No Image Found

Detail Scrutiny Report

Medininagar Nagar Parishad

Version Number: 1.0.35
Version Date: 13/03/2019
Report Generated On: 12-04-2019
[-] Collapse All


General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictPALAMU
AuthorityMEDININAGAR NAGAR PARISHAD
Inward_NoMNNP/BP/0008/W10/2019
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentNew
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillageSudna
Taluka27
Architect Details
Architect NameMD FAIZ KHAN
License No.MNNP/ENG/0004/2017
Architect AddressMd Faiz khan S/o-Abdul Mannan Khan bhatti mohalla Daltonganj
Architect EmailIDthedesigngroup786@gmail.com
Architect Mobile No9471145786
Plot Details
Plot Use Residential
Plot SubUse Bungalow/ Dwelling / Non Apartment
PlotNearbyReligiousStructure NA
Plot/SubPlot No416
North -
South -
East -
WestRoad Width - 3.64
Owner's Details
NameSANGEETA KUMARI
AddressMAHENDRA HIGHT COLONY SUDNA
Email IDpremlic50@gmail.com
Mobile No7488425427
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 63.98
2 Plot area as per Document by Applicant 63.98
3 Physical area measured at site 63.98
4 Area as per Site Visit (Site Visit Report) 60.72
5Area as per Drawing 60.56

Area of Plot Considered : 60.56

[-] Table 2b
Proposal Detail :
UnitMeters
Development Detail :
PlotPLOT
Plot OccupancyResidential
Plot SubUse Bungalow/ Dwelling / Non Apartment
Building StructureNon-Highrise
Building TypeSingle Detached House
Gross Plot Area 60.56
Deduction from Gross Plot area
- Surrender Free of Cost 7.09
7.09
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 53.47
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 47.40
Deductions for Balance Plot Area (from Gross Plot Area)
- Surrender Free of Cost 7.09
- Common Plot 6.07
13.16
Balance Plot Area 47.40

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 70.00 % ) 37.43
Proposed Coverage Area ( 50.02 % ) 26.75
Total Prop. Coverage Area ( 50.02 % ) 26.75
Balance coverage area ( 19.97 % ) 10.68
FAR CHECK
Perm. FAR Area ( 1.50 ) 90.84
Total Perm. FAR area 90.84
Residential FAR 53.51
Proposed FAR Area 53.51
Total Proposed FAR Area 53.51
Consumed FAR (Factor) 0.88
Balance FAR Area 37.33
BUA CHECK
Total Proposed BuiltUp Area 53.50


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Up to 50 meter -
Existing Road Width 3.65 3.65
Proposed Road Width as per Master Plan 0 -
Road Widening Width 0 1.50
Plot size (as per measurement) 60.72 60.56
[-] Extra Land Area Checks
Name Area Status
Reqd Prop
Extra Land - 0.00 OK


[-] Plot Level Checking (Table 3)

[-] Common Plot Checks (Table 3b)
Name Total Area Status
Reqd Prop
Common Plot 2.67 6.07 OK


[-] Common Plot Checks (Table 3b)
Name Minimum Area Coverage Area Width Angle Access Status
Reqd Prop Perm Prop Reqd Prop Reqd Prop
Tree Cover (Plantation) - 6.07 0.00 0.00 - 1.36 - 90.00 No Access Provided OK



[-] Tree Details (Table 3g)
Name Nos Of Trees Status
Reqd Prop
Tree 2 16 OK


[-] Building Details (Table 4)

[-] Building USE/SUBUSE Details Building USE/SUBUSE Details
Building Name Building Use Building SubUse Building Structure
A (B) Residential Residential Bldg/Apartment Non-Highrise


[-] Height Details (4a)



[-] Total Height (Table 4a-1)
Building Height Height (From GL) Height (From Street LVL) Status
Perm Prop
A (B) 9.48 6.00 6.00 6.00 OK



[-] Floor Height Check (Table 4a-2)
Building Name Floor Name Height Clear Height Beam Clear Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
A (B) First Floor 2.75 - 3.00 2.75 - 2.90 2.40 - 2.75 OK
Ground Floor 2.75 - 3.00 2.75 - 2.90 2.40 - 2.75 OK
Plinth 0.45 - 0.60 - - 0.60 - - 0.60 OK


[-] Parapet Height Check (Table 4a-2.1)
Building Name Floor Name Height Status
Reqd Perm Prop
A (B) Terrace Floor 1.00 1.20 1.00 OK

[-] Floor Number Check (Table 4a-4)
Building Name No. of Floors No. of Tenements Status
Perm Prop Perm Prop
A (B) G + 2 2 - 1 OK

[-] Coverage Check (Table 4b)
Permissible Proposed Status
37.43 26.75 OK
70% 50.02%

[-] Individual Coverage Check
Coverage Area Perm. Prop.
A-1 (B) - 26.75
Total Prop. Coverage Area - 26.75
Total Coverage Area 37.43 26.75

[-] FAR & Tenement Details (Table 4c-1)
Building No. of Same Bldg Total Built Up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
Resi.
A (B) 1 53.50 53.50 53.50 53.50 01
Grand Total : 1 53.50 53.50 53.50 53.50 01


[-] Buildingwise Floor FAR Details
Floor Name Building Name Total
A (B)
Proposed Built Up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Total Proposed Built Up Area (Sq.mt.) Total FAR Area (Sq.mt.)
Ground Floor 26.75 26.75 26.75 26.75
First Floor 26.75 26.75 26.75 26.75
Terrace Floor 0.00 0.00 0.00 0.00
Total : 53.50 53.50 53.50 53.50


[-] UnitBUA Table for Building :A (B) UnitBUA CALCULATION
FLOOR Name UnitBUA Type UnitBUA Area Carpet Area No. of Rooms No. of Tenement
FIRST FLOOR PLAN SPLIT A FLAT 0.00 0.00 1 0
GROUND FLOOR PLAN SPLIT A FLAT 36.47 35.95 1 1
Total: - - 36.47 35.95 2 1


[-] Building :A (B)
Floor Name Total Built Up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
Resi.
Ground Floor 26.75 26.75 26.75 26.75 01
First Floor 26.75 26.75 26.75 26.75 00
Terrace Floor 0.00 0.00 0.00 0.00 00
Total : 53.50 53.50 53.50 53.50 01
Total Number of Same Buildings : 1
Total : 53.50 53.50 53.50 53.50 01
[-] Table 4c-2

FARArea
Building FAR Area:53.51
Existing FAR Area :0.00
Perm.
90.84
Prop.
53.51
Status
OK




[-] Margin Checks (Table 5)
[-] Plot Margin (Table 5a)
Building / Wing Road Name Front Side Rear Side Side1 Side2 Status
Reqd. Prop. Reqd. Prop. Reqd. Prop. Reqd. Prop.
A-1 (B) ROAD WIDENING AREA(SURRENDERED FREE OF COST) 2.00 2.50 1.50 1.54 0.90 0.90 - 0.00 OK






[-] Inner Building Details (Table 6)


No OTS/Duct/VShaft/Balcony/Passage/Lift/Tenements Found.


[-] Parking Details (Table 7)


NO PARKING CHECK REQUIRED FOR SINGLE DWELLING UNIT. Residential Bldg/Apartment, In Building: A (B)


[-] Exemption Details (Table 8)



Not Required to Check StairCase Number Rule.


[-] Staircase Checks (Table 8a-1)


[-] For Building :A (B)
Floor Name StairCase Name Flight Width Tread Width Riser Height Riser No. On Flight Cabin Ht. Status
Reqd Prop Reqd Prop Perm Prop Perm Prop Reqd Perm Prop
FIRST FLOOR PLAN STAIRCASE 0.750 0.965 0.225 0.250 0.200 0.167 - 9 - - 0.000 OK
GROUND FLOOR PLAN STAIRCASE 0.750 0.965 0.225 0.250 0.200 0.167 - 9 - - 0.000 OK
TERRACE FLOOR PLAN STAIRCASE - 0.965 - 0.250 - 0.000 - 0 2.100 - 2.700 OK


[-] Accessory Use Check (Table 8d)
Accessory Use Name Area Width Depth Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
SUMP TANK - - 1.40 - - 0.78 - - 1.81 - - 0.00 OK
RAIN WATER HARVESTING - - 0.45 - - 0.38 - - 1.18 - - 0.00 OK
Overhead WaterTank - - 7.50 - - 2.10 - - 3.57 - - 0.00 OK




[-] Floor Details (Table 9)


[-] Building:A (B)


[-] Floor:FIRST FLOOR PLAN



All Dimensions and Area of all the Rooms on this Floor are as per the Rules.

[-] Floor:GROUND FLOOR PLAN



All Dimensions and Area of all the Rooms on this Floor are as per the Rules.




[-] Summary (Table 10)

Name Perm./Reqd. Proposed Status
Plot Area - 53.47 OK
Plot Width - 4.76 OK
Plot Depth - 11.23 OK
Access Width - 3.65 OK
Plot Frontage - 4.72 OK
Coverage Area 37.43 26.75 OK
FARArea
Bldg. FAR Area : 53.51
Sanctioned FAR Area :0.00
90.84 53.51 OK





[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use
Plot Width No rule provided for Min. Plot size for proposed Use
Plot Depth No rule provided for Min. Plot size for proposed Use
Access Width The minimum width of abutting road for any Building shall be with respect to Length of Road {As per Rule No. 34 Table No.6}
Plot Frontage No rule provided for Min. Plot size for proposed Use
FAR Area (1) In Old Area, for Residential Building on abutting roadwidth 3.60 (12 ft.) to 4.80 mt., the Floor Area Ratio-FAR shall be 1.5 {As per Rule No.39, Table 15}
(2) For Medininagar Nagar Parishad, Max. 2.5 permissible FAR may be permitted for Residential Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Residential Building on abutting roadwidth 3.60 (12 ft.) to 4.80 mt., the Floor Area Ratio-FAR shall be 1.5 {As per Rule No.39, Table 15}
(2) For Medininagar Nagar Parishad, Max. 2.5 permissible FAR may be permitted for Residential Use {As per Annexure III}
Common Plot Area In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
Common Plot (1) In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
(2) ;
Tree Number 2-4 Trees shall be required for the Plot area upto 250.0 sq.mt. (As per Rule No. 20.1.6)
Margin Rule For Non-highrise Residential Building upto 10.0 mt. Ht. having Plot Depth 10-15 mt. and Plot width 10-15 mt., Margin required in Front shall be 2.0 mt., Rear 1.5 mt. and Atleast 0.9 mt. shall be provided at one side. {As per Rule No. 36 (Table 8 & 9)}
Building Level
Building Height For old area, on Road width 3.6-4.8 mt., Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 10.0 mt. {As per Rule No. 39.1 Table 15}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(3) The plinth or any part of a building shall be so located with respect to the surrounding ground level that adequate drainage of the site is assured. The height of the plinth (except in case of stilted parking) shall be not less than 0.45 mt. from the surrounding ground level {As per Rule No. 42.10}
Parapet Height Parapet walls and handrails provided on the edges of roof terraces, balcony, verandah, etc shall not be less than 1.0 m and not more than 1.2 m in height from the finished floor level {As per Rule No. 42.5}
Floor Number For old area location,on Road width 3.6-4.8 mt. only G+2 floors shall be allowed {As per Rule No. 39.1 Table 15}
StairCase (1) Width of Winding staircase shall be mini. 0.75 mt.,Maximum rise 0.20 mt. & Minimum tread 0.225 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) Width of Winding staircase shall be mini. 0.75 mt.,Maximum rise 0.20 mt. & Minimum tread 0.225 mt. & Cabin height 2.1 mt {As per Rule No. 83.18}
(4) ; No Rule Defined
Plot / Building Level
Accessory Use (1) -
(2) No need to check distance from Building SUMP TANK
(3) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(4) No need to check distance from Building RAIN WATER HARVESTING
(5) -
(6) No need to check distance from Building Overhead WaterTank
Building Level (Rooms)