No Image Found   

Check List Report

Lohardaga Nagar Parishad

Version Number: 1.0.70  
Version Date: 16/10/2020 
Report Generated On: 01-08-2024 
 

[-] Collapse All


General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictLOHARDAGA
AuthorityLOHARDAGA NAGAR PARISHAD
Inward_NoLNP/BP/0042/W22/2024
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentNew
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillageLohardaga
Taluka26
Architect Details
Architect NameAshish Deep Toppo
License No.LNP/ARC/0009/2017
Architect AddressS/O Atul Kumar Suman Toppo G. E. L. Mission Compound Anandpur
Architect EmailIDashish.d.toppo@gmail.com
Architect Mobile No7992304518
Plot Details
Plot Use Residential
Plot SubUse Hostel
PlotNearbyReligiousStructure NA
Plot/SubPlot No3006,3005
NorthRoad Width - 12
SouthPlot No. - 3005
EastRoad Width - 3006
WestPlot No. - 3005
Owner's Details
NameSt. Ursula Hospital
AddressSt. Ursula Hospital College Road
Email IDashish.d.toppo@gmail.com
Mobile No7992304518
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 3560.00
2 Plot area as per Document by Applicant 3558.00
3 Area as per Site Visit (Site Visit Report) 3558.00
4Area as per Drawing 3558.81

Area of Plot Considered : 3558.00

Plot area provided in drawing shall not be more than Plot area as per Document.
[-] Table 2b
Proposal Detail :
Unit
Development Detail :
PlotPLOT
Plot OccupancyResidential
Plot SubUse Hostel
Building StructureNon-Highrise
Building TypeSingle Detached House
Gross Plot Area 3558.00
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 3558.00
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 2815.75
Deductions for Balance Plot Area (from Gross Plot Area)
- Common Plot 742.25
742.25
Balance Plot Area 2815.75

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 50.00 % ) 1779.00
Proposed Coverage Area ( 10.16 % ) 361.52
Total Prop. Coverage Area ( 10.16 % ) 361.52
Balance coverage area ( 39.84 % ) 1417.48
FAR CHECK
Perm. FAR Area ( 2.000 ) 7116.00
Total Perm. FAR area 7116.00
Residential FAR 1084.57
Proposed FAR Area 1084.57
Total Proposed FAR Area 1084.57
Consumed FAR (Factor) 0.30
Balance FAR Area 6031.43
BUA CHECK
Total Proposed BuiltUp Area 1084.56


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Exceeding 100 meter and upto 250 meter -
Existing Road Width 12 12.00
Proposed Road Width as per Master Plan 12 -
Road Widening Width 0 -
Plot size (as per measurement) 3558 3558.81
[-] Extra Land Area Checks
Name Area Status
Reqd Prop
Extra Land - 0.00 OK

     Extra Land Area Details
Name Description Unit Reqd Perm Proposed Status
Extra Land Area Details Extra Land Area - - 0.00 OK

     Plot Related Details
Name Description Unit Reqd Perm Proposed Status
PLOT Plot Area Sq.Mt. - - 3558.00 OK
Plot Width Mt. - - 31.69 OK
Plot Depth Mt. - - 112.31 OK
Access Width Mt. - - 12.00 OK
Plot Frontage Mt. - - 24.46 OK
Coverage Area Sq.Mt. - 1779.00 361.52 OK
FAR Area Sq.Mt. - 7116.00 1084.57 OK
Consumed FAR Sq.Mt. - 2.00 0.30 OK
Common Plot Checks Common Plot - Total Area Sq.Mt. 177.90 742.25 OK
Common Plot Tree Cover (Plantation) - Minimum Area Sq.Mt. - 742.25 OK
Tree Cover (Plantation) - Coverage Area Sq.Mt. - - OK
Tree Cover (Plantation) - Width Mt. - 24.05 OK
Tree Cover (Plantation) - Angle Degree - 90.00 OK
Tree Cover (Plantation) - Access Mt. - OK
Tree Tree - Nos Of Trees No. 8 20 OK
Car In Area Sq.Mt. - - 12.50 OK
Total Car In Area Sq.Mt. 12.50 - 12.50 OK
Visitor's Car Parking In Area Sq.Mt. - - 12.50 OK
Total Visitor Parking In Area Sq.Mt. 12.50 - 12.50 OK
A-1 (HOSTEL BUILDING G2) Front Margin... 12.00 mt. Wide MainRoad Mt. 4.00 - 67.68 OK
Rear Margin Mt. 4.00 - 21.41 OK
Side1 Margin Mt. 1.50 - 6.77 OK
Side2 Margin Mt. 1.50 - 6.00 OK

     Building Related Details
Name Description Unit Reqd Perm Proposed Status
A (HOSTEL BUILDING G2) Height Mt. 23.10 9.00 OK
A (HOSTEL BUILDING G2) Second Floor - Height Mt. 2.75 - 3.00 OK
Second Floor - Clear Height Mt. 2.75 - 2.90 OK
Second Floor - Beam Clear Height Mt. 2.40 - 2.75 OK
First Floor - Height Mt. 2.75 - 3.00 OK
First Floor - Clear Height Mt. 2.75 - 2.90 OK
First Floor - Beam Clear Height Mt. 2.40 - 2.75 OK
Ground Floor - Height Mt. 2.75 - 3.00 OK
Ground Floor - Clear Height Mt. 2.75 - 2.90 OK
Ground Floor - Beam Clear Height Mt. 2.40 - 2.75 OK
Plinth - Height Mt. 0.45 - 0.45 OK
Plinth - Clear Height Mt. - - 0.45 OK
Plinth - Beam Clear Height Mt. - - 0.45 OK
A (HOSTEL BUILDING G2) Terrace Floor - Height Mt. - - 1.00 OK
Terrace Floor - Clear Height Mt. - - 1.00 OK
Terrace Floor - Beam Clear Height Mt. - - 1.00 OK
A (HOSTEL BUILDING G2) No. of Floors No. G + 6 3 OK
No. of Tenements No. - 3 OK
GROUND FLOOR PLAN STAIRCASE - Flight Width Mt. 0.900 1.163 OK
STAIRCASE - Tread Width Mt. 0.250 0.250 OK
STAIRCASE - Riser Height Mt. 0.200 0.150 OK
STAIRCASE - Riser No. On Flight No. - 10 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
FIRST FLOOR PLAN STAIRCASE - Flight Width Mt. 0.900 1.163 OK
STAIRCASE - Tread Width Mt. 0.250 0.250 OK
STAIRCASE - Riser Height Mt. 0.200 0.150 OK
STAIRCASE - Riser No. On Flight No. - 10 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
SECOND FLOOR PLAN STAIRCASE - Flight Width Mt. 0.900 1.163 OK
STAIRCASE - Tread Width Mt. 0.250 0.250 OK
STAIRCASE - Riser Height Mt. 0.200 0.150 OK
STAIRCASE - Riser No. On Flight No. - 10 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
TERRACE FLOOR PLAN STAIRCASE - Flight Width Mt. - 1.163 OK
STAIRCASE - Tread Width Mt. - 0.250 OK
STAIRCASE - Riser Height Mt. - - OK
STAIRCASE - Riser No. On Flight No. - - OK
STAIRCASE - Cabin Ht. Mt. - - 2.400 OK
SUMP TANK Area Sq.Mt. - - 10.54 OK
Width Mt. - - 1.52 OK
Depth Mt. - - 6.96 OK
Height Mt. - - - OK
RAIN WATER HARVESTING Area Sq.Mt. - - 33.37 OK
Width Mt. - - 3.95 OK
Depth Mt. - - 8.45 OK
Height Mt. - - - OK
ENT.GATE Area Sq.Mt. - - 9.28 OK
Width Mt. - - 1.32 OK
Depth Mt. - - 7.06 OK
Height Mt. - - - OK
SOLAR HEATING SYSTEM Area Sq.Mt. - - 33.37 OK
Width Mt. - - 3.95 OK
Depth Mt. - - 8.45 OK
Height Mt. - - - OK
A (HOSTEL BUILDING G2) Rain Water Harvesting - No No. 1 - 1 OK
Solar Water Heating System - No No. 1 - 1 OK
Entrance Gate - No No. 1 - 1 OK
   
    All Rooms are as per Rule in Room Checking




[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Width No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Depth No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Access Width The minimum width of abutting road for any Building shall be with respect to Length of Road {As per Rule No. 34 Table No.6}
Plot Frontage No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
FAR Area (1) In Old Area, for Residential Building on abutting roadwidth 9.10 (30 ft.) to 12.20 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15}
(2) For Lohardaga Nagar Parishad Max. 2.0 permissible FAR may be permitted for Residential Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Residential Building on abutting roadwidth 9.10 (30 ft.) to 12.20 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15}
(2) For Lohardaga Nagar Parishad Max. 2.0 permissible FAR may be permitted for Residential Use {As per Annexure III}
Common Plot Area In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
Common Plot (1) In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
(2) ;
Tree Number Mini. 8 Trees shall be required for the Plot area above 1000.0 sq.mt. (As per Rule No. 20.1.6)
Margin Rule For Non-highrise Residential Building upto 10.0 mt. Ht. having Plot Depth 39-45 mt. and Plot width 27-33 mt., Margin required in Front shall be 4.0 mt., Rear 4.0 mt. and 1.5 mt. shall be provided on both side. {As per Rule No. 36 (Table 8 & 9)}
Building Level
Building Height For old area, on Road width 9.10-12.20 mt., Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 23.10 mt. {As per Rule No. 39.1 Table 15}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(3) The plinth or any part of a building shall be so located with respect to the surrounding ground level that adequate drainage of the site is assured. The height of the plinth (except in case of stilted parking) shall be not less than 0.45 mt. from the surrounding ground level {As per Rule No. 42.10}
Parapet Height (1) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
(2) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
(3) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
Floor Number For old area location,on Road width 9.1-12.20 mt. only G+6 floors shall be allowed {As per Rule No. 39.1 Table 15}
StairCase (1) Width of Winding staircase shall be mini. 0.90 mt.,Maximum rise 0.20 mt. & Minimum tread 0.25 mt. & Cabin Height 2.1 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) No Rule Defined
(4) ; No Rule Defined
Plot / Building Level
Accessory Use (1) -
(2) No need to check distance from Building SUMP TANK
(3) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(4) No need to check distance from Building RAIN WATER HARVESTING
(5) No need to check distance from Building ENT.GATE
(6) -
(7) No need to check distance from Building SOLAR HEATING SYSTEM
Accessory Use Number (1) Provision of Rain Water Harvesting shall be mandatory for any use {Updated as per JBBL, Amendment VIII dated 16/03/2021} Rain Water Harvesting
(2) For Hostel type of Building, Provisions of Solar Water Heating System shall be done. Solar Water Heating System
(3) In case of buildings with a height of 15.0 meters and above or ground coverage more than 500 sqm., the main entrance to the premise shall not be less than 5 (five) meters i n width in order to allow easy access to fire engine Entrance Gate
Building Level (Rooms)
Hall19.17x13.32 No Rule Defined
Hall25.65x7.82 No Rule Defined
Room10.65x5.50 No Rule Defined
Room11.00x5.50 No Rule Defined
Room3.50x5.47 No Rule Defined
Room3.50x7.60 No Rule Defined
Room7.93x5.50 No Rule Defined
Wc1.38x1.20 No Rule Defined
Wc1.38x1.23 No Rule Defined