No Image Found   

Detail Scrutiny Report

Medininagar Municipal Corporation

Version Number: 1.0.64  
Version Date: 16/10/2020 
Report Generated On: 26-11-2022 
 
[-] Collapse All


General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictPALAMU
AuthorityMEDININAGAR MUNICIPAL CORPORATION
Inward_NoMNNP/BP/0298/W03/2022
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentNew
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillageNimiya
Taluka27
Architect Details
Architect NameRANJIT KUMAR
License No.MNNP/ENG/0001/2016
Architect AddressSHANTI BHAVAN, HAMIDGANJ, DALTONGANJ
Architect EmailIDraj.vermak7@gmail.com
Architect Mobile No8709821879
Plot Details
Plot Use Residential
Plot SubUse Bungalow/ Dwelling / Non Apartment
PlotNearbyReligiousStructure NA
Plot/SubPlot No286
North -
South -
East -
West -
Owner's Details
NameChinta Devi
AddressNimia
Email IDp9382142@gmail.com
Mobile No7903936882
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 161.93
2 Plot area as per Document by Applicant 161.93
3 Area as per Site Visit (Site Visit Report) 161.60
4Area as per Drawing 161.93

Area of Plot Considered : 161.60

Plot area provided in drawing shall not be more than Plot area as per Document.
[-] Table 2b
Proposal Detail :
UnitMeters
Development Detail :
PlotPLOT
Plot OccupancyResidential
Plot SubUse Bungalow/ Dwelling / Non Apartment
Building StructureNon-Highrise
Building TypeSingle Detached House
Gross Plot Area 161.60
Deduction from Gross Plot area
- Surrender Free of Cost 12.31
12.31
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 149.29
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 137.19
Deductions for Balance Plot Area (from Gross Plot Area)
- Surrender Free of Cost 12.31
- Common Plot 12.11
24.41
Balance Plot Area 137.19

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 70.00 % ) 104.50
Proposed Coverage Area ( 69.84 % ) 104.26
Total Prop. Coverage Area ( 69.84 % ) 104.26
Balance coverage area ( 0.16 % ) 0.24
FAR CHECK
Perm. FAR Area ( 1.20 ) 193.92
Total Perm. FAR area 193.92
Residential FAR 208.52
Proposed FAR Area 208.52
Total Proposed FAR Area 208.52
Consumed FAR (Factor) 1.29
Balance FAR Area 0.00
Total Paid Proposed FAR Area 14.60
BUA CHECK
Total Proposed BuiltUp Area 208.52


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Exceeding 50 meter and upto 100 meter -
Existing Road Width 3.05 3.05
Proposed Road Width as per Master Plan 6.1 -
Road Widening Width 1.525 1.53
Plot size (as per measurement) 161.6 161.93
[-] Extra Land Area Checks
Name Area Status
Reqd Prop
Extra Land - 0.00 OK


[-] Plot Level Checking (Table 3)
   
[-] Common Plot Checks (Table 3b)
Name Total Area Status
Reqd Prop
Common Plot 7.46 12.11 OK


[-] Common Plot Checks (Table 3b)
Name Minimum Area Coverage Area Width Angle Access Status
Reqd Prop Perm Prop Reqd Prop Reqd Prop
Tree Cover (Plantation) - 12.11 0.00 0.00 - 1.50 - 90.00 No Access Provided OK


   
   
[-] Tree Details (Table 3g)
Name Nos Of Trees Status
Reqd Prop
Tree 2 4 OK
   
   
   
   
   


[-] Building Details (Table 4)
   
[-] Building USE/SUBUSE Details Building USE/SUBUSE Details
Building Name Building Use Building SubUse Building Structure
A (RESIDENTIAL) Residential Bungalow/ Dwelling / Non Apartment Non-Highrise
   
   
   
[-] Height Details (4a)



[-] Total Height (Table 4a-1)
Building Height (From GL) Height (From Street LVL) Status
A (RESIDENTIAL) 6.01 6.01 OK


   
   
[-] Floor Height Check (Table 4a-2)
Building Name Floor Name Height Clear Height Beam Clear Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
A (RESIDENTIAL) First Floor 2.75 - 3.00 2.75 - 2.87 2.40 - 2.75 OK
Ground Floor 2.75 - 3.00 2.75 - 2.87 2.40 - 2.75 OK
Plinth 0.45 - 0.91 - - 0.91 - - 0.91 OK


[-] Parapet Height Check (Table 4a-2.1)
Building Name Floor Name Height Status
Reqd Perm Prop
A (RESIDENTIAL) Terrace Floor - - 1.07 OK
   
   
   
[-] Floor Number Check (Table 4a-4)
Building Name No. of Floors No. of Tenements Status
Perm Prop Perm Prop
A (RESIDENTIAL) G + 1 2 - 2 OK

 
   
    [-] Coverage Check (Table 4b)
Permissible Proposed Status
104.50 104.26 OK
70% 69.84%

[-] Individual Coverage Check
Coverage Area Perm. Prop.
  A-1 (RESIDENTIAL) - 104.26
  Total Prop. Coverage Area - 104.26
  Total Coverage Area 104.50 104.26

[-] FAR & Tenement Details (Table 4c-1)
Building No. of Same Bldg Total Built Up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
Resi.
A (RESIDENTIAL) 1 208.52 208.52 208.52 208.52 02
Grand Total : 1 208.52 208.52 208.52 208.52 02


[-] Buildingwise Floor FAR Details
Floor Name Building Name Total
A (RESIDENTIAL)
Proposed Built Up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Total Proposed Built Up Area (Sq.mt.) Total FAR Area (Sq.mt.)
Ground Floor 104.26 104.26 104.26 104.26
First Floor 104.26 104.26 104.26 104.26
Terrace Floor 0.00 0.00 0.00 0.00
Total : 208.52 208.52 208.52 208.52


[-] UnitBUA Table for Building :A (RESIDENTIAL)
UnitBUA CALCULATION
FLOOR Name UnitBUA Type UnitBUA Area Carpet Area No. of Rooms No. of Tenement
GROUND FLOOR PLAN SPLIT A FLAT 94.83 94.44 6 1
FIRST FLOOR PLAN SPLIT B FLAT 94.83 94.44 6 1
Total: - - 189.66 188.88 12 2


[-] Building :A (RESIDENTIAL)
Floor Name Total Built Up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
Resi.
Ground Floor 104.26 104.26 104.26 104.26 01
First Floor 104.26 104.26 104.26 104.26 01
Terrace Floor 0.00 0.00 0.00 0.00 00
Total : 208.52 208.52 208.52 208.52 02
Total Number of Same Buildings : 1
Total : 208.52 208.52 208.52 208.52 02
[-] Table 4c-2

  FAR Area
Building FAR Area:208.52
Existing FAR Area :0.00
Perm.
193.92
Prop.
208.52
Status
Failed




[-] Margin Checks (Table 5)
   
[-] Plot Margin (Table 5a)
Building / Wing Road Name Front Side Rear Side Side1 Side2 Status
Reqd. Prop. Reqd. Prop. Reqd. Prop. Reqd. Prop.
A-1 (RESIDENTIAL) ROAD WIDENING AREA(SURRENDERED FREE OF COST) 2.50 2.50 1.50 1.50 - 0.00 0.90 0.90 OK


[-] BldgLine Margin (Table 5a-1)
Building/Wing Front Side Reqd. Prop. Main Road Name ResvRoad Name Reqd. Width Prop. Width Status
A-1 (RESIDENTIAL) BldgLine for 3.05 METER WIDE ROAD 1.02 4.03 3.05 METER WIDE ROAD ROAD WIDENING AREA(SURRENDERED FREE OF COST) 1.02 1.53 Ok





[-] Inner Building Details (Table 6)
   

No OTS/Duct/VShaft/Balcony/Passage/Lift/Tenements Found.
   


[-] Parking Details (Table 7)
   
[-] Required Parking(Table 7a)
Building Name Type SubUse Area (Sq.mt.) Units Car Visitors Car
Reqd. Prop. Reqd./Unit Reqd. Prop. Reqd./Unit Reqd. Prop.
A (RESIDENTIAL) Residential Bungalow/ Dwelling / Non Apartment > 0 1 2.00 1 2 - - - -
> 0 1 2.00 - - - 1 1 -
Total : - - - - 2 0 - 1 0

[-] Parking Check (Table 7b)
Vehicle Type Reqd. Prop. Status
No. Area No. Area
Total Car 2 25.00 0 0.00 FAILED
Total Visitor Parking 1 12.50 0 0.00 FAILED
Total 37.50 0.00 FAILED


   


[-] Exemption Details (Table 8)
   


Not Required to Check StairCase Number Rule.


[-] Staircase Checks (Table 8a-1)


[-] For Building :A (RESIDENTIAL)
Floor Name StairCase Name Flight Width Tread Width Riser Height Riser No. On Flight Cabin Ht. Status
Reqd Prop Reqd Prop Perm Prop Perm Prop Reqd Perm Prop
GROUND FLOOR PLAN STAIRCASE 0.750 1.010 0.225 0.250 0.200 0.136 - 11 - - 0.000 OK
TERRACE FLOOR PLAN STAIRCASE - 1.010 - 0.250 - 0.000 - 0 2.100 - 2.438 OK
FIRST FLOOR PLAN STAIRCASE 0.750 1.010 0.225 0.250 0.200 0.136 - 11 - - 0.000 OK

   
   
   
[-] Accessory Use Check (Table 8d)
Accessory Use Name Area Width Depth Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
Toilet - 5.00 0.72 - - 0.39 - - 1.84 - - 0.00 OK
SUMP TANK - - 0.72 - - 0.39 - - 1.84 - - 0.00 OK
RAIN WATER HARVESTING - - 0.72 - - 0.39 - - 1.84 - - 0.00 OK





[-] Accessory Use No. Checks
Building Name Accessory Use Name No Status
Reqd Perm Prop
A (RESIDENTIAL) Rain Water Harvesting 1 - 1 OK
   
   


[-] Floor Details (Table 9)
   

[-] Building:A (RESIDENTIAL)


[-] Floor:GROUND FLOOR PLAN



All Dimensions and Area of all the Rooms on this Floor are as per the Rules.

[-] Floor:FIRST FLOOR PLAN



All Dimensions and Area of all the Rooms on this Floor are as per the Rules.


   


[-] Summary (Table 10)
   
Name Perm./Reqd. Proposed Status
  Plot Area - 149.29 OK
  Plot Width - 8.07 OK
  Plot Depth - 18.54 OK
  Access Width - 3.05 OK
  Plot Frontage - 8.07 OK
  Coverage Area 104.50 104.26 OK
  FAR Area
Bldg. FAR Area : 208.52
Sanctioned FAR Area :0.00
193.92 208.52 Failed





[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Width No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Depth No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Access Width The minimum width of abutting road for any Building shall be with respect to Length of Road {As per Rule No. 34 Table No.6}
Plot Frontage No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
FAR Area (1) In Old Area, for Residential Building on abutting roadwidth less than 3.60 mt., the Floor Area Ratio-FAR shall be 1.2 {As per Rule No.39, Table 15, Note i}
(2) For Medininagar Nagar Parishad, Max. 2.5 permissible FAR may be permitted for Residential Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Residential Building on abutting roadwidth less than 3.60 mt., the Floor Area Ratio-FAR shall be 1.2 {As per Rule No.39, Table 15, Note i}
(2) For Medininagar Nagar Parishad, Max. 2.5 permissible FAR may be permitted for Residential Use {As per Annexure III}
Common Plot Area In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
Common Plot (1) In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
(2) ;
Tree Number 2-4 Trees shall be required for the Plot area upto 250.0 sq.mt. (As per Rule No. 20.1.6)
Margin Rule For Non-highrise Residential Building upto 10.0 mt. Ht. having Plot Depth 15-21 mt. and Plot width 15-21 mt., Margin required in Front shall be 2.5 mt., Rear 1.5 mt. and Atleast 0.9 mt. shall be provided at one side. {As per Rule No. 36 (Table 8 & 9)}
Building Line Check The min. width of Road for length of Road Exceeding 50 mt. and upto 100 mt. shall be 5.1 mt. {As per Rule No. 34 Table No. 6}
ResvRoad Width Check The min. width of Road for length of Road Exceeding 50 mt. and upto 100 mt. shall be 5.1 mt. {As per Rule No. 34 Table No. 6}
Building Level
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(3) The plinth or any part of a building shall be so located with respect to the surrounding ground level that adequate drainage of the site is assured. The height of the plinth (except in case of stilted parking) shall be not less than 0.45 mt. from the surrounding ground level {As per Rule No. 42.10}
Parapet Height Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
Floor Number For old area location,on Road width upto 3.6 mt. only G+1 floors shall be allowed {As per Rule No. 39.1 Note 1}
StairCase (1) Width of Winding staircase shall be mini. 0.75 mt.,Maximum rise 0.20 mt. & Minimum tread 0.225 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) Width of Winding staircase shall be mini. 0.75 mt.,Maximum rise 0.20 mt. & Minimum tread 0.225 mt. & Cabin height 2.1 mt {As per Rule No. 83.18}
(4) ; No Rule Defined
Plot / Building Level
Accessory Use (1) Common toilet of maximum size of 5 sq.mt shall be taken Free from FAR
(2) No need to check distance from Building Toilet
(3) -
(4) No need to check distance from Building SUMP TANK
(5) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(6) No need to check distance from Building RAIN WATER HARVESTING
Accessory Use Number Provision of Rain Water Harvesting shall be mandatory for any use {Updated as per JBBL, Amendment VIII dated 16/03/2021} Rain Water Harvesting
Building Level (Rooms)