-
No Image Found   

Detail Scrutiny Report

Lohardaga Nagar Parishad

Version Number: 1.0.64  
Version Date: 16/10/2020 
Report Generated On: 10-11-2022 
 
[-] Collapse All


General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictLOHARDAGA
AuthorityLOHARDAGA NAGAR PARISHAD
Inward_NoLNP/BP/0053/W22/2022
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentNew
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillageLohardaga
Taluka26
Architect Details
Architect NameAshish Deep Toppo
License No.LNP/ARC/0009/2017
Architect AddressS/O Atul Kumar Suman Toppo G. E. L. Mission Compound Anandpur
Architect EmailIDashish.d.toppo@gmail.com
Architect Mobile No7992304518
Plot Details
Plot Use Assembly
Plot SubUse Religious Building
PlotNearbyReligiousStructure NA
Plot/SubPlot No3006
NorthPlot No. - 3005
SouthPlot No. - 3005
EastPlot No. - 3004
WestPlot No. - 3007
Owner's Details
NameSt. Ursula Hospital
AddressCollege Road
Email IDashish.d.toppo@gmail.com
Mobile No7992304518
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 1169.00
2 Plot area as per Document by Applicant 1169.00
3 Physical area measured at site 1160.00
4 Area as per Site Visit (Site Visit Report) 1169.00
5Area as per Drawing 1157.75

Area of Plot Considered : 1157.75

[-] Table 2b
Proposal Detail :
UnitMeters
Development Detail :
PlotPLOT
Plot OccupancyAssembly
Plot SubUse Religious Building
Building StructureNon-Highrise
Building TypeSingle Detached House
Gross Plot Area 1157.75
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 1157.75
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 914.09
Deductions for Balance Plot Area (from Gross Plot Area)
- Common Plot 243.66
243.66
Balance Plot Area 914.09

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 50.00 % ) 578.88
Proposed Coverage Area ( 17.63 % ) 204.11
Total Prop. Coverage Area ( 17.63 % ) 204.11
Balance coverage area ( 32.37 % ) 374.77
FAR CHECK
Perm. FAR Area ( 2.000 ) 2315.50
Total Perm. FAR area 2315.50
Special FAR 444.64
Proposed FAR Area 444.64
Total Proposed FAR Area 444.64
Consumed FAR (Factor) 0.38
Balance FAR Area 1870.86
BUA CHECK
Total Proposed BuiltUp Area 499.62


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Exceeding 50 meter and upto 100 meter -
Existing Road Width 6.05 12.20
Proposed Road Width as per Master Plan 6.05 -
Road Widening Width 0 -
Plot size (as per measurement) 1169 1157.75

[-] Road width Details Checks
No Rule Status
1 For Existing Road Width, value as per site visit and value as per drawing should be same. Failed
[-] Extra Land Area Checks
Name Area Status
Reqd Prop
Extra Land - 0.00 OK


[-] Plot Level Checking (Table 3)
   
[-] Common Plot Checks (Table 3b)
Name Total Area Status
Reqd Prop
Common Plot 115.78 243.66 OK


[-] Common Plot Checks (Table 3b)
Name Minimum Area Coverage Area Width Angle Access Status
Reqd Prop Perm Prop Reqd Prop Reqd Prop
Tree Cover (Plantation) - 109.26 0.00 0.00 - 3.44 - 89.89 No Access Provided OK
Tree Cover (Plantation) - 134.40 0.00 0.00 - 4.86 - 84.82 No Access Provided OK


   
   
[-] Tree Details (Table 3g)
Name Nos Of Trees Status
Reqd Prop
Tree 8 8 OK
   
   
   
   
   
    [-] Drawing Checkings

No Rule Status
1 Setback is not checked as per Rule, Please check the Drawing again. Failed

Notice: Please correct the failed entity, you may have the wrong result due to improper drawing.
   


[-] Building Details (Table 4)
   
[-] Building USE/SUBUSE Details Building USE/SUBUSE Details
Building Name Building Use Building SubUse Building Structure
ST URSLA HOSPITAL ( RELIGIOUS BUILDING) Assembly Religious Building Non-Highrise
   
   
   
[-] Height Details (4a)



[-] Total Height (Table 4a-1)
Building Height Height (From GL) Height (From Street LVL) Status
Perm Prop
ST URSLA HOSPITAL ( RELIGIOUS BUILDING) 23.30 4.50 4.50 4.50 OK


   
   
[-] Floor Height Check (Table 4a-2)
Building Name Floor Name Height Clear Height Beam Clear Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
ST URSLA HOSPITAL ( RELIGIOUS BUILDING) Upper Ground Floor 2.75 - 4.50 2.75 - 4.35 2.40 - 4.00 OK
Lower Ground Floor 2.75 - 3.00 2.75 - 2.85 2.40 - 2.50 OK


[-] Parapet Height Check (Table 4a-2.1)
Building Name Floor Name Height Clear Height Beam Clear Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
ST URSLA HOSPITAL ( RELIGIOUS BUILDING) Terrace Floor - - 1.00 - - 1.00 - - 1.00 OK
   
   
   
[-] Floor Number Check (Table 4a-4)
Building Name No. of Floors No. of Tenements Status
Perm Prop Perm Prop
ST URSLA HOSPITAL ( RELIGIOUS BUILDING) - 2 - 2 OK

 
   
    [-] Coverage Check (Table 4b)
Permissible Proposed Status
578.88 204.11 OK
50% 17.63%

[-] Individual Coverage Check
Coverage Area Perm. Prop.
  ST URSLA HOSPITAL-1 ( RELIGIOUS BUILDING) - 204.11
  Total Prop. Coverage Area - 204.11
  Total Coverage Area 578.88 204.11

[-] FAR & Tenement Details (Table 4c-1)
Building No. of Same Bldg Total Built Up Area (Sq.mt.) Deductions (Area in Sq.mt.) Proposed FAR Area (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
Ramp Assembly
ST URSLA HOSPITAL ( RELIGIOUS BUILDING) 1 499.62 54.99 444.64 444.63 444.63 02
Grand Total : 1 499.62 54.99 444.64 444.63 444.63 02


[-] Buildingwise Floor FAR Details
Floor Name Building Name Total
ST URSLA HOSPITAL ( RELIGIOUS BUILDING)
Proposed Built Up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Total Proposed Built Up Area (Sq.mt.) Total FAR Area (Sq.mt.)
Lower Ground Floor 278.97 240.52 278.97 240.52
Upper Ground Floor 220.65 204.11 220.65 204.11
Terrace Floor 0.00 0.00 0.00 0.00
Total : 499.62 444.63 499.62 444.63


[-] UnitBUA Table for Building :ST URSLA HOSPITAL ( RELIGIOUS BUILDING)
UnitBUA CALCULATION
FLOOR Name UnitBUA Type UnitBUA Area Carpet Area No. of Rooms No. of Tenement
LOWER GROUND FLOOR PLAN SPLIT A Public Utility Area 203.77 203.76 3 1
UPPER GROUND FLOOR PLAN SPLIT A Public Utility Area 173.19 173.17 1 1
Total: - - 376.96 376.93 4 2


[-] Building :ST URSLA HOSPITAL ( RELIGIOUS BUILDING)
Floor Name Total Built Up Area (Sq.mt.) Deductions (Area in Sq.mt.) Proposed FAR Area (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
Ramp Assembly
Lower Ground Floor 278.97 38.45 240.52 240.52 240.52 01
Upper Ground Floor 220.65 16.54 204.11 204.11 204.11 01
Terrace Floor 0.00 0.00 0.00 0.00 0.00 00
Total : 499.62 54.99 444.64 444.63 444.63 02
Total Number of Same Buildings : 1
Total : 499.62 54.99 444.64 444.63 444.63 02
[-] Table 4c-2

  FAR Area
Building FAR Area:444.64
Existing FAR Area :0.00
Perm.
2315.50
Prop.
444.64
Status
OK




[-] Margin Checks (Table 5)
   
[-] Plot Margin (Table 5a)
Building / Wing Road Name Front Side Rear Side Side1 Side2 Status
Reqd. Prop. Reqd. Prop. Reqd. Prop. Reqd. Prop.
ST URSLA HOSPITAL-1 ( RELIGIOUS BUILDING) 12.20MT MAIN ROAD Access Road - 5.00 - 8.19 - 7.73 - 14.04 OK






[-] Inner Building Details (Table 6)
   

No OTS/Duct/VShaft/Balcony/Passage/Lift/Tenements Found.
   


[-] Parking Details (Table 7)
   
[-] Required Parking(Table 7a)
Building Name Type SubUse Area (Sq.mt.) Units Car
Reqd. Prop. Reqd./Unit Reqd. Prop.
ST URSLA HOSPITAL ( RELIGIOUS BUILDING) Assembly Religious Building > 0 15 - 1 1 -
> 0 15 - - - -
Total : - - - - 1 1

[-] Parking Check (Table 7b)
Vehicle Type Reqd. Prop. Status
No. Area No. Area
Car - - 1 12.89 OK
Total Car 1 12.50 1 12.89 OK
Total 12.50 12.89 OK

Individual Parking Checks (Table 7c)
Dimensions and Area for all Vehicle(s) are as per the Rules


   


[-] Exemption Details (Table 8)
   


Not Required to Check StairCase Number Rule.


[-] Staircase Checks (Table 8a-1)


[-] For Building :ST URSLA HOSPITAL ( RELIGIOUS BUILDING)
Floor Name StairCase Name Flight Width Tread Width Riser Height Riser No. On Flight Cabin Ht. Status
Reqd Prop Reqd Prop Perm Prop Perm Prop Reqd Perm Prop
LOWER GROUND FLOOR PLAN STAIRCASE 0.750 1.210 0.225 0.300 0.200 0.167 - 7 - - 0.000 OK
UPPER GROUND FLOOR PLAN STAIRCASE 0.750 1.210 0.225 0.254 0.200 0.225 - 8 - - 0.000 Failed
TERRACE FLOOR PLAN STAIRCASE - 1.210 - 0.300 - 0.000 - 0 2.100 - 2.130 OK

   
   
   

[-] Ramp Checks (Table 8b-a)
Ramp Name Width Depth Slope Status
Reqd Prop Reqd Prop Reqd Perm Prop
7.00 mt. long 1.70 mt. High 4.50 mt. Wide Pedestrian Ramp 4.50 2.05 1.00 1.70 1.00 : 7.00 - 01 : 05 Failed
7.00 mt. long 1.70 mt. High 4.50 mt. Wide Pedestrian Ramp 4.50 2.05 1.00 1.70 1.00 : 7.00 - 01 : 05 Failed
4.66 mt. long 1.50 mt. High 3.65 mt. Wide Pedestrian Ramp 3.30 3.65 1.00 1.50 1.00 : 7.00 - 01 : 04 Failed
4.66 mt. long 1.50 mt. High 3.65 mt. Wide Pedestrian Ramp 3.30 3.65 1.00 1.50 1.00 : 7.00 - 01 : 04 Failed


[-] Ramp Checks (Table 8b)
Building Name Floor Name No. Status
Reqd Prop
ST URSLA HOSPITAL ( RELIGIOUS BUILDING) LOWER GROUND FLOOR PLAN - 3 OK
UPPER GROUND FLOOR PLAN - 1 OK

   
   
   
[-] Accessory Use Check (Table 8d)
Accessory Use Name Area Width Depth Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
RAIN WATER HARVESTING - - 5.68 - - 2.69 - - 2.69 - - 0.00 OK
ENT.GATE - - 10.54 - - 0.97 - - 11.49 - - 0.00 OK
SOLAR HEATING SYSTEM - - 43.47 - - 4.85 - - 8.97 - - 0.00 OK





[-] Accessory Use No. Checks
Building Name Accessory Use Name No Status
Reqd Perm Prop
ST URSLA HOSPITAL ( RELIGIOUS BUILDING) Rain Water Harvesting 1 - 1 OK
   
   


[-] Floor Details (Table 9)
   

[-] Building:ST URSLA HOSPITAL ( RELIGIOUS BUILDING)


[-] Floor:LOWER GROUND FLOOR PLAN



Not Required to Check Dimensions and Area of all the Rooms on this Floor Rule.

[-] Floor:UPPER GROUND FLOOR PLAN



Not Required to Check Dimensions and Area of all the Rooms on this Floor Rule.


   


[-] Summary (Table 10)
   
Name Perm./Reqd. Proposed Status
  Plot Area 500.00 1157.75 OK
  Plot Width - 35.10 OK
  Plot Depth - 32.98 OK
  Access Width 12.20 12.20 OK
  Plot Frontage - 39.67 OK
  Coverage Area 578.88 204.11 OK
  FAR Area
Bldg. FAR Area : 444.64
Sanctioned FAR Area :0.00
2315.50 444.64 OK





[-] Rules
Topic Rule
Plot Level
Plot Area The minimum size of plot for Place of congregation, Community Hall category shall be 500.0 sq.mt.{As per Rule No. 35.1, Table 7 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Width The minimum size of plot for Place of congregation, Community Hall category shall be 500.0 sq.mt.{As per Rule No. 35.1, Table 7 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Depth The minimum size of plot for Place of congregation, Community Hall category shall be 500.0 sq.mt.{As per Rule No. 35.1, Table 7 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
Access Width The minimum width of abutting road for Place of congregation, Community Hall category shall be 12.20 mt.{As per Rule No. 35.1, Table 7}
Plot Frontage The minimum size of plot for Place of congregation, Community Hall category shall be 500.0 sq.mt.{As per Rule No. 35.1, Table 7 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
FAR Area (1) For Educational, Institutional and Assembly building above 1000 sq.mt. Plot area, the Floor Area Ratio-FAR shall be 2.25 {As per Rule No. 39.3}
(2) For Lohardaga Nagar Parishad, Max. 2.0 permissible FAR may be permitted for Commercial or Mercantile type Use {As per Annexure III}
Consumed FAR (1) For Educational, Institutional and Assembly building above 1000 sq.mt. Plot area, the Floor Area Ratio-FAR shall be 2.25 {As per Rule No. 39.3}
(2) For Lohardaga Nagar Parishad, Max. 2.0 permissible FAR may be permitted for Commercial or Mercantile type Use {As per Annexure III}
Common Plot Area In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
Common Plot (1) ; In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
(2) ;
(3) In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
(4) ;
Tree Number Mini. 8 Trees shall be required for the Plot area above 1000.0 sq.mt. (As per Rule No. 20.1.6)
Building Level
Building Height For old area, on Road width 12.20-18.30 mt., Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 30.0 mt. {As per Rule No. 39.1 Table 15}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
Parapet Height (1) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
(2) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
(3) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
Floor Number For old area location,on Road width 12.20-18.30 mt., Maximum Height 30 meter shall be allowed. {As per Rule No. 39.1 Table 15}
StairCase (1) Width of Winding staircase shall be mini. 0.75 mt.,Maximum rise 0.20 mt. & Minimum tread 0.225 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) Width of Winding staircase shall be mini. 0.75 mt.,Maximum rise 0.20 mt. & Minimum tread 0.225 mt. & Cabin height 2.1 mt {As per Rule No. 83.18}
(4) ; No Rule Defined
Ramp For parking spaces in basements and upper storey of parking floors,if car parking is less then 40, one ramp of minimum of 3.30m width if it is strait and 4.5m width if it is curved at any point and with minimum slope gradient of 1:7 for depth up to 1.8m and 1:10 for more than 1.8m depth shall be provided {As per Rule No. 41.8 and as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017} ;
Ramp No. -
Plot / Building Level
Accessory Use (1) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(2) No need to check distance from Building RAIN WATER HARVESTING
(3) No need to check distance from Building ENT.GATE
(4) -
(5) No need to check distance from Building SOLAR HEATING SYSTEM
Accessory Use Number Provision of Rain Water Harvesting shall be mandatory for any use {Updated as per JBBL, Amendment VIII dated 16/03/2021} Rain Water Harvesting
Building Level (Rooms)