-
No Image Found   

Check List Report

Lohardaga Nagar Parishad

Version Number: 1.0.65  
Version Date: 16/10/2020 
Report Generated On: 03-04-2023 
 

[-] Collapse All


General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictLOHARDAGA
AuthorityLOHARDAGA NAGAR PARISHAD
Inward_NoLNP/BP/0039/W04/2021/ALT2
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentAddition or Alteration
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillageLohardaga
Taluka26
Layout Sanction Date25/10/2021
Architect Details
Architect NameAtaul Haque
License No.LNP/ENG/0001/2021
Architect AddressAzad basti bangla
Architect EmailIDmdataul.haque265@gmail.com
Architect Mobile No9304264642
Plot Details
Plot Use Residential
Plot SubUse Bungalow/ Dwelling / Non Apartment
PlotNearbyReligiousStructure NA
Plot/SubPlot No538/772
North -
South -
East -
West -
Owner's Details
NameBINOD KUMAR MANOJ KUMAR SAROJ KUMAR
AddressNEAR CHEK POST MAIN ROAD LOHARDAGA
Email IDmdataul.haque265@gmail.com
Mobile No9504220500
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 879.07
2 Plot area as per Document by Applicant 879.07
3 Physical area measured at site 879.07
4 Area as per Site Visit (Site Visit Report) 879.07
5Area as per Drawing 381.37

Area of Plot Considered : 381.37

[-] Table 2b
Proposal Detail :
Unit
Development Detail :
PlotPLOT
Plot OccupancyResidential
Plot SubUse Bungalow/ Dwelling / Non Apartment
Building StructureNon-Highrise
Building TypeSingle Detached House
Gross Plot Area 381.37
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 381.37
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 299.78
Deductions for Balance Plot Area (from Gross Plot Area)
- Common Plot 81.59
81.59
Balance Plot Area 299.78

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 60.00 % ) 228.82
Proposed Coverage Area ( 34.28 % ) 130.72
Total Prop. Coverage Area ( 34.28 % ) 130.72
Balance coverage area ( 25.72 % ) 98.10
FAR CHECK
Perm. FAR Area ( 2.000 ) 762.74
Total Perm. FAR area 762.74
Residential FAR 560.44
Proposed FAR Area 560.44
Total Proposed FAR Area 560.44
Consumed FAR (Factor) 1.47
Balance FAR Area 202.30
BUA CHECK
Total Proposed BuiltUp Area 560.44


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Exceeding 1000 meter -
Existing Road Width 12 12.00
Proposed Road Width as per Master Plan 12 -
Road Widening Width 0 -
Plot size (as per measurement) 879.07 381.37
[-] Extra Land Area Checks
Name Area Status
Reqd Prop
Extra Land - 0.00 OK

     Extra Land Area Details
Name Description Unit Reqd Perm Proposed Status
Extra Land Area Details Extra Land Area - - 0.00 OK

     Plot Related Details
Name Description Unit Reqd Perm Proposed Status
PLOT Plot Area Sq.Mt. - - 381.37 OK
Plot Width Mt. - - 13.03 OK
Plot Depth Mt. - - 29.26 OK
Access Width Mt. - - 12.00 OK
Plot Frontage Mt. - - 12.65 OK
Coverage Area Sq.Mt. - 228.82 130.72 OK
FAR Area Sq.Mt. - 762.74 560.44 OK
Consumed FAR Sq.Mt. - 2.00 1.47 OK
Common Plot Checks Common Plot - Total Area Sq.Mt. 19.07 81.59 OK
Common Plot Tree Cover (Plantation) - Minimum Area Sq.Mt. - 81.59 OK
Tree Cover (Plantation) - Coverage Area Sq.Mt. - - OK
Tree Cover (Plantation) - Width Mt. - 4.37 OK
Tree Cover (Plantation) - Angle Degree - 86.41 OK
Tree Cover (Plantation) - Access Mt. - OK
Tree Tree - Nos Of Trees No. 4 4 OK
Car In Area Sq.Mt. - - 50.00 OK
Total Car In Area Sq.Mt. 50.00 - 50.00 OK
Visitor's Car Parking In Area Sq.Mt. - - 12.50 OK
Total Visitor Parking In Area Sq.Mt. 12.50 - 12.50 OK
TwoWheeler In Area Sq.Mt. - - 8.00 OK
Total TwoWheeler In Area Sq.Mt. - - 8.00 OK
DriveWay PLOT - - - driveway 3.65 m - Width No. 3.60 - 3.65 OK
ABC-1 (123) Front Margin... 12 M MAINROAD Access Road Mt. 4.00 - 8.50 OK
Rear Margin Mt. 3.00 - 4.00 OK
Side1 Margin Mt. 0.90 - 1.20 OK
Side2 Margin Mt. 0.90 - 3.93 OK

     Building Related Details
Name Description Unit Reqd Perm Proposed Status
ABC (123) Height Mt. 23.10 12.00 OK
ABC (123) Third Floor - Height Mt. 2.75 - 3.00 OK
Third Floor - Clear Height Mt. 2.75 - 2.90 OK
Third Floor - Beam Clear Height Mt. 2.40 - 2.75 OK
Second Floor - Height Mt. 2.75 - 3.00 OK
Second Floor - Clear Height Mt. 2.75 - 2.90 OK
Second Floor - Beam Clear Height Mt. 2.40 - 2.75 OK
First Floor - Height Mt. 2.75 - 3.00 OK
First Floor - Clear Height Mt. 2.75 - 2.90 OK
First Floor - Beam Clear Height Mt. 2.40 - 2.75 OK
Ground Floor - Height Mt. 2.75 - 3.00 OK
Ground Floor - Clear Height Mt. 2.75 - 2.90 OK
Ground Floor - Beam Clear Height Mt. 2.40 - 2.75 OK
Plinth - Height Mt. 0.45 - 0.60 OK
Plinth - Clear Height Mt. - - 0.60 OK
Plinth - Beam Clear Height Mt. - - 0.60 OK
ABC (123) Terrace Floor - Height Mt. - - 0.90 OK
Terrace Floor - Clear Height Mt. - - 0.90 OK
Terrace Floor - Beam Clear Height Mt. - - 0.90 OK
ABC (123) No. of Floors No. G + 6 4 OK
No. of Tenements No. - 4 OK
TERRACE FLOOR PLAN STAIRCASE - Flight Width Mt. - 1.200 OK
STAIRCASE - Tread Width Mt. - 0.250 OK
STAIRCASE - Riser Height Mt. - - OK
STAIRCASE - Riser No. On Flight No. - - OK
STAIRCASE - Cabin Ht. Mt. - - 2.600 OK
THIRD FLOOR PLAN STAIRCASE - Flight Width Mt. 0.900 1.200 OK
STAIRCASE - Tread Width Mt. 0.250 0.250 OK
STAIRCASE - Riser Height Mt. 0.200 0.167 OK
STAIRCASE - Riser No. On Flight No. - 9 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
SUMP TANK Area Sq.Mt. - - 2.35 OK
Width Mt. - - 0.84 OK
Depth Mt. - - 2.81 OK
Height Mt. - - - OK
RAIN WATER HARVESTING Area Sq.Mt. - - 0.22 OK
Width Mt. - - 0.53 OK
Depth Mt. - - 0.53 OK
Height Mt. - - - OK
ENT.GATE Area Sq.Mt. - - 0.03 OK
Width Mt. - - 0.08 OK
Depth Mt. - - 0.34 OK
Height Mt. - - - OK
ABC (123) Rain Water Harvesting - No No. 1 - 1 OK
Entrance Gate - No No. 1 - 1 OK
   
    All Rooms are as per Rule in Room Checking




[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Width No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Depth No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Access Width The minimum width of abutting road for any Building shall be with respect to Length of Road {As per Rule No. 34 Table No.6}
Plot Frontage No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
FAR Area (1) In Old Area, for Residential Building on abutting roadwidth 9.10 (30 ft.) to 12.20 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15}
(2) For Lohardaga Nagar Parishad Max. 2.0 permissible FAR may be permitted for Residential Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Residential Building on abutting roadwidth 9.10 (30 ft.) to 12.20 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15}
(2) For Lohardaga Nagar Parishad Max. 2.0 permissible FAR may be permitted for Residential Use {As per Annexure III}
Common Plot Area In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
Common Plot (1) In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
(2) ;
Tree Number 4-8 Trees shall be required for the Plot area above 250.0 and upto 1000.0 sq.mt. (As per Rule No. 20.1.6)
DriveWay Rule For Plor area upto 2000 sq.mt., the minimum width or driveways should not be less than 3.60 mt. {As per Rule No. 41.2 and modified as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
Margin Rule For Non-highrise Residential Building 10-13.3 mt. Ht. having Plot Depth 27-33 mt. and Plot width 10-15 mt., Margin required in Front shall be 4.0 mt., Rear 3.0 mt. and 0.9 mt. shall be provided on both side. {As per Rule No. 36 (Table 8 & 9)}
Building Level
Building Height For old area, on Road width 9.10-12.20 mt., Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 23.10 mt. {As per Rule No. 39.1 Table 15}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(3) The plinth or any part of a building shall be so located with respect to the surrounding ground level that adequate drainage of the site is assured. The height of the plinth (except in case of stilted parking) shall be not less than 0.45 mt. from the surrounding ground level {As per Rule No. 42.10}
Parapet Height (1) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
(2) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
(3) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
Floor Number For old area location,on Road width 9.1-12.20 mt. only G+6 floors shall be allowed {As per Rule No. 39.1 Table 15}
StairCase (1) No Rule Defined
(2) ; No Rule Defined
(3) Width of Winding staircase shall be mini. 0.90 mt.,Maximum rise 0.20 mt. & Minimum tread 0.25 mt. & Cabin Height 2.1 mt. {As per Rule No. 83.18}
(4) ; No Rule Defined
Plot / Building Level
Accessory Use (1) -
(2) No need to check distance from Building SUMP TANK
(3) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(4) No need to check distance from Building RAIN WATER HARVESTING
(5) No need to check distance from Building ENT.GATE
Accessory Use Number (1) Provision of Rain Water Harvesting shall be mandatory for any use {Updated as per JBBL, Amendment VIII dated 16/03/2021} Rain Water Harvesting
(2) In case of buildings with a height of 15.0 meters and above or ground coverage more than 500 sqm., the main entrance to the premise shall not be less than 5 (five) meters i n width in order to allow easy access to fire engine Entrance Gate
Building Level (Rooms)