Check List Report

Lohardaga Nagar Parishad

Version Number: 1.0.64  
Version Date: 16/10/2020 
Report Generated On: 24-12-2022 
 

[-] Collapse All


General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictLOHARDAGA
AuthorityLOHARDAGA NAGAR PARISHAD
Inward_NoLNP/BP/0060/W14/2022
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentAddition or Alteration
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillageLohardaga
Taluka26
Layout Sanction No70/2014
Layout Sanction Date27/1/2015
Architect Details
Architect NameAtaul Haque
License No.LNP/ENG/0001/2021
Architect AddressAzad basti bangla
Architect EmailIDmdataul.haque265@gmail.com
Architect Mobile No9304264642
Plot Details
Plot Use Residential
Plot SubUse Residential Bldg/Apartment
PlotNearbyReligiousStructure NA
Plot/SubPlot No538/772
North -
South -
East -
West -
Owner's Details
NameRAVINDRA KUMAR KHATRI AND KAVI KUMAR KHATRI
AddressSARNA TOLI,LOHARDAGA
Email IDravi.khatri08@gmail.com
Mobile No8789644112
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 879.07
2 Plot area as per Document by Applicant 879.07
3 Area as per Site Visit (Site Visit Report) 879.07
4Area as per Drawing 879.07

Area of Plot Considered : 879.07

[-] Table 2b
Proposal Detail :
Unit
Development Detail :
PlotPLOT
Plot OccupancyResidential
Plot SubUse Residential Bldg/Apartment
Building StructureNon-Highrise
Building TypeSingle Detached House
Gross Plot Area 879.07
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 879.07
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 759.81
Deductions for Balance Plot Area (from Gross Plot Area)
- Common Plot 119.26
119.26
Balance Plot Area 759.81

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 60.00 % ) 527.44
Proposed Coverage Area ( 16.92 % ) 148.73
Total Prop. Coverage Area ( 16.92 % ) 148.73
Balance coverage area ( 43.08 % ) 378.71
FAR CHECK
Perm. FAR Area ( 2.000 ) 1758.14
Total Perm. FAR area 1758.14
Residential FAR 741.06
Proposed FAR Area 751.55
Total Proposed FAR Area 751.55
Consumed FAR (Factor) 0.85
Balance FAR Area 1006.59
BUA CHECK
Total Proposed BuiltUp Area 950.39


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Exceeding 100 meter and upto 250 meter -
Existing Road Width 6.1 6.10
Proposed Road Width as per Master Plan 6.1 -
Road Widening Width 0 -
Plot size (as per measurement) 879.07 879.07
[-] Extra Land Area Checks
Name Area Status
Reqd Prop
Extra Land - 0.00 OK

     Extra Land Area Details
Name Description Unit Reqd Perm Proposed Status
Extra Land Area Details Extra Land Area - - 0.00 OK

     Plot Related Details
Name Description Unit Reqd Perm Proposed Status
PLOT Plot Area Sq.Mt. - - 879.07 OK
Plot Width Mt. - - 27.98 OK
Plot Depth Mt. - - 31.42 OK
Access Width Mt. 6.10 - 6.10 OK
Plot Frontage Mt. - - 30.84 OK
Coverage Area Sq.Mt. - 527.44 148.73 OK
FAR Area Sq.Mt. - 1758.14 751.55 OK
Consumed FAR Sq.Mt. - 2.00 0.85 OK
Common Plot Checks Common Plot - Total Area Sq.Mt. 87.91 119.26 OK
Common Plot Tree Cover (Plantation) - Minimum Area Sq.Mt. - 119.26 OK
Tree Cover (Plantation) - Coverage Area Sq.Mt. - - OK
Tree Cover (Plantation) - Width Mt. - 6.61 OK
Tree Cover (Plantation) - Angle Degree - 86.95 OK
Tree Cover (Plantation) - Access Mt. - OK
Tree Tree - Nos Of Trees No. 4 5 OK
Car In Area Sq.Mt. - - 62.50 OK
Total Car In Area Sq.Mt. 62.50 - 62.50 OK
Visitor's Car Parking In Area Sq.Mt. - - 12.50 OK
Total Visitor Parking In Area Sq.Mt. 12.50 - 12.50 OK
TwoWheeler In Area Sq.Mt. - - 10.00 OK
Total TwoWheeler In Area Sq.Mt. 10.00 - 10.00 OK
Other Parking In Area Sq.Mt. - - 102.65 OK
DriveWay 123 (ABC) - BASEMENT FLOOR PLAN - DRIVEWAY CP - Width No. 3.60 - 3.60 OK
123 (ABC) - BASEMENT FLOOR PLAN - DRIVEWAY TW - Width No. 3.00 - 3.00 OK
123-1 (ABC) Front Margin... 6.1 METER WIDE MAIN ROAD Mt. 4.00 - 5.92 OK
Rear Margin Mt. 3.50 - 5.33 OK
Side1 Margin Mt. 3.00 - 3.74 OK
Side2 Margin Mt. 3.00 - 15.02 OK
123-1 (ABC) Basement Front Margin... 6.1 METER WIDE MAIN ROAD Mt. 2.00 - 2.64 OK
Basement Rear Margin Mt. 2.00 - 5.11 OK
Basement Side1 Margin Mt. 2.00 - 3.74 OK
Basement Side2 Margin Mt. 2.00 - 15.02 OK

     Building Related Details
Name Description Unit Reqd Perm Proposed Status
123 (ABC) Height Mt. 15.07 14.50 OK
123 (ABC) Fourth Floor - Height Mt. 2.75 - 2.90 OK
Fourth Floor - Clear Height Mt. 2.75 - 2.80 OK
Fourth Floor - Beam Clear Height Mt. 2.40 - 2.65 OK
Third Floor - Height Mt. 2.75 - 2.90 OK
Third Floor - Clear Height Mt. 2.75 - 2.80 OK
Third Floor - Beam Clear Height Mt. 2.40 - 2.65 OK
Second Floor - Height Mt. 2.75 - 2.90 OK
Second Floor - Clear Height Mt. 2.75 - 2.80 OK
Second Floor - Beam Clear Height Mt. 2.40 - 2.65 OK
First Floor - Height Mt. 2.75 - 2.90 OK
First Floor - Clear Height Mt. 2.75 - 2.80 OK
First Floor - Beam Clear Height Mt. 2.40 - 2.65 OK
Ground Floor - Height Mt. 2.75 - 2.90 OK
Ground Floor - Clear Height Mt. 2.75 - 2.80 OK
Ground Floor - Beam Clear Height Mt. 2.40 - 2.65 OK
Basement Floor - Height Mt. 2.40 - 2.85 OK
Basement Floor - Clear Height Mt. 2.40 - 2.75 OK
Basement Floor - Beam Clear Height Mt. 2.10 - 2.60 OK
123 (ABC) Terrace Floor - Height Mt. - - 0.90 OK
Terrace Floor - Clear Height Mt. - - 0.90 OK
Terrace Floor - Beam Clear Height Mt. - - 0.90 OK
123 (ABC) Basement Floor - Height of Basement Floor above GL Mt. 0.90 1.50 0.90 OK
Basement Floor - Area Sq.Mt. - 179.58 OK
Basement Floor - Ventilation Area Sq.Mt. - - OK
123 (ABC) Area Sq.Mt. - 179.58 OK
Status - OK
Total Area Sq.Mt. - 179.58 OK
123 (ABC) No. of Basement Floor No. 2 1 OK
123 (ABC) No. of Floors No. G + 4 5 OK
No. of Tenements No. - 5 OK
123 (ABC) THIRD FLOOR PLAN - BALCONY - Width Mt. 1.20 1.05 OK
THIRD FLOOR PLAN - BALCONY - Width Mt. 1.20 0.90 OK
THIRD FLOOR PLAN - BALCONY - Width Mt. 1.20 0.90 OK
FOURTH FLOOR PLAN - BALCONY - Width Mt. 1.20 0.90 OK
FOURTH FLOOR PLAN - BALCONY - Width Mt. 1.20 1.05 OK
FOURTH FLOOR PLAN - BALCONY - Width Mt. 1.20 0.90 OK
TYPICAL - 1& 2 FLOOR PLAN - BALCONY - Width Mt. 1.20 0.90 OK
TYPICAL - 1& 2 FLOOR PLAN - BALCONY - Width Mt. 1.20 0.90 OK
123 (ABC) Number Of Lift(s) No. - 1 OK
Number Of Strature Lift(s) No. - - OK
Capacity Of Lift(s) Passanger No. - 6 OK
123 (ABC) THIRD FLOOR PLAN - Lift - Width Mt. 1.70 1.70 OK
THIRD FLOOR PLAN - Lift - Depth Mt. 1.90 2.08 OK
FOURTH FLOOR PLAN - Lift - Width Mt. 1.70 1.70 OK
FOURTH FLOOR PLAN - Lift - Depth Mt. 1.90 2.08 OK
TERRACE FLOOR PLAN - Lift Machine Room - Width Mt. 1.70 1.70 OK
TERRACE FLOOR PLAN - Lift Machine Room - Depth Mt. 1.90 2.08 OK
BASEMENT FLOOR PLAN - Lift - Width Mt. 1.70 1.70 OK
BASEMENT FLOOR PLAN - Lift - Depth Mt. 1.90 2.08 OK
THIRD FLOOR PLAN STAIRCASE - Flight Width Mt. 0.900 1.050 OK
STAIRCASE - Tread Width Mt. 0.250 0.250 OK
STAIRCASE - Riser Height Mt. 0.200 0.161 OK
STAIRCASE - Riser No. On Flight No. - 9 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
FOURTH FLOOR PLAN STAIRCASE - Flight Width Mt. 0.900 1.050 OK
STAIRCASE - Tread Width Mt. 0.250 0.250 OK
STAIRCASE - Riser Height Mt. 0.200 0.161 OK
STAIRCASE - Riser No. On Flight No. - 9 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
TERRACE FLOOR PLAN STAIRCASE - Flight Width Mt. - 1.050 OK
STAIRCASE - Tread Width Mt. - 0.250 OK
STAIRCASE - Riser Height Mt. - - OK
STAIRCASE - Riser No. On Flight No. - - OK
STAIRCASE - Cabin Ht. Mt. - - 2.450 OK
BASEMENT FLOOR PLAN STAIRCASE - Flight Width Mt. 0.900 1.050 OK
STAIRCASE - Tread Width Mt. 0.250 0.250 OK
STAIRCASE - Riser Height Mt. 0.200 - OK
STAIRCASE - Riser No. On Flight No. - - OK
STAIRCASE - Cabin Ht. Mt. - - - OK
Toilet Area Sq.Mt. - 5.00 3.06 OK
Width Mt. - - 1.22 OK
Depth Mt. - - 2.65 OK
Height Mt. - - - OK
RWH Area Sq.Mt. - - 1.61 OK
Width Mt. - - 1.43 OK
Depth Mt. - - 1.44 OK
Height Mt. - - - OK
ENT.GATE Area Sq.Mt. - - 0.45 OK
Width Mt. - - 0.13 OK
Depth Mt. - - 3.60 OK
Height Mt. - - - OK
123 (ABC) Rain Water Harvesting - No No. 1 - 1 OK
Entrance Gate - No No. 1 - 1 OK
Ramp No. 123 (ABC) - BASEMENT FLOOR PLAN - No. No. 1 1 OK
   
    All Rooms are as per Rule in Room Checking




[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Width No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Depth No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Access Width The minimum width of abutting road for any Building more than 13.3 mt. ht. shall be 6.1 mt.{As per Rule no. 35.1 Note 4}
Plot Frontage No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
FAR Area (1) In Old Area, for Residential Building on abutting roadwidth 6.10 (20 ft.) to 7.5 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15 and modified as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
(2) For Lohardaga Nagar Parishad Max. 2.0 permissible FAR may be permitted for Residential Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Residential Building on abutting roadwidth 6.10 (20 ft.) to 7.5 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15 and modified as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
(2) For Lohardaga Nagar Parishad Max. 2.0 permissible FAR may be permitted for Residential Use {As per Annexure III}
Common Plot Area In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
Common Plot (1) In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
(2) ;
Tree Number 4-8 Trees shall be required for the Plot area above 250.0 and upto 1000.0 sq.mt. (As per Rule No. 20.1.6)
DriveWay Rule (1) For Plor area upto 2000 sq.mt., the minimum width or driveways should not be less than 3.60 mt. {As per Rule No. 41.2 and modified as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
(2) The minimum width of the drive way meant exclusively for 2 wheelers should be 3.0 mt {As per Rule No. 41.2}
Margin Rule For Non-highrise Residential Building 13.3-16.4 mt. Ht. having Plot Depth 27-33 mt. and Plot width 27-33 mt., Margin required in Front shall be 4.0 mt., Rear 3.5 mt. and 3.0 mt. shall be provided on both side. {As per Rule No. 36 (Table 8 & 9)}
Basement Margin Rule In case of apartment/ group housing/commercial building and basements may be allowed to be constructed under the entire plot area leaving mini. 2 mt. space from the boundary of the premises {As per Rule No. 48}
Building Level
Building Height For old area, on Road width 6.10-7.50 mt., Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 16.4 mt. {As per Rule No. 39.1 Table 15}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(3) o Every basement shall be in every part at least 2.4 m. in height from the floor to the soffit of the roof slab or ceiling and mini. Of 2.1 mr. below the soffit of beams {As per Rule No. 48}
Parapet Height (1) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
(2) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
(3) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
Below GL Floor Height The minimum height of the ceiling of upper basement shall be 0.90m. and the maximum, 1.5 m. above the average surrounding ground level {As per Rule No. 48},
Basement Floor No. Maximum two basements/cellars may be permitted to be constructed for the plot size above 750 sq.mt. leaving the prescribed set back/open space applicable to the building {As per Rule No. 48}
Floor Number For old area location,on Road width 6.1-7.5 mt. only G+4 floors shall be allowed {As per Rule No. 39.1 Table 15}
Balcony Projected balcony may be allowed with a widt of 1.2 mt. where the setback is more than 2.5 mt. {As per Rule No. 46.4 and modified as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
Lift Count (1) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(2) For Residential Building height upto 15.0 mt or upto G+4 floors, No Lift is reqd. {As per Amended 06-06-2019 Rule No. 49.1.1}
Lift (1) The area of lift well shall not be counted for F.A.R calculation)
(2) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(3) -
StairCase (1) Width of Winding staircase shall be mini. 0.90 mt.,Maximum rise 0.20 mt. & Minimum tread 0.25 mt. & Cabin Height 2.1 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) No Rule Defined
(4) ; No Rule Defined
Ramp No. For parking spaces in basements and upper storey of parking floors, if car parking is less then 40 one ramp of minimum of 3.30m width if it is straight and 4.50m width if it is curved shall be provided
Plot / Building Level
Accessory Use (1) Common toilet of maximum size of 5 sq.mt shall be taken Free from FAR
(2) No need to check distance from Building Toilet
(3) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(4) No need to check distance from Building RWH
(5) No need to check distance from Building ENT.GATE
Accessory Use Number (1) Provision of Rain Water Harvesting shall be mandatory for any use {Updated as per JBBL, Amendment VIII dated 16/03/2021} Rain Water Harvesting
(2) In case of buildings with a height of 15.0 meters and above or ground coverage more than 500 sqm., the main entrance to the premise shall not be less than 5 (five) meters i n width in order to allow easy access to fire engine Entrance Gate
Building Level (Rooms)