No Image Found   

Check List Report

Lohardaga Nagar Parishad

Version Number: 1.0.68  
Version Date: 16/10/2020 
Report Generated On: 09-01-2024 
 

[-] Collapse All


General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictLOHARDAGA
AuthorityLOHARDAGA NAGAR PARISHAD
Inward_NoLNP/BP/0037/W04/2023
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentNew
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillageKatmu
Taluka26
Architect Details
Architect NameSUNIL KUMAR
License No.LNP/ENG/0004/2017
Architect AddressBARWATOLI
Architect EmailIDsunil7527@gmail.com
Architect Mobile No7292899641
Plot Details
Plot Use Mixed
Plot SubUse Resi+Comm
PlotNearbyReligiousStructure NA
Plot/SubPlot No834
North -
South -
East -
West -
Owner's Details
NameDILIP SAHU AND SUNITA DEVI
AddressBLOCK MORE MAIN ROAD LOHARDAGA
Email IDsunil7527@gmail.com
Mobile No6205241682
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 453.41
2 Plot area as per Document by Applicant 453.41
3 Physical area measured at site 452.95
4 Area as per Site Visit (Site Visit Report) 452.95
5Area as per Drawing 452.96

Area of Plot Considered : 452.95

Plot area provided in drawing shall not be more than Plot area as per Document.
[-] Table 2b
Proposal Detail :
Unit
Development Detail :
PlotPLOT
Plot OccupancyMixed
Plot SubUse -
Higher Plot Use
Higher Plot Sub UseResi+Comm
Lower Plot Use
Lower Plot Sub Use
Building StructureNon-Highrise
Building TypeSingle Detached House
Gross Plot Area 452.95
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 452.95
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 391.11
Deductions for Balance Plot Area (from Gross Plot Area)
- Common Plot 61.84
61.84
Balance Plot Area 391.11

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 60.00 % ) 271.77
Proposed Coverage Area ( 58.29 % ) 264.02
Total Prop. Coverage Area ( 58.29 % ) 264.02
Balance coverage area ( 1.71 % ) 7.75
FAR CHECK
Perm. FAR Area ( 2.000 ) 905.90
Total Perm. FAR area 905.90
Residential FAR 254.30
Commercial FAR 254.16
Proposed FAR Area 525.03
Total Proposed FAR Area 525.03
Consumed FAR (Factor) 1.16
Balance FAR Area 380.87
BUA CHECK
Total Proposed BuiltUp Area 779.24


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Exceeding 1000 meter -
Existing Road Width 14.6 14.60
Proposed Road Width as per Master Plan 14.6 -
Road Widening Width 0 -
Plot size (as per measurement) 452.95 452.96
[-] Extra Land Area Checks
Name Area Status
Reqd Prop
Extra Land - 0.00 OK

     Extra Land Area Details
Name Description Unit Reqd Perm Proposed Status
Extra Land Area Details Extra Land Area - - 0.00 OK

     Plot Related Details
Name Description Unit Reqd Perm Proposed Status
PLOT Plot Area Sq.Mt. - - 452.95 OK
Plot Width Mt. - - 9.30 OK
Plot Depth Mt. - - 48.73 OK
Access Width Mt. - - 14.60 OK
Plot Frontage Mt. - - 7.62 OK
Coverage Area Sq.Mt. - 271.77 264.02 OK
FAR Area Sq.Mt. - 905.90 525.03 OK
Consumed FAR Sq.Mt. - 2.00 1.16 OK
Common Plot Checks Common Plot - Total Area Sq.Mt. 45.30 61.84 OK
Common Plot Tree Cover (Plantation) - Minimum Area Sq.Mt. - 61.84 OK
Tree Cover (Plantation) - Coverage Area Sq.Mt. - - OK
Tree Cover (Plantation) - Width Mt. - 1.80 OK
Tree Cover (Plantation) - Angle Degree - 84.13 OK
Tree Cover (Plantation) - Access Mt. - OK
Tree Tree - Nos Of Trees No. 4 9 OK
Car In Area Sq.Mt. - - 50.00 OK
Total Car In Area Sq.Mt. 37.50 - 50.00 OK
Visitor's Car Parking In Area Sq.Mt. - - 12.50 OK
Total Visitor Parking In Area Sq.Mt. 12.50 - 12.50 OK
TwoWheeler In Area Sq.Mt. - - 24.00 OK
Total TwoWheeler In Area Sq.Mt. 14.00 - 24.00 OK
Other Parking In Area Sq.Mt. - - 185.46 OK
DriveWay PLOT - - - drive way wide 3.65m - Width No. 3.60 - 3.65 OK
ABC (123) - GROUND FLOOR PLAN - drive way wide 3.65 m - Width No. 3.60 - 3.65 OK
ABC-1 (123) Front Margin... 14.60 M MAINROAD Access Road Mt. 4.00 - 8.00 OK
Rear Margin Mt. 4.00 - 7.23 OK
Side1 Margin Mt. 0.90 - 1.30 OK
Side2 Margin Mt. - - 0.04 OK

     Building Related Details
Name Description Unit Reqd Perm Proposed Status
ABC (123) Height Mt. 29.90 9.00 OK
ABC (123) Second Floor - Height Mt. 2.75 - 3.00 OK
Second Floor - Clear Height Mt. 2.75 - 2.90 OK
Second Floor - Beam Clear Height Mt. 2.40 - 2.75 OK
First Floor - Height Mt. 2.75 - 3.00 OK
First Floor - Clear Height Mt. 2.75 - 2.90 OK
First Floor - Beam Clear Height Mt. 2.40 - 2.75 OK
Ground Floor - Height Mt. 2.75 - 3.00 OK
Ground Floor - Clear Height Mt. 2.75 - 2.90 OK
Ground Floor - Beam Clear Height Mt. 2.40 - 2.75 OK
Plinth - Height Mt. 0.45 - 0.60 OK
Plinth - Clear Height Mt. - - 0.60 OK
Plinth - Beam Clear Height Mt. - - 0.60 OK
ABC (123) Terrace Floor - Height Mt. - - 1.20 OK
Terrace Floor - Clear Height Mt. - - 1.20 OK
Terrace Floor - Beam Clear Height Mt. - - 1.20 OK
ABC (123) No. of Floors No. - 3 OK
No. of Tenements No. - 2 OK
ABC (123) Number Of Lift(s) No. - 1 OK
Number Of Strature Lift(s) No. - - OK
Capacity Of Lift(s) Passanger No. - 6 OK
ABC (123) GROUND FLOOR PLAN - Lift - Width Mt. 1.70 1.78 OK
GROUND FLOOR PLAN - Lift - Depth Mt. 1.90 1.90 OK
FIRST FLOOR PLAN - Lift - Width Mt. 1.70 1.78 OK
FIRST FLOOR PLAN - Lift - Depth Mt. 1.90 1.90 OK
SECOND FLOOR PLAN - Lift - Width Mt. 1.70 1.78 OK
SECOND FLOOR PLAN - Lift - Depth Mt. 1.90 1.90 OK
TERRACE FLOOR PLAN - Lift Machine Room - Width Mt. 1.70 1.78 OK
TERRACE FLOOR PLAN - Lift Machine Room - Depth Mt. 1.90 1.90 OK
GROUND FLOOR PLAN STAIRCASE - Flight Width Mt. 0.900 0.900 OK
STAIRCASE - Tread Width Mt. 0.250 0.251 OK
STAIRCASE - Riser Height Mt. 0.200 0.167 OK
STAIRCASE - Riser No. On Flight No. - 9 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
STAIRCASE - Flight Width Mt. 0.900 0.900 OK
STAIRCASE - Tread Width Mt. 0.250 0.254 OK
STAIRCASE - Riser Height Mt. 0.200 0.158 OK
STAIRCASE - Riser No. On Flight No. - 8 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
FIRST FLOOR PLAN STAIRCASE - Flight Width Mt. 0.900 0.900 OK
STAIRCASE - Tread Width Mt. 0.250 0.254 OK
STAIRCASE - Riser Height Mt. 0.200 0.158 OK
STAIRCASE - Riser No. On Flight No. - 8 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
STAIRCASE - Flight Width Mt. 0.900 0.900 OK
STAIRCASE - Tread Width Mt. 0.250 0.251 OK
STAIRCASE - Riser Height Mt. 0.200 0.167 OK
STAIRCASE - Riser No. On Flight No. - 9 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
SECOND FLOOR PLAN STAIRCASE - Flight Width Mt. 0.900 0.900 OK
STAIRCASE - Tread Width Mt. 0.250 0.254 OK
STAIRCASE - Riser Height Mt. 0.200 0.158 OK
STAIRCASE - Riser No. On Flight No. - 8 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
STAIRCASE - Flight Width Mt. 0.900 0.900 OK
STAIRCASE - Tread Width Mt. 0.250 0.251 OK
STAIRCASE - Riser Height Mt. 0.200 0.167 OK
STAIRCASE - Riser No. On Flight No. - 9 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
TERRACE FLOOR PLAN STAIRCASE - Flight Width Mt. - 0.900 OK
STAIRCASE - Tread Width Mt. - 0.254 OK
STAIRCASE - Riser Height Mt. - - OK
STAIRCASE - Riser No. On Flight No. - - OK
STAIRCASE - Cabin Ht. Mt. - - 2.600 OK
STAIRCASE - Flight Width Mt. - 0.900 OK
STAIRCASE - Tread Width Mt. - 0.251 OK
STAIRCASE - Riser Height Mt. - - OK
STAIRCASE - Riser No. On Flight No. - - OK
STAIRCASE - Cabin Ht. Mt. - - 2.600 OK
SUMP TANK Area Sq.Mt. - - 1.22 OK
Width Mt. - - 0.89 OK
Depth Mt. - - 1.38 OK
Height Mt. - - - OK
RAIN WATER HARVESTING Area Sq.Mt. - - 0.14 OK
Width Mt. - - 0.42 OK
Depth Mt. - - 0.42 OK
Height Mt. - - - OK
ENT.GATE Area Sq.Mt. - - 0.29 OK
Width Mt. - - 0.15 OK
Depth Mt. - - 1.90 OK
Height Mt. - - - OK
SOLAR HEATING SYSTEM Area Sq.Mt. - - 2.42 OK
Width Mt. - - 1.31 OK
Depth Mt. - - 1.85 OK
Height Mt. - - - OK
ABC (123) Rain Water Harvesting - No No. 1 - 1 OK
Entrance Gate - No No. 1 - 1 OK
   
    All Rooms are as per Rule in Room Checking




[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Width No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Depth No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Access Width The minimum width of abutting road for any Building shall be with respect to Length of Road {As per Rule No. 34 Table No.6}
Plot Frontage No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
FAR Area (1) In Old Area, for Non-Residential Building on abutting roadwidth 12.20 (40 ft.) to 18.30 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15}
(2) For Lohardaga Nagar Parishad, Max. 2.0 permissible FAR may be permitted for Commercial or Mercantile type Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Non-Residential Building on abutting roadwidth 12.20 (40 ft.) to 18.30 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15}
(2) For Lohardaga Nagar Parishad, Max. 2.0 permissible FAR may be permitted for Commercial or Mercantile type Use {As per Annexure III}
Common Plot Area In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
Common Plot (1) In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
(2) ;
Tree Number 4-8 Trees shall be required for the Plot area above 250.0 and upto 1000.0 sq.mt. (As per Rule No. 20.1.6)
DriveWay Rule For Plor area upto 2000 sq.mt., the minimum width or driveways should not be less than 3.60 mt. {As per Rule No. 41.2 and modified as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
Margin Rule For Non-highrise Residential Building upto 10.0 mt. Ht. having Plot Depth 39-45 mt. and Plot width upto 10 mt., Margin required in Front shall be 4.0 mt., Rear 4.0 mt. and Atleast 0.9 mt. shall be provided at one side. {As per Rule No. 36 (Table 8 & 9)}
Building Level
Building Height For old area, on Road width 12.20-18.30 mt., Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 30.0 mt. {As per Rule No. 39.1 Table 15}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(3) The plinth or any part of a building shall be so located with respect to the surrounding ground level that adequate drainage of the site is assured. The height of the plinth (except in case of stilted parking) shall be not less than 0.45 mt. from the surrounding ground level {As per Rule No. 42.10}
Parapet Height (1) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
(2) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
(3) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
Floor Number For old area location,on Road width 12.20-18.30 mt., Maximum Height 30 meter shall be allowed. {As per Rule No. 39.1 Table 15}
Lift Count (1) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(2) For Non-Residential Building, No Lift is reqd for Building upto G+2 floor {As per Rule No. 49.2.2}
Lift (1) The area of lift well at one floor only (not the sum of total area of lift well at every floor) shall be counted for F.A.R calculation)
(2) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(3) The area of lift well shall not be counted for F.A.R calculation)
(4) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(5) -
StairCase (1) Width of Winding staircase shall be mini. 0.90 mt.,Maximum rise 0.20 mt. & Minimum tread 0.25 mt. & Cabin Height 2.1 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) No Rule Defined
(4) ; No Rule Defined
Plot / Building Level
Accessory Use (1) -
(2) No need to check distance from Building SUMP TANK
(3) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(4) No need to check distance from Building RAIN WATER HARVESTING
(5) No need to check distance from Building ENT.GATE
(6) -
(7) No need to check distance from Building SOLAR HEATING SYSTEM
Accessory Use Number (1) Provision of Rain Water Harvesting shall be mandatory for any use {Updated as per JBBL, Amendment VIII dated 16/03/2021} Rain Water Harvesting
(2) In case of buildings with a height of 15.0 meters and above or ground coverage more than 500 sqm., the main entrance to the premise shall not be less than 5 (five) meters i n width in order to allow easy access to fire engine Entrance Gate
Building Level (Rooms)
Bed Room3.30x4.20 The area of habitable room shall not be less than 9.5 m2, where there is only one room with a minimum width of 2.4 m. Where there are two rooms, one of these shall not be less than 9.5 m2 and the other not less than 7.5 m2, with a minimum width of 2.1 mt.
Kitchen3.30x2.88 Area for Kitchen shall be Mini. 5.0 sq.mt. having side mini. 1.8 mt. {Rule No. 42.3.2}