No Image Found   

Check List Report

Medininagar Municipal Corporation

Version Number: 1.0.62  
Version Date: 16/10/2020 
Report Generated On: 20-08-2022 
 

[-] Collapse All


General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictPALAMU
AuthorityMEDININAGAR MUNICIPAL CORPORATION
Inward_NoMNNP/BP/0212/W30/2022
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentNew
Location of Development AreaNew Area
City Area/TPScheme NoNA
VillageKundh
Taluka27
Architect Details
Architect NameMD FAIZ KHAN
License No.MNNP/ENG/0004/2017
Architect AddressKG SCHOOL ROAD SADIK MANZIL CHOK
Architect EmailIDthedesigngroup786@gmail.com
Architect Mobile No9471145786
Plot Details
Plot Use Residential
Plot SubUse Bungalow/ Dwelling / Non Apartment
PlotNearbyReligiousStructure NA
Plot/SubPlot No1427,1428,1429
North -
South -
East -
West -
Owner's Details
NameMD RASHID
AddressMUSLIM NAGAR MOUJA KUND DALTONGANJ
Email IDrashid97711@gmail.com
Mobile No9771184621
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 121.38
2 Plot area as per Document by Applicant 121.38
3 Area as per Site Visit (Site Visit Report) 121.30
4Area as per Drawing 120.70

Area of Plot Considered : 120.70

[-] Table 2b
Proposal Detail :
Unit
Development Detail :
PlotPLOT
Plot OccupancyResidential
Plot SubUse Bungalow/ Dwelling / Non Apartment
Building StructureNon-Highrise
Building TypeSingle Detached House
Gross Plot Area 120.70
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 120.70
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 107.76
Deductions for Balance Plot Area (from Gross Plot Area)
- Common Plot 12.94
12.94
Balance Plot Area 107.76

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 70.00 % ) 84.49
Proposed Coverage Area ( 57.28 % ) 69.14
Total Prop. Coverage Area ( 57.28 % ) 69.14
Balance coverage area ( 12.72 % ) 15.35
FAR CHECK
Perm. FAR Area ( 2.00 ) 241.40
Total Perm. FAR area 241.40
Residential FAR 206.73
Proposed FAR Area 206.73
Total Proposed FAR Area 206.73
Consumed FAR (Factor) 1.71
Balance FAR Area 34.67
BUA CHECK
Total Proposed BuiltUp Area 275.86


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Exceeding 50 meter and upto 100 meter -
Existing Road Width 6.1 6.10
Proposed Road Width as per Master Plan 6.1 -
Road Widening Width 0 -
Plot size (as per measurement) 121.3 120.70
[-] Extra Land Area Checks
Name Area Status
Reqd Prop
Extra Land - 0.00 OK

     Extra Land Area Details
Name Description Unit Reqd Perm Proposed Status
Extra Land Area Details Extra Land Area - - 0.00 OK

     Plot Related Details
Name Description Unit Reqd Perm Proposed Status
PLOT Plot Area Sq.Mt. - - 120.70 OK
Plot Width Mt. - - 7.12 OK
Plot Depth Mt. - - 16.95 OK
Access Width Mt. - - 6.10 OK
Plot Frontage Mt. - - 7.62 OK
Coverage Area Sq.Mt. - 84.49 69.14 OK
FAR Area Sq.Mt. - 241.40 206.73 OK
Consumed FAR Sq.Mt. - 2.00 1.71 OK
Common Plot Checks Common Plot - Total Area Sq.Mt. 6.03 12.94 OK
Common Plot Tree Cover (Plantation) - Minimum Area Sq.Mt. - 12.94 OK
Tree Cover (Plantation) - Coverage Area Sq.Mt. - - OK
Tree Cover (Plantation) - Width Mt. - 2.01 OK
Tree Cover (Plantation) - Angle Degree - 89.80 OK
Tree Cover (Plantation) - Access Mt. - OK
Tree Tree - Nos Of Trees No. 2 7 OK
A-1 (BUILDING) Front Margin... 6.10 MTR WIDE ROAD Access Road Mt. 2.50 - 3.92 OK
Rear Margin Mt. 1.50 - 1.85 OK
Side1 Margin Mt. 0.90 - 0.90 OK
Side2 Margin Mt. - - 0.00 OK
A-1 (BUILDING) Basement Front Margin... 6.10 MTR WIDE ROAD Access Road Mt. 2.50 - 3.92 OK
Basement Rear Margin Mt. 1.50 - 1.85 OK
Basement Side1 Margin Mt. 0.90 - 0.90 OK
Basement Side2 Margin Mt. - - 0.00 OK

     Building Related Details
Name Description Unit Reqd Perm Proposed Status
A (BUILDING) Height Mt. 13.07 9.00 OK
A (BUILDING) Second Floor - Height Mt. 2.75 - 3.00 OK
Second Floor - Clear Height Mt. 2.75 - 2.88 OK
Second Floor - Beam Clear Height Mt. 2.40 - 2.55 OK
First Floor - Height Mt. 2.75 - 3.00 OK
First Floor - Clear Height Mt. 2.75 - 2.88 OK
First Floor - Beam Clear Height Mt. 2.40 - 2.55 OK
Ground Floor - Height Mt. 2.75 - 3.00 OK
Ground Floor - Clear Height Mt. 2.75 - 2.88 OK
Ground Floor - Beam Clear Height Mt. 2.40 - 2.55 OK
Basement Floor - Height Mt. 2.40 - 3.00 OK
Basement Floor - Clear Height Mt. 2.40 - 2.88 OK
Basement Floor - Beam Clear Height Mt. 2.10 - 2.55 OK
A (BUILDING) Terrace Floor - Height Mt. - - 1.00 OK
A (BUILDING) Basement Floor - Height Below GL Mt. - 3.00 OK
Basement Floor - Area Sq.Mt. - 69.14 OK
Basement Floor - Ventilation Area (Sq.mt.) Sq.Mt. - - OK
A (BUILDING) Area Sq.Mt. - 69.14 OK
Status - OK
Total Area Sq.Mt. - 69.14 OK
A (BUILDING) No. of Basement Floor No. 1 1 OK
A (BUILDING) No. of Floors No. G + 4 3 OK
No. of Tenements No. - 1 OK
GROUND FLOOR PLAN STAIRCASE - Flight Width Mt. 0.900 1.010 OK
STAIRCASE - Tread Width Mt. 0.250 0.250 OK
STAIRCASE - Riser Height Mt. 0.200 0.150 OK
STAIRCASE - Riser No. On Flight No. - 10 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
TYPICAL - 1& 2 FLOOR PLAN STAIRCASE - Flight Width Mt. 0.900 1.010 OK
STAIRCASE - Tread Width Mt. 0.250 0.250 OK
STAIRCASE - Riser Height Mt. 0.200 0.150 OK
STAIRCASE - Riser No. On Flight No. - 10 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
TERRACE FLOOR PLAN STAIRCASE - Flight Width Mt. - 1.010 OK
STAIRCASE - Tread Width Mt. - 0.250 OK
STAIRCASE - Riser Height Mt. - - OK
STAIRCASE - Riser No. On Flight No. - - OK
STAIRCASE - Cabin Ht. Mt. - - 2.637 OK
Toilet Area Sq.Mt. - 5.00 0.77 OK
Width Mt. - - 0.52 OK
Depth Mt. - - 1.49 OK
Height Mt. - - - OK
SUMP TANK Area Sq.Mt. - - 1.09 OK
Width Mt. - - 0.79 OK
Depth Mt. - - 1.37 OK
Height Mt. - - - OK
RAIN WATER HARVESTING Area Sq.Mt. - - 0.48 OK
Width Mt. - - 0.53 OK
Depth Mt. - - 0.91 OK
Height Mt. - - - OK
ENT.GATE Area Sq.Mt. - - 2.55 OK
Width Mt. - - 0.67 OK
Depth Mt. - - 3.82 OK
Height Mt. - - - OK
SOLAR HEATING SYSTEM Area Sq.Mt. - - 1.16 OK
Width Mt. - - 0.82 OK
Depth Mt. - - 1.42 OK
Height Mt. - - - OK
A (BUILDING) Rain Water Harvesting - No No. 1 - 1 OK
PLOT 7.00 mt. long 1.00 mt. High 3.60 mt. Wide Ramp - Width Mt. 3.30 3.60 OK
7.00 mt. long 1.00 mt. High 3.60 mt. Wide Ramp - Depth Mt. 1.00 1.00 OK
7.00 mt. long 1.00 mt. High 3.60 mt. Wide Ramp - Slope Ratio 1.00 : 7.00 - 01 : 07 OK
Ramp No. A (BUILDING) - BASEMENT FLOOR PLAN - No. No. 1 1 OK
   
    All Rooms are as per Rule in Room Checking




[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Width No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Depth No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Access Width The minimum width of abutting road for any Building shall be with respect to Length of Road {As per Rule No. 34 Table No.6}
Plot Frontage No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
FAR Area (1) In New Area, for Residential Building on abutting roadwidth 6.10 (20 ft.) to 7.5 mt., the Floor Area Ratio-FAR shall be 2.0 {As per Rule No.39, Table 15}
(2) For Medininagar Nagar Parishad, Max. 2.5 permissible FAR may be permitted for Residential Use {As per Annexure III}
Consumed FAR (1) In New Area, for Residential Building on abutting roadwidth 6.10 (20 ft.) to 7.5 mt., the Floor Area Ratio-FAR shall be 2.0 {As per Rule No.39, Table 15}
(2) For Medininagar Nagar Parishad, Max. 2.5 permissible FAR may be permitted for Residential Use {As per Annexure III}
Common Plot Area In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
Common Plot (1) In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
(2) ;
Tree Number 2-4 Trees shall be required for the Plot area upto 250.0 sq.mt. (As per Rule No. 20.1.6)
Margin Rule For Non-highrise Residential Building upto 10.0 mt. Ht. having Plot Depth 15-21 mt. and Plot width 15-21 mt., Margin required in Front shall be 2.5 mt., Rear 1.5 mt. and Atleast 0.9 mt. shall be provided at one side. {As per Rule No. 36 (Table 8 & 9)}
Basement Margin Rule Basements/cellars may be permitted to be constructed leaving the prescribed set back/open space applicable to the building {As per Rule No. 48}
Building Level
Building Height For new area, on Road width 6.1-7.5 mt., Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 16.4 mt. {As per Rule No. 39.1 Table 16}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(3) o Every basement shall be in every part at least 2.4 m. in height from the floor to the soffit of the roof slab or ceiling and mini. Of 2.1 mr. below the soffit of beams {As per Rule No. 48}
Parapet Height Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
Below GL Floor Height ,
Basement Floor No. Individual residential and small commercial buildings, plot size upto minimum 750 Sq. Meter may have one basement {As per Rule No. 48}
Floor Number For new area location,on Road width 6.1-7.5 mt. only G+4 floors shall be allowed {As per Rule No. 39.1 Table 16}
StairCase (1) Width of Winding staircase shall be mini. 0.90 mt.,Maximum rise 0.20 mt. & Minimum tread 0.25 mt. & Cabin Height 2.1 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) No Rule Defined
(4) ; No Rule Defined
Ramp For parking spaces in basements and upper storey of parking floors,if car parking is less then 40, one ramp of minimum of 3.30m width if it is strait and 4.5m width if it is curved at any point and with minimum slope gradient of 1:7 for depth up to 1.8m and 1:10 for more than 1.8m depth shall be provided {As per Rule No. 41.8 and as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017} ;
Ramp No. For parking spaces in basements and upper storey of parking floors, if car parking is less then 40 one ramp of minimum of 3.30m width if it is straight and 4.50m width if it is curved shall be provided
Plot / Building Level
Accessory Use (1) Common toilet of maximum size of 5 sq.mt shall be taken Free from FAR
(2) No need to check distance from Building Toilet
(3) -
(4) No need to check distance from Building SUMP TANK
(5) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(6) No need to check distance from Building RAIN WATER HARVESTING
(7) No need to check distance from Building ENT.GATE
(8) -
(9) No need to check distance from Building SOLAR HEATING SYSTEM
Accessory Use Number Provision of Rain Water Harvesting shall be mandatory for any use {Updated as per JBBL, Amendment VIII dated 16/03/2021} Rain Water Harvesting
Building Level (Rooms)