No Image Found   

Detail Scrutiny Report

Lohardaga Nagar Parishad

Version Number: 1.0.61  
Version Date: 16/10/2020 
Report Generated On: 17-11-2021 
 
[-] Collapse All


General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictLOHARDAGA
AuthorityLOHARDAGA NAGAR PARISHAD
Inward_NoLNP/BP/0052/W18/2021
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentNew
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillageBadla
Taluka26
Architect Details
Architect NameASHWINI KUMAR SAHU
License No.LNP/ENG/0005/2017
Architect AddressNear check post, PWD Road
Architect EmailIDerashwinisahu@gmail.com
Architect Mobile No9308730823
Plot Details
Plot Use Mixed
Plot SubUse Resi+Comm
PlotNearbyReligiousStructure NA
Plot/SubPlot No3118/3549
NorthPlot No. - 3118
SouthPlot No. - 3119, 3117
EastPlot No. - 3117, 3549
WestRoad Width - 7.60
Owner's Details
NameSEEMA DEVI
AddressBAKSHIDEEPA LOHARDAGA
Email IDSOALOHARDAGA@GMAIL.COM
Mobile No6206138266
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Plot area as per Document by Applicant 1036.20
2 Physical area measured at site 1036.20
3 Area as per Site Visit (Site Visit Report) 1036.20
4Area as per Drawing 1035.76

Area of Plot Considered : 1035.76

[-] Table 2b
Proposal Detail :
UnitMeters
Development Detail :
PlotPLOT
Plot OccupancyMixed
Plot SubUse -
Higher Plot Use
Higher Plot Sub UseResi+Comm
Lower Plot Use
Lower Plot Sub Use
Building StructureNon-Highrise
Building TypeSingle Detached House
Gross Plot Area 1035.76
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 1035.76
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 918.68
Deductions for Balance Plot Area (from Gross Plot Area)
- Common Plot 117.08
117.08
Balance Plot Area 918.68

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 50.00 % ) 517.88
Proposed Coverage Area ( 32.20 % ) 333.54
Total Prop. Coverage Area ( 32.2 % ) 333.54
Balance coverage area ( 17.80 % ) 184.34
FAR CHECK
Perm. FAR Area ( 2.00 ) 2071.52
Total Perm. FAR area 2071.52
Residential FAR 333.54
Commercial FAR 667.08
Proposed FAR Area 1000.62
Total Proposed FAR Area 1000.62
Consumed FAR (Factor) 0.97
Balance FAR Area 1070.90
BUA CHECK
Total Proposed BuiltUp Area 1000.62


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Exceeding 1000 meter -
Existing Road Width 7.6 7.60
Proposed Road Width as per Master Plan 7.6 -
Road Widening Width 0 -
Plot size (as per measurement) 1036.2 1035.76


[-] Plot Level Checking (Table 3)
   
[-] Common Plot Checks (Table 3b)
Name Total Area Status
Reqd Prop
Common Plot 103.58 117.08 OK


[-] Common Plot Checks (Table 3b)
Name Minimum Area Coverage Area Width Angle Access Status
Reqd Prop Perm Prop Reqd Prop Reqd Prop
Tree Cover (Plantation) - 117.08 0.00 0.00 - 5.14 - 89.26 3.6 MTR WIDE MAIN ROAD Access Road OK


   
   
[-] Tree Details (Table 3g)
Name Nos Of Trees Status
Reqd Prop
Tree 8 26 OK
   
   
   
   
   


[-] Building Details (Table 4)
   
[-] Building USE/SUBUSE Details Building USE/SUBUSE Details
Building Name Building Use Building SubUse Building Structure
A (SMT SEEMA DEVI) Commercial ResiComm Bldg Non-Highrise
   
   
   
[-] Height Details (4a)



[-] Total Height (Table 4a-1)
Building Height Height (From GL) Height (From Street LVL) Status
Perm Prop
A (SMT SEEMA DEVI) 19.25 9.30 9.30 9.30 OK


   
   
[-] Floor Height Check (Table 4a-2)
Building Name Floor Name Height Clear Height Beam Clear Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
A (SMT SEEMA DEVI) Second Floor 2.75 - 3.10 2.75 - 3.00 2.40 - 2.87 OK
First Floor 2.75 - 3.10 2.75 - 3.00 2.40 - 2.87 OK
Ground Floor 2.75 - 3.10 2.75 - 3.00 2.40 - 2.87 OK
Plinth 0.45 - 0.60 - - 0.60 - - 0.60 OK


[-] Parapet Height Check (Table 4a-2.1)
Building Name Floor Name Height Status
Reqd Perm Prop
A (SMT SEEMA DEVI) Terrace Floor - - 1.05 OK
   
   
   
[-] Floor Number Check (Table 4a-4)
Building Name No. of Floors No. of Tenements Status
Perm Prop Perm Prop
A (SMT SEEMA DEVI) G + 5 3 - 6 OK

 
   
    [-] Coverage Check (Table 4b)
Permissible Proposed Status
517.88 333.54 OK
50% 32.2%

[-] Individual Coverage Check
Coverage Area Perm. Prop.
  A-1 (SMT SEEMA DEVI) - 333.54
  Total Prop. Coverage Area - 333.54
  Total Coverage Area 517.88 333.54

[-] FAR & Tenement Details (Table 4c-1)
Building No. of Same Bldg Total Built Up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
Resi. Commercial
A (SMT SEEMA DEVI) 1 1000.62 333.54 667.08 1000.62 1000.62 06
Grand Total : 1 1000.62 333.54 667.08 1000.62 1000.62 06


[-] Buildingwise Floor FAR Details
Floor Name Building Name Total
A (SMT SEEMA DEVI)
Proposed Built Up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Total Proposed Built Up Area (Sq.mt.) Total FAR Area (Sq.mt.)
Ground Floor 333.54 333.54 333.54 333.54
First Floor 333.54 333.54 333.54 333.54
Second Floor 333.54 333.54 333.54 333.54
Terrace Floor 0.00 0.00 0.00 0.00
Total : 1000.62 1000.62 1000.62 1000.62


[-] UnitBUA Table for Building :A (SMT SEEMA DEVI)
UnitBUA CALCULATION
FLOOR Name UnitBUA Type UnitBUA Area Carpet Area No. of Rooms No. of Tenement
GROUND FLOOR PLAN HALL SHOP 172.54 172.22 4 2
HALL-1 SHOP 112.67 112.48 3
FIRST FLOOR PLAN HALL SHOP 172.54 172.22 4 2
HALL-1 SHOP 112.67 112.48 3
SECOND FLOOR PLAN HALL FLAT 172.54 172.22 4 2
HALL-1 FLAT 112.67 112.48 3
Total: - - 855.60 854.10 21 6


[-] Building :A (SMT SEEMA DEVI)
Floor Name Total Built Up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
Resi. Commercial
Ground Floor 333.54 0.00 333.54 333.54 333.54 02
First Floor 333.54 0.00 333.54 333.54 333.54 02
Second Floor 333.54 333.54 0.00 333.54 333.54 02
Terrace Floor 0.00 0.00 0.00 0.00 0.00 00
Total : 1000.62 333.54 667.08 1000.62 1000.62 06
Total Number of Same Buildings : 1
Total : 1000.62 333.54 667.08 1000.62 1000.62 06
[-] Table 4c-2

  FAR Area
Building FAR Area:1000.62
Existing FAR Area :0.00
Perm.
2071.52
Prop.
1000.62
Status
OK




[-] Margin Checks (Table 5)
   
[-] Plot Margin (Table 5a)
Building / Wing Road Name Front Side Rear Side Side1 Side2 Status
Reqd. Prop. Reqd. Prop. Reqd. Prop. Reqd. Prop.
A-1 (SMT SEEMA DEVI) 7.60 MTR WIDE MAIN ROAD Access Road 9.00 9.10 6.00 5.08 6.00 3.00 6.00 3.18 Failed






[-] Inner Building Details (Table 6)
   

No OTS/Duct/VShaft/Balcony/Passage/Lift/Tenements Found.
   


[-] Parking Details (Table 7)
   
[-] Required Parking(Table 7a)
Building Name Type SubUse Area (Sq.mt.) Units Car Visitors Car TwoWheeler
Reqd. Prop. Reqd./Unit Reqd. Prop. Reqd./Unit Reqd. Prop. Reqd./Unit Reqd. Prop.
A (SMT SEEMA DEVI) Commercial Shop > 0 50 607.70 1 9 - - - - - - -
> 0 50 607.70 - - - - - - 1 26 -
Residential Residential Bldg/Apartment > 0 1 2.00 1 2 - - - - - - -
> 0 1 2.00 - - - - - - 1 2 -
> 0 1 2.00 - - - 1 1 - - - -
Total : - - - - 11 6 - 1 2 - 28 20

[-] Parking Check (Table 7b)
Vehicle Type Reqd. Prop. Status
No. Area No. Area
Car - - 6 75.00 OK
Total Car 11 137.50 6 75.00 FAILED
Visitor's Car Parking - - 2 25.00 OK
Total Visitor Parking 1 12.50 2 25.00 OK
TwoWheeler - - 20 40.00 OK
Total TwoWheeler 28 56.00 20 40.00 FAILED
Total 206.00 180.00 FAILED

Individual Parking Checks (Table 7c)
Dimensions and Area for all Vehicle(s) are as per the Rules

[-] Driveway Parking Checks (Table 7d)
Building/Plot Name Floor Name Driveway Name Width Status
Reqd Perm Prop
PLOT - DRIVEWAY 3.60 - 5.49 OK

   


[-] Exemption Details (Table 8)
   


Not Required to Check StairCase Number Rule.


[-] Staircase Checks (Table 8a-1)


[-] For Building :A (SMT SEEMA DEVI)
Floor Name StairCase Name Flight Width Tread Width Riser Height Riser No. On Flight Cabin Ht. Status
Reqd Prop Reqd Prop Perm Prop Perm Prop Reqd Perm Prop
GROUND FLOOR PLAN STAIRCASE 0.900 1.200 0.250 0.250 0.200 0.148 - 5 - - 0.000 OK
STAIRCASE 0.900 1.125 0.250 0.250 0.200 0.155 - 10 - - 0.000 OK
FIRST FLOOR PLAN STAIRCASE 0.900 1.200 0.250 0.250 0.200 0.148 - 5 - - 0.000 OK
STAIRCASE 0.900 1.125 0.250 0.250 0.200 0.155 - 10 - - 0.000 OK
SECOND FLOOR PLAN STAIRCASE 0.900 1.200 0.250 0.250 0.200 0.148 - 5 - - 0.000 OK
STAIRCASE 0.900 1.125 0.250 0.250 0.200 0.155 - 10 - - 0.000 OK
TERRACE FLOOR PLAN STAIRCASE - 1.200 - 0.250 - 0.000 - 0 - - 2.550 OK
STAIRCASE - 1.125 - 0.250 - 0.000 - 0 - - 2.550 OK

   
   
   
[-] Accessory Use Check (Table 8d)
Accessory Use Name Area Width Depth Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
Sewage Treatment Plant - - 0.91 - - 0.76 - - 1.19 - - 0.00 OK
RAIN WATER HARVESTING - - 1.76 - - 1.20 - - 1.47 - - 0.00 OK
ENT.GATE - - 0.64 - - 0.36 - - 1.77 - - 0.00 OK
SOLAR HEATING SYSTEM - - 1.76 - - 1.20 - - 1.47 - - 0.00 OK
Generator Room - - 1.96 - - 1.40 - - 1.40 - - 0.00 OK





[-] Accessory Use No. Checks
Building Name Accessory Use Name No Status
Reqd Perm Prop
A (SMT SEEMA DEVI) Rain Water Harvesting 1 - 1 OK
Entrance Gate 1 - 1 OK
   
   


[-] Floor Details (Table 9)
   

[-] Building:A (SMT SEEMA DEVI)


[-] Floor:GROUND FLOOR PLAN



Not Required to Check Dimensions and Area of all the Rooms on this Floor Rule.

[-] Floor:FIRST FLOOR PLAN



Not Required to Check Dimensions and Area of all the Rooms on this Floor Rule.

[-] Floor:SECOND FLOOR PLAN



All Dimensions and Area of all the Rooms on this Floor are as per the Rules.


   


[-] Summary (Table 10)
   
Name Perm./Reqd. Proposed Status
  Plot Area - 1035.76 OK
  Plot Width - 22.34 OK
  Plot Depth - 46.35 OK
  Access Width - 7.60 OK
  Plot Frontage - 21.90 OK
  Coverage Area 517.88 333.54 OK
  FAR Area
Bldg. FAR Area : 1000.62
Sanctioned FAR Area :0.00
2071.52 1000.62 OK





[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Width No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Depth No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Access Width The minimum width of abutting road for any Building shall be with respect to Length of Road {As per Rule No. 34 Table No.6}
Plot Frontage No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
FAR Area (1) In Old Area, for Non-Residential Building on abutting roadwidth 7.5 (25 ft.) to 9.10 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15}
(2) For Lohardaga Nagar Parishad, Max. 2.0 permissible FAR may be permitted for Commercial or Mercantile type Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Non-Residential Building on abutting roadwidth 7.5 (25 ft.) to 9.10 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15}
(2) For Lohardaga Nagar Parishad, Max. 2.0 permissible FAR may be permitted for Commercial or Mercantile type Use {As per Annexure III}
Common Plot Area In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
Common Plot (1) In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
(2) ;
Tree Number Mini. 8 Trees shall be required for the Plot area above 1000.0 sq.mt. (As per Rule No. 20.1.6)
DriveWay Rule For Plor area upto 2000 sq.mt., the minimum width or driveways should not be less than 3.60 mt. {As per Rule No. 41.2 and modified as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
Margin Rule For Commercial & Storage buildings having plotarea above 1000 sq.mt., Margin required in Front shall be 9.0 mt., Rear 6.0 mt. and 6.0 mt. shall be provided on both side. {As per Rule No. 38.2.5}
Building Level
Building Height For old area, on Road width 7.50-9.10 mt., Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 19.25 mt. {As per Rule No. 39.1 Table 15}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(3) The plinth or any part of a building shall be so located with respect to the surrounding ground level that adequate drainage of the site is assured. The height of the plinth (except in case of stilted parking) shall be not less than 0.45 mt. from the surrounding ground level {As per Rule No. 42.10}
Parapet Height Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
Floor Number For old area location,on Road width 7.5-9.1 mt. only G+5 floors shall be allowed {As per Rule No. 39.1 Table 15}
StairCase (1) Width of Winding staircase shall be mini. 0.90 mt.,Maximum rise 0.20 mt. & Minimum tread 0.25 mt. & Cabin Height 2.1 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) No Rule Defined
(4) ; No Rule Defined
Plot / Building Level
Accessory Use (1) -
(2) No need to check distance from Building Sewage Treatment Plant
(3) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(4) No need to check distance from Building RAIN WATER HARVESTING
(5) No need to check distance from Building ENT.GATE
(6) -
(7) No need to check distance from Building SOLAR HEATING SYSTEM
(8) Electric cabin or substation of maximum size of 4 sq.m. with minimum width or diameter of 2 m
(9) No need to check distance from Building Generator Room
Accessory Use Number (1) Provision of Rain Water Harvesting shall be mandatory for any use {Updated as per JBBL, Amendment VIII dated 16/03/2021} Rain Water Harvesting
(2) In case of buildings with a height of 15.0 meters and above or ground coverage more than 500 sqm., the main entrance to the premise shall not be less than 5 (five) meters i n width in order to allow easy access to fire engine Entrance Gate
Building Level (Rooms)