Check List Report

Lohardaga Nagar Parishad

Version Number: 1.0.62  
Version Date: 16/10/2020 
Report Generated On: 03-08-2022 
 

[-] Collapse All


General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictLOHARDAGA
AuthorityLOHARDAGA NAGAR PARISHAD
Inward_NoLNP/BP/0029/W22/2022
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentNew
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillageBadla
Taluka26
Architect Details
Architect NameANUP KUMAR SINHA
License No.LNP/ARC/0001/2018
Architect Address3rd Floor, Roshpa Tower, Main Road, Ranchi
Architect EmailIDtheaksassociates@gmail.com
Architect Mobile No8986652248
Plot Details
Plot Use Residential
Plot SubUse MultiDwelling Units
PlotNearbyReligiousStructure NA
Plot/SubPlot No3569
NorthPlot No. - 3569
SouthPlot No. - 3570
EastPlot No. - 3615
WestRoad Width - 50
Owner's Details
NameMOUSMI PAUL
AddressC/O, SANTOSH KUMAR ASHOK NAGAR, NEAR BANK OF BARODA, THAKURAIN TALAB, LOHARDAGA.
Email IDsantosh1396@gmail.com
Mobile No6392055279
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 344.00
2 Plot area as per Document by Applicant 344.00
3 Physical area measured at site 344.00
4 Area as per Site Visit (Site Visit Report) 344.00
5Area as per Drawing 351.17

Area of Plot Considered : 344.00

Plot area provided in drawing shall not be more than Plot area as per Document.
[-] Table 2b
Proposal Detail :
Unit
Development Detail :
PlotPLOT
Plot OccupancyResidential
Plot SubUse MultiDwelling Units
Building StructureNon-Highrise
Building TypeSingle Detached House
Gross Plot Area 344.00
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 344.00
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 299.76
Deductions for Balance Plot Area (from Gross Plot Area)
- Common Plot 44.24
44.24
Balance Plot Area 299.76

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 60.00 % ) 206.40
Proposed Coverage Area ( 25.77 % ) 88.64
Total Prop. Coverage Area ( 25.77 % ) 88.64
Balance coverage area ( 34.23 % ) 117.76
FAR CHECK
Perm. FAR Area ( 2.00 ) 688.00
Total Perm. FAR area 688.00
Residential FAR 265.93
Proposed FAR Area 265.93
Total Proposed FAR Area 265.93
Consumed FAR (Factor) 0.77
Balance FAR Area 422.07
BUA CHECK
Total Proposed BuiltUp Area 265.92


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Exceeding 1000 meter -
Existing Road Width 15.24 15.24
Proposed Road Width as per Master Plan 15.24 -
Road Widening Width 0 -
Plot size (as per measurement) 344 351.17
[-] Extra Land Area Checks
Name Area Status
Reqd Prop
Extra Land - 0.00 OK

     Extra Land Area Details
Name Description Unit Reqd Perm Proposed Status
Extra Land Area Details Extra Land Area - - 0.00 OK

     Plot Related Details
Name Description Unit Reqd Perm Proposed Status
PLOT Plot Area Sq.Mt. - - 344.00 OK
Plot Width Mt. - - 4.57 OK
Plot Depth Mt. - - 76.81 OK
Access Width Mt. - - 15.24 OK
Plot Frontage Mt. - - 4.57 OK
Coverage Area Sq.Mt. - 206.40 88.64 OK
FAR Area Sq.Mt. - 688.00 265.93 OK
Consumed FAR Sq.Mt. - 2.00 0.77 OK
Common Plot Checks Common Plot - Total Area Sq.Mt. 34.40 44.24 OK
Common Plot Normal Open Space - Minimum Area Sq.Mt. - 20.23 OK
Normal Open Space - Access Mt. - OK
Normal Open Space - Minimum Area Sq.Mt. - 24.00 OK
Normal Open Space - Access Mt. - OK
Tree Tree - Nos Of Trees No. 4 6 OK
A-1 (RESIDENTIAL G2) Front Margin... 15.24 M WIDE ROAD Mt. 4.00 - 8.59 OK
Rear Margin Mt. 4.00 - 43.41 OK
Side1 Margin Mt. 1.00 - 0.00 Failed
Side2 Margin Mt. 1.00 - 1.00 OK

     Building Related Details
Name Description Unit Reqd Perm Proposed Status
A (RESIDENTIAL G2) Height Mt. 30.00 9.00 OK
A (RESIDENTIAL G2) Second Floor - Height Mt. 2.75 - 3.00 OK
Second Floor - Clear Height Mt. 2.75 - 2.90 OK
Second Floor - Beam Clear Height Mt. 2.40 - 2.65 OK
First Floor - Height Mt. 2.75 - 3.00 OK
First Floor - Clear Height Mt. 2.75 - 2.90 OK
First Floor - Beam Clear Height Mt. 2.40 - 2.65 OK
Ground Floor - Height Mt. 2.75 - 3.00 OK
Ground Floor - Clear Height Mt. 2.75 - 2.90 OK
Ground Floor - Beam Clear Height Mt. 2.40 - 2.65 OK
Plinth - Height Mt. 0.45 - 0.60 OK
Plinth - Clear Height Mt. - - 0.60 OK
Plinth - Beam Clear Height Mt. - - 0.60 OK
A (RESIDENTIAL G2) Terrace Floor - Height Mt. - - 1.00 OK
A (RESIDENTIAL G2) No. of Floors No. - 3 OK
No. of Tenements No. - 1 OK
GROUND FLOOR PLAN Staircase -3FL - Flight Width Mt. 0.900 0.914 OK
Staircase -3FL - Tread Width Mt. 0.250 0.250 OK
Staircase -3FL - Riser Height Mt. 0.200 0.097 OK
Staircase -3FL - Riser No. On Flight No. - 9 OK
Staircase -3FL - Cabin Ht. Mt. - - - OK
TYPICAL - 1& 2 FLOOR PLAN Staircase -3FL - Flight Width Mt. 0.900 0.914 OK
Staircase -3FL - Tread Width Mt. 0.250 0.250 OK
Staircase -3FL - Riser Height Mt. 0.200 0.097 OK
Staircase -3FL - Riser No. On Flight No. - 9 OK
Staircase -3FL - Cabin Ht. Mt. - - - OK
TERRACE FLOOR PLAN HEADROOM - Flight Width Mt. - 0.914 OK
HEADROOM - Tread Width Mt. - 0.250 OK
HEADROOM - Riser Height Mt. - - OK
HEADROOM - Riser No. On Flight No. - - OK
HEADROOM - Cabin Ht. Mt. - - 2.400 OK
SEPTIC TANK Area Sq.Mt. - - 1.04 OK
Width Mt. - - 0.67 OK
Depth Mt. - - 1.61 OK
Height Mt. - - - OK
RAIN WATER HARVESTING Area Sq.Mt. - - 0.61 OK
Width Mt. - - 0.70 OK
Depth Mt. - - 0.88 OK
Height Mt. - - - OK
ENT.GATE Area Sq.Mt. - - 0.26 OK
Width Mt. - - 0.16 OK
Depth Mt. - - 1.67 OK
Height Mt. - - - OK
SOLAR HEATING SYSTEM Area Sq.Mt. - - 1.78 OK
Width Mt. - - 1.29 OK
Depth Mt. - - 1.39 OK
Height Mt. - - - OK
A (RESIDENTIAL G2) Rain Water Harvesting - No No. 1 - 1 OK
   
    All Rooms are as per Rule in Room Checking




[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Width No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Depth No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Access Width The minimum width of abutting road for any Building shall be with respect to Length of Road {As per Rule No. 34 Table No.6}
Plot Frontage No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
FAR Area (1) In Old Area, for Residential Building on abutting roadwidth 12.20 (40 ft.) to 18.30 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15}
(2) For Lohardaga Nagar Parishad Max. 2.0 permissible FAR may be permitted for Residential Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Residential Building on abutting roadwidth 12.20 (40 ft.) to 18.30 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15}
(2) For Lohardaga Nagar Parishad Max. 2.0 permissible FAR may be permitted for Residential Use {As per Annexure III}
Common Plot Area In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
Common Plot (1) ;
(2) ;
(3) ; ;
Tree Number 4-8 Trees shall be required for the Plot area above 250.0 and upto 1000.0 sq.mt. (As per Rule No. 20.1.6)
Margin Rule For narrow plots,the setbacks on sides may be compensated in front and rear setbacks so as to ensure that the overall aggregate setbacks are maintained in the site, subject to maintaining a minimum of side setback of 1m in case of buildings of height up to 10.0 mt.
Building Level
Building Height For old area, on Road width 12.20-18.30 mt., Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 30.0 mt. {As per Rule No. 39.1 Table 15}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(3) The plinth or any part of a building shall be so located with respect to the surrounding ground level that adequate drainage of the site is assured. The height of the plinth (except in case of stilted parking) shall be not less than 0.45 mt. from the surrounding ground level {As per Rule No. 42.10}
Parapet Height Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
Floor Number For old area location,on Road width 12.20-18.30 mt., Maximum Height 30 meter shall be allowed. {As per Rule No. 39.1 Table 15}
StairCase (1) Width of Winding staircase shall be mini. 0.90 mt.,Maximum rise 0.20 mt. & Minimum tread 0.25 mt. & Cabin Height 2.1 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) No Rule Defined
(4) ; No Rule Defined
Plot / Building Level
Accessory Use (1) -
(2) No need to check distance from Building SEPTIC TANK
(3) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(4) No need to check distance from Building RAIN WATER HARVESTING
(5) No need to check distance from Building ENT.GATE
(6) -
(7) No need to check distance from Building SOLAR HEATING SYSTEM
Accessory Use Number Provision of Rain Water Harvesting shall be mandatory for any use {Updated as per JBBL, Amendment VIII dated 16/03/2021} Rain Water Harvesting
Building Level (Rooms)