3 Area as per Site Visit (Site Visit Report) 416.02
4Area as per Drawing 416.02

Area of Plot Considered : 416.02

[-] Table 2b
Proposal Detail :
UnitMeters
Development Detail :
PlotPLOT
Plot OccupancyMixed
Plot SubUse -
Higher Plot Use
Higher Plot Sub UseResi+Comm
Lower Plot Use
Lower Plot Sub Use
Building StructureNon-Highrise
Building TypeSingle Detached House
Gross Plot Area 416.02
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 416.02
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 361.81
Deductions for Balance Plot Area (from Gross Plot Area)
- Common Plot 54.21
54.21
Balance Plot Area 361.81

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 60.00 % ) 249.61
Proposed Coverage Area ( 28.51 % ) 118.59
Total Prop. Coverage Area ( 28.51 % ) 118.59
Balance coverage area ( 31.49 % ) 131.02
FAR CHECK
Perm. FAR Area ( 2.00 ) 832.04
Total Perm. FAR area 832.04
Residential FAR 248.91
Commercial FAR 78.05
Proposed FAR Area 336.76
Total Proposed FAR Area 336.76
Consumed FAR (Factor) 0.81
Balance FAR Area 495.28
BUA CHECK
Total Proposed BuiltUp Area 486.08


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road -
Existing Road Width 12 12.00
Proposed Road Width as per Master Plan 12 -
Road Widening Width 0 -
Plot size (as per measurement) 416.02 416.02

     Plot Related Details
Name Description Unit Reqd Perm Proposed Status
PLOT Plot Area Sq.Mt. - - 416.02 OK
Plot Width Mt. - - 9.17 OK
Plot Depth Mt. - - 45.39 OK
Access Width Mt. - - 12.00 OK
Plot Frontage Mt. - - 9.14 OK
Coverage Area Sq.Mt. - 249.61 118.59 OK
FAR Area Sq.Mt. - 832.04 336.76 OK
Consumed FAR Sq.Mt. - 2.00 0.81 OK
Common Plot Checks Common Plot - Total Area Sq.Mt. 41.60 54.21 OK
Common Plot Tree Cover (Plantation) - Minimum Area Sq.Mt. - 54.21 OK
Tree Cover (Plantation) - Coverage Area Sq.Mt. - - OK
Tree Cover (Plantation) - Width Mt. - 5.95 OK
Tree Cover (Plantation) - Angle Degree - 84.52 OK
Tree Cover (Plantation) - Access Mt. - OK
Tree Tree - Nos Of Trees No. 4 12 OK
Car In Area Sq.Mt. - - 75.00 OK
Total Car In Area Sq.Mt. 25.00 - 75.00 OK
Visitor's Car Parking In Area Sq.Mt. - - 25.00 OK
Total Visitor Parking In Area Sq.Mt. 12.50 - 25.00 OK
TwoWheeler In Area Sq.Mt. - - 26.00 OK
Total TwoWheeler In Area Sq.Mt. 4.00 - 26.00 OK
Other Parking In Area Sq.Mt. - - 69.78 OK
DriveWay PLOT - - - DRIVEWAY - Width No. 3.60 - 4.14 OK
PLOT - - - DRIVEWAY - Width No. 3.60 - 4.14 OK
A (SRI GOPIKRISHNA KUWAR) - BASEMENT FLOOR PLAN - DRIVEWAY - Width No. 3.60 - 5.00 OK
A-1 (SRI GOPIKRISHNA KUWAR) Front Margin... 12.0 MTR WIDE MAIN ROAD Access Road Mt. 4.00 - 11.11 OK
Rear Margin Mt. 4.00 - 18.83 OK
Side1 Margin Mt. 0.90 - 0.96 OK
Side2 Margin Mt. - - 0.00 OK
A-1 (SRI GOPIKRISHNA KUWAR) Basement Front Margin... 12.0 MTR WIDE MAIN ROAD Access Road Mt. 2.00 - 11.11 OK
Basement Rear Margin Mt. 2.00 - 18.83 OK
Basement Side1 Margin Mt. 0.90 - 0.96 OK
Basement Side2 Margin Mt. - - 0.00 OK

     Building Related Details
Name Description Unit Reqd Perm Proposed Status
A (SRI GOPIKRISHNA KUWAR) Height Mt. 23.10 9.45 OK
A (SRI GOPIKRISHNA KUWAR) Second Floor - Height Mt. 2.75 - 3.15 OK
Second Floor - Clear Height Mt. 2.75 - 3.05 OK
Second Floor - Beam Clear Height Mt. 2.40 - 2.92 OK
First Floor - Height Mt. 2.75 - 3.15 OK
First Floor - Clear Height Mt. 2.75 - 3.05 OK
First Floor - Beam Clear Height Mt. 2.40 - 2.92 OK
Ground Floor - Height Mt. 2.75 - 3.15 OK
Ground Floor - Clear Height Mt. 2.75 - 3.05 OK
Ground Floor - Beam Clear Height Mt. 2.40 - 2.92 OK
Basement Floor - Height Mt. 2.40 - 3.15 OK
Basement Floor - Clear Height Mt. 2.40 - 3.05 OK
Basement Floor - Beam Clear Height Mt. 2.10 - 2.92 OK
A (SRI GOPIKRISHNA KUWAR) Terrace Floor - Height Mt. - - 1.07 OK
A (SRI GOPIKRISHNA KUWAR) Basement Floor - Height Below GL Mt. - 3.15 OK
Basement Floor - Area Sq.Mt. - 118.59 OK
Basement Floor - Ventilation Area (Sq.mt.) Sq.Mt. - - OK
A (SRI GOPIKRISHNA KUWAR) Area Sq.Mt. - 118.59 OK
Status - OK
Total Area Sq.Mt. - 118.59 OK
A (SRI GOPIKRISHNA KUWAR) No. of Basement Floor No. 1 1 OK
A (SRI GOPIKRISHNA KUWAR) No. of Floors No. G + 6 3 OK
No. of Tenements No. - 6 OK
BASEMENT FLOOR PLAN STAIRCASE - Flight Width Mt. 0.900 1.016 OK
STAIRCASE - Tread Width Mt. 0.250 0.254 OK
STAIRCASE - Riser Height Mt. 0.200 - OK
STAIRCASE - Riser No. On Flight No. - - OK
STAIRCASE - Cabin Ht. Mt. - - - OK
SECOND FLOOR PLAN STAIRCASE - Flight Width Mt. 0.900 1.016 OK
STAIRCASE - Tread Width Mt. 0.250 0.254 OK
STAIRCASE - Riser Height Mt. 0.200 0.137 OK
STAIRCASE - Riser No. On Flight No. - 12 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
TERRACE FLOOR PLAN STAIRCASE - Flight Width Mt. - 1.016 OK
STAIRCASE - Tread Width Mt. - 0.254 OK
STAIRCASE - Riser Height Mt. - - OK
STAIRCASE - Riser No. On Flight No. - - OK
STAIRCASE - Cabin Ht. Mt. - - 2.591 OK
Sewage Treatment Plant Area Sq.Mt. - - 0.91 OK
Width Mt. - - 0.76 OK
Depth Mt. - - 1.19 OK
Height Mt. - - - OK
RAIN WATER HARVESTING Area Sq.Mt. - - 1.76 OK
Width Mt. - - 1.20 OK
Depth Mt. - - 1.47 OK
Height Mt. - - - OK
ENT.GATE Area Sq.Mt. - - 0.64 OK
Width Mt. - - 0.36 OK
Depth Mt. - - 1.77 OK
Height Mt. - - - OK
Area Sq.Mt. - - 0.64 OK
Width Mt. - - 0.36 OK
Depth Mt. - - 1.77 OK
Height Mt. - - - OK
SOLAR HEATING SYSTEM Area Sq.Mt. - - 1.76 OK
Width Mt. - - 1.20 OK
Depth Mt. - - 1.47 OK
Height Mt. - - - OK
Generator Room Area Sq.Mt. - - 4.00 OK
Width Mt. - - 2.00 OK
Depth Mt. - - 2.00 OK
Height Mt. - - - OK
A (SRI GOPIKRISHNA KUWAR) Rain Water Harvesting - No No. 1 - 1 OK
PLOT 4.31 mt. long 1.50 mt. High 3.69 mt. Wide Natural Slope - Width Mt. - 3.69 OK
4.31 mt. long 1.50 mt. High 3.69 mt. Wide Natural Slope - Depth Mt. - 1.50 OK
4.31 mt. long 1.50 mt. High 3.69 mt. Wide Natural Slope - Slope Ratio - - - OK
Ramp No. A (SRI GOPIKRISHNA KUWAR) - BASEMENT FLOOR PLAN - No. No. 1 1 OK
   
    All Rooms are as per Rule in Room Checking




[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Width No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Depth No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Access Width The minimum width of abutting road for any Building shall be with respect to Length of Road {As per Rule No. 34 Table No.6}
Plot Frontage No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
FAR Area (1) In Old Area, for Non-Residential Building on abutting roadwidth 9.10 (30 ft.) to 12.20 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15}
(2) For Lohardaga Nagar Parishad, Max. 2.0 permissible FAR may be permitted for Commercial or Mercantile type Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Non-Residential Building on abutting roadwidth 9.10 (30 ft.) to 12.20 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15}
(2) For Lohardaga Nagar Parishad, Max. 2.0 permissible FAR may be permitted for Commercial or Mercantile type Use {As per Annexure III}
Common Plot Area In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
Common Plot (1) In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
(2) ;
Tree Number 4-8 Trees shall be required for the Plot area above 250.0 and upto 1000.0 sq.mt. (As per Rule No. 20.1.6)
DriveWay Rule For Plor area upto 2000 sq.mt., the minimum width or driveways should not be less than 3.60 mt. {As per Rule No. 41.2 and modified as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
Margin Rule For Non-highrise Residential Building upto 10.0 mt. Ht. having Plot Depth 39-45 mt. and Plot width upto 10 mt., Margin required in Front shall be 4.0 mt., Rear 4.0 mt. and Atleast 0.9 mt. shall be provided at one side. {As per Rule No. 36 (Table 8 & 9)}
Basement Margin Rule In case of apartment/ group housing/commercial building and basements may be allowed to be constructed under the entire plot area leaving mini. 2 mt. space from the boundary of the premises {As per Rule No. 48}
Building Level
Building Height For old area, on Road width 9.10-12.20 mt., Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 23.10 mt. {As per Rule No. 39.1 Table 15}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(3) o Every basement shall be in every part at least 2.4 m. in height from the floor to the soffit of the roof slab or ceiling and mini. Of 2.1 mr. below the soffit of beams {As per Rule No. 48}
Parapet Height Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
Below GL Floor Height ,
Basement Floor No. Individual residential and small commercial buildings, plot size upto minimum 750 Sq. Meter may have one basement {As per Rule No. 48}
Floor Number For old area location,on Road width 9.1-12.20 mt. only G+6 floors shall be allowed {As per Rule No. 39.1 Table 15}
StairCase (1) Width of Winding staircase shall be mini. 0.90 mt.,Maximum rise 0.20 mt. & Minimum tread 0.25 mt. & Cabin Height 2.1 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) No Rule Defined
(4) ; No Rule Defined
Ramp No Need to Check Natural Slope width, Depth or height. ;
Ramp No. For parking spaces in basements and upper storey of parking floors, if car parking is less then 40 one ramp of minimum of 3.30m width if it is straight and 4.50m width if it is curved shall be provided
Plot / Building Level
Accessory Use (1) -
(2) No need to check distance from Building Sewage Treatment Plant
(3) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(4) No need to check distance from Building RAIN WATER HARVESTING
(5) No need to check distance from Building ENT.GATE
(6) -
(7) No need to check distance from Building SOLAR HEATING SYSTEM
(8) Electric cabin or substation of maximum size of 4 sq.m. with minimum width or diameter of 2 m
(9) No need to check distance from Building Generator Room
Accessory Use Number Provision of Rain Water Harvesting shall be mandatory for any use {Updated as per JBBL, Amendment VIII dated 16/03/2021} Rain Water Harvesting
Building Level (Rooms)