No Image Found   

Detail Scrutiny Report

Lohardaga Nagar Parishad

Version Number: 1.0.70  
Version Date: 16/10/2020 
Report Generated On: 04-07-2024 
 
[-] Collapse All


General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictLOHARDAGA
AuthorityLOHARDAGA NAGAR PARISHAD
Inward_NoLNP/BP/0050/W14/2024
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentNew
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillageLohardaga
Taluka26
Architect Details
Architect NameASHWINI KUMAR SAHU
License No.LNP/ENG/0005/2017
Architect AddressNear check post, PWD Road
Architect EmailIDerashwinisahu@gmail.com
Architect Mobile No9308730823
Plot Details
Plot Use Residential
Plot SubUse Bungalow/ Dwelling / Non Apartment
PlotNearbyReligiousStructure NA
Plot/SubPlot No490/2358/782
North -
South -
East -
WestRoad Width - 12
Owner's Details
NameARUN KUMAR AGRAWAL
AddressNEW ROAD LOHARDAGA NEAR V MART MALL
Email IDSOALOHARDAGA@GMAIL.COM
Mobile No9334432499
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 111.96
2 Plot area as per Document by Applicant 111.96
3 Physical area measured at site 111.96
4 Area as per Site Visit (Site Visit Report) 111.96
5Area as per Drawing 111.96

Area of Plot Considered : 111.96

[-] Table 2b
Proposal Detail :
UnitMeters
Development Detail :
PlotPLOT
Plot OccupancyResidential
Plot SubUse Bungalow/ Dwelling / Non Apartment
Building StructureNon-Highrise
Building TypeSingle Detached House
Gross Plot Area 111.96
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 111.96
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 94.18
Deductions for Balance Plot Area (from Gross Plot Area)
- Common Plot 17.77
17.77
Balance Plot Area 94.18

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 70.00 % ) 78.37
Proposed Coverage Area ( 58.41 % ) 65.39
Total Prop. Coverage Area ( 58.41 % ) 65.39
Balance coverage area ( 11.59 % ) 12.98
FAR CHECK
Perm. FAR Area ( 2.000 ) 223.92
Total Perm. FAR area 223.92
Residential FAR 124.00
Proposed FAR Area 135.86
Total Proposed FAR Area 135.86
Consumed FAR (Factor) 1.21
Balance FAR Area 88.06
BUA CHECK
Total Proposed BuiltUp Area 196.16


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Up to 50 meter -
Existing Road Width 12 12.00
Proposed Road Width as per Master Plan 12 -
Road Widening Width 0 -
Plot size (as per measurement) 111.96 111.96
[-] Extra Land Area Checks
Name Area Status
Reqd Prop
Extra Land - 0.00 OK


[-] Plot Level Checking (Table 3)
   
[-] Common Plot Checks (Table 3b)
Name Total Area Status
Reqd Prop
Common Plot 5.60 17.77 OK


[-] Common Plot Checks (Table 3b)
Name Minimum Area Coverage Area Width Angle Access Status
Reqd Prop Perm Prop Reqd Prop Reqd Prop
Tree Cover (Plantation) - 17.77 0.00 0.00 - 2.12 - 84.97 No Access Provided OK


   
   
[-] Tree Details (Table 3g)
Name Nos Of Trees Status
Reqd Prop
Tree 2 10 OK
   
   
   
   
   


[-] Building Details (Table 4)
   
[-] Building USE/SUBUSE Details Building USE/SUBUSE Details
Building Name Building Use Building SubUse Building Structure
A (ARUN KUMAR AGRAWAL) Residential Bungalow/ Dwelling / Non Apartment Non-Highrise
   
   
   
[-] Height Details (4a)



[-] Total Height (Table 4a-1)
Building Height Height (From GL) Height (From Street LVL) Status
Perm Prop
A (ARUN KUMAR AGRAWAL) 20.10 9.14 9.14 9.14 OK


   
   
[-] Floor Height Check (Table 4a-2)
Building Name Floor Name Height Clear Height Beam Clear Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
A (ARUN KUMAR AGRAWAL) Second Floor 2.75 - 3.05 2.75 - 2.95 2.40 - 2.74 OK
First Floor 2.75 - 3.05 2.75 - 2.95 2.40 - 2.74 OK
Ground Floor 2.75 - 3.05 2.75 - 2.95 2.40 - 2.74 OK
Plinth 0.45 - 0.46 - - 0.46 - - 0.46 OK


[-] Parapet Height Check (Table 4a-2.1)
Building Name Floor Name Height Clear Height Beam Clear Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
A (ARUN KUMAR AGRAWAL) Terrace Floor - - 1.03 - - 1.03 - - 1.03 OK
   
   
   
[-] Floor Number Check (Table 4a-4)
Building Name No. of Floors No. of Tenements Status
Perm Prop Perm Prop
A (ARUN KUMAR AGRAWAL) G + 6 3 - 1 OK

 
   
    [-] Coverage Check (Table 4b)
Permissible Proposed Status
78.37 65.39 OK
70% 58.41%

[-] Individual Coverage Check
Coverage Area Perm. Prop.
  A-1 (ARUN KUMAR AGRAWAL) - 65.39
  Total Prop. Coverage Area - 65.39
  Total Coverage Area 78.37 65.39

[-] FAR & Tenement Details (Table 4c-1)
Building No. of Same Bldg Total Built Up Area (Sq.mt.) Deductions (Area in Sq.mt.) Proposed FAR Area (Sq.mt.) Add Area In FAR (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
Lift Parking Resi. Stair
A (ARUN KUMAR AGRAWAL) 1 196.16 6.78 53.53 124.00 8.47 135.85 135.85 01
Grand Total : 1 196.16 6.78 53.53 124.00 8.47 135.85 135.85 01


[-] Buildingwise Floor FAR Details
Floor Name Building Name Total
A (ARUN KUMAR AGRAWAL)
Proposed Built Up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Total Proposed Built Up Area (Sq.mt.) Total FAR Area (Sq.mt.)
Ground Floor 65.38 11.85 65.38 11.85
First Floor 65.39 62.00 65.39 62.00
Second Floor 65.39 62.00 65.39 62.00
Terrace Floor 0.00 0.00 0.00 0.00
Total : 196.16 135.85 196.16 135.85


[-] UnitBUA Table for Building :A (ARUN KUMAR AGRAWAL)
UnitBUA CALCULATION
FLOOR Name UnitBUA Type UnitBUA Area Carpet Area No. of Rooms No. of Tenement
FIRST FLOOR PLAN SPLIT A FLAT 93.44 92.87 5 1
SECOND FLOOR PLAN SPLIT A FLAT 0.00 0.00 5 0
Total: - - 93.44 92.87 10 1


[-] Building :A (ARUN KUMAR AGRAWAL)
Floor Name Total Built Up Area (Sq.mt.) Deductions (Area in Sq.mt.) Proposed FAR Area (Sq.mt.) Add Area In FAR (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
Lift Parking Resi. Stair
Ground Floor 65.38 0.00 53.53 0.00 8.47 11.85 11.85 00
First Floor 65.39 3.39 0.00 62.00 0.00 62.00 62.00 01
Second Floor 65.39 3.39 0.00 62.00 0.00 62.00 62.00 00
Terrace Floor 0.00 0.00 0.00 0.00 0.00 0.00 0.00 00
Total : 196.16 6.78 53.53 124.00 8.47 135.85 135.85 01
Total Number of Same Buildings : 1
Total : 196.16 6.78 53.53 124.00 8.47 135.85 135.85 01
[-] Table 4c-2

  FAR Area
Building FAR Area:135.86
Existing FAR Area :0.00
Perm.
223.92
Prop.
135.86
Status
OK




[-] Margin Checks (Table 5)
   
[-] Plot Margin (Table 5a)
Building / Wing Road Name Front Side Rear Side Side1 Side2 Status
Reqd. Prop. Reqd. Prop. Reqd. Prop. Reqd. Prop.
A-1 (ARUN KUMAR AGRAWAL) 12.0 MTR WIDE MAINROAD 2.00 2.10 1.50 1.52 0.90 0.97 - 0.00 OK






[-] Inner Building Details (Table 6)
   
   
[-] Lift Details (Table 6d)
Building Name Height Number Of Lift(s) Number Of Strature Lift(s) Capacity Of Lift(s) Passanger Status
Prop Reqd Prop Reqd Prop Reqd Prop
A (ARUN KUMAR AGRAWAL) 9.14 - 1 - 0 - 6 OK

[-] Lift Check Table

[-] For Building :A (ARUN KUMAR AGRAWAL)
Floor Name Lift Name Width Depth Status
Reqd Prop Reqd Prop
GROUND FLOOR PLAN Lift 1.70 1.78 1.90 1.91 OK
FIRST FLOOR PLAN Lift 1.70 1.78 1.90 1.91 OK
TERRACE FLOOR PLAN Lift Machine Room 1.70 1.78 1.90 1.91 OK
SECOND FLOOR PLAN Lift 1.70 1.78 1.90 1.91 OK

   


[-] Parking Details (Table 7)
   

NO PARKING CHECK REQUIRED FOR SINGLE DWELLING UNIT. Bungalow/ Dwelling / Non Apartment, In Building: A (ARUN KUMAR AGRAWAL)
   


[-] Exemption Details (Table 8)
   


Not Required to Check StairCase Number Rule.


[-] Staircase Checks (Table 8a-1)


[-] For Building :A (ARUN KUMAR AGRAWAL)
Floor Name StairCase Name Flight Width Tread Width Riser Height Riser No. On Flight Cabin Ht. Status
Reqd Prop Reqd Prop Perm Prop Perm Prop Reqd Perm Prop
GROUND FLOOR PLAN STAIRCASE 0.900 0.876 0.250 0.254 0.200 0.145 - 11 - - 0.000 Failed
FIRST FLOOR PLAN STAIRCASE 0.900 0.876 0.250 0.254 0.200 0.145 - 11 - - 0.000 Failed
TERRACE FLOOR PLAN STAIRCASE - 0.876 - 0.254 - 0.000 - 0 - - 2.591 OK
SECOND FLOOR PLAN STAIRCASE 0.900 0.876 0.250 0.254 0.200 0.145 - 11 - - 0.000 Failed

   
   
   

[-] Ramp Checks (Table 8b-a)
Ramp Name Width Depth Slope Status
Reqd Prop Reqd Prop Reqd Perm Prop
0.75 mt. long 0.15 mt. High 2.68 mt. Wide Natural Slope - 0.75 - 0.15 - - - OK


[-] Ramp Checks (Table 8b)
Building Name Floor Name No. Status
Reqd Prop
A (ARUN KUMAR AGRAWAL) GROUND FLOOR PLAN - 1 OK

   
   
   
[-] Accessory Use Check (Table 8d)
Accessory Use Name Area Width Depth Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
SewageTreatment Plant - - 1.07 - - 0.83 - - 1.29 - - 0.00 OK
RAINWATERHARVESTING - - 1.29 - - 1.04 - - 1.24 - - 0.00 OK
ENT.GATE - - 1.04 - - 0.43 - - 2.43 - - 0.00 OK
SOLARHEATINGSYSTEM - - 1.33 - - 1.07 - - 1.25 - - 0.00 OK





[-] Accessory Use No. Checks
Building Name Accessory Use Name No Status
Reqd Perm Prop
A (ARUN KUMAR AGRAWAL) Rain Water Harvesting 1 - 1 OK
   
   


[-] Floor Details (Table 9)
   

[-] Building:A (ARUN KUMAR AGRAWAL)


[-] Floor:GROUND FLOOR PLAN



No Room Found.


[-] Floor:FIRST FLOOR PLAN



All Dimensions and Area of all the Rooms on this Floor are as per the Rules.

[-] Floor:SECOND FLOOR PLAN



Not Required to Check Dimensions and Area of all the Rooms on this Floor Rule.


   


[-] Summary (Table 10)
   
Name Perm./Reqd. Proposed Status
  Plot Area - 111.96 OK
  Plot Width - 8.69 OK
  Plot Depth - 12.89 OK
  Access Width - 12.00 OK
  Plot Frontage - 8.84 OK
  Coverage Area 78.37 65.39 OK
  FAR Area
Bldg. FAR Area : 135.86
Sanctioned FAR Area :0.00
223.92 135.86 OK





[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Width No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Depth No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Access Width The minimum width of abutting road for any Building shall be with respect to Length of Road {As per Rule No. 34 Table No.6}
Plot Frontage No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
FAR Area (1) In Old Area, for Residential Building on abutting roadwidth 9.10 (30 ft.) to 12.20 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15}
(2) For Lohardaga Nagar Parishad Max. 2.0 permissible FAR may be permitted for Residential Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Residential Building on abutting roadwidth 9.10 (30 ft.) to 12.20 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15}
(2) For Lohardaga Nagar Parishad Max. 2.0 permissible FAR may be permitted for Residential Use {As per Annexure III}
Common Plot Area In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
Common Plot (1) In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
(2) ;
Tree Number 2-4 Trees shall be required for the Plot area upto 250.0 sq.mt. (As per Rule No. 20.1.6)
Margin Rule For Non-highrise Residential Building upto 10.0 mt. Ht. having Plot Depth 10-15 mt. and Plot width 10-15 mt., Margin required in Front shall be 2.0 mt., Rear 1.5 mt. and Atleast 0.9 mt. shall be provided at one side. {As per Rule No. 36 (Table 8 & 9)}
Building Level
Building Height For old area, on Road width 9.10-12.20 mt., Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 23.10 mt. {As per Rule No. 39.1 Table 15}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(3) The plinth or any part of a building shall be so located with respect to the surrounding ground level that adequate drainage of the site is assured. The height of the plinth (except in case of stilted parking) shall be not less than 0.45 mt. from the surrounding ground level {As per Rule No. 42.10}
Parapet Height (1) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
(2) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
(3) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
Floor Number For old area location,on Road width 9.1-12.20 mt. only G+6 floors shall be allowed {As per Rule No. 39.1 Table 15}
Lift Count (1) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(2) For Residential Building height upto 15.0 mt or upto G+4 floors, No Lift is reqd. {As per Amended 06-06-2019 Rule No. 49.1.1}
Lift (1) The area of lift well at one floor only (not the sum of total area of lift well at every floor) shall be counted for F.A.R calculation)
(2) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(3) The area of lift well shall not be counted for F.A.R calculation)
(4) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(5) -
StairCase (1) Width of Winding staircase shall be mini. 0.90 mt.,Maximum rise 0.20 mt. & Minimum tread 0.25 mt. & Cabin Height 2.1 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) No Rule Defined
(4) ; No Rule Defined
Ramp No Need to Check Natural Slope width, Depth or height. ;
Ramp No. -
Plot / Building Level
Accessory Use (1) -
(2) No need to check distance from Building SewageTreatment Plant
(3) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(4) No need to check distance from Building RAINWATERHARVESTING
(5) No need to check distance from Building ENT.GATE
(6) -
(7) No need to check distance from Building SOLARHEATINGSYSTEM
Accessory Use Number Provision of Rain Water Harvesting shall be mandatory for any use {Updated as per JBBL, Amendment VIII dated 16/03/2021} Rain Water Harvesting
Building Level (Rooms)
Bed Room3.99x3.05 The area of habitable room shall not be less than 9.5 m2, where there is only one room with a minimum width of 2.4 m. Where there are two rooms, one of these shall not be less than 9.5 m2 and the other not less than 7.5 m2, with a minimum width of 2.1 mt.
Hall3.68x4.77 No Rule Defined
Kitchen3.07x2.13 Area for Kitchen shall be Mini. 5.0 sq.mt. having side mini. 1.8 mt. {Rule No. 42.3.2}
Sitout5.15x1.07 No Rule Defined
Toilet1.22x2.94 Area for Toilet shall be Mini. 2.8 sq.mt. having side mini. 1.2 mt. {Rule No. 42.4.2}