-
No Image Found   

Check List Report

Lohardaga Nagar Parishad

Version Number: 1.0.66  
Version Date: 16/10/2020 
Report Generated On: 21-08-2023 
 

[-] Collapse All


General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictLOHARDAGA
AuthorityLOHARDAGA NAGAR PARISHAD
Inward_NoLNP/BP/0023/W14/2023
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentAddition or Alteration
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillageLohardaga
Taluka26
Layout Sanction No34/2010
Layout Sanction Date12/5/2011
Architect Details
Architect NameASHWINI KUMAR SAHU
License No.LNP/ENG/0005/2017
Architect AddressNear check post, PWD Road
Architect EmailIDerashwinisahu@gmail.com
Architect Mobile No9308730823
Plot Details
Plot Use Commercial
Plot SubUse Commercial Bldg
PlotNearbyReligiousStructure NA
Plot/SubPlot No523
North -
South -
East -
WestRoad Width - 12.2 METER ROAD
Owner's Details
NameMANOJ KUMAR JAISWAL
AddressHOTEL PEARL NEW ROAD LOHARDAGA
Email IDSOALOHARDAGA@GMAIL.COM
Mobile No7488523541
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 548.37
2 Plot area as per Document by Applicant 548.37
3 Physical area measured at site 548.37
4 Area as per Site Visit (Site Visit Report) 548.37
5Area as per Drawing 548.24

Area of Plot Considered : 548.24

[-] Table 2b
Proposal Detail :
Unit
Development Detail :
PlotPLOT
Plot OccupancyCommercial
Plot SubUse Commercial Bldg
Building StructureNon-Highrise
Building TypeSingle Detached House
Gross Plot Area 548.24
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 548.24
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 480.84
Deductions for Balance Plot Area (from Gross Plot Area)
- Common Plot 67.40
67.40
Balance Plot Area 480.84

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 50.00 % ) 274.12
Proposed Coverage Area ( 37.84 % ) 207.46
Total Prop. Coverage Area ( 37.84 % ) 207.46
Balance coverage area ( 12.16 % ) 66.66
FAR CHECK
Perm. FAR Area ( 2.000 ) 1096.48
Total Perm. FAR area 1096.48
Commercial FAR 919.02
Proposed FAR Area 919.02
Total Proposed FAR Area 919.02
Consumed FAR (Factor) 1.68
Balance FAR Area 177.46
BUA CHECK
Total Proposed BuiltUp Area 1037.29


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Up to 50 meter -
Existing Road Width 12.2 12.20
Proposed Road Width as per Master Plan 12.2 -
Road Widening Width 0 -
Plot size (as per measurement) 548.37 548.24
[-] Extra Land Area Checks
Name Area Status
Reqd Prop
Extra Land - 0.00 OK

     Extra Land Area Details
Name Description Unit Reqd Perm Proposed Status
Extra Land Area Details Extra Land Area - - 0.00 OK

     Plot Related Details
Name Description Unit Reqd Perm Proposed Status
PLOT Plot Area Sq.Mt. - - 548.24 OK
Plot Width Mt. - - 12.89 OK
Plot Depth Mt. - - 42.54 OK
Access Width Mt. 6.10 - 12.20 OK
Plot Frontage Mt. - - 12.85 OK
Coverage Area Sq.Mt. - 274.12 207.46 OK
FAR Area Sq.Mt. - 1096.48 919.02 OK
Consumed FAR Sq.Mt. - 2.00 1.68 OK
Common Plot Checks Common Plot - Total Area Sq.Mt. 27.41 67.40 OK
Common Plot Tree Cover (Plantation) - Minimum Area Sq.Mt. - 67.40 OK
Tree Cover (Plantation) - Coverage Area Sq.Mt. - - OK
Tree Cover (Plantation) - Width Mt. - 5.07 OK
Tree Cover (Plantation) - Angle Degree - 88.59 OK
Tree Cover (Plantation) - Access Mt. - OK
Tree Tree - Nos Of Trees No. 4 13 OK
Car In Area Sq.Mt. - - 37.50 OK
Three Stack.Car In Area Sq.Mt. - - 75.00 OK
Total Car In Area Sq.Mt. 37.50 - 112.50 OK
Visitor's Car Parking In Area Sq.Mt. - - 25.00 OK
Total Visitor Parking In Area Sq.Mt. - - 25.00 OK
TwoWheeler In Area Sq.Mt. - - 30.00 OK
Total TwoWheeler In Area Sq.Mt. 20.00 - 30.00 OK
DriveWay PLOT - - - DRIVEWAY - Width No. 3.60 - 5.80 OK
A-1 (MANOJ KUMAR JAISWAL) Front Margin... 12.20 MTR METER ROAD Access Road Mt. 7.50 - 14.18 OK
Rear Margin Mt. 4.50 - 4.68 OK
Side1 Margin Mt. 2.00 - 2.02 OK
Side2 Margin Mt. 2.00 - 2.06 OK

     Building Related Details
Name Description Unit Reqd Perm Proposed Status
A (MANOJ KUMAR JAISWAL) Height Mt. 30.00 14.69 OK
A (MANOJ KUMAR JAISWAL) Fourth Floor - Height Mt. 2.75 - 2.95 OK
Fourth Floor - Clear Height Mt. 2.75 - 2.88 OK
Fourth Floor - Beam Clear Height Mt. 2.40 - 2.71 OK
Third Floor - Height Mt. 2.75 - 2.95 OK
Third Floor - Clear Height Mt. 2.75 - 2.88 OK
Third Floor - Beam Clear Height Mt. 2.40 - 2.71 OK
Second Floor - Height Mt. 2.75 - 2.95 OK
Second Floor - Clear Height Mt. 2.75 - 2.88 OK
Second Floor - Beam Clear Height Mt. 2.40 - 2.71 OK
First Floor - Height Mt. 2.75 - 2.95 OK
First Floor - Clear Height Mt. 2.75 - 2.88 OK
First Floor - Beam Clear Height Mt. 2.40 - 2.71 OK
Ground Floor - Height Mt. 2.75 - 2.88 OK
Ground Floor - Clear Height Mt. 2.75 - 2.80 OK
Ground Floor - Beam Clear Height Mt. 2.40 - 2.63 OK
Plinth - Height Mt. 0.45 - 0.60 OK
Plinth - Clear Height Mt. - - 0.60 OK
Plinth - Beam Clear Height Mt. - - 0.60 OK
A (MANOJ KUMAR JAISWAL) Terrace Floor - Height Mt. - - 1.07 OK
Terrace Floor - Clear Height Mt. - - 1.07 OK
Terrace Floor - Beam Clear Height Mt. - - 1.07 OK
A (MANOJ KUMAR JAISWAL) No. of Floors No. - 5 OK
No. of Tenements No. - 8 OK
A (MANOJ KUMAR JAISWAL) Number Of Lift(s) No. 1 1 OK
Number Of Strature Lift(s) No. - - OK
Capacity Of Lift(s) Passanger No. 6 13 OK
A (MANOJ KUMAR JAISWAL) THIRD FLOOR PLAN - PASSENGER LIFT for 13 Persons - Width Mt. 1.90 2.10 OK
THIRD FLOOR PLAN - PASSENGER LIFT for 13 Persons - Depth Mt. 2.50 2.96 OK
FOURTH FLOOR PLAN - PASSENGER LIFT for 13 Persons - Width Mt. 1.90 2.10 OK
FOURTH FLOOR PLAN - PASSENGER LIFT for 13 Persons - Depth Mt. 2.50 2.96 OK
TERRACE FLOOR PLAN - Lift Machine Room - Width Mt. 1.70 2.10 OK
TERRACE FLOOR PLAN - Lift Machine Room - Depth Mt. 1.90 2.96 OK
THIRD FLOOR PLAN STAIRCASE - Flight Width Mt. 0.900 0.950 OK
STAIRCASE - Tread Width Mt. 0.250 0.250 OK
STAIRCASE - Riser Height Mt. 0.200 0.148 OK
STAIRCASE - Riser No. On Flight No. - 10 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
FOURTH FLOOR PLAN STAIRCASE - Flight Width Mt. 0.900 0.950 OK
STAIRCASE - Tread Width Mt. 0.250 0.250 OK
STAIRCASE - Riser Height Mt. 0.200 0.148 OK
STAIRCASE - Riser No. On Flight No. - 10 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
TERRACE FLOOR PLAN STAIRCASE - Flight Width Mt. - 0.950 OK
STAIRCASE - Tread Width Mt. - 0.250 OK
STAIRCASE - Riser Height Mt. - - OK
STAIRCASE - Riser No. On Flight No. - - OK
STAIRCASE - Cabin Ht. Mt. - - 2.550 OK
Sewage Treatment Plant Area Sq.Mt. - - 0.94 OK
Width Mt. - - 0.82 OK
Depth Mt. - - 1.15 OK
Height Mt. - - - OK
RAIN WATER HARVESTING Area Sq.Mt. - - 2.12 OK
Width Mt. - - 1.04 OK
Depth Mt. - - 2.05 OK
Height Mt. - - - OK
ENT.GATE Area Sq.Mt. - - 2.23 OK
Width Mt. - - 0.62 OK
Depth Mt. - - 3.59 OK
Height Mt. - - - OK
Entrance Lobby Area Sq.Mt. - 12.00 6.25 OK
Width Mt. - - 1.50 OK
Depth Mt. - - 4.17 OK
Height Mt. - - - OK
Area Sq.Mt. - 12.00 6.05 OK
Width Mt. - - 1.50 OK
Depth Mt. - - 4.04 OK
Height Mt. - - - OK
Area Sq.Mt. - 12.00 4.92 OK
Width Mt. - - 1.20 OK
Depth Mt. - - 4.10 OK
Height Mt. - - - OK
Area Sq.Mt. - 12.00 0.91 OK
Width Mt. - - 0.78 OK
Depth Mt. - - 1.18 OK
Height Mt. - - - OK
Area Sq.Mt. - 12.00 7.22 OK
Width Mt. - - 1.88 OK
Depth Mt. - - 3.85 OK
Height Mt. - - - OK
Area Sq.Mt. - 12.00 6.98 OK
Width Mt. - - 1.88 OK
Depth Mt. - - 3.73 OK
Height Mt. - - - OK
Area Sq.Mt. - 12.00 2.79 OK
Width Mt. - - 1.18 OK
Depth Mt. - - 2.38 OK
Height Mt. - - - OK
Area Sq.Mt. - 12.00 6.84 OK
Width Mt. - - 2.23 OK
Depth Mt. - - 3.08 OK
Height Mt. - - - OK
Area Sq.Mt. - 12.00 6.95 OK
Width Mt. - - 2.38 OK
Depth Mt. - - 2.93 OK
Height Mt. - - - OK
SOLAR HEATING SYSTEM Area Sq.Mt. - - 2.04 OK
Width Mt. - - 1.04 OK
Depth Mt. - - 1.97 OK
Height Mt. - - - OK
A (MANOJ KUMAR JAISWAL) Rain Water Harvesting - No No. 1 - 1 OK
Entrance Gate - No No. 1 - 1 OK
   
    All Rooms are as per Rule in Room Checking




[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Width No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Depth No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Access Width The minimum width of abutting road for any Building more than 13.3 mt. ht. shall be 6.1 mt.{As per Rule no. 35.1 Note 4}
Plot Frontage No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
FAR Area (1) In Old Area, for Non-Residential Building on abutting roadwidth 12.20 (40 ft.) to 18.30 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15}
(2) For Lohardaga Nagar Parishad, Max. 2.0 permissible FAR may be permitted for Commercial or Mercantile type Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Non-Residential Building on abutting roadwidth 12.20 (40 ft.) to 18.30 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15}
(2) For Lohardaga Nagar Parishad, Max. 2.0 permissible FAR may be permitted for Commercial or Mercantile type Use {As per Annexure III}
Common Plot Area In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
Common Plot (1) In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
(2) ;
Tree Number 4-8 Trees shall be required for the Plot area above 250.0 and upto 1000.0 sq.mt. (As per Rule No. 20.1.6)
DriveWay Rule For Plor area upto 2000 sq.mt., the minimum width or driveways should not be less than 3.60 mt. {As per Rule No. 41.2 and modified as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
Margin Rule For Non-highrise Commercial Building upto 16.4 mt. Ht. having Plot Depth 39-45 mt. and Plot width 10-15 mt., Margin required in Front shall be 7.5 mt., Rear 4.5 mt. and 2.0 mt. shall be provided on both side. {As per Rule No. 36 Table 10 & 11}
Building Level
Building Height For old area, on Road width 12.20-18.30 mt., Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 30.0 mt. {As per Rule No. 39.1 Table 15}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(3) The plinth or any part of a building shall be so located with respect to the surrounding ground level that adequate drainage of the site is assured. The height of the plinth (except in case of stilted parking) shall be not less than 0.45 mt. from the surrounding ground level {As per Rule No. 42.10}
Parapet Height (1) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
(2) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
(3) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
Floor Number For old area location,on Road width 12.20-18.30 mt., Maximum Height 30 meter shall be allowed. {As per Rule No. 39.1 Table 15}
Lift Count (1) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(2) For Non-Residential Building, Minimum number of lifts to be 2 for all non-residential building above ground + 2 and the minimum capacity shall be 6 persons per floor. {As per Rule No. 49.2.3 and as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
Lift (1) The area of lift well shall not be counted for F.A.R calculation)
(2) The lift shall have a minimum width 1.9 mt. and minimum depth 2.5 mt.{As per clause no 4 and page no. 14 NBC }
(3) -
StairCase (1) Width of Winding staircase shall be mini. 0.90 mt.,Maximum rise 0.20 mt. & Minimum tread 0.25 mt. & Cabin Height 2.1 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) No Rule Defined
(4) ; No Rule Defined
Plot / Building Level
Accessory Use (1) -
(2) No need to check distance from Building Sewage Treatment Plant
(3) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(4) No need to check distance from Building RAIN WATER HARVESTING
(5) No need to check distance from Building ENT.GATE
(6) Entrance Lobby of maximum size of 12 sq.m. shall be taken Free from FAR
(7) No need to check distance from Building Entrance Lobby
(8) -
(9) No need to check distance from Building SOLAR HEATING SYSTEM
Accessory Use Number (1) Provision of Rain Water Harvesting shall be mandatory for any use {Updated as per JBBL, Amendment VIII dated 16/03/2021} Rain Water Harvesting
(2) In case of buildings with a height of 15.0 meters and above or ground coverage more than 500 sqm., the main entrance to the premise shall not be less than 5 (five) meters i n width in order to allow easy access to fire engine Entrance Gate
Building Level (Rooms)