General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictLOHARDAGA
AuthorityLOHARDAGA NAGAR PARISHAD
Inward_NoLNP/BP/0026/W07/2023
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentAddition or Alteration
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillageNadia
Taluka26
Layout Sanction No13/2010
Layout Sanction Date7/6/2012
Architect Details
Architect NameASHWINI KUMAR SAHU
License No.LNP/ENG/0005/2017
Architect AddressNear check post, PWD Road
Architect EmailIDerashwinisahu@gmail.com
Architect Mobile No9308730823
Plot Details
Plot Use Residential
Plot SubUse ResiComm Bldg
PlotNearbyReligiousStructure NA
Plot/SubPlot No258 & 259
NorthRoad Width - 10.0 MTR WIDE MAIN ROAD
South -
East -
West -
Owner's Details
NameHINDALCO INDUSTRIES LIMITED MINES DIVISION
AddressCOURT ROAD LOHARDAGA
Email IDSOALOHARDAGA@GMAIL.COM
Mobile No8789099677
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 12251.29
2 Plot area as per Document by Applicant 12251.29
3 Physical area measured at site 12251.29
4 Area as per Site Visit (Site Visit Report) 12251.29
5Area as per Drawing 12251.29

Area of Plot Considered : 12251.29

[-] Table 2b
Proposal Detail :
Unit
Development Detail :
PlotPLOT
Plot OccupancyResidential
Plot SubUse ResiComm Bldg
Building StructureNon-Highrise
Building TypeSingle Detached House
Gross Plot Area 12251.29
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 12251.29
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 10104.02
Deductions for Balance Plot Area (from Gross Plot Area)
- Common Plot 2147.27
2147.27
Balance Plot Area 10104.02

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 50.00 % ) 6125.65
Proposed Coverage Area ( 12.58 % ) 1540.64
Total Prop. Coverage Area ( 12.58 % ) 1540.64
Balance coverage area ( 37.42 % ) 4585.01
FAR CHECK
Perm. FAR Area ( 2.000 ) 24502.58
Total Perm. FAR area 24502.58
Residential FAR 4600.25
Commercial FAR 1029.98
Proposed FAR Area 5690.68
Total Proposed FAR Area 5690.68
Consumed FAR (Factor) 0.46
Balance FAR Area 18811.90
BUA CHECK
Total Proposed BuiltUp Area 6848.69


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Up to 50 meter -
Existing Road Width 10 10.00
Proposed Road Width as per Master Plan 10 -
Road Widening Width 0 -
Plot size (as per measurement) 12251.29 12251.29
[-] Extra Land Area Checks
Name Area Status
Reqd Prop
Extra Land - 0.00 OK

     Extra Land Area Details
Name Description Unit Reqd Perm Proposed Status
Extra Land Area Details Extra Land Area - - 0.00 OK

     Plot Related Details
Name Description Unit Reqd Perm Proposed Status
PLOT Plot Area Sq.Mt. - - 12251.29 OK
Plot Width Mt. - - 69.59 OK
Plot Depth Mt. - - 176.05 OK
Access Width Mt. 6.10 - 10.00 OK
Plot Frontage Mt. - - 51.90 OK
Coverage Area Sq.Mt. - 6125.65 1540.64 OK
FAR Area Sq.Mt. - 24502.58 5690.68 OK
Consumed FAR Sq.Mt. - 2.00 0.46 OK
Common Plot Checks Common Plot - Total Area Sq.Mt. 1225.13 2147.27 OK
Common Plot Tree Cover (Plantation) - Minimum Area Sq.Mt. - 2147.27 OK
Tree Cover (Plantation) - Coverage Area Sq.Mt. - - OK
Tree Cover (Plantation) - Width Mt. - 23.22 OK
Tree Cover (Plantation) - Angle Degree - 57.96 OK
Tree Cover (Plantation) - Access Mt. - OK
Tree Tree - Nos Of Trees No. 8 19 OK
Car In Area Sq.Mt. - - 900.00 OK
Total Car In Area Sq.Mt. 275.00 - 900.00 OK
Visitor's Car Parking In Area Sq.Mt. - - 87.50 OK
Total Visitor Parking In Area Sq.Mt. 37.50 - 87.50 OK
TwoWheeler In Area Sq.Mt. - - 146.00 OK
Total TwoWheeler In Area Sq.Mt. 100.00 - 146.00 OK
Other Parking In Area Sq.Mt. - - 946.96 OK
DriveWay PLOT - - - DRIVEWAY - Width No. 4.50 - 4.60 OK
C (SQUARE BUILDING BLOCK A) - GROUND FLOOR PLAN - DRIVEWAY - Width No. 4.50 - 5.29 OK
C (SQUARE BUILDING BLOCK A) - GROUND FLOOR PLAN - DRIVEWAY - Width No. 4.50 - 5.29 OK
C (SQUARE BUILDING BLOCK A) - GROUND FLOOR PLAN - DRIVEWAY - Width No. 3.00 - 5.00 OK
C-1 (SQUARE BUILDING BLOCK A) Front Margin... 10.0 MTR WIDE MAINROAD Mt. 6.00 - 68.77 OK
Rear Margin Mt. 5.00 - 35.08 OK
Side1 Margin Mt. 5.00 - 8.72 OK
Side2 Margin Mt. 5.00 - 39.86 OK
D-1 (CLUB HOUSE) Front Margin... 10.0 MTR WIDE MAINROAD Mt. 9.00 - 67.99 OK
Rear Margin Mt. 6.00 - 84.26 OK
Side1 Margin Mt. 6.00 - 6.45 OK
Side2 Margin Mt. 6.00 - 62.86 OK
A-1 (BLOCK 1) Front Margin... 10.0 MTR WIDE MAINROAD Mt. 6.00 - 43.67 OK
Rear Margin Mt. 5.00 - 28.30 OK
Side1 Margin Mt. 5.00 - 55.99 OK
Side2 Margin Mt. 5.00 - 6.56 OK
2-1 (BLOCK 2) Front Margin... 10.0 MTR WIDE MAINROAD Mt. 6.00 - 75.26 OK
Rear Margin Mt. 5.00 - 6.67 OK
Side1 Margin Mt. 5.00 - 32.69 OK
Side2 Margin Mt. 5.00 - 32.32 OK
C-1 (SQUARE BUILDING BLOCK A) D-1 (CLUB HOUSE) - Margin Mt. 7.50 26.21 OK
2-1 (BLOCK 2) - Margin Mt. 7.50 10.04 OK
A-1 (BLOCK 1) - Margin Mt. 7.50 23.94 OK
D-1 (CLUB HOUSE) 2-1 (BLOCK 2) - Margin Mt. 7.50 63.53 OK
C-1 (SQUARE BUILDING BLOCK A) - Margin Mt. 7.50 26.21 OK
A-1 (BLOCK 1) - Margin Mt. 7.50 61.89 OK
A-1 (BLOCK 1) D-1 (CLUB HOUSE) - Margin Mt. 7.50 61.89 OK
2-1 (BLOCK 2) - Margin Mt. 7.50 10.81 OK
C-1 (SQUARE BUILDING BLOCK A) - Margin Mt. 7.50 23.94 OK
2-1 (BLOCK 2) D-1 (CLUB HOUSE) - Margin Mt. 7.50 63.53 OK
C-1 (SQUARE BUILDING BLOCK A) - Margin Mt. 7.50 10.04 OK
A-1 (BLOCK 1) - Margin Mt. 7.50 10.81 OK

     Building Related Details
Name Description Unit Reqd Perm Proposed Status
C (SQUARE BUILDING BLOCK A) Height Mt. 23.10 15.00 OK
D (CLUB HOUSE) Height Mt. 23.10 9.28 OK
A (BLOCK 1) Height Mt. 23.10 15.00 OK
2 (BLOCK 2) Height Mt. 23.10 15.00 OK
C (SQUARE BUILDING BLOCK A) Fourth Floor - Height Mt. 2.75 - 3.00 OK
Fourth Floor - Clear Height Mt. 2.75 - 2.90 OK
Fourth Floor - Beam Clear Height Mt. 2.40 - 2.75 OK
Third Floor - Height Mt. 2.75 - 3.00 OK
Third Floor - Clear Height Mt. 2.75 - 2.90 OK
Third Floor - Beam Clear Height Mt. 2.40 - 2.75 OK
Second Floor - Height Mt. 2.75 - 3.00 OK
Second Floor - Clear Height Mt. 2.75 - 2.90 OK
Second Floor - Beam Clear Height Mt. 2.40 - 2.75 OK
First Floor - Height Mt. 2.75 - 3.00 OK
First Floor - Clear Height Mt. 2.75 - 2.90 OK
First Floor - Beam Clear Height Mt. 2.40 - 2.75 OK
Ground Floor - Height Mt. 2.75 - 3.00 OK
Ground Floor - Clear Height Mt. 2.75 - 2.90 OK
Ground Floor - Beam Clear Height Mt. 2.40 - 2.75 OK
Plinth - Height Mt. 0.45 - 0.45 OK
Plinth - Clear Height Mt. - - 0.45 OK
Plinth - Beam Clear Height Mt. - - 0.45 OK
D (CLUB HOUSE) Second Floor - Height Mt. 2.75 - 3.29 OK
Second Floor - Clear Height Mt. 2.75 - 3.19 OK
Second Floor - Beam Clear Height Mt. 2.40 - 3.04 OK
First Floor - Height Mt. 2.75 - 2.99 OK
First Floor - Clear Height Mt. 2.75 - 2.89 OK
First Floor - Beam Clear Height Mt. 2.40 - 2.74 OK
Ground Floor - Height Mt. 2.75 - 2.99 OK
Ground Floor - Clear Height Mt. 2.75 - 2.89 OK
Ground Floor - Beam Clear Height Mt. 2.40 - 2.74 OK
Plinth - Height Mt. 0.45 - 0.45 OK
Plinth - Clear Height Mt. - - 0.45 OK
Plinth - Beam Clear Height Mt. - - 0.45 OK
A (BLOCK 1) Fourth Floor - Height Mt. 2.75 - 3.00 OK
Fourth Floor - Clear Height Mt. 2.75 - 2.90 OK
Fourth Floor - Beam Clear Height Mt. 2.40 - 2.75 OK
Third Floor - Height Mt. 2.75 - 3.00 OK
Third Floor - Clear Height Mt. 2.75 - 2.90 OK
Third Floor - Beam Clear Height Mt. 2.40 - 2.75 OK
Second Floor - Height Mt. 2.75 - 3.00 OK
Second Floor - Clear Height Mt. 2.75 - 2.90 OK
Second Floor - Beam Clear Height Mt. 2.40 - 2.75 OK
First Floor - Height Mt. 2.75 - 3.00 OK
First Floor - Clear Height Mt. 2.75 - 2.90 OK
First Floor - Beam Clear Height Mt. 2.40 - 2.75 OK
Ground Floor - Height Mt. 2.75 - 3.00 OK
Ground Floor - Clear Height Mt. 2.75 - 2.90 OK
Ground Floor - Beam Clear Height Mt. 2.40 - 2.75 OK
Plinth - Height Mt. 0.45 - 0.45 OK
Plinth - Clear Height Mt. - - 0.45 OK
Plinth - Beam Clear Height Mt. - - 0.45 OK
2 (BLOCK 2) Fourth Floor - Height Mt. 2.75 - 3.00 OK
Fourth Floor - Clear Height Mt. 2.75 - 2.90 OK
Fourth Floor - Beam Clear Height Mt. 2.40 - 2.75 OK
Third Floor - Height Mt. 2.75 - 3.00 OK
Third Floor - Clear Height Mt. 2.75 - 2.90 OK
Third Floor - Beam Clear Height Mt. 2.40 - 2.75 OK
Second Floor - Height Mt. 2.75 - 3.00 OK
Second Floor - Clear Height Mt. 2.75 - 2.90 OK
Second Floor - Beam Clear Height Mt. 2.40 - 2.75 OK
First Floor - Height Mt. 2.75 - 3.00 OK
First Floor - Clear Height Mt. 2.75 - 2.90 OK
First Floor - Beam Clear Height Mt. 2.40 - 2.75 OK
Ground Floor - Height Mt. 2.75 - 3.00 OK
Ground Floor - Clear Height Mt. 2.75 - 2.90 OK
Ground Floor - Beam Clear Height Mt. 2.40 - 2.75 OK
Plinth - Height Mt. 0.45 - 0.45 OK
Plinth - Clear Height Mt. - - 0.45 OK
Plinth - Beam Clear Height Mt. - - 0.45 OK
C (SQUARE BUILDING BLOCK A) Terrace Floor - Height Mt. - - 1.05 OK
Terrace Floor - Clear Height Mt. - - 1.05 OK
Terrace Floor - Beam Clear Height Mt. - - 1.05 OK
D (CLUB HOUSE) Terrace Floor - Height Mt. - - 1.01 OK
Terrace Floor - Clear Height Mt. - - 1.01 OK
Terrace Floor - Beam Clear Height Mt. - - 1.01 OK
A (BLOCK 1) Terrace Floor - Height Mt. - - 1.02 OK
Terrace Floor - Clear Height Mt. - - 1.02 OK
Terrace Floor - Beam Clear Height Mt. - - 1.02 OK
2 (BLOCK 2) Terrace Floor - Height Mt. - - 1.02 OK
Terrace Floor - Clear Height Mt. - - 1.02 OK
Terrace Floor - Beam Clear Height Mt. - - 1.02 OK
C (SQUARE BUILDING BLOCK A) No. of Floors No. G + 6 5 OK
No. of Tenements No. - 3 OK
D (CLUB HOUSE) No. of Floors No. G + 6 3 OK
No. of Tenements No. - 3 OK
A (BLOCK 1) No. of Floors No. G + 6 5 OK
No. of Tenements No. - 3 OK
2 (BLOCK 2) No. of Floors No. G + 6 5 OK
No. of Tenements No. - 3 OK
2 (BLOCK 2) Number Of Lift(s) No. 1 1 OK
Number Of Strature Lift(s) No. - - OK
Capacity Of Lift(s) Passanger No. 6 6 OK
A (BLOCK 1) Number Of Lift(s) No. 1 1 OK
Number Of Strature Lift(s) No. - - OK
Capacity Of Lift(s) Passanger No. 6 6 OK
C (SQUARE BUILDING BLOCK A) Number Of Lift(s) No. 1 1 OK
Number Of Strature Lift(s) No. - - OK
Capacity Of Lift(s) Passanger No. 6 6 OK
D (CLUB HOUSE) Number Of Lift(s) No. - 1 OK
Number Of Strature Lift(s) No. - - OK
Capacity Of Lift(s) Passanger No. - 6 OK
2 (BLOCK 2) TERRACE FLOOR PLAN - Lift Machine Room - Width Mt. 1.70 1.87 OK
TERRACE FLOOR PLAN - Lift Machine Room - Depth Mt. 1.90 1.97 OK
GROUND FLOOR PLAN - Lift - Width Mt. 1.70 1.87 OK
GROUND FLOOR PLAN - Lift - Depth Mt. 1.90 1.97 OK
FOURTH FLOOR PLAN - Lift - Width Mt. 1.70 1.87 OK
FOURTH FLOOR PLAN - Lift - Depth Mt. 1.90 1.97 OK
A (BLOCK 1) TERRACE FLOOR PLAN - Lift Machine Room - Width Mt. 1.70 1.87 OK
TERRACE FLOOR PLAN - Lift Machine Room - Depth Mt. 1.90 1.97 OK
GROUND FLOOR PLAN - Lift - Width Mt. 1.70 1.87 OK
GROUND FLOOR PLAN - Lift - Depth Mt. 1.90 1.97 OK
FOURTH FLOOR PLAN - Lift - Width Mt. 1.70 1.87 OK
FOURTH FLOOR PLAN - Lift - Depth Mt. 1.90 1.97 OK
C (SQUARE BUILDING BLOCK A) GROUND FLOOR PLAN - Lift - Width Mt. 1.70 1.76 OK
GROUND FLOOR PLAN - Lift - Depth Mt. 1.90 2.01 OK
TERRACE FLOOR PLAN - Lift Machine Room - Width Mt. 1.70 1.76 OK
TERRACE FLOOR PLAN - Lift Machine Room - Depth Mt. 1.90 2.01 OK
FOURTH FLOOR PLAN - Lift - Width Mt. 1.70 1.76 OK
FOURTH FLOOR PLAN - Lift - Depth Mt. 1.90 2.01 OK
D (CLUB HOUSE) SECOND FLOOR PLAN - Lift - Width Mt. 1.70 1.99 OK
SECOND FLOOR PLAN - Lift - Depth Mt. 1.90 2.26 OK
FIRST FLOOR PLAN - Lift - Width Mt. 1.70 1.99 OK
FIRST FLOOR PLAN - Lift - Depth Mt. 1.90 2.26 OK
GROUND FLOOR PLAN - Lift - Width Mt. 1.70 1.99 OK
GROUND FLOOR PLAN - Lift - Depth Mt. 1.90 2.26 OK
TERRACE FLOOR PLAN - Lift Machine Room - Width Mt. 1.70 1.99 OK
TERRACE FLOOR PLAN - Lift Machine Room - Depth Mt. 1.90 2.26 OK
TERRACE FLOOR PLAN STAIRCASE - Flight Width Mt. - 1.117 OK
STAIRCASE - Tread Width Mt. - 0.255 OK
STAIRCASE - Riser Height Mt. - - OK
STAIRCASE - Riser No. On Flight No. - - OK
STAIRCASE - Cabin Ht. Mt. - - 2.550 OK
STAIRCASE - Flight Width Mt. - 1.117 OK
STAIRCASE - Tread Width Mt. - 0.255 OK
STAIRCASE - Riser Height Mt. - - OK
STAIRCASE - Riser No. On Flight No. - - OK
STAIRCASE - Cabin Ht. Mt. - - 2.550 OK
STAIRCASE - Flight Width Mt. - 1.132 OK
STAIRCASE - Tread Width Mt. - 0.250 OK
STAIRCASE - Riser Height Mt. - - OK
STAIRCASE - Riser No. On Flight No. - - OK
STAIRCASE - Cabin Ht. Mt. - - 2.550 OK
Staircase -3FL - Flight Width Mt. - 1.205 OK
Staircase -3FL - Tread Width Mt. - 0.250 OK
Staircase -3FL - Riser Height Mt. - - OK
Staircase -3FL - Riser No. On Flight No. - - OK
Staircase -3FL - Cabin Ht. Mt. - - 2.567 OK
GROUND FLOOR PLAN STAIRCASE - Flight Width Mt. 0.900 1.117 OK
STAIRCASE - Tread Width Mt. 0.250 0.255 OK
STAIRCASE - Riser Height Mt. 0.200 0.150 OK
STAIRCASE - Riser No. On Flight No. - 10 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
STAIRCASE - Flight Width Mt. 0.900 1.117 OK
STAIRCASE - Tread Width Mt. 0.250 0.255 OK
STAIRCASE - Riser Height Mt. 0.200 0.150 OK
STAIRCASE - Riser No. On Flight No. - 10 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
STAIRCASE - Flight Width Mt. 0.900 1.132 OK
STAIRCASE - Tread Width Mt. 0.250 0.250 OK
STAIRCASE - Riser Height Mt. 0.200 0.150 OK
STAIRCASE - Riser No. On Flight No. - 10 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
Staircase -3FL - Flight Width Mt. 0.900 1.205 OK
Staircase -3FL - Tread Width Mt. 0.250 0.250 OK
Staircase -3FL - Riser Height Mt. 0.200 0.100 OK
Staircase -3FL - Riser No. On Flight No. - 10 OK
Staircase -3FL - Cabin Ht. Mt. - - - OK
FOURTH FLOOR PLAN STAIRCASE - Flight Width Mt. 0.900 1.117 OK
STAIRCASE - Tread Width Mt. 0.250 0.255 OK
STAIRCASE - Riser Height Mt. 0.200 0.150 OK
STAIRCASE - Riser No. On Flight No. - 10 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
STAIRCASE - Flight Width Mt. 0.900 1.117 OK
STAIRCASE - Tread Width Mt. 0.250 0.255 OK
STAIRCASE - Riser Height Mt. 0.200 0.150 OK
STAIRCASE - Riser No. On Flight No. - 10 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
STAIRCASE - Flight Width Mt. 0.900 1.132 OK
STAIRCASE - Tread Width Mt. 0.250 0.250 OK
STAIRCASE - Riser Height Mt. 0.200 0.150 OK
STAIRCASE - Riser No. On Flight No. - 10 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
SECOND FLOOR PLAN Staircase -3FL - Flight Width Mt. 0.900 1.205 OK
Staircase -3FL - Tread Width Mt. 0.250 0.250 OK
Staircase -3FL - Riser Height Mt. 0.200 0.110 OK
Staircase -3FL - Riser No. On Flight No. - 10 OK
Staircase -3FL - Cabin Ht. Mt. - - - OK
FIRST FLOOR PLAN Staircase -3FL - Flight Width Mt. 0.900 1.205 OK
Staircase -3FL - Tread Width Mt. 0.250 0.250 OK
Staircase -3FL - Riser Height Mt. 0.200 0.100 OK
Staircase -3FL - Riser No. On Flight No. - 10 OK
Staircase -3FL - Cabin Ht. Mt. - - - OK
Toilet Area Sq.Mt. - 5.00 4.09 OK
Width Mt. - - 1.87 OK
Depth Mt. - - 2.20 OK
Height Mt. - - - OK
Sewage Treatment Plant Area Sq.Mt. - - 0.90 OK
Width Mt. - - 0.75 OK
Depth Mt. - - 1.21 OK
Height Mt. - - - OK
RAIN WATER HARVESTING Area Sq.Mt. - - 0.91 OK
Width Mt. - - 0.86 OK
Depth Mt. - - 1.07 OK
Height Mt. - - - OK
Area Sq.Mt. - - 4.09 OK
Width Mt. - - 1.87 OK
Depth Mt. - - 2.20 OK
Height Mt. - - - OK
ENT.GATE Area Sq.Mt. - - 1.51 OK
Width Mt. - - 0.49 OK
Depth Mt. - - 3.11 OK
Height Mt. - - - OK
SOLAR HEATING SYSTEM Area Sq.Mt. - - 0.88 OK
Width Mt. - - 0.86 OK
Depth Mt. - - 1.02 OK
Height Mt. - - - OK
Generator Room Area Sq.Mt. - - 4.09 OK
Width Mt. - - 1.87 OK
Depth Mt. - - 2.20 OK
Height Mt. - - - OK
C (SQUARE BUILDING BLOCK A) Rain Water Harvesting - No No. 1 - 2 OK
Entrance Gate - No No. 1 - 1 OK
D (CLUB HOUSE) Rain Water Harvesting - No No. 1 - 2 OK
Entrance Gate - No No. 1 - 1 OK
A (BLOCK 1) Rain Water Harvesting - No No. 1 - 2 OK
Entrance Gate - No No. 1 - 1 OK
2 (BLOCK 2) Rain Water Harvesting - No No. 1 - 2 OK
Entrance Gate - No No. 1 - 1 OK
PLOT 1.92 mt. long 0.15 mt. High 5.29 mt. Wide Natural Slope - Width Mt. - 1.92 OK
1.92 mt. long 0.15 mt. High 5.29 mt. Wide Natural Slope - Depth Mt. - 0.15 OK
1.92 mt. long 0.15 mt. High 5.29 mt. Wide Natural Slope - Slope Ratio - - - OK
1.92 mt. long 0.15 mt. High 5.29 mt. Wide Natural Slope - Width Mt. - 1.92 OK
1.92 mt. long 0.15 mt. High 5.29 mt. Wide Natural Slope - Depth Mt. - 0.15 OK
1.92 mt. long 0.15 mt. High 5.29 mt. Wide Natural Slope - Slope Ratio - - - OK
Ramp No. C (SQUARE BUILDING BLOCK A) - GROUND FLOOR PLAN - No. No. - 2 OK
C (SQUARE BUILDING BLOCK A) FOURTH FLOOR PLAN - C.B. - Width Mt. 0.60 0.35 OK
FOURTH FLOOR PLAN - C.B. - Depth Mt. - 1.81 OK
FOURTH FLOOR PLAN - C.B. - Area Sq.Mt. - 0.64 OK
FOURTH FLOOR PLAN - C.B. - Width Mt. 0.60 0.35 OK
FOURTH FLOOR PLAN - C.B. - Depth Mt. - 1.81 OK
FOURTH FLOOR PLAN - C.B. - Area Sq.Mt. - 0.64 OK
FOURTH FLOOR PLAN - C.B. - Width Mt. 0.60 0.35 OK
FOURTH FLOOR PLAN - C.B. - Depth Mt. - 1.81 OK
FOURTH FLOOR PLAN - C.B. - Area Sq.Mt. - 0.63 OK
FOURTH FLOOR PLAN - C.B. - Width Mt. 0.60 0.35 OK
FOURTH FLOOR PLAN - C.B. - Depth Mt. - 1.81 OK
FOURTH FLOOR PLAN - C.B. - Area Sq.Mt. - 0.63 OK
FOURTH FLOOR PLAN - C.B. - Width Mt. 0.60 0.43 OK
FOURTH FLOOR PLAN - C.B. - Depth Mt. - 1.39 OK
FOURTH FLOOR PLAN - C.B. - Area Sq.Mt. - 0.59 OK
FOURTH FLOOR PLAN - C.B. - Width Mt. 0.60 0.43 OK
FOURTH FLOOR PLAN - C.B. - Depth Mt. - 1.39 OK
FOURTH FLOOR PLAN - C.B. - Area Sq.Mt. - 0.59 OK
FOURTH FLOOR PLAN - C.B. - Width Mt. 0.60 0.43 OK
FOURTH FLOOR PLAN - C.B. - Depth Mt. - 1.38 OK
FOURTH FLOOR PLAN - C.B. - Area Sq.Mt. - 0.59 OK
FOURTH FLOOR PLAN - C.B. - Width Mt. 0.60 0.43 OK
FOURTH FLOOR PLAN - C.B. - Depth Mt. - 1.38 OK
FOURTH FLOOR PLAN - C.B. - Area Sq.Mt. - 0.59 OK
   
    All Rooms are as per Rule in Room Checking




[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Width No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Depth No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Access Width The minimum width of abutting road for any Building more than 13.3 mt. ht. shall be 6.1 mt.{As per Rule no. 35.1 Note 4}
Plot Frontage No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
FAR Area (1) In Old Area, for Residential Building on abutting roadwidth 9.10 (30 ft.) to 12.20 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15}
(2) For Lohardaga Nagar Parishad Max. 2.0 permissible FAR may be permitted for Residential Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Residential Building on abutting roadwidth 9.10 (30 ft.) to 12.20 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15}
(2) For Lohardaga Nagar Parishad Max. 2.0 permissible FAR may be permitted for Residential Use {As per Annexure III}
Common Plot Area In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
Common Plot (1) In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
(2) ;
Tree Number Mini. 8 Trees shall be required for the Plot area above 1000.0 sq.mt. (As per Rule No. 20.1.6)
DriveWay Rule (1) For Plor area above 2000 sq.mt., The minimum width or driveways should not be less than 4.50 mt. {As per Rule No. 41.2 and modified as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
(2) The minimum width of the drive way meant exclusively for 2 wheelers should be 3.0 mt {As per Rule No. 41.2}
Margin Rule (1) For Non-highrise Residential Building 13.3-16.4 mt. Ht. having Plot Depth 45 mt. or above and Plot width 45 mt. or above, Margin required in Front shall be 6.0 mt., Rear 5.0 mt. and 5.0 mt. shall be provided on both side. {As per Rule No. 36 (Table 8 & 9)}
(2) For Commercial & Storage buildings having plotarea above 1000 sq.mt., Margin required in Front shall be 9.0 mt., Rear 6.0 mt. and 6.0 mt. shall be provided on both side. {As per Rule No. 38.2.5}
PWork to PWork Margin Reqd Building to Building margin shall be 6 mt. or 1.5 times side setback required for the taller block whichever is high {As per Rule No. 38.1}
Building Level
Building Height For old area, on Road width 9.10-12.20 mt., Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 23.10 mt. {As per Rule No. 39.1 Table 15}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(3) The plinth or any part of a building shall be so located with respect to the surrounding ground level that adequate drainage of the site is assured. The height of the plinth (except in case of stilted parking) shall be not less than 0.45 mt. from the surrounding ground level {As per Rule No. 42.10}
Parapet Height (1) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
(2) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
(3) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
Floor Number For old area location,on Road width 9.1-12.20 mt. only G+6 floors shall be allowed {As per Rule No. 39.1 Table 15}
Lift Count (1) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(2) For Residential Building height 12.0 mt. or above, upto G+4 floors or if the number of flats is upto 16, provision of lift will be compulsory. {As per Rule No. 49.1.2}
(3) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(4) For Residential Building height upto 15.0 mt or upto G+4 floors, No Lift is reqd. {As per Amended 06-06-2019 Rule No. 49.1.1}
Lift (1) -
(2) The area of lift well at one floor only (not the sum of total area of lift well at every floor) shall be counted for F.A.R calculation)
(3) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(4) The area of lift well shall not be counted for F.A.R calculation)
(5) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
StairCase (1) No Rule Defined
(2) ; No Rule Defined
(3) Width of Winding staircase shall be mini. 0.90 mt.,Maximum rise 0.20 mt. & Minimum tread 0.25 mt. & Cabin Height 2.1 mt. {As per Rule No. 83.18}
(4) ; No Rule Defined
Ramp No Need to Check Natural Slope width, Depth or height. ;
Ramp No. -
Arch Projection (1) No need to check
(2) Cupboard up to 0.60 mt. in width shall be permitted. {As per Rule 6.26.1 and modified as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
Plot / Building Level
Accessory Use (1) Common toilet of maximum size of 5 sq.mt shall be taken Free from FAR
(2) No need to check distance from Building Toilet
(3) -
(4) No need to check distance from Building Sewage Treatment Plant
(5) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(6) No need to check distance from Building RAIN WATER HARVESTING
(7) No need to check distance from Building ENT.GATE
(8) -
(9) No need to check distance from Building SOLAR HEATING SYSTEM
(10) Electric cabin or substation of maximum size of 4 sq.m. with minimum width or diameter of 2 m
(11) No need to check distance from Building Generator Room
Accessory Use Number (1) Provision of Rain Water Harvesting shall be mandatory for any use {Updated as per JBBL, Amendment VIII dated 16/03/2021} Rain Water Harvesting
(2) In case of buildings with a height of 15.0 meters and above or ground coverage more than 500 sqm., the main entrance to the premise shall not be less than 5 (five) meters i n width in order to allow easy access to fire engine Entrance Gate
Building Level (Rooms)