Detail Scrutiny Report

Lohardaga Nagar Parishad

Version Number: 1.0.68  
Version Date: 16/10/2020 
Report Generated On: 29-01-2024 
 
[-] Collapse All


General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictLOHARDAGA
AuthorityLOHARDAGA NAGAR PARISHAD
Inward_NoLNP/BP/0006/W05/2024
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentNew
Location of Development AreaNew Area
City Area/TPScheme NoNA
VillageKaimo
Taluka26
Architect Details
Architect NameRASHID ZAFAR
License No.LNP/ENG/0005/2022
Architect AddressWard 11, Islam Nagar Lohardaga
Architect EmailIDengineerashidz@gmail.com
Architect Mobile No9060065465
Plot Details
Plot Use Residential
Plot SubUse Bungalow/ Dwelling / Non Apartment
PlotNearbyReligiousStructure NA
Plot/SubPlot No1261
NorthPlot No. - 1261
SouthPlot No. - 1261
EastRoad Width - 3.05
WestPlot No. - 1249
Owner's Details
NameNemhas Tirkey
AddressKaimo Patra Toli, Lohardaga
Email IDsumansamual@gmail.com
Mobile No7479490125
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 404.65
2 Plot area as per Document by Applicant 404.65
3 Physical area measured at site 404.65
4 Area as per Site Visit (Site Visit Report) 404.65
5Area as per Drawing 404.65

Area of Plot Considered : 404.65

[-] Table 2b
Proposal Detail :
UnitMeters
Development Detail :
PlotPLOT
Plot OccupancyResidential
Plot SubUse Bungalow/ Dwelling / Non Apartment
Building StructureNon-Highrise
Building TypeSingle Detached House
Gross Plot Area 404.65
Deduction from Gross Plot area
- Surrender Free of Cost 8.27
8.27
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 396.37
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 339.14
Deductions for Balance Plot Area (from Gross Plot Area)
- Surrender Free of Cost 8.27
- Common Plot 57.24
65.51
Balance Plot Area 339.14

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 60.00 % ) 237.82
Proposed Coverage Area ( 35.97 % ) 142.56
Total Prop. Coverage Area ( 35.97 % ) 142.56
Balance coverage area ( 24.03 % ) 95.26
FAR CHECK
Perm. FAR Area ( 1.200 ) 485.58
Total Perm. FAR area 485.58
Residential FAR 142.56
Proposed FAR Area 142.56
Total Proposed FAR Area 142.56
Consumed FAR (Factor) 0.35
Balance FAR Area 343.02
BUA CHECK
Total Proposed BuiltUp Area 142.56


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Up to 50 meter -
Existing Road Width 3.05 3.05
Proposed Road Width as per Master Plan 3.66 -
Road Widening Width 0.61 0.61
Plot size (as per measurement) 404.65 404.65
[-] Extra Land Area Checks
Name Area Status
Reqd Prop
Extra Land - 0.00 OK


[-] Plot Level Checking (Table 3)
   
[-] Common Plot Checks (Table 3b)
Name Total Area Status
Reqd Prop
Common Plot 19.82 57.24 OK


[-] Common Plot Checks (Table 3b)
Name Minimum Area Coverage Area Width Angle Access Status
Reqd Prop Perm Prop Reqd Prop Reqd Prop
Tree Cover (Plantation) - 57.24 0.00 0.00 - 5.70 - 90.00 No Access Provided OK


   
   
[-] Tree Details (Table 3g)
Name Nos Of Trees Status
Reqd Prop
Tree 4 7 OK
   
   
   
   
   


[-] Building Details (Table 4)
   
[-] Building USE/SUBUSE Details Building USE/SUBUSE Details
Building Name Building Use Building SubUse Building Structure
A (BUILDING) Residential Bungalow/ Dwelling / Non Apartment Non-Highrise
   
   
   
[-] Height Details (4a)



[-] Total Height (Table 4a-1)
Building Height (From GL) Height (From Street LVL) Status
A (BUILDING) 3.00 3.00 OK


   
   
[-] Floor Height Check (Table 4a-2)
Building Name Floor Name Height Clear Height Beam Clear Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
A (BUILDING) Ground Floor 2.75 - 3.00 2.75 - 2.90 2.40 - 2.75 OK
Plinth 0.45 - 0.60 - - 0.60 - - 0.60 OK


[-] Parapet Height Check (Table 4a-2.1)
Building Name Floor Name Height Clear Height Beam Clear Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
A (BUILDING) Terrace Floor - - 1.00 - - 0.90 - - 0.90 OK
   
   
   
[-] Floor Number Check (Table 4a-4)
Building Name No. of Floors No. of Tenements Status
Perm Prop Perm Prop
A (BUILDING) G + 1 1 - 1 OK

 
   
    [-] Coverage Check (Table 4b)
Permissible Proposed Status
237.82 142.56 OK
60% 35.97%

[-] Individual Coverage Check
Coverage Area Perm. Prop.
  A-1 (BUILDING) - 142.56
  Total Prop. Coverage Area - 142.56
  Total Coverage Area 237.82 142.56

[-] FAR & Tenement Details (Table 4c-1)
Building No. of Same Bldg Total Built Up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
Resi.
A (BUILDING) 1 142.56 142.56 142.56 142.56 01
Grand Total : 1 142.56 142.56 142.56 142.56 01


[-] Buildingwise Floor FAR Details
Floor Name Building Name Total
A (BUILDING)
Proposed Built Up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Total Proposed Built Up Area (Sq.mt.) Total FAR Area (Sq.mt.)
Ground Floor 142.56 142.56 142.56 142.56
Terrace Floor 0.00 0.00 0.00 0.00
Total : 142.56 142.56 142.56 142.56


[-] UnitBUA Table for Building :A (BUILDING)
UnitBUA CALCULATION
FLOOR Name UnitBUA Type UnitBUA Area Carpet Area No. of Rooms No. of Tenement
GROUND FLOOR PLAN SPLIT a FLAT 142.56 142.37 10 1
Total: - - 142.56 142.37 10 1


[-] Building :A (BUILDING)
Floor Name Total Built Up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
Resi.
Ground Floor 142.56 142.56 142.56 142.56 01
Terrace Floor 0.00 0.00 0.00 0.00 00
Total : 142.56 142.56 142.56 142.56 01
Total Number of Same Buildings : 1
Total : 142.56 142.56 142.56 142.56 01
[-] Table 4c-2

  FAR Area
Building FAR Area:142.56
Existing FAR Area :0.00
Perm.
485.58
Prop.
142.56
Status
OK




[-] Margin Checks (Table 5)
   
[-] Plot Margin (Table 5a)
Building / Wing Road Name Front Side Rear Side Side1 Side2 Status
Reqd. Prop. Reqd. Prop. Reqd. Prop. Reqd. Prop.
A-1 (BUILDING) ROAD WIDENING AREA(SURRENDERED FREE OF COST) 4.00 13.18 2.50 2.59 0.90 1.22 0.90 1.52 OK


[-] BldgLine Margin (Table 5a-1)
Building/Wing Front Side Reqd. Prop. Main Road Name ResvRoad Name Reqd. Width Prop. Width Status
A-1 (BUILDING) BldgLine for 3.05 METER WIDE ROAD 1.52 13.79 3.05 METER WIDE ROAD ROAD WIDENING AREA(SURRENDERED FREE OF COST) 1.52 0.61 Failed





[-] Inner Building Details (Table 6)
   

No OTS/Duct/VShaft/Balcony/Passage/Lift/Tenements Found.
   


[-] Parking Details (Table 7)
   

NO PARKING CHECK REQUIRED FOR SINGLE DWELLING UNIT. Bungalow/ Dwelling / Non Apartment, In Building: A (BUILDING)
   


[-] Exemption Details (Table 8)
   


Not Required to Check StairCase Number Rule.


[-] Staircase Checks (Table 8a-1)


[-] For Building :A (BUILDING)
Floor Name StairCase Name Flight Width Tread Width Riser Height Riser No. On Flight Cabin Ht. Status
Reqd Prop Reqd Prop Perm Prop Perm Prop Reqd Perm Prop
GROUND FLOOR PLAN Staircase -3FL 0.750 1.050 0.225 0.250 0.200 0.091 - 9 - - 0.000 OK
TERRACE FLOOR PLAN Staircabin -3FL - 1.050 - 0.250 - 0.000 - 0 2.100 - 2.400 OK

   
   
[-] Arch Projection Checks (Table 8c - a)

[-] For Building :A (BUILDING)
Floor Name Arch Proj Name Width Depth Area Status
Perm Prop Perm Prop Perm Prop
TERRACE FLOOR PLAN Barsati - 3.24 - 6.08 20.00 19.69 OK
   
   
   
[-] Accessory Use Check (Table 8d)
Accessory Use Name Area Width Depth Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
SEPTIK TANK - - 5.93 - - 1.82 - - 3.26 - - 0.00 OK
RAIN WATER HARVESTING - - 0.89 - - 1.06 - - 1.07 - - 0.00 OK
ENT.GATE - - 1.00 - - 0.28 - - 3.62 - - 0.00 OK
SOLAR HEATING SYSTEM - - 1.50 - - 1.08 - - 1.39 - - 0.00 OK





[-] Accessory Use No. Checks
Building Name Accessory Use Name No Status
Reqd Perm Prop
A (BUILDING) Rain Water Harvesting 1 - 1 OK
   
   


[-] Floor Details (Table 9)
   

[-] Building:A (BUILDING)


[-] Floor:GROUND FLOOR PLAN



All Dimensions and Area of all the Rooms on this Floor are as per the Rules.


   


[-] Summary (Table 10)
   
Name Perm./Reqd. Proposed Status
  Plot Area - 396.37 OK
  Plot Width - 13.55 OK
  Plot Depth - 29.26 OK
  Access Width - 3.05 OK
  Plot Frontage - 13.56 OK
  Coverage Area 237.82 142.56 OK
  FAR Area
Bldg. FAR Area : 142.56
Sanctioned FAR Area :0.00
485.58 142.56 OK





[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Width No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Depth No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Access Width The minimum width of abutting road for any Building shall be with respect to Length of Road {As per Rule No. 34 Table No.6}
Plot Frontage No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
FAR Area (1) In New Area, FAR for plot which lies on road less than 6.10 m. the width shall be taken as incase of Old Area {As per Addendum from Govt. of Jharkhand 3141 dated 15/05/2017}
(2) For Lohardaga Nagar Parishad Max. 2.0 permissible FAR may be permitted for Residential Use {As per Annexure III}
Consumed FAR (1) In New Area, FAR for plot which lies on road less than 6.10 m. the width shall be taken as incase of Old Area {As per Addendum from Govt. of Jharkhand 3141 dated 15/05/2017}
(2) For Lohardaga Nagar Parishad Max. 2.0 permissible FAR may be permitted for Residential Use {As per Annexure III}
Common Plot Area In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
Common Plot (1) In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
(2) ;
Tree Number 4-8 Trees shall be required for the Plot area above 250.0 and upto 1000.0 sq.mt. (As per Rule No. 20.1.6)
Margin Rule For Non-highrise Residential Building upto 10.0 mt. Ht. having Plot Depth 27-33 mt. and Plot width 10-15 mt., Margin required in Front shall be 4.0 mt., Rear 2.5 mt. and 0.9 mt. shall be provided on both side. {As per Rule No. 36 (Table 8 & 9)}
Building Line Check The min. width of Road for length of Road Upto 100 mt. shall be 6.1 mt. {As per Rule No. 34 Table No. 6}
ResvRoad Width Check The min. width of Road for length of Road Upto 100 mt. shall be 6.1 mt. {As per Rule No. 34 Table No. 6}
Building Level
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(3) The plinth or any part of a building shall be so located with respect to the surrounding ground level that adequate drainage of the site is assured. The height of the plinth (except in case of stilted parking) shall be not less than 0.45 mt. from the surrounding ground level {As per Rule No. 42.10}
Parapet Height (1) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
(2) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
(3) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
Floor Number In New Area, for plot which lies on road less than 6.10 m. Perm. No of Floor shall be taken as incase of Old Area {As per Addendum from Govt. of Jharkhand 3141 dated 15/05/2017}
StairCase (1) Width of Winding staircase shall be mini. 0.75 mt.,Maximum rise 0.20 mt. & Minimum tread 0.225 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) Width of Winding staircase shall be mini. 0.75 mt.,Maximum rise 0.20 mt. & Minimum tread 0.225 mt. & Cabin height 2.1 mt {As per Rule No. 83.18}
(4) ; No Rule Defined
Arch Projection (1) No need to check
(2) Barsati of upto 20.0sq.mt. area shall be permitted. {As per Rule No. 2.15}
Plot / Building Level
Accessory Use (1) -
(2) No need to check distance from Building SEPTIK TANK
(3) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(4) No need to check distance from Building RAIN WATER HARVESTING
(5) No need to check distance from Building ENT.GATE
(6) -
(7) No need to check distance from Building SOLAR HEATING SYSTEM
Accessory Use Number Provision of Rain Water Harvesting shall be mandatory for any use {Updated as per JBBL, Amendment VIII dated 16/03/2021} Rain Water Harvesting
Building Level (Rooms)
Bed Room3.60x3.85 The area of habitable room shall not be less than 9.5 m2, where there is only one room with a minimum width of 2.4 m. Where there are two rooms, one of these shall not be less than 9.5 m2 and the other not less than 7.5 m2, with a minimum width of 2.1 mt.
Bed Room4.05x3.42 The area of habitable room shall not be less than 9.5 m2, where there is only one room with a minimum width of 2.4 m. Where there are two rooms, one of these shall not be less than 9.5 m2 and the other not less than 7.5 m2, with a minimum width of 2.1 mt.
Bed Room4.35x3.85 The area of habitable room shall not be less than 9.5 m2, where there is only one room with a minimum width of 2.4 m. Where there are two rooms, one of these shall not be less than 9.5 m2 and the other not less than 7.5 m2, with a minimum width of 2.1 mt.
Drawing Room3.90x3.50 The area of habitable room shall not be less than 9.5 m2, where there is only one room with a minimum width of 2.4 m. Where there are two rooms, one of these shall not be less than 9.5 m2 and the other not less than 7.5 m2, with a minimum width of 2.1 mt.
Dress Room1.12x1.67 No Rule Defined
Kitchen2.10x3.50 Area for Kitchen shall be Mini. 5.0 sq.mt. having side mini. 1.8 mt. {Rule No. 42.3.2}
Living/dining6.12x5.10 The area of habitable room shall not be less than 9.5 m2, where there is only one room with a minimum width of 2.4 m. Where there are two rooms, one of these shall not be less than 9.5 m2 and the other not less than 7.5 m2, with a minimum width of 2.1 mt.
Toilet2.10x1.85 Area for Toilet shall be Mini. 2.8 sq.mt. having side mini. 1.2 mt. {Rule No. 42.4.2}
Toilet2.10x1.88 Area for Toilet shall be Mini. 2.8 sq.mt. having side mini. 1.2 mt. {Rule No. 42.4.2}
Toilet2.80x1.67 Area for Toilet shall be Mini. 2.8 sq.mt. having side mini. 1.2 mt. {Rule No. 42.4.2}