No Image Found   

Detail Scrutiny Report

Lohardaga Nagar Parishad

Version Number: 1.0.70  
Version Date: 16/10/2020 
Report Generated On: 01-08-2024 
 
[-] Collapse All


General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictLOHARDAGA
AuthorityLOHARDAGA NAGAR PARISHAD
Inward_NoLNP/BP/0042/W22/2024
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentNew
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillageLohardaga
Taluka26
Architect Details
Architect NameAshish Deep Toppo
License No.LNP/ARC/0009/2017
Architect AddressS/O Atul Kumar Suman Toppo G. E. L. Mission Compound Anandpur
Architect EmailIDashish.d.toppo@gmail.com
Architect Mobile No7992304518
Plot Details
Plot Use Residential
Plot SubUse Hostel
PlotNearbyReligiousStructure NA
Plot/SubPlot No3006,3005
NorthRoad Width - 12
SouthPlot No. - 3005
EastRoad Width - 3006
WestPlot No. - 3005
Owner's Details
NameSt. Ursula Hospital
AddressSt. Ursula Hospital College Road
Email IDashish.d.toppo@gmail.com
Mobile No7992304518
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 3560.00
2 Plot area as per Document by Applicant 3558.00
3 Area as per Site Visit (Site Visit Report) 3558.00
4Area as per Drawing 3558.81

Area of Plot Considered : 3558.00

Plot area provided in drawing shall not be more than Plot area as per Document.
[-] Table 2b
Proposal Detail :
UnitMeters
Development Detail :
PlotPLOT
Plot OccupancyResidential
Plot SubUse Hostel
Building StructureNon-Highrise
Building TypeSingle Detached House
Gross Plot Area 3558.00
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 3558.00
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 2815.75
Deductions for Balance Plot Area (from Gross Plot Area)
- Common Plot 742.25
742.25
Balance Plot Area 2815.75

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 50.00 % ) 1779.00
Proposed Coverage Area ( 10.16 % ) 361.52
Total Prop. Coverage Area ( 10.16 % ) 361.52
Balance coverage area ( 39.84 % ) 1417.48
FAR CHECK
Perm. FAR Area ( 2.000 ) 7116.00
Total Perm. FAR area 7116.00
Residential FAR 1084.57
Proposed FAR Area 1084.57
Total Proposed FAR Area 1084.57
Consumed FAR (Factor) 0.30
Balance FAR Area 6031.43
BUA CHECK
Total Proposed BuiltUp Area 1084.56


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Exceeding 100 meter and upto 250 meter -
Existing Road Width 12 12.00
Proposed Road Width as per Master Plan 12 -
Road Widening Width 0 -
Plot size (as per measurement) 3558 3558.81
[-] Extra Land Area Checks
Name Area Status
Reqd Prop
Extra Land - 0.00 OK


[-] Plot Level Checking (Table 3)
   
[-] Common Plot Checks (Table 3b)
Name Total Area Status
Reqd Prop
Common Plot 177.90 742.25 OK


[-] Common Plot Checks (Table 3b)
Name Minimum Area Coverage Area Width Angle Access Status
Reqd Prop Perm Prop Reqd Prop Reqd Prop
Tree Cover (Plantation) - 742.25 0.00 0.00 - 24.05 - 90.00 No Access Provided OK


   
   
[-] Tree Details (Table 3g)
Name Nos Of Trees Status
Reqd Prop
Tree 8 20 OK
   
   
   
   
   


[-] Building Details (Table 4)
   
[-] Building USE/SUBUSE Details Building USE/SUBUSE Details
Building Name Building Use Building SubUse Building Structure
A (HOSTEL BUILDING G2) Residential Hostel Non-Highrise
   
   
   
[-] Height Details (4a)



[-] Total Height (Table 4a-1)
Building Height Height (From GL) Height (From Street LVL) Status
Perm Prop
A (HOSTEL BUILDING G2) 23.10 9.00 9.00 9.00 OK


   
   
[-] Floor Height Check (Table 4a-2)
Building Name Floor Name Height Clear Height Beam Clear Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
A (HOSTEL BUILDING G2) Second Floor 2.75 - 3.00 2.75 - 2.90 2.40 - 2.75 OK
First Floor 2.75 - 3.00 2.75 - 2.90 2.40 - 2.75 OK
Ground Floor 2.75 - 3.00 2.75 - 2.90 2.40 - 2.75 OK
Plinth 0.45 - 0.45 - - 0.45 - - 0.45 OK


[-] Parapet Height Check (Table 4a-2.1)
Building Name Floor Name Height Clear Height Beam Clear Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
A (HOSTEL BUILDING G2) Terrace Floor - - 1.00 - - 1.00 - - 1.00 OK
   
   
   
[-] Floor Number Check (Table 4a-4)
Building Name No. of Floors No. of Tenements Status
Perm Prop Perm Prop
A (HOSTEL BUILDING G2) G + 6 3 - 3 OK

 
   
    [-] Coverage Check (Table 4b)
Permissible Proposed Status
1779.00 361.52 OK
50% 10.16%

[-] Individual Coverage Check
Coverage Area Perm. Prop.
  A-1 (HOSTEL BUILDING G2) - 361.52
  Total Prop. Coverage Area - 361.52
  Total Coverage Area 1779.00 361.52

[-] FAR & Tenement Details (Table 4c-1)
Building No. of Same Bldg Total Built Up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
Resi.
A (HOSTEL BUILDING G2) 1 1084.56 1084.56 1084.56 1084.56 03
Grand Total : 1 1084.56 1084.56 1084.56 1084.56 03


[-] Buildingwise Floor FAR Details
Floor Name Building Name Total
A (HOSTEL BUILDING G2)
Proposed Built Up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Total Proposed Built Up Area (Sq.mt.) Total FAR Area (Sq.mt.)
Ground Floor 361.52 361.52 361.52 361.52
First Floor 361.52 361.52 361.52 361.52
Second Floor 361.52 361.52 361.52 361.52
Terrace Floor 0.00 0.00 0.00 0.00
Total : 1084.56 1084.56 1084.56 1084.56


[-] UnitBUA Table for Building :A (HOSTEL BUILDING G2)
UnitBUA CALCULATION
FLOOR Name UnitBUA Type UnitBUA Area Carpet Area No. of Rooms No. of Tenement
GROUND FLOOR PLAN UNIT 1 FLAT 361.52 359.87 3 1
FIRST FLOOR PLAN UNIT 2 FLAT 361.52 360.09 16 1
SECOND FLOOR PLAN UNIT 3 FLAT 361.52 357.95 1 1
Total: - - 1084.56 1077.91 20 3


[-] Building :A (HOSTEL BUILDING G2)
Floor Name Total Built Up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
Resi.
Ground Floor 361.52 361.52 361.52 361.52 01
First Floor 361.52 361.52 361.52 361.52 01
Second Floor 361.52 361.52 361.52 361.52 01
Terrace Floor 0.00 0.00 0.00 0.00 00
Total : 1084.56 1084.56 1084.56 1084.56 03
Total Number of Same Buildings : 1
Total : 1084.56 1084.56 1084.56 1084.56 03
[-] Table 4c-2

  FAR Area
Building FAR Area:1084.57
Existing FAR Area :0.00
Perm.
7116.00
Prop.
1084.57
Status
OK




[-] Margin Checks (Table 5)
   
[-] Plot Margin (Table 5a)
Building / Wing Road Name Front Side Rear Side Side1 Side2 Status
Reqd. Prop. Reqd. Prop. Reqd. Prop. Reqd. Prop.
A-1 (HOSTEL BUILDING G2) 12.00 mt. Wide MainRoad 4.00 67.68 4.00 21.41 1.50 6.77 1.50 6.00 OK






[-] Inner Building Details (Table 6)
   

No OTS/Duct/VShaft/Balcony/Passage/Lift/Tenements Found.
   


[-] Parking Details (Table 7)
   
[-] Required Parking(Table 7a)
Building Name Type SubUse Area (Sq.mt.) Units Car Visitors Car
Reqd. Prop. Reqd./Unit Reqd. Prop. Reqd./Unit Reqd. Prop.
A (HOSTEL BUILDING G2) Residential Hostel > 0 6 - 1 1 - - - -
> 0 6 - - - - 1 1 -
Total : - - - - 1 1 - 1 1

[-] Parking Check (Table 7b)
Vehicle Type Reqd. Prop. Status
No. Area No. Area
Car - - 1 12.50 OK
Total Car 1 12.50 1 12.50 OK
Visitor's Car Parking - - 1 12.50 OK
Total Visitor Parking 1 12.50 1 12.50 OK
Total 25.00 25.00 OK

Individual Parking Checks (Table 7c)
Dimensions and Area for all Vehicle(s) are as per the Rules


   


[-] Exemption Details (Table 8)
   


Not Required to Check StairCase Number Rule.


[-] Staircase Checks (Table 8a-1)


[-] For Building :A (HOSTEL BUILDING G2)
Floor Name StairCase Name Flight Width Tread Width Riser Height Riser No. On Flight Cabin Ht. Status
Reqd Prop Reqd Prop Perm Prop Perm Prop Reqd Perm Prop
GROUND FLOOR PLAN STAIRCASE 0.900 1.163 0.250 0.250 0.200 0.150 - 10 - - 0.000 OK
FIRST FLOOR PLAN STAIRCASE 0.900 1.163 0.250 0.250 0.200 0.150 - 10 - - 0.000 OK
SECOND FLOOR PLAN STAIRCASE 0.900 1.163 0.250 0.250 0.200 0.150 - 10 - - 0.000 OK
TERRACE FLOOR PLAN STAIRCASE - 1.163 - 0.250 - 0.000 - 0 - - 2.400 OK

   
   
   
[-] Accessory Use Check (Table 8d)
Accessory Use Name Area Width Depth Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
SUMP TANK - - 10.54 - - 1.52 - - 6.96 - - 0.00 OK
RAIN WATER HARVESTING - - 33.37 - - 3.95 - - 8.45 - - 0.00 OK
ENT.GATE - - 9.28 - - 1.32 - - 7.06 - - 0.00 OK
SOLAR HEATING SYSTEM - - 33.37 - - 3.95 - - 8.45 - - 0.00 OK





[-] Accessory Use No. Checks
Building Name Accessory Use Name No Status
Reqd Perm Prop
A (HOSTEL BUILDING G2) Rain Water Harvesting 1 - 1 OK
Solar Water Heating System 1 - 1 OK
Entrance Gate 1 - 1 OK
   
   


[-] Floor Details (Table 9)
   

[-] Building:A (HOSTEL BUILDING G2)


[-] Floor:GROUND FLOOR PLAN



All Dimensions and Area of all the Rooms on this Floor are as per the Rules.

[-] Floor:FIRST FLOOR PLAN



All Dimensions and Area of all the Rooms on this Floor are as per the Rules.

[-] Floor:SECOND FLOOR PLAN



All Dimensions and Area of all the Rooms on this Floor are as per the Rules.


   


[-] Summary (Table 10)
   
Name Perm./Reqd. Proposed Status
  Plot Area - 3558.00 OK
  Plot Width - 31.69 OK
  Plot Depth - 112.31 OK
  Access Width - 12.00 OK
  Plot Frontage - 24.46 OK
  Coverage Area 1779.00 361.52 OK
  FAR Area
Bldg. FAR Area : 1084.57
Sanctioned FAR Area :0.00
7116.00 1084.57 OK





[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Width No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Depth No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Access Width The minimum width of abutting road for any Building shall be with respect to Length of Road {As per Rule No. 34 Table No.6}
Plot Frontage No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
FAR Area (1) In Old Area, for Residential Building on abutting roadwidth 9.10 (30 ft.) to 12.20 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15}
(2) For Lohardaga Nagar Parishad Max. 2.0 permissible FAR may be permitted for Residential Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Residential Building on abutting roadwidth 9.10 (30 ft.) to 12.20 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15}
(2) For Lohardaga Nagar Parishad Max. 2.0 permissible FAR may be permitted for Residential Use {As per Annexure III}
Common Plot Area In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
Common Plot (1) In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
(2) ;
Tree Number Mini. 8 Trees shall be required for the Plot area above 1000.0 sq.mt. (As per Rule No. 20.1.6)
Margin Rule For Non-highrise Residential Building upto 10.0 mt. Ht. having Plot Depth 39-45 mt. and Plot width 27-33 mt., Margin required in Front shall be 4.0 mt., Rear 4.0 mt. and 1.5 mt. shall be provided on both side. {As per Rule No. 36 (Table 8 & 9)}
Building Level
Building Height For old area, on Road width 9.10-12.20 mt., Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 23.10 mt. {As per Rule No. 39.1 Table 15}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(3) The plinth or any part of a building shall be so located with respect to the surrounding ground level that adequate drainage of the site is assured. The height of the plinth (except in case of stilted parking) shall be not less than 0.45 mt. from the surrounding ground level {As per Rule No. 42.10}
Parapet Height (1) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
(2) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
(3) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
Floor Number For old area location,on Road width 9.1-12.20 mt. only G+6 floors shall be allowed {As per Rule No. 39.1 Table 15}
StairCase (1) Width of Winding staircase shall be mini. 0.90 mt.,Maximum rise 0.20 mt. & Minimum tread 0.25 mt. & Cabin Height 2.1 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) No Rule Defined
(4) ; No Rule Defined
Plot / Building Level
Accessory Use (1) -
(2) No need to check distance from Building SUMP TANK
(3) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(4) No need to check distance from Building RAIN WATER HARVESTING
(5) No need to check distance from Building ENT.GATE
(6) -
(7) No need to check distance from Building SOLAR HEATING SYSTEM
Accessory Use Number (1) Provision of Rain Water Harvesting shall be mandatory for any use {Updated as per JBBL, Amendment VIII dated 16/03/2021} Rain Water Harvesting
(2) For Hostel type of Building, Provisions of Solar Water Heating System shall be done. Solar Water Heating System
(3) In case of buildings with a height of 15.0 meters and above or ground coverage more than 500 sqm., the main entrance to the premise shall not be less than 5 (five) meters i n width in order to allow easy access to fire engine Entrance Gate
Building Level (Rooms)
Hall19.17x13.32 No Rule Defined
Hall25.65x7.82 No Rule Defined
Room10.65x5.50 No Rule Defined
Room11.00x5.50 No Rule Defined
Room3.50x5.47 No Rule Defined
Room3.50x7.60 No Rule Defined
Room7.93x5.50 No Rule Defined
Wc1.38x1.20 No Rule Defined
Wc1.38x1.23 No Rule Defined