General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictPALAMU
AuthorityMEDININAGAR MUNICIPAL CORPORATION
Inward_NoMNNP/BP/0053/W25/2021/ALT2
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentAddition or Alteration
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillageRodma
Taluka27
Layout Sanction Date7/6/2021
Architect Details
Architect NameRANJIT KUMAR
License No.MNNP/ENG/0001/2016
Architect AddressSHANTI BHAVAN, HAMIDGANJ, DALTONGANJ
Architect EmailIDraj.vermak7@gmail.com
Architect Mobile No8709821879
Plot Details
Plot Use Residential
Plot SubUse Bungalow/ Dwelling / Non Apartment
PlotNearbyReligiousStructure NA
Plot/SubPlot No2686
North -
South -
East -
West -
Owner's Details
NameSUMITRA DEVI
AddressREDMA
Email IDSHIVPRASADSAHU@GMAIL.COM
Mobile No8051014949
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 344.10
2 Plot area as per Document by Applicant 344.10
3 Area as per Site Visit (Site Visit Report) 344.10
4Area as per Drawing 344.10

Area of Plot Considered : 344.10

[-] Table 2b
Proposal Detail :
Unit
Development Detail :
PlotPLOT
Plot OccupancyResidential
Plot SubUse Bungalow/ Dwelling / Non Apartment
Building StructureNon-Highrise
Building TypeSingle Detached House
Gross Plot Area 344.10
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 344.10
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 316.31
Deductions for Balance Plot Area (from Gross Plot Area)
- Common Plot 27.78
27.78
Balance Plot Area 316.31

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 60.00 % ) 206.46
Proposed Coverage Area ( 44.24 % ) 152.22
Total Prop. Coverage Area ( 44.24 % ) 152.22
Balance coverage area ( 15.76 % ) 54.24
FAR CHECK
Perm. FAR Area ( 2.500 ) 860.25
Total Perm. FAR area 860.25
Residential FAR 605.76
Proposed FAR Area 605.76
Total Proposed FAR Area 605.76
Consumed FAR (Factor) 1.76
Balance FAR Area 254.49
BUA CHECK
Total Proposed BuiltUp Area 605.76


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Exceeding 50 meter and upto 100 meter -
Existing Road Width 6.1 6.10
Proposed Road Width as per Master Plan 6.1 -
Road Widening Width 0 -
Plot size (as per measurement) 344.1 344.10
[-] Extra Land Area Checks
Name Area Status
Reqd Prop
Extra Land - 0.00 OK

     Extra Land Area Details
Name Description Unit Reqd Perm Proposed Status
Extra Land Area Details Extra Land Area - - 0.00 OK

     Plot Related Details
Name Description Unit Reqd Perm Proposed Status
PLOT Plot Area Sq.Mt. - - 344.10 OK
Plot Width Mt. - - 32.11 OK
Plot Depth Mt. - - 10.72 OK
Access Width Mt. - - 6.10 OK
Plot Frontage Mt. - - 31.69 OK
Coverage Area Sq.Mt. - 206.46 152.22 OK
FAR Area Sq.Mt. - 860.25 605.76 OK
Consumed FAR Sq.Mt. - 2.50 1.76 OK
Common Plot Checks Common Plot - Total Area Sq.Mt. 17.20 27.78 OK
Common Plot Tree Cover (Plantation) - Minimum Area Sq.Mt. - 27.78 OK
Tree Cover (Plantation) - Coverage Area Sq.Mt. - - OK
Tree Cover (Plantation) - Width Mt. - 0.90 OK
Tree Cover (Plantation) - Angle Degree - 76.36 OK
Tree Cover (Plantation) - Access Mt. - OK
Tree Tree - Nos Of Trees No. 4 5 OK
A-1 (BUILDING) Front Margin... 6.1 MRT WIDE ROAD Mt. 3.00 - 3.62 OK
Rear Margin Mt. 1.50 - 1.50 OK
Side1 Margin Mt. 2.50 - 2.50 OK
Side2 Margin Mt. 2.50 - 2.50 OK

     Building Related Details
Name Description Unit Reqd Perm Proposed Status
A (BUILDING) Height Mt. 12.77 11.46 OK
A (BUILDING) Third Floor - Height Mt. 2.75 - 2.85 OK
Third Floor - Clear Height Mt. 2.75 - 2.75 OK
Third Floor - Beam Clear Height Mt. 2.40 - 2.47 OK
Second Floor - Height Mt. 2.75 - 2.85 OK
Second Floor - Clear Height Mt. 2.75 - 2.75 OK
Second Floor - Beam Clear Height Mt. 2.40 - 2.47 OK
First Floor - Height Mt. 2.75 - 2.85 OK
First Floor - Clear Height Mt. 2.75 - 2.75 OK
First Floor - Beam Clear Height Mt. 2.40 - 2.47 OK
Ground Floor - Height Mt. 2.75 - 2.85 OK
Ground Floor - Clear Height Mt. 2.75 - 2.75 OK
Ground Floor - Beam Clear Height Mt. 2.40 - 2.47 OK
Plinth - Height Mt. 0.45 - 0.96 OK
Plinth - Clear Height Mt. - - 0.96 OK
Plinth - Beam Clear Height Mt. - - 0.96 OK
A (BUILDING) Terrace Floor - Height Mt. - - 1.00 OK
Terrace Floor - Clear Height Mt. - - 1.00 OK
Terrace Floor - Beam Clear Height Mt. - - 1.00 OK
A (BUILDING) No. of Floors No. G + 4 4 OK
No. of Tenements No. - 1 OK
TERRACE FLOOR PLAN STAIRCASE - Flight Width Mt. - 1.010 OK
STAIRCASE - Tread Width Mt. - 0.250 OK
STAIRCASE - Riser Height Mt. - - OK
STAIRCASE - Riser No. On Flight No. - - OK
STAIRCASE - Cabin Ht. Mt. - - 2.400 OK
THIRD FLOOR PLAN STAIRCASE - Flight Width Mt. 0.900 1.010 OK
STAIRCASE - Tread Width Mt. 0.250 0.250 OK
STAIRCASE - Riser Height Mt. 0.200 0.130 OK
STAIRCASE - Riser No. On Flight No. - 11 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
Toilet Area Sq.Mt. - 5.00 0.45 OK
Width Mt. - - 0.42 OK
Depth Mt. - - 1.08 OK
Height Mt. - - - OK
SUMP TANK Area Sq.Mt. - - 0.45 OK
Width Mt. - - 0.42 OK
Depth Mt. - - 1.08 OK
Height Mt. - - - OK
RAIN WATER HARVESTING Area Sq.Mt. - - 0.45 OK
Width Mt. - - 0.42 OK
Depth Mt. - - 1.08 OK
Height Mt. - - - OK
ENT.GATE Area Sq.Mt. - - 0.41 OK
Width Mt. - - 0.12 OK
Depth Mt. - - 3.60 OK
Height Mt. - - - OK
SOLAR HEATING SYSTEM Area Sq.Mt. - - 13.04 OK
Width Mt. - - 2.75 OK
Depth Mt. - - 4.75 OK
Height Mt. - - - OK
A (BUILDING) Rain Water Harvesting - No No. 1 - 1 OK
Solar Water Heating System - No No. 1 - 1 OK
Entrance Gate - No No. 1 - 1 OK
   
    All Rooms are as per Rule in Room Checking




[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Width No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Depth No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Access Width The minimum width of abutting road for any Building shall be with respect to Length of Road {As per Rule No. 34 Table No.6}
Plot Frontage No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
FAR Area (1) In Old Area, for Residential Building on abutting roadwidth 6.10 (20 ft.) to 7.5 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15 and modified as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
(2) For Medininagar Nagar Parishad, Max. 2.5 permissible FAR may be permitted for Residential Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Residential Building on abutting roadwidth 6.10 (20 ft.) to 7.5 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15 and modified as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
(2) For Medininagar Nagar Parishad, Max. 2.5 permissible FAR may be permitted for Residential Use {As per Annexure III}
Common Plot Area In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
Common Plot (1) In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
(2) ;
Tree Number 4-8 Trees shall be required for the Plot area above 250.0 and upto 1000.0 sq.mt. (As per Rule No. 20.1.6)
Margin Rule For Non-highrise Residential Building 10-13.3 mt. Ht. having Plot Depth 10-15 mt. and Plot width 27-33 mt., Margin required in Front shall be 3.0 mt., Rear 1.5 mt. and 2.5 mt. shall be provided on both side. {As per Rule No. 36 (Table 8 & 9)}
Building Level
Building Height For old area, on Road width 6.10-7.50 mt., Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 16.4 mt. {As per Rule No. 39.1 Table 15}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(3) The plinth or any part of a building shall be so located with respect to the surrounding ground level that adequate drainage of the site is assured. The height of the plinth (except in case of stilted parking) shall be not less than 0.45 mt. from the surrounding ground level {As per Rule No. 42.10}
Parapet Height (1) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
(2) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
(3) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
Floor Number For old area location,on Road width 6.1-7.5 mt. only G+4 floors shall be allowed {As per Rule No. 39.1 Table 15}
StairCase (1) No Rule Defined
(2) ; No Rule Defined
(3) Width of Winding staircase shall be mini. 0.90 mt.,Maximum rise 0.20 mt. & Minimum tread 0.25 mt. & Cabin Height 2.1 mt. {As per Rule No. 83.18}
(4) ; No Rule Defined
Plot / Building Level
Accessory Use (1) Common toilet of maximum size of 5 sq.mt shall be taken Free from FAR
(2) No need to check distance from Building Toilet
(3) -
(4) No need to check distance from Building SUMP TANK
(5) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(6) No need to check distance from Building RAIN WATER HARVESTING
(7) No need to check distance from Building ENT.GATE
(8) -
(9) No need to check distance from Building SOLAR HEATING SYSTEM
Accessory Use Number (1) Provision of Rain Water Harvesting shall be mandatory for any use {Updated as per JBBL, Amendment VIII dated 16/03/2021} Rain Water Harvesting
(2) For Individual residential buildings having more than 150 sq m. plinth area, Provisions of Solar Water Heating System shall be done Solar Water Heating System
(3) In case of buildings with a height of 15.0 meters and above or ground coverage more than 500 sqm., the main entrance to the premise shall not be less than 5 (five) meters i n width in order to allow easy access to fire engine Entrance Gate
Building Level (Rooms)