No Image Found   

Detail Scrutiny Report

Lohardaga Nagar Parishad

Version Number: 1.0.66  
Version Date: 16/10/2020 
Report Generated On: 01-09-2023 
 
[-] Collapse All


General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictLOHARDAGA
AuthorityLOHARDAGA NAGAR PARISHAD
Inward_NoLNP/BP/0025/W05/2023
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentNew
Location of Development AreaNew Area
City Area/TPScheme NoNA
VillageKaimo
Taluka26
Architect Details
Architect NameRASHID ZAFAR
License No.LNP/ENG/0005/2022
Architect AddressWard 11, Islam Nagar Lohardaga
Architect EmailIDengineerashidz@gmail.com
Architect Mobile No9060065465
Plot Details
Plot Use Residential
Plot SubUse Bungalow/ Dwelling / Non Apartment
PlotNearbyReligiousStructure NA
Plot/SubPlot No1279
NorthPlot No. - 1274
SouthPlot No. - 1279
EastRoad Width - 3.048
WestPlot No. - 1279
Owner's Details
NameDOMNIC GEORGE BAXLA
AddressBRAHMANDIHA SARNA TOLI, NINGNI LOHARDAGA
Email IDdomnicgbaxla@gmail.com
Mobile No9162095587
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 290.36
2 Plot area as per Document by Applicant 290.36
3 Physical area measured at site 290.36
4Area as per Drawing 290.36

Area of Plot Considered : 290.36

[-] Table 2b
Proposal Detail :
UnitMeters
Development Detail :
PlotPLOT
Plot OccupancyResidential
Plot SubUse Bungalow/ Dwelling / Non Apartment
Building StructureNon-Highrise
Building TypeSingle Detached House
Gross Plot Area 290.36
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 290.36
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 246.08
Deductions for Balance Plot Area (from Gross Plot Area)
- Common Plot 44.28
44.28
Balance Plot Area 246.08

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 60.00 % ) 174.22
Proposed Coverage Area ( 41.96 % ) 121.83
Total Prop. Coverage Area ( 41.96 % ) 121.83
Balance coverage area ( 18.04 % ) 52.39
FAR CHECK
Perm. FAR Area ( 1.200 ) 348.43
Total Perm. FAR area 348.43
Residential FAR 217.47
Proposed FAR Area 217.47
Total Proposed FAR Area 217.47
Consumed FAR (Factor) 0.75
Balance FAR Area 130.96
BUA CHECK
Total Proposed BuiltUp Area 231.67


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road -
Existing Road Width 3.04
Proposed Road Width as per Master Plan -
Road Widening Width -
Plot size (as per measurement) 290.36

[-] Road width Details Checks
No Rule Status
1 For Existing Road Width, value as per site visit and value as per drawing should be same. Failed
[-] Extra Land Area Checks
Name Area Status
Reqd Prop
Extra Land - 0.00 OK


[-] Plot Level Checking (Table 3)
   
[-] Common Plot Checks (Table 3b)
Name Total Area Status
Reqd Prop
Common Plot 14.52 44.28 OK


[-] Common Plot Checks (Table 3b)
Name Minimum Area Coverage Area Width Angle Access Status
Reqd Prop Perm Prop Reqd Prop Reqd Prop
Tree Cover (Plantation) - 44.28 0.00 0.00 - 3.22 - 84.95 No Access Provided OK


   
   
[-] Tree Details (Table 3g)
Name Nos Of Trees Status
Reqd Prop
Tree 4 6 OK
   
   
   
   
   


[-] Building Details (Table 4)
   
[-] Building USE/SUBUSE Details Building USE/SUBUSE Details
Building Name Building Use Building SubUse Building Structure
A (BUILDING ) Residential Bungalow/ Dwelling / Non Apartment Non-Highrise
   
   
   
[-] Height Details (4a)



[-] Total Height (Table 4a-1)
Building Height Height (From GL) Height (From Street LVL) Status
Perm Prop
A (BUILDING ) 7.00 6.00 6.00 6.00 OK


   
   
[-] Floor Height Check (Table 4a-2)
Building Name Floor Name Height Clear Height Beam Clear Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
A (BUILDING ) First Floor 2.75 - 3.00 2.75 - 2.90 2.40 - 2.75 OK
Ground Floor 2.75 - 3.00 2.75 - 2.90 2.40 - 2.75 OK
Plinth 0.45 - 0.60 - - 0.60 - - 0.60 OK


[-] Parapet Height Check (Table 4a-2.1)
Building Name Floor Name Height Clear Height Beam Clear Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
A (BUILDING ) Terrace Floor - - 0.90 - - 0.90 - - 0.90 OK
   
   
   
[-] Floor Number Check (Table 4a-4)
Building Name No. of Floors No. of Tenements Status
Perm Prop Perm Prop
A (BUILDING ) G + 1 2 - 1 OK

 
   
    [-] Coverage Check (Table 4b)
Permissible Proposed Status
174.22 121.83 OK
60% 41.96%

[-] Individual Coverage Check
Coverage Area Perm. Prop.
  A-1 (BUILDING ) - 121.83
  Total Prop. Coverage Area - 121.83
  Total Coverage Area 174.22 121.83

[-] FAR & Tenement Details (Table 4c-1)
Building No. of Same Bldg Total Built Up Area (Sq.mt.) Deductions (Area in Sq.mt.) Proposed FAR Area (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
Parking Resi.
A (BUILDING ) 1 231.67 14.21 217.46 217.46 217.46 01
Grand Total : 1 231.67 14.21 217.46 217.46 217.46 01


[-] Buildingwise Floor FAR Details
Floor Name Building Name Total
A (BUILDING )
Proposed Built Up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Total Proposed Built Up Area (Sq.mt.) Total FAR Area (Sq.mt.)
Ground Floor 121.83 107.62 121.83 107.62
First Floor 109.84 109.84 109.84 109.84
Terrace Floor 0.00 0.00 0.00 0.00
Total : 231.67 217.46 231.67 217.46


[-] UnitBUA Table for Building :A (BUILDING )
UnitBUA CALCULATION
FLOOR Name UnitBUA Type UnitBUA Area Carpet Area No. of Rooms No. of Tenement
GROUND FLOOR PLAN SPLIT A FLAT 196.60 196.23 8 1
FIRST FLOOR PLAN SPLIT A FLAT 0.00 0.00 8 0
Total: - - 196.60 196.23 16 1


[-] Building :A (BUILDING )
Floor Name Total Built Up Area (Sq.mt.) Deductions (Area in Sq.mt.) Proposed FAR Area (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
Parking Resi.
Ground Floor 121.83 14.21 107.62 107.62 107.62 01
First Floor 109.84 0.00 109.84 109.84 109.84 00
Terrace Floor 0.00 0.00 0.00 0.00 0.00 00
Total : 231.67 14.21 217.46 217.46 217.46 01
Total Number of Same Buildings : 1
Total : 231.67 14.21 217.46 217.46 217.46 01
[-] Table 4c-2

  FAR Area
Building FAR Area:217.47
Existing FAR Area :0.00
Perm.
348.43
Prop.
217.47
Status
OK




[-] Margin Checks (Table 5)
   
[-] Plot Margin (Table 5a)
Building / Wing Road Name Front Side Rear Side Side1 Side2 Status
Reqd. Prop. Reqd. Prop. Reqd. Prop. Reqd. Prop.
A-1 (BUILDING ) 3.04 MTR MAIN ROAD 2.50 6.73 1.50 1.80 0.90 0.90 0.90 1.03 OK






[-] Inner Building Details (Table 6)
   

No OTS/Duct/VShaft/Balcony/Passage/Lift/Tenements Found.
   


[-] Parking Details (Table 7)
   

NO PARKING CHECK REQUIRED FOR SINGLE DWELLING UNIT. Bungalow/ Dwelling / Non Apartment, In Building: A (BUILDING )
   


[-] Exemption Details (Table 8)
   


Not Required to Check StairCase Number Rule.


[-] Staircase Checks (Table 8a-1)


[-] For Building :A (BUILDING )
Floor Name StairCase Name Flight Width Tread Width Riser Height Riser No. On Flight Cabin Ht. Status
Reqd Prop Reqd Prop Perm Prop Perm Prop Reqd Perm Prop
GROUND FLOOR PLAN STAIRCASE 0.750 1.050 0.225 0.250 0.200 0.150 - 11 - - 0.000 OK
FIRST FLOOR PLAN STAIRCASE 0.750 1.050 0.225 0.250 0.200 0.150 - 11 - - 0.000 OK
TERRACE FLOOR PLAN STAIRCASE - 1.050 - 0.250 - 0.000 - 0 2.100 - 2.300 OK

   
   
   
[-] Accessory Use Check (Table 8d)
Accessory Use Name Area Width Depth Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
SUMP TANK - - 6.79 - - 1.87 - - 3.64 - - 0.00 OK
RAIN WATER HARVESTING - - 7.31 - - 1.87 - - 3.91 - - 0.00 OK
Overhead WaterTank - - 2.98 - - 1.39 - - 2.15 - - 0.00 OK
ENT.GATE - - 1.50 - - 0.55 - - 2.87 - - 0.00 OK





[-] Accessory Use No. Checks
Building Name Accessory Use Name No Status
Reqd Perm Prop
A (BUILDING ) Rain Water Harvesting 1 - 1 OK
   
   


[-] Floor Details (Table 9)
   

[-] Building:A (BUILDING )


[-] Floor:GROUND FLOOR PLAN



All Dimensions and Area of all the Rooms on this Floor are as per the Rules.

[-] Floor:FIRST FLOOR PLAN



Not Required to Check Dimensions and Area of all the Rooms on this Floor Rule.


   


[-] Summary (Table 10)
   
Name Perm./Reqd. Proposed Status
  Plot Area - 290.36 OK
  Plot Width - 14.17 OK
  Plot Depth - 20.49 OK
  Access Width - 3.04 OK
  Plot Frontage - 13.20 OK
  Coverage Area 174.22 121.83 OK
  FAR Area
Bldg. FAR Area : 217.47
Sanctioned FAR Area :0.00
348.43 217.47 OK





[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Width No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Depth No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Access Width The minimum width of abutting road for any Building shall be with respect to Length of Road {As per Rule No. 34 Table No.6}
Plot Frontage No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
FAR Area (1) In New Area, FAR for plot which lies on road less than 6.10 m. the width shall be taken as incase of Old Area {As per Addendum from Govt. of Jharkhand 3141 dated 15/05/2017}
(2) For Lohardaga Nagar Parishad Max. 2.0 permissible FAR may be permitted for Residential Use {As per Annexure III}
Consumed FAR (1) In New Area, FAR for plot which lies on road less than 6.10 m. the width shall be taken as incase of Old Area {As per Addendum from Govt. of Jharkhand 3141 dated 15/05/2017}
(2) For Lohardaga Nagar Parishad Max. 2.0 permissible FAR may be permitted for Residential Use {As per Annexure III}
Common Plot Area In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
Common Plot (1) In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
(2) ;
Tree Number 4-8 Trees shall be required for the Plot area above 250.0 and upto 1000.0 sq.mt. (As per Rule No. 20.1.6)
Margin Rule For Non-highrise Residential Building upto 10.0 mt. Ht. having Plot Depth 15-21 mt. and Plot width 10-15 mt., Margin required in Front shall be 2.5 mt., Rear 1.5 mt. and 0.9 mt. shall be provided on both side. {As per Rule No. 36 (Table 8 & 9)}
Building Level
Building Height In New Area, for plot which lies on road less than 6.10 m. Perm. Building Ht. shall be taken as incase of Old Area {As per Addendum from Govt. of Jharkhand 3141 dated 15/05/2017}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(3) The plinth or any part of a building shall be so located with respect to the surrounding ground level that adequate drainage of the site is assured. The height of the plinth (except in case of stilted parking) shall be not less than 0.45 mt. from the surrounding ground level {As per Rule No. 42.10}
Parapet Height (1) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
(2) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
(3) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
Floor Number In New Area, for plot which lies on road less than 6.10 m. Perm. No of Floor shall be taken as incase of Old Area {As per Addendum from Govt. of Jharkhand 3141 dated 15/05/2017}
StairCase (1) Width of Winding staircase shall be mini. 0.75 mt.,Maximum rise 0.20 mt. & Minimum tread 0.225 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) Width of Winding staircase shall be mini. 0.75 mt.,Maximum rise 0.20 mt. & Minimum tread 0.225 mt. & Cabin height 2.1 mt {As per Rule No. 83.18}
(4) ; No Rule Defined
Plot / Building Level
Accessory Use (1) -
(2) No need to check distance from Building SUMP TANK
(3) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(4) No need to check distance from Building RAIN WATER HARVESTING
(5) -
(6) No need to check distance from Building Overhead WaterTank
(7) No need to check distance from Building ENT.GATE
Accessory Use Number Provision of Rain Water Harvesting shall be mandatory for any use {Updated as per JBBL, Amendment VIII dated 16/03/2021} Rain Water Harvesting
Building Level (Rooms)