-
No Image Found

Check List Report

Medininagar Nagar Parishad

Version Number: 1.0.37
Version Date: 29/04/2019
Report Generated On: 18-07-2019

[-] Collapse All


General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictPALAMU
AuthorityMEDININAGAR NAGAR PARISHAD
Inward_NoMNNP/BP/0040/W26/2019
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentNew
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillageBaralota Rodma
Taluka27
Architect Details
Architect NameRANJIT KUMAR
License No.MNNP/ENG/0001/2016
Architect AddressSHANTI BHAVAN, HAMIDGANJ, DALTONGANJ
Architect EmailIDraj.vermak7@gmail.com
Architect Mobile No9470594617
Plot Details
Plot Use Residential
Plot SubUse Bungalow/ Dwelling / Non Apartment
PlotNearbyReligiousStructure NA
Plot/SubPlot No2233A
North -
South -
East -
West -
Owner's Details
NameRUBY SINGH
AddressREDMA, MEDININAGAR, PALAMU,JHARKHAND
Email IDCHANDAN0384.SINGH@GMAIL.COM
Mobile No9470969306
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 131.57
2 Plot area as per Document by Applicant 131.57
3 Area as per Site Visit (Site Visit Report) 131.57
4Area as per Drawing 123.30

Area of Plot Considered : 123.30

[-] Table 2b
Proposal Detail :
UnitMeters
Development Detail :
PlotPLOT
Plot OccupancyResidential
Plot SubUse Bungalow/ Dwelling / Non Apartment
Building StructureNon-Highrise
Building TypeSingle Detached House
Gross Plot Area 123.30
Deduction from Gross Plot area
- Surrender Free of Cost 8.47
8.47
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 114.83
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 103.04
Deductions for Balance Plot Area (from Gross Plot Area)
- Surrender Free of Cost 8.47
- Common Plot 11.79
20.26
Balance Plot Area 103.04

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 70.00 % ) 80.38
Proposed Coverage Area ( 63.61 % ) 73.05
Total Prop. Coverage Area ( 63.61 % ) 73.05
Balance coverage area ( 6.38 % ) 7.33
FAR CHECK
Perm. FAR Area ( 1.20 ) 147.96
Total Perm. FAR area 147.96
Residential FAR 73.05
Proposed FAR Area 82.96
Total Proposed FAR Area 82.96
Consumed FAR (Factor) 0.67
Balance FAR Area 65.00
BUA CHECK
Total Proposed BuiltUp Area 146.10


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Exceeding 50 meter and upto 100 meter -
Existing Road Width 3.04 3.04
Proposed Road Width as per Master Plan 0 -
Road Widening Width 0 1.03
Plot size (as per measurement) 131.57 123.30
[-] Extra Land Area Checks
Name Area Status
Reqd Prop
Extra Land - 0.00 OK

Extra Land Area Details
Name Description Unit Reqd Perm Proposed Status
Extra Land Area Details Extra Land Area - - 0.00 OK

Plot Related Details
Name Description Unit Reqd Perm Proposed Status
PLOT Plot Area Sq.Mt. - - 114.83 OK
Plot Width Mt. - - 8.22 OK
Plot Depth Mt. - - 13.97 OK
Access Width Mt. - - 3.04 OK
Plot Frontage Mt. - - 8.22 OK
Coverage Area Sq.Mt. - 80.38 73.05 OK
FAR Area Sq.Mt. - 147.96 82.96 OK
Consumed FAR Sq.Mt. - 1.20 0.67 OK
Common Plot Checks Common Plot - Total Area Sq.Mt. 5.74 11.79 OK
Common Plot Tree Cover (Plantation) - Minimum Area Sq.Mt. - 11.79 OK
Tree Cover (Plantation) - Coverage Area Sq.Mt. - - OK
Tree Cover (Plantation) - Width Mt. - 1.44 OK
Tree Cover (Plantation) - Angle Degree - 90.00 OK
Tree Cover (Plantation) - Access Mt. - OK
Tree Tree - Nos Of Trees No. 2 3 OK
A-1 (BUILDING) Front Margin... ROAD WIDENING AREA(SURRENDERED FREE OF COST) Mt. 2.00 - 2.49 OK
Rear Margin Mt. 1.50 - 1.50 OK
Side1 Margin Mt. 0.90 - 0.90 OK
Side2 Margin Mt. - - 0.00 OK
A-1 (BUILDING) BldgLine for 3.04 MTR WIDE ROAD Mt. 1.03 3.52 OK
A-1 (BUILDING) ResvRoad Width Check for... 3.04 MTR WIDE ROAD Mt. 1.03 1.03 OK

Building Related Details
Name Description Unit Reqd Perm Proposed Status
A (BUILDING) First Floor - Height Mt. 2.75 - 3.00 OK
First Floor - Clear Height Mt. 2.75 - 2.90 OK
First Floor - Beam Clear Height Mt. 2.40 - 2.75 OK
Ground Floor - Height Mt. 2.75 - 3.00 OK
Ground Floor - Clear Height Mt. 2.75 - 2.90 OK
Ground Floor - Beam Clear Height Mt. 2.40 - 2.75 OK
Plinth - Height Mt. 0.45 - 0.60 OK
Plinth - Clear Height Mt. - - 0.60 OK
Plinth - Beam Clear Height Mt. - - 0.60 OK
A (BUILDING) Terrace Floor - Height Mt. 1.00 1.20 1.00 OK
A (BUILDING) No. of Floors No. G + 1 2 OK
No. of Tenements No. - 1 OK
GROUND FLOOR PLAN STAIRCASE - Flight Width Mt. 0.750 2.130 OK
STAIRCASE - Tread Width Mt. 0.225 0.240 OK
STAIRCASE - Riser Height Mt. 0.200 0.200 OK
STAIRCASE - Riser No. On Flight No. - 15 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
FIRST FLOOR PLAN STAIRCASE - Flight Width Mt. 0.750 2.130 OK
STAIRCASE - Tread Width Mt. 0.225 0.240 OK
STAIRCASE - Riser Height Mt. 0.200 0.200 OK
STAIRCASE - Riser No. On Flight No. - 15 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
Toilet Area Sq.Mt. - 5.00 1.53 OK
Width Mt. - - 1.01 OK
Depth Mt. - - 1.52 OK
Height Mt. - - - OK
SUMP TANK Area Sq.Mt. - - 0.41 OK
Width Mt. - - 0.49 OK
Depth Mt. - - 0.84 OK
Height Mt. - - - OK
RAIN WATER HARVESTING Area Sq.Mt. - - 0.68 OK
Width Mt. - - 0.73 OK
Depth Mt. - - 0.94 OK
Height Mt. - - - OK
All Rooms are as per Rule in Room Checking




[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use
Plot Width No rule provided for Min. Plot size for proposed Use
Plot Depth No rule provided for Min. Plot size for proposed Use
Access Width The minimum width of abutting road for any Building shall be with respect to Length of Road {As per Rule No. 34 Table No.6}
Plot Frontage No rule provided for Min. Plot size for proposed Use
FAR Area (1) In Old Area, for Residential Building on abutting roadwidth less than 3.60 mt., the Floor Area Ratio-FAR shall be 1.2 {As per Rule No.39, Table 15, Note i}
(2) For Medininagar Nagar Parishad, Max. 2.5 permissible FAR may be permitted for Residential Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Residential Building on abutting roadwidth less than 3.60 mt., the Floor Area Ratio-FAR shall be 1.2 {As per Rule No.39, Table 15, Note i}
(2) For Medininagar Nagar Parishad, Max. 2.5 permissible FAR may be permitted for Residential Use {As per Annexure III}
Common Plot Area In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
Common Plot (1) In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
(2) ;
Tree Number 2-4 Trees shall be required for the Plot area upto 250.0 sq.mt. (As per Rule No. 20.1.6)
Margin Rule For Non-highrise Residential Building upto 10.0 mt. Ht. having Plot Depth 10-15 mt. and Plot width 10-15 mt., Margin required in Front shall be 2.0 mt., Rear 1.5 mt. and Atleast 0.9 mt. shall be provided at one side. {As per Rule No. 36 (Table 8 & 9)}
Building Line Check The min. width of Road for length of Road Exceeding 50 mt. and upto 100 mt. shall be 5.1 mt. {As per Rule No. 34 Table No. 6}
ResvRoad Width Check The min. width of Road for length of Road Exceeding 50 mt. and upto 100 mt. shall be 5.1 mt. {As per Rule No. 34 Table No. 6}
Building Level
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(3) The plinth or any part of a building shall be so located with respect to the surrounding ground level that adequate drainage of the site is assured. The height of the plinth (except in case of stilted parking) shall be not less than 0.45 mt. from the surrounding ground level {As per Rule No. 42.10}
Parapet Height Parapet walls and handrails provided on the edges of roof terraces, balcony, verandah, etc shall not be less than 1.0 m and not more than 1.2 m in height from the finished floor level {As per Rule No. 42.5}
Floor Number For old area location,on Road width upto 3.6 mt. only G+1 floors shall be allowed {As per Rule No. 39.1 Note 1}
StairCase (1) Width of Winding staircase shall be mini. 0.75 mt.,Maximum rise 0.20 mt. & Minimum tread 0.225 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
Plot / Building Level
Accessory Use (1) Common toilet of maximum size of 5 sq.mt shall be taken Free from FAR
(2) No need to check distance from Building Toilet
(3) -
(4) No need to check distance from Building SUMP TANK
(5) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(6) No need to check distance from Building RAIN WATER HARVESTING
Building Level (Rooms)