No Image Found   

Check List Report

Lohardaga Nagar Parishad

Version Number: 1.0.66  
Version Date: 16/10/2020 
Report Generated On: 24-07-2023 
 

[-] Collapse All


General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictLOHARDAGA
AuthorityLOHARDAGA NAGAR PARISHAD
Inward_NoLNP/BP/0022/W15/2023
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentNew
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillageLohardaga
Taluka26
Architect Details
Architect NameASHWINI KUMAR SAHU
License No.LNP/ENG/0005/2017
Architect AddressNear check post, PWD Road
Architect EmailIDerashwinisahu@gmail.com
Architect Mobile No9308730823
Plot Details
Plot Use Residential
Plot SubUse Bungalow/ Dwelling / Non Apartment
PlotNearbyReligiousStructure NA
Plot/SubPlot No490/2326/911
NorthPlot No. - 911
SouthRoad Width - 4.57
EastPlot No. - 911
WestPlot No. - 911
Owner's Details
NameUSHA DEVI
AddressNEAR KASTURBA SCHOOL LOHARDAGA
Email IDSOALOHARDAGA@GMAIL.COM
Mobile No9199964801
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Plot area as per Document by Applicant 146.16
2 Physical area measured at site 146.16
3 Area as per Site Visit (Site Visit Report) 146.16
4Area as per Drawing 146.08

Area of Plot Considered : 146.08

[-] Table 2b
Proposal Detail :
Unit
Development Detail :
PlotPLOT
Plot OccupancyResidential
Plot SubUse Bungalow/ Dwelling / Non Apartment
Building StructureNon-Highrise
Building TypeSingle Detached House
Gross Plot Area 146.08
Deduction from Gross Plot area
- Surrender Free of Cost 6.36
6.36
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 139.72
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 123.68
Deductions for Balance Plot Area (from Gross Plot Area)
- Surrender Free of Cost 6.36
- Common Plot 16.03
22.39
Balance Plot Area 123.68

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 70.00 % ) 97.80
Proposed Coverage Area ( 67.34 % ) 94.09
Total Prop. Coverage Area ( 67.34 % ) 94.09
Balance coverage area ( 2.66 % ) 3.71
FAR CHECK
Perm. FAR Area ( 1.500 ) 219.12
Total Perm. FAR area 219.12
Residential FAR 187.48
Proposed FAR Area 201.01
Total Proposed FAR Area 201.01
Consumed FAR (Factor) 1.38
Balance FAR Area 18.11
BUA CHECK
Total Proposed BuiltUp Area 284.75


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Exceeding 100 meter and upto 250 meter -
Existing Road Width 4.57 4.57
Proposed Road Width as per Master Plan 4.57 -
Road Widening Width 0 0.80
Plot size (as per measurement) 146.16 146.08

     Plot Related Details
Name Description Unit Reqd Perm Proposed Status
PLOT Plot Area Sq.Mt. - - 139.72 OK
Plot Width Mt. - - 7.98 OK
Plot Depth Mt. - - 17.52 OK
Access Width Mt. - - 4.57 OK
Plot Frontage Mt. - - 7.95 OK
Coverage Area Sq.Mt. - 97.80 94.09 OK
FAR Area Sq.Mt. - 219.12 201.01 OK
Consumed FAR Sq.Mt. - 1.50 1.38 OK
Common Plot Checks Common Plot - Total Area Sq.Mt. 6.99 16.03 OK
Common Plot Tree Cover (Plantation) - Minimum Area Sq.Mt. - 16.03 OK
Tree Cover (Plantation) - Coverage Area Sq.Mt. - - OK
Tree Cover (Plantation) - Width Mt. - 1.99 OK
Tree Cover (Plantation) - Angle Degree - 89.45 OK
Tree Cover (Plantation) - Access Mt. - OK
Tree Tree - Nos Of Trees No. 2 9 OK
A-1 (MRS USHA DEVI) Front Margin... ROAD WIDENING AREA(SURRENDERED FREE OF COST) Mt. 2.50 - 2.58 OK
Rear Margin Mt. 1.50 - 1.53 OK
Side1 Margin Mt. 0.90 - 0.92 OK
Side2 Margin Mt. - - 0.00 OK
A-1 (MRS USHA DEVI) BldgLine for 4.57 MTR WIDE MAINROAD Mt. 0.76 3.38 OK
A-1 (MRS USHA DEVI) ResvRoad Width Check for... 4.57 MTR WIDE MAINROAD Mt. 0.76 0.80 OK

     Building Related Details
Name Description Unit Reqd Perm Proposed Status
A (MRS USHA DEVI) Height Mt. 10.00 9.53 OK
A (MRS USHA DEVI) Second Floor - Height Mt. 2.75 - 3.18 OK
Second Floor - Clear Height Mt. 2.75 - 3.08 OK
Second Floor - Beam Clear Height Mt. 2.40 - 2.94 OK
First Floor - Height Mt. 2.75 - 3.18 OK
First Floor - Clear Height Mt. 2.75 - 3.08 OK
First Floor - Beam Clear Height Mt. 2.40 - 2.94 OK
Ground Floor - Height Mt. 2.75 - 3.18 OK
Ground Floor - Clear Height Mt. 2.75 - 3.08 OK
Ground Floor - Beam Clear Height Mt. 2.40 - 2.94 OK
Plinth - Height Mt. 0.45 - 0.61 OK
Plinth - Clear Height Mt. - - 0.61 OK
Plinth - Beam Clear Height Mt. - - 0.61 OK
A (MRS USHA DEVI) Terrace Floor - Height Mt. - - 1.01 OK
Terrace Floor - Clear Height Mt. - - 1.01 OK
Terrace Floor - Beam Clear Height Mt. - - 1.01 OK
A (MRS USHA DEVI) No. of Floors No. G + 2 3 OK
No. of Tenements No. - 1 OK
A (MRS USHA DEVI) SECOND FLOOR PLAN - BALCONY - Width Mt. 1.20 0.90 OK
TERRACE FLOOR PLAN Staircase -3FL - Flight Width Mt. - 0.991 OK
Staircase -3FL - Tread Width Mt. - 0.254 OK
Staircase -3FL - Riser Height Mt. - - OK
Staircase -3FL - Riser No. On Flight No. - - OK
Staircase -3FL - Cabin Ht. Mt. - - 2.591 OK
SECOND FLOOR PLAN Staircase -3FL - Flight Width Mt. 0.900 0.991 OK
Staircase -3FL - Tread Width Mt. 0.250 0.254 OK
Staircase -3FL - Riser Height Mt. 0.200 0.086 OK
Staircase -3FL - Riser No. On Flight No. - 9 OK
Staircase -3FL - Cabin Ht. Mt. - - - OK
FIRST FLOOR PLAN Staircase -3FL - Flight Width Mt. 0.900 0.991 OK
Staircase -3FL - Tread Width Mt. 0.250 0.254 OK
Staircase -3FL - Riser Height Mt. 0.200 0.086 OK
Staircase -3FL - Riser No. On Flight No. - 9 OK
Staircase -3FL - Cabin Ht. Mt. - - - OK
GROUND FLOOR PLAN Staircase -3FL - Flight Width Mt. 0.900 0.991 OK
Staircase -3FL - Tread Width Mt. 0.250 0.254 OK
Staircase -3FL - Riser Height Mt. 0.200 0.086 OK
Staircase -3FL - Riser No. On Flight No. - 9 OK
Staircase -3FL - Cabin Ht. Mt. - - - OK
Toilet Area Sq.Mt. - 5.00 3.72 OK
Width Mt. - - 1.22 OK
Depth Mt. - - 3.05 OK
Height Mt. - - - OK
Sewage Treatment Plant Area Sq.Mt. - - 0.43 OK
Width Mt. - - 0.53 OK
Depth Mt. - - 0.80 OK
Height Mt. - - - OK
RAIN WATER HARVESTING Area Sq.Mt. - - 0.43 OK
Width Mt. - - 0.53 OK
Depth Mt. - - 0.80 OK
Height Mt. - - - OK
ENT.GATE Area Sq.Mt. - - 0.64 OK
Width Mt. - - 0.41 OK
Depth Mt. - - 1.58 OK
Height Mt. - - - OK
SOLAR HEATING SYSTEM Area Sq.Mt. - - 0.52 OK
Width Mt. - - 0.65 OK
Depth Mt. - - 0.80 OK
Height Mt. - - - OK
A (MRS USHA DEVI) Rain Water Harvesting - No No. 1 - 1 OK
PLOT 1.20 mt. long 0.15 mt. High 3.70 mt. Wide Natural Slope - Width Mt. - 1.20 OK
1.20 mt. long 0.15 mt. High 3.70 mt. Wide Natural Slope - Depth Mt. - 0.15 OK
1.20 mt. long 0.15 mt. High 3.70 mt. Wide Natural Slope - Slope Ratio - - - OK
Ramp No. A (MRS USHA DEVI) - GROUND FLOOR PLAN - No. No. - 1 OK
   
    All Rooms are as per Rule in Room Checking




[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Width No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Depth No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Access Width The minimum width of abutting road for any Building shall be with respect to Length of Road {As per Rule No. 34 Table No.6}
Plot Frontage No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
FAR Area (1) In Old Area, for Residential Building on abutting roadwidth 3.60 (12 ft.) to 4.80 mt., the Floor Area Ratio-FAR shall be 1.5 {As per Rule No.39, Table 15}
(2) For Lohardaga Nagar Parishad Max. 2.0 permissible FAR may be permitted for Residential Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Residential Building on abutting roadwidth 3.60 (12 ft.) to 4.80 mt., the Floor Area Ratio-FAR shall be 1.5 {As per Rule No.39, Table 15}
(2) For Lohardaga Nagar Parishad Max. 2.0 permissible FAR may be permitted for Residential Use {As per Annexure III}
Common Plot Area In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
Common Plot (1) In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
(2) ;
Tree Number 2-4 Trees shall be required for the Plot area upto 250.0 sq.mt. (As per Rule No. 20.1.6)
Margin Rule For Non-highrise Residential Building upto 10.0 mt. Ht. having Plot Depth 15-21 mt. and Plot width 15-21 mt., Margin required in Front shall be 2.5 mt., Rear 1.5 mt. and Atleast 0.9 mt. shall be provided at one side. {As per Rule No. 36 (Table 8 & 9)}
Building Line Check The min. width of Road for length of Road Exceeding 100 mt. and upto 300 mt. shall be 6.1 mt. {As per Rule No. 34 Table No. 6 and as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
ResvRoad Width Check The min. width of Road for length of Road Exceeding 100 mt. and upto 300 mt. shall be 6.1 mt. {As per Rule No. 34 Table No. 6 and as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
Building Level
Building Height For old area, on Road width 3.6-4.8 mt., Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 10.0 mt. {As per Rule No. 39.1 Table 15}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(3) The plinth or any part of a building shall be so located with respect to the surrounding ground level that adequate drainage of the site is assured. The height of the plinth (except in case of stilted parking) shall be not less than 0.45 mt. from the surrounding ground level {As per Rule No. 42.10}
Parapet Height (1) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
(2) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
(3) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
Floor Number For old area location,on Road width 3.6-4.8 mt. only G+2 floors shall be allowed {As per Rule No. 39.1 Table 15}
Balcony Projected balcony may be allowed with a widt of 1.2 mt. where the setback is more than 2.5 mt. {As per Rule No. 46.4 and modified as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
StairCase (1) No Rule Defined
(2) ; No Rule Defined
(3) Width of Winding staircase shall be mini. 0.90 mt.,Maximum rise 0.20 mt. & Minimum tread 0.25 mt. & Cabin Height 2.1 mt. {As per Rule No. 83.18}
(4) ; No Rule Defined
Ramp No Need to Check Natural Slope width, Depth or height. ;
Ramp No. -
Plot / Building Level
Accessory Use (1) Common toilet of maximum size of 5 sq.mt shall be taken Free from FAR
(2) No need to check distance from Building Toilet
(3) -
(4) No need to check distance from Building Sewage Treatment Plant
(5) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(6) No need to check distance from Building RAIN WATER HARVESTING
(7) No need to check distance from Building ENT.GATE
(8) -
(9) No need to check distance from Building SOLAR HEATING SYSTEM
Accessory Use Number Provision of Rain Water Harvesting shall be mandatory for any use {Updated as per JBBL, Amendment VIII dated 16/03/2021} Rain Water Harvesting
Building Level (Rooms)