General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictLOHARDAGA
AuthorityLOHARDAGA NAGAR PARISHAD
Inward_NoLNP/BP/0053/W22/2022
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentNew
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillageLohardaga
Taluka26
Architect Details
Architect NameAshish Deep Toppo
License No.LNP/ARC/0009/2017
Architect AddressS/O Atul Kumar Suman Toppo G. E. L. Mission Compound Anandpur
Architect EmailIDashish.d.toppo@gmail.com
Architect Mobile No7992304518
Plot Details
Plot Use Assembly
Plot SubUse Religious Building
PlotNearbyReligiousStructure NA
Plot/SubPlot No3006
NorthPlot No. - 3005
SouthPlot No. - 3005
EastPlot No. - 3004
WestPlot No. - 3007
Owner's Details
NameSt. Ursula Hospital
AddressCollege Road
Email IDashish.d.toppo@gmail.com
Mobile No7992304518
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 1169.00
2 Plot area as per Document by Applicant 1169.00
3 Physical area measured at site 1160.00
4 Area as per Site Visit (Site Visit Report) 1169.00
5Area as per Drawing 1157.75

Area of Plot Considered : 1157.75

[-] Table 2b
Proposal Detail :
Unit
Development Detail :
PlotPLOT
Plot OccupancyAssembly
Plot SubUse Religious Building
Building StructureNon-Highrise
Building TypeSingle Detached House
Gross Plot Area 1157.75
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 1157.75
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 914.09
Deductions for Balance Plot Area (from Gross Plot Area)
- Common Plot 243.66
243.66
Balance Plot Area 914.09

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 50.00 % ) 578.88
Proposed Coverage Area ( 17.63 % ) 204.11
Total Prop. Coverage Area ( 17.63 % ) 204.11
Balance coverage area ( 32.37 % ) 374.77
FAR CHECK
Perm. FAR Area ( 2.000 ) 2315.50
Total Perm. FAR area 2315.50
Special FAR 444.64
Proposed FAR Area 444.64
Total Proposed FAR Area 444.64
Consumed FAR (Factor) 0.38
Balance FAR Area 1870.86
BUA CHECK
Total Proposed BuiltUp Area 499.62


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Exceeding 50 meter and upto 100 meter -
Existing Road Width 6.05 12.20
Proposed Road Width as per Master Plan 6.05 -
Road Widening Width 0 -
Plot size (as per measurement) 1169 1157.75

[-] Road width Details Checks
No Rule Status
1 For Existing Road Width, value as per site visit and value as per drawing should be same. Failed
[-] Extra Land Area Checks
Name Area Status
Reqd Prop
Extra Land - 0.00 OK

     Extra Land Area Details
Name Description Unit Reqd Perm Proposed Status
Extra Land Area Details Extra Land Area - - 0.00 OK

     Plot Related Details
Name Description Unit Reqd Perm Proposed Status
PLOT Plot Area Sq.Mt. 500.00 - 1157.75 OK
Plot Width Mt. - - 35.10 OK
Plot Depth Mt. - - 32.98 OK
Access Width Mt. 12.20 - 12.20 OK
Plot Frontage Mt. - - 39.67 OK
Coverage Area Sq.Mt. - 578.88 204.11 OK
FAR Area Sq.Mt. - 2315.50 444.64 OK
Consumed FAR Sq.Mt. - 2.00 0.38 OK
Common Plot Checks Common Plot - Total Area Sq.Mt. 115.78 243.66 OK
Common Plot Tree Cover (Plantation) - Minimum Area Sq.Mt. - 109.26 OK
Tree Cover (Plantation) - Coverage Area Sq.Mt. - - OK
Tree Cover (Plantation) - Width Mt. - 3.44 OK
Tree Cover (Plantation) - Angle Degree - 89.89 OK
Tree Cover (Plantation) - Access Mt. - OK
Tree Cover (Plantation) - Minimum Area Sq.Mt. - 134.40 OK
Tree Cover (Plantation) - Coverage Area Sq.Mt. - - OK
Tree Cover (Plantation) - Width Mt. - 4.86 OK
Tree Cover (Plantation) - Angle Degree - 84.82 OK
Tree Cover (Plantation) - Access Mt. - OK
Tree Tree - Nos Of Trees No. 8 8 OK
Car In Area Sq.Mt. - - 12.89 OK
Total Car In Area Sq.Mt. 12.50 - 12.89 OK
ST URSLA HOSPITAL-1 ( RELIGIOUS BUILDING) Front Margin... 12.20MT MAIN ROAD Access Road Mt. - - 5.00 OK
Rear Margin Mt. - - 8.19 OK
Side1 Margin Mt. - - 7.73 OK
Side2 Margin Mt. - - 14.04 OK

     Building Related Details
Name Description Unit Reqd Perm Proposed Status
ST URSLA HOSPITAL ( RELIGIOUS BUILDING) Height Mt. 23.30 4.50 OK
ST URSLA HOSPITAL ( RELIGIOUS BUILDING) Upper Ground Floor - Height Mt. 2.75 - 4.50 OK
Upper Ground Floor - Clear Height Mt. 2.75 - 4.35 OK
Upper Ground Floor - Beam Clear Height Mt. 2.40 - 4.00 OK
Lower Ground Floor - Height Mt. 2.75 - 3.00 OK
Lower Ground Floor - Clear Height Mt. 2.75 - 2.85 OK
Lower Ground Floor - Beam Clear Height Mt. 2.40 - 2.50 OK
ST URSLA HOSPITAL ( RELIGIOUS BUILDING) Terrace Floor - Height Mt. - - 1.00 OK
Terrace Floor - Clear Height Mt. - - 1.00 OK
Terrace Floor - Beam Clear Height Mt. - - 1.00 OK
ST URSLA HOSPITAL ( RELIGIOUS BUILDING) No. of Floors No. - 2 OK
No. of Tenements No. - 2 OK
LOWER GROUND FLOOR PLAN STAIRCASE - Flight Width Mt. 0.750 1.210 OK
STAIRCASE - Tread Width Mt. 0.225 0.300 OK
STAIRCASE - Riser Height Mt. 0.200 0.167 OK
STAIRCASE - Riser No. On Flight No. - 7 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
UPPER GROUND FLOOR PLAN STAIRCASE - Flight Width Mt. 0.750 1.210 OK
STAIRCASE - Tread Width Mt. 0.225 0.254 OK
STAIRCASE - Riser Height Mt. 0.200 0.225 Failed
STAIRCASE - Riser No. On Flight No. - 8 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
TERRACE FLOOR PLAN STAIRCASE - Flight Width Mt. - 1.210 OK
STAIRCASE - Tread Width Mt. - 0.300 OK
STAIRCASE - Riser Height Mt. - - OK
STAIRCASE - Riser No. On Flight No. - - OK
STAIRCASE - Cabin Ht. Mt. 2.100 - 2.130 OK
RAIN WATER HARVESTING Area Sq.Mt. - - 5.68 OK
Width Mt. - - 2.69 OK
Depth Mt. - - 2.69 OK
Height Mt. - - - OK
ENT.GATE Area Sq.Mt. - - 10.54 OK
Width Mt. - - 0.97 OK
Depth Mt. - - 11.49 OK
Height Mt. - - - OK
SOLAR HEATING SYSTEM Area Sq.Mt. - - 43.47 OK
Width Mt. - - 4.85 OK
Depth Mt. - - 8.97 OK
Height Mt. - - - OK
ST URSLA HOSPITAL ( RELIGIOUS BUILDING) Rain Water Harvesting - No No. 1 - 1 OK
PLOT 7.00 mt. long 1.70 mt. High 4.50 mt. Wide Pedestrian Ramp - Width Mt. 4.50 2.05 Failed
7.00 mt. long 1.70 mt. High 4.50 mt. Wide Pedestrian Ramp - Depth Mt. 1.00 1.70 OK
7.00 mt. long 1.70 mt. High 4.50 mt. Wide Pedestrian Ramp - Slope Ratio 1.00 : 7.00 - 01 : 05 Failed
7.00 mt. long 1.70 mt. High 4.50 mt. Wide Pedestrian Ramp - Width Mt. 4.50 2.05 Failed
7.00 mt. long 1.70 mt. High 4.50 mt. Wide Pedestrian Ramp - Depth Mt. 1.00 1.70 OK
7.00 mt. long 1.70 mt. High 4.50 mt. Wide Pedestrian Ramp - Slope Ratio 1.00 : 7.00 - 01 : 05 Failed
4.66 mt. long 1.50 mt. High 3.65 mt. Wide Pedestrian Ramp - Width Mt. 3.30 3.65 OK
4.66 mt. long 1.50 mt. High 3.65 mt. Wide Pedestrian Ramp - Depth Mt. 1.00 1.50 OK
4.66 mt. long 1.50 mt. High 3.65 mt. Wide Pedestrian Ramp - Slope Ratio 1.00 : 7.00 - 01 : 04 Failed
4.66 mt. long 1.50 mt. High 3.65 mt. Wide Pedestrian Ramp - Width Mt. 3.30 3.65 OK
4.66 mt. long 1.50 mt. High 3.65 mt. Wide Pedestrian Ramp - Depth Mt. 1.00 1.50 OK
4.66 mt. long 1.50 mt. High 3.65 mt. Wide Pedestrian Ramp - Slope Ratio 1.00 : 7.00 - 01 : 04 Failed
Ramp No. ST URSLA HOSPITAL ( RELIGIOUS BUILDING) - LOWER GROUND FLOOR PLAN - No. No. - 3 OK
ST URSLA HOSPITAL ( RELIGIOUS BUILDING) - UPPER GROUND FLOOR PLAN - No. No. - 1 OK
   
    All Rooms are as per Rule in Room Checking




[-] Rules
Topic Rule
Plot Level
Plot Area The minimum size of plot for Place of congregation, Community Hall category shall be 500.0 sq.mt.{As per Rule No. 35.1, Table 7 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Width The minimum size of plot for Place of congregation, Community Hall category shall be 500.0 sq.mt.{As per Rule No. 35.1, Table 7 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Depth The minimum size of plot for Place of congregation, Community Hall category shall be 500.0 sq.mt.{As per Rule No. 35.1, Table 7 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
Access Width The minimum width of abutting road for Place of congregation, Community Hall category shall be 12.20 mt.{As per Rule No. 35.1, Table 7}
Plot Frontage The minimum size of plot for Place of congregation, Community Hall category shall be 500.0 sq.mt.{As per Rule No. 35.1, Table 7 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
FAR Area (1) For Educational, Institutional and Assembly building above 1000 sq.mt. Plot area, the Floor Area Ratio-FAR shall be 2.25 {As per Rule No. 39.3}
(2) For Lohardaga Nagar Parishad, Max. 2.0 permissible FAR may be permitted for Commercial or Mercantile type Use {As per Annexure III}
Consumed FAR (1) For Educational, Institutional and Assembly building above 1000 sq.mt. Plot area, the Floor Area Ratio-FAR shall be 2.25 {As per Rule No. 39.3}
(2) For Lohardaga Nagar Parishad, Max. 2.0 permissible FAR may be permitted for Commercial or Mercantile type Use {As per Annexure III}
Common Plot Area In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
Common Plot (1) ; In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
(2) ;
(3) In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
(4) ;
Tree Number Mini. 8 Trees shall be required for the Plot area above 1000.0 sq.mt. (As per Rule No. 20.1.6)
Building Level
Building Height For old area, on Road width 12.20-18.30 mt., Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 30.0 mt. {As per Rule No. 39.1 Table 15}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
Parapet Height (1) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
(2) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
(3) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
Floor Number For old area location,on Road width 12.20-18.30 mt., Maximum Height 30 meter shall be allowed. {As per Rule No. 39.1 Table 15}
StairCase (1) Width of Winding staircase shall be mini. 0.75 mt.,Maximum rise 0.20 mt. & Minimum tread 0.225 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) Width of Winding staircase shall be mini. 0.75 mt.,Maximum rise 0.20 mt. & Minimum tread 0.225 mt. & Cabin height 2.1 mt {As per Rule No. 83.18}
(4) ; No Rule Defined
Ramp For parking spaces in basements and upper storey of parking floors,if car parking is less then 40, one ramp of minimum of 3.30m width if it is strait and 4.5m width if it is curved at any point and with minimum slope gradient of 1:7 for depth up to 1.8m and 1:10 for more than 1.8m depth shall be provided {As per Rule No. 41.8 and as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017} ;
Ramp No. -
Plot / Building Level
Accessory Use (1) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(2) No need to check distance from Building RAIN WATER HARVESTING
(3) No need to check distance from Building ENT.GATE
(4) -
(5) No need to check distance from Building SOLAR HEATING SYSTEM
Accessory Use Number Provision of Rain Water Harvesting shall be mandatory for any use {Updated as per JBBL, Amendment VIII dated 16/03/2021} Rain Water Harvesting
Building Level (Rooms)