No Image Found   

Detail Scrutiny Report

Lohardaga Nagar Parishad

Version Number: 1.0.62  
Version Date: 16/10/2020 
Report Generated On: 03-08-2022 
 
[-] Collapse All


General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictLOHARDAGA
AuthorityLOHARDAGA NAGAR PARISHAD
Inward_NoLNP/BP/0029/W22/2022
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentNew
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillageBadla
Taluka26
Architect Details
Architect NameANUP KUMAR SINHA
License No.LNP/ARC/0001/2018
Architect Address3rd Floor, Roshpa Tower, Main Road, Ranchi
Architect EmailIDtheaksassociates@gmail.com
Architect Mobile No8986652248
Plot Details
Plot Use Residential
Plot SubUse MultiDwelling Units
PlotNearbyReligiousStructure NA
Plot/SubPlot No3569
NorthPlot No. - 3569
SouthPlot No. - 3570
EastPlot No. - 3615
WestRoad Width - 50
Owner's Details
NameMOUSMI PAUL
AddressC/O, SANTOSH KUMAR ASHOK NAGAR, NEAR BANK OF BARODA, THAKURAIN TALAB, LOHARDAGA.
Email IDsantosh1396@gmail.com
Mobile No6392055279
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 344.00
2 Plot area as per Document by Applicant 344.00
3 Physical area measured at site 344.00
4 Area as per Site Visit (Site Visit Report) 344.00
5Area as per Drawing 351.17

Area of Plot Considered : 344.00

Plot area provided in drawing shall not be more than Plot area as per Document.
[-] Table 2b
Proposal Detail :
UnitMeters
Development Detail :
PlotPLOT
Plot OccupancyResidential
Plot SubUse MultiDwelling Units
Building StructureNon-Highrise
Building TypeSingle Detached House
Gross Plot Area 344.00
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 344.00
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 299.76
Deductions for Balance Plot Area (from Gross Plot Area)
- Common Plot 44.24
44.24
Balance Plot Area 299.76

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 60.00 % ) 206.40
Proposed Coverage Area ( 25.77 % ) 88.64
Total Prop. Coverage Area ( 25.77 % ) 88.64
Balance coverage area ( 34.23 % ) 117.76
FAR CHECK
Perm. FAR Area ( 2.00 ) 688.00
Total Perm. FAR area 688.00
Residential FAR 265.93
Proposed FAR Area 265.93
Total Proposed FAR Area 265.93
Consumed FAR (Factor) 0.77
Balance FAR Area 422.07
BUA CHECK
Total Proposed BuiltUp Area 265.92


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Exceeding 1000 meter -
Existing Road Width 15.24 15.24
Proposed Road Width as per Master Plan 15.24 -
Road Widening Width 0 -
Plot size (as per measurement) 344 351.17
[-] Extra Land Area Checks
Name Area Status
Reqd Prop
Extra Land - 0.00 OK


[-] Plot Level Checking (Table 3)
   
[-] Common Plot Checks (Table 3b)
Name Total Area Status
Reqd Prop
Common Plot 34.40 44.24 OK


[-] Common Plot Checks (Table 3b)
Name Minimum Area Access Status
Reqd Prop
Normal Open Space - 20.23 No Access Provided OK
Normal Open Space - 24.00 No Access Provided OK


   
   
[-] Tree Details (Table 3g)
Name Nos Of Trees Status
Reqd Prop
Tree 4 6 OK
   
   
   
   
   


[-] Building Details (Table 4)
   
[-] Building USE/SUBUSE Details Building USE/SUBUSE Details
Building Name Building Use Building SubUse Building Structure
A (RESIDENTIAL G2) Residential Other Residential Building Non-Highrise
   
   
   
[-] Height Details (4a)



[-] Total Height (Table 4a-1)
Building Height Height (From GL) Height (From Street LVL) Status
Perm Prop
A (RESIDENTIAL G2) 30.00 9.00 9.00 9.00 OK


   
   
[-] Floor Height Check (Table 4a-2)
Building Name Floor Name Height Clear Height Beam Clear Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
A (RESIDENTIAL G2) Second Floor 2.75 - 3.00 2.75 - 2.90 2.40 - 2.65 OK
First Floor 2.75 - 3.00 2.75 - 2.90 2.40 - 2.65 OK
Ground Floor 2.75 - 3.00 2.75 - 2.90 2.40 - 2.65 OK
Plinth 0.45 - 0.60 - - 0.60 - - 0.60 OK


[-] Parapet Height Check (Table 4a-2.1)
Building Name Floor Name Height Status
Reqd Perm Prop
A (RESIDENTIAL G2) Terrace Floor - - 1.00 OK
   
   
   
[-] Floor Number Check (Table 4a-4)
Building Name No. of Floors No. of Tenements Status
Perm Prop Perm Prop
A (RESIDENTIAL G2) - 3 - 1 OK

 
   
    [-] Coverage Check (Table 4b)
Permissible Proposed Status
206.40 88.64 OK
60% 25.77%

[-] Individual Coverage Check
Coverage Area Perm. Prop.
  A-1 (RESIDENTIAL G2) - 88.64
  Total Prop. Coverage Area - 88.64
  Total Coverage Area 206.40 88.64

[-] FAR & Tenement Details (Table 4c-1)
Building No. of Same Bldg Total Built Up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
Resi.
A (RESIDENTIAL G2) 1 265.92 265.92 265.92 265.92 01
Grand Total : 1 265.92 265.92 265.92 265.92 01


[-] Buildingwise Floor FAR Details
Floor Name Building Name Total
A (RESIDENTIAL G2)
Proposed Built Up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Total Proposed Built Up Area (Sq.mt.) Total FAR Area (Sq.mt.)
Ground Floor 88.64 88.64 88.64 88.64
First Floor 88.64 88.64 88.64 88.64
Second Floor 88.64 88.64 88.64 88.64
Terrace Floor 0.00 0.00 0.00 0.00
Total : 265.92 265.92 265.92 265.92


[-] UnitBUA Table for Building :A (RESIDENTIAL G2)
UnitBUA CALCULATION
FLOOR Name UnitBUA Type UnitBUA Area Carpet Area No. of Rooms No. of Tenement
GROUND FLOOR PLAN SPLIT 1 FLAT 265.93 220.39 9 1
TYPICAL - 1& 2 FLOOR PLAN SPLIT 1 FLAT 0.00 0.00 9 0
Total: - - 265.93 220.39 27 1


[-] Building :A (RESIDENTIAL G2)
Floor Name Total Built Up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
Resi.
Ground Floor 88.64 88.64 88.64 88.64 01
First Floor 88.64 88.64 88.64 88.64 00
Second Floor 88.64 88.64 88.64 88.64 00
Terrace Floor 0.00 0.00 0.00 0.00 00
Total : 265.92 265.92 265.92 265.92 01
Total Number of Same Buildings : 1
Total : 265.92 265.92 265.92 265.92 01
[-] Table 4c-2

  FAR Area
Building FAR Area:265.93
Existing FAR Area :0.00
Perm.
688.00
Prop.
265.93
Status
OK




[-] Margin Checks (Table 5)
   
[-] Plot Margin (Table 5a)
Building / Wing Road Name Front Side Rear Side Side1 Side2 Status
Reqd. Prop. Reqd. Prop. Reqd. Prop. Reqd. Prop.
A-1 (RESIDENTIAL G2) 15.24 M WIDE ROAD 4.00 8.59 4.00 43.41 1.00 0.00 1.00 1.00 Failed






[-] Inner Building Details (Table 6)
   

No OTS/Duct/VShaft/Balcony/Passage/Lift/Tenements Found.
   


[-] Parking Details (Table 7)
   

NO PARKING CHECK REQUIRED FOR SINGLE DWELLING UNIT. Other Residential Building, In Building: A (RESIDENTIAL G2)
   


[-] Exemption Details (Table 8)
   


Not Required to Check StairCase Number Rule.


[-] Staircase Checks (Table 8a-1)


[-] For Building :A (RESIDENTIAL G2)
Floor Name StairCase Name Flight Width Tread Width Riser Height Riser No. On Flight Cabin Ht. Status
Reqd Prop Reqd Prop Perm Prop Perm Prop Reqd Perm Prop
GROUND FLOOR PLAN Staircase -3FL 0.900 0.914 0.250 0.250 0.200 0.097 - 9 - - 0.000 OK
TYPICAL - 1& 2 FLOOR PLAN Staircase -3FL 0.900 0.914 0.250 0.250 0.200 0.097 - 9 - - 0.000 OK
TERRACE FLOOR PLAN HEADROOM - 0.914 - 0.250 - 0.000 - 0 - - 2.400 OK

   
   
   
[-] Accessory Use Check (Table 8d)
Accessory Use Name Area Width Depth Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
SEPTIC TANK - - 1.04 - - 0.67 - - 1.61 - - 0.00 OK
RAIN WATER HARVESTING - - 0.61 - - 0.70 - - 0.88 - - 0.00 OK
ENT.GATE - - 0.26 - - 0.16 - - 1.67 - - 0.00 OK
SOLAR HEATING SYSTEM - - 1.78 - - 1.29 - - 1.39 - - 0.00 OK





[-] Accessory Use No. Checks
Building Name Accessory Use Name No Status
Reqd Perm Prop
A (RESIDENTIAL G2) Rain Water Harvesting 1 - 1 OK
   
   


[-] Floor Details (Table 9)
   

[-] Building:A (RESIDENTIAL G2)


[-] Floor:GROUND FLOOR PLAN



All Dimensions and Area of all the Rooms on this Floor are as per the Rules.

[-] Floor:TYPICAL - 1& 2 FLOOR PLAN



All Dimensions and Area of all the Rooms on this Floor are as per the Rules.


   


[-] Summary (Table 10)
   
Name Perm./Reqd. Proposed Status
  Plot Area - 344.00 OK
  Plot Width - 4.57 OK
  Plot Depth - 76.81 OK
  Access Width - 15.24 OK
  Plot Frontage - 4.57 OK
  Coverage Area 206.40 88.64 OK
  FAR Area
Bldg. FAR Area : 265.93
Sanctioned FAR Area :0.00
688.00 265.93 OK





[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Width No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Depth No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Access Width The minimum width of abutting road for any Building shall be with respect to Length of Road {As per Rule No. 34 Table No.6}
Plot Frontage No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
FAR Area (1) In Old Area, for Residential Building on abutting roadwidth 12.20 (40 ft.) to 18.30 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15}
(2) For Lohardaga Nagar Parishad Max. 2.0 permissible FAR may be permitted for Residential Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Residential Building on abutting roadwidth 12.20 (40 ft.) to 18.30 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15}
(2) For Lohardaga Nagar Parishad Max. 2.0 permissible FAR may be permitted for Residential Use {As per Annexure III}
Common Plot Area In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
Common Plot (1) ;
(2) ;
(3) ; ;
Tree Number 4-8 Trees shall be required for the Plot area above 250.0 and upto 1000.0 sq.mt. (As per Rule No. 20.1.6)
Margin Rule For narrow plots,the setbacks on sides may be compensated in front and rear setbacks so as to ensure that the overall aggregate setbacks are maintained in the site, subject to maintaining a minimum of side setback of 1m in case of buildings of height up to 10.0 mt.
Building Level
Building Height For old area, on Road width 12.20-18.30 mt., Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 30.0 mt. {As per Rule No. 39.1 Table 15}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(3) The plinth or any part of a building shall be so located with respect to the surrounding ground level that adequate drainage of the site is assured. The height of the plinth (except in case of stilted parking) shall be not less than 0.45 mt. from the surrounding ground level {As per Rule No. 42.10}
Parapet Height Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
Floor Number For old area location,on Road width 12.20-18.30 mt., Maximum Height 30 meter shall be allowed. {As per Rule No. 39.1 Table 15}
StairCase (1) Width of Winding staircase shall be mini. 0.90 mt.,Maximum rise 0.20 mt. & Minimum tread 0.25 mt. & Cabin Height 2.1 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) No Rule Defined
(4) ; No Rule Defined
Plot / Building Level
Accessory Use (1) -
(2) No need to check distance from Building SEPTIC TANK
(3) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(4) No need to check distance from Building RAIN WATER HARVESTING
(5) No need to check distance from Building ENT.GATE
(6) -
(7) No need to check distance from Building SOLAR HEATING SYSTEM
Accessory Use Number Provision of Rain Water Harvesting shall be mandatory for any use {Updated as per JBBL, Amendment VIII dated 16/03/2021} Rain Water Harvesting
Building Level (Rooms)