No Image Found   

Check List Report

Lohardaga Nagar Parishad

Version Number: 1.0.65  
Version Date: 16/10/2020 
Report Generated On: 24-01-2023 
 

[-] Collapse All


General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictLOHARDAGA
AuthorityLOHARDAGA NAGAR PARISHAD
Inward_NoLNP/BP/0065/W16/2022
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentNew
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillageLohardaga
Taluka26
Architect Details
Architect NameASHWINI KUMAR SAHU
License No.LNP/ENG/0005/2017
Architect AddressNear check post, PWD Road
Architect EmailIDerashwinisahu@gmail.com
Architect Mobile No9308730823
Plot Details
Plot Use Residential
Plot SubUse Bungalow/ Dwelling / Non Apartment
PlotNearbyReligiousStructure NA
Plot/SubPlot No2695
NorthPlot No. - 2696
SouthPlot No. - 2694
EastRoad Width - 3
WestRoad Width - 4.5
Owner's Details
NameRAM KEWAL SONI
AddressMAIN ROAD UPPER BAZAR LOHARDAGA
Email IDSOALOHARDAGA@GMAIL.COM
Mobile No6207615651
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Plot area as per Document by Applicant 186.56
2 Physical area measured at site 186.56
3 Area as per Site Visit (Site Visit Report) 186.56
4Area as per Drawing 186.50

Area of Plot Considered : 186.50

[-] Table 2b
Proposal Detail :
Unit
Development Detail :
PlotPLOT
Plot OccupancyResidential
Plot SubUse Bungalow/ Dwelling / Non Apartment
Building StructureNon-Highrise
Building TypeSingle Detached House
Gross Plot Area 186.50
Deduction from Gross Plot area
- Surrender Free of Cost 9.92
9.92
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 176.58
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 156.77
Deductions for Balance Plot Area (from Gross Plot Area)
- Surrender Free of Cost 9.92
- Common Plot 19.81
29.73
Balance Plot Area 156.77

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 70.00 % ) 123.61
Proposed Coverage Area ( 47.85 % ) 84.49
Total Prop. Coverage Area ( 47.85 % ) 84.49
Balance coverage area ( 22.15 % ) 39.12
FAR CHECK
Perm. FAR Area ( 1.500 ) 279.75
Total Perm. FAR area 279.75
Residential FAR 169.03
Commercial FAR 84.49
Proposed FAR Area 253.52
Total Proposed FAR Area 253.52
Consumed FAR (Factor) 1.36
Balance FAR Area 26.23
BUA CHECK
Total Proposed BuiltUp Area 352.46


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Exceeding 1000 meter -
Existing Road Width 4.5 4.50
Proposed Road Width as per Master Plan 4.5 -
Road Widening Width 0 1.55
Plot size (as per measurement) 186.56 186.50

     Plot Related Details
Name Description Unit Reqd Perm Proposed Status
PLOT Plot Area Sq.Mt. - - 176.58 OK
Plot Width Mt. - - 7.25 OK
Plot Depth Mt. - - 24.37 OK
Access Width Mt. - - 4.50 OK
Plot Frontage Mt. - - 6.40 OK
Coverage Area Sq.Mt. - 123.61 84.49 OK
FAR Area Sq.Mt. - 279.75 253.52 OK
Consumed FAR Sq.Mt. - 1.50 1.36 OK
Common Plot Checks Common Plot - Total Area Sq.Mt. 8.83 19.81 OK
Common Plot Tree Cover (Plantation) - Minimum Area Sq.Mt. - 19.81 OK
Tree Cover (Plantation) - Coverage Area Sq.Mt. - - OK
Tree Cover (Plantation) - Width Mt. - 1.48 OK
Tree Cover (Plantation) - Angle Degree - 90.00 OK
Tree Cover (Plantation) - Access Mt. - OK
Tree Tree - Nos Of Trees No. 2 5 OK
Car In Area Sq.Mt. - - 25.00 OK
Two Stack.Car In Area Sq.Mt. - - 25.00 OK
Total Car In Area Sq.Mt. 37.50 - 77.00 OK
Parallel Car In Area Sq.Mt. - - 27.00 OK
Total Visitor Parking In Area Sq.Mt. 12.50 - 13.50 OK
Parallel Visitor's Car Parking In Area Sq.Mt. - - 13.50 OK
TwoWheeler In Area Sq.Mt. - - 18.00 OK
Total TwoWheeler In Area Sq.Mt. 6.00 - 18.00 OK
ERiksha Stand Area In Area Sq.Mt. - - 27.00 OK
Other Parking In Area Sq.Mt. - - 64.53 OK
DriveWay PLOT - - - DRIVEWAY - Width No. 3.00 - 3.70 OK
A (RAM KEWAL SONI) - BASEMENT FLOOR PLAN - DRIVEWAY - Width No. 3.60 - 3.69 OK
A-1 (RAM KEWAL SONI) Front Margin... ROAD WIDENING AREA(SURRENDERED FREE OF COST) Mt. 3.00 - 5.55 OK
Rear Margin Mt. 1.80 - 4.01 OK
Side1 Margin Mt. 0.90 - 1.51 OK
Side2 Margin Mt. - - 0.01 OK
A-1 (RAM KEWAL SONI) BldgLine for 4.5 MTR WIDE ROAD Access Road Mt. 1.50 7.10 OK
A-1 (RAM KEWAL SONI) ResvRoad Width Check for... 4.5 MTR WIDE ROAD Access Road Mt. 1.50 1.55 OK
A-1 (RAM KEWAL SONI) Basement Front Margin... ROAD WIDENING AREA(SURRENDERED FREE OF COST) Mt. 3.00 - 4.55 OK
Basement Rear Margin Mt. 1.80 - 4.01 OK
Basement Side1 Margin Mt. 0.90 - 1.51 OK
Basement Side2 Margin Mt. - - 0.01 OK

     Building Related Details
Name Description Unit Reqd Perm Proposed Status
A (RAM KEWAL SONI) Height Mt. 10.00 9.14 OK
A (RAM KEWAL SONI) Second Floor - Height Mt. 2.75 - 3.05 OK
Second Floor - Clear Height Mt. 2.75 - 2.98 OK
Second Floor - Beam Clear Height Mt. 2.40 - 2.76 OK
First Floor - Height Mt. 2.75 - 3.05 OK
First Floor - Clear Height Mt. 2.75 - 2.98 OK
First Floor - Beam Clear Height Mt. 2.40 - 2.76 OK
Ground Floor - Height Mt. 2.75 - 3.05 OK
Ground Floor - Clear Height Mt. 2.75 - 2.98 OK
Ground Floor - Beam Clear Height Mt. 2.40 - 2.76 OK
Basement Floor - Height Mt. 2.40 - 3.05 OK
Basement Floor - Clear Height Mt. 2.40 - 2.98 OK
Basement Floor - Beam Clear Height Mt. 2.10 - 2.76 OK
A (RAM KEWAL SONI) Terrace Floor - Height Mt. - - 1.04 OK
Terrace Floor - Clear Height Mt. - - 1.04 OK
Terrace Floor - Beam Clear Height Mt. - - 1.04 OK
A (RAM KEWAL SONI) Basement Floor - Height of Basement Floor above GL Mt. 0.90 1.50 1.00 OK
Basement Floor - Area Sq.Mt. - 91.53 OK
Basement Floor - Ventilation Area Sq.Mt. - - OK
A (RAM KEWAL SONI) Area Sq.Mt. - 91.53 OK
Status - OK
Total Area Sq.Mt. - 91.53 OK
A (RAM KEWAL SONI) No. of Basement Floor No. 1 1 OK
A (RAM KEWAL SONI) No. of Floors No. G + 2 3 OK
No. of Tenements No. - 4 OK
A (RAM KEWAL SONI) Number Of Lift(s) No. - 1 OK
Number Of Strature Lift(s) No. - - OK
Capacity Of Lift(s) Passanger No. - 6 OK
A (RAM KEWAL SONI) GROUND FLOOR PLAN - Lift - Width Mt. 1.70 1.78 OK
GROUND FLOOR PLAN - Lift - Depth Mt. 1.90 2.08 OK
FIRST FLOOR PLAN - Lift - Width Mt. 1.70 1.78 OK
FIRST FLOOR PLAN - Lift - Depth Mt. 1.90 2.08 OK
SECOND FLOOR PLAN - Lift - Width Mt. 1.70 1.78 OK
SECOND FLOOR PLAN - Lift - Depth Mt. 1.90 2.08 OK
TERRACE FLOOR PLAN - Lift Machine Room - Width Mt. 1.70 1.78 OK
TERRACE FLOOR PLAN - Lift Machine Room - Depth Mt. 1.90 2.08 OK
GROUND FLOOR PLAN Staircase -3FL - Flight Width Mt. 0.900 0.914 OK
Staircase -3FL - Tread Width Mt. 0.250 0.254 OK
Staircase -3FL - Riser Height Mt. 0.200 0.076 OK
Staircase -3FL - Riser No. On Flight No. - 9 OK
Staircase -3FL - Cabin Ht. Mt. - - - OK
FIRST FLOOR PLAN Staircase -3FL - Flight Width Mt. 0.900 0.914 OK
Staircase -3FL - Tread Width Mt. 0.250 0.254 OK
Staircase -3FL - Riser Height Mt. 0.200 0.076 OK
Staircase -3FL - Riser No. On Flight No. - 9 OK
Staircase -3FL - Cabin Ht. Mt. - - - OK
SECOND FLOOR PLAN Staircase -3FL - Flight Width Mt. 0.900 0.914 OK
Staircase -3FL - Tread Width Mt. 0.250 0.254 OK
Staircase -3FL - Riser Height Mt. 0.200 0.076 OK
Staircase -3FL - Riser No. On Flight No. - 9 OK
Staircase -3FL - Cabin Ht. Mt. - - - OK
TERRACE FLOOR PLAN Staircase -3FL - Flight Width Mt. - 0.914 OK
Staircase -3FL - Tread Width Mt. - 0.254 OK
Staircase -3FL - Riser Height Mt. - - OK
Staircase -3FL - Riser No. On Flight No. - - OK
Staircase -3FL - Cabin Ht. Mt. - - 2.591 OK
Sewage Treatment Plant Area Sq.Mt. - - 0.94 OK
Width Mt. - - 0.77 OK
Depth Mt. - - 1.22 OK
Height Mt. - - - OK
RAIN WATER HARVESTING Area Sq.Mt. - - 0.86 OK
Width Mt. - - 0.84 OK
Depth Mt. - - 1.03 OK
Height Mt. - - - OK
ENT.GATE Area Sq.Mt. - - 0.29 OK
Width Mt. - - 0.27 OK
Depth Mt. - - 1.11 OK
Height Mt. - - - OK
SOLAR HEATING SYSTEM Area Sq.Mt. - - 1.24 OK
Width Mt. - - 1.01 OK
Depth Mt. - - 1.23 OK
Height Mt. - - - OK
A (RAM KEWAL SONI) Rain Water Harvesting - No No. 1 - 1 OK
PLOT 1.00 mt. long 1.50 mt. High 3.69 mt. Wide Natural Slope - Width Mt. - 1.00 OK
1.00 mt. long 1.50 mt. High 3.69 mt. Wide Natural Slope - Depth Mt. - 1.50 OK
1.00 mt. long 1.50 mt. High 3.69 mt. Wide Natural Slope - Slope Ratio - - - OK
Ramp No. A (RAM KEWAL SONI) - BASEMENT FLOOR PLAN - No. No. 1 1 OK
   
    All Rooms are as per Rule in Room Checking




[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Width No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Depth No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Access Width The minimum width of abutting road for any Building shall be with respect to Length of Road {As per Rule No. 34 Table No.6}
Plot Frontage No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
FAR Area (1) In Old Area, for Residential Building on abutting roadwidth 3.60 (12 ft.) to 4.80 mt., the Floor Area Ratio-FAR shall be 1.5 {As per Rule No.39, Table 15}
(2) For Lohardaga Nagar Parishad Max. 2.0 permissible FAR may be permitted for Residential Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Residential Building on abutting roadwidth 3.60 (12 ft.) to 4.80 mt., the Floor Area Ratio-FAR shall be 1.5 {As per Rule No.39, Table 15}
(2) For Lohardaga Nagar Parishad Max. 2.0 permissible FAR may be permitted for Residential Use {As per Annexure III}
Common Plot Area In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
Common Plot (1) In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
(2) ;
Tree Number 2-4 Trees shall be required for the Plot area upto 250.0 sq.mt. (As per Rule No. 20.1.6)
DriveWay Rule (1) The minimum width of the drive way meant exclusively for 2 wheelers should be 3.0 mt {As per Rule No. 41.2}
(2) For Plor area upto 2000 sq.mt., the minimum width or driveways should not be less than 3.60 mt. {As per Rule No. 41.2 and modified as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
Margin Rule For Non-highrise Residential Building upto 10.0 mt. Ht. having Plot Depth 21-27 mt. and Plot width 21-27 mt., Margin required in Front shall be 3.0 mt., Rear 1.8 mt. and Atleast 0.9 mt. shall be provided at one side. {As per Rule No. 36 (Table 8 & 9)}
Building Line Check The min. width of Road for length of Road Exceeding 300 mt. shall be 7.50 mt. {As per Rule No. 34 Table No. 6}
ResvRoad Width Check The min. width of Road for length of Road Exceeding 300 mt. shall be 7.50 mt. {As per Rule No. 34 Table No. 6}
Basement Margin Rule Basements/cellars may be permitted to be constructed leaving the prescribed set back/open space applicable to the building {As per Rule No. 48}
Building Level
Building Height For old area, on Road width 3.6-4.8 mt., Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 10.0 mt. {As per Rule No. 39.1 Table 15}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(3) o Every basement shall be in every part at least 2.4 m. in height from the floor to the soffit of the roof slab or ceiling and mini. Of 2.1 mr. below the soffit of beams {As per Rule No. 48}
Parapet Height (1) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
(2) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
(3) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
Below GL Floor Height The minimum height of the ceiling of upper basement shall be 0.90m. and the maximum, 1.5 m. above the average surrounding ground level {As per Rule No. 48},
Basement Floor No. Individual residential and small commercial buildings, plot size upto minimum 750 Sq. Meter may have one basement {As per Rule No. 48}
Floor Number For old area location,on Road width 3.6-4.8 mt. only G+2 floors shall be allowed {As per Rule No. 39.1 Table 15}
Lift Count (1) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(2) For Residential Building height upto 15.0 mt or upto G+4 floors, No Lift is reqd. {As per Amended 06-06-2019 Rule No. 49.1.1}
Lift (1) The area of lift well at one floor only (not the sum of total area of lift well at every floor) shall be counted for F.A.R calculation)
(2) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(3) The area of lift well shall not be counted for F.A.R calculation)
(4) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(5) -
StairCase (1) Width of Winding staircase shall be mini. 0.90 mt.,Maximum rise 0.20 mt. & Minimum tread 0.25 mt. & Cabin Height 2.1 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) No Rule Defined
(4) ; No Rule Defined
Ramp No Need to Check Natural Slope width, Depth or height. ;
Ramp No. For parking spaces in basements and upper storey of parking floors, if car parking is less then 40 one ramp of minimum of 3.30m width if it is straight and 4.50m width if it is curved shall be provided
Plot / Building Level
Accessory Use (1) -
(2) No need to check distance from Building Sewage Treatment Plant
(3) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(4) No need to check distance from Building RAIN WATER HARVESTING
(5) No need to check distance from Building ENT.GATE
(6) -
(7) No need to check distance from Building SOLAR HEATING SYSTEM
Accessory Use Number Provision of Rain Water Harvesting shall be mandatory for any use {Updated as per JBBL, Amendment VIII dated 16/03/2021} Rain Water Harvesting
Building Level (Rooms)