No Image Found Failed List Report Medininagar Municipal Corporation
Version Number: 1.0.74
Version Date: 16/10/2020
Report Generated On: 11-11-2024 

[-] Collapse All


[-] Proposal Information (Table 1)
General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictPALAMU
AuthorityMEDININAGAR MUNICIPAL CORPORATION
Inward_NoMNNP/BP/0083/W18/2023/ALT2
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentAddition or Alteration
Location of Development AreaNew Area
City Area/TPScheme NoNA
VillageRedma
Taluka27
Layout Sanction Date1/7/2023
Architect Details
Architect NameSIDDTHARTHA PRIYADARSHI
License No.MNNP/ENG/0005/2020
Architect AddressASTHAPURAM COLONY , PIRRA,RATU,RANCHI
Architect EmailIDpriyadarshisidd@gmail.com
Architect Mobile No9155291124
Plot Details
Plot Use Residential
Plot SubUse Bungalow/ Dwelling / Non Apartment
PlotNearbyReligiousStructure NA
Plot/SubPlot No1833
North -
South -
East -
West -

[-]Owner/Applicant details
NameChotu Tiwari
AddressRedma
Email IDPRIYADARSHISIDD@GMAIL.COM
Mobile No9955087458
  [-] Plot Details (Table 2)
[-] Area From Document (Table 2a)
No. Form Area(Sq. Mt.)
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 74.17
2 Plot area as per Document by Applicant 74.17
3 Area as per Site Visit (Site Visit Report) 74.17
4Area as per Drawing 73.87

Area of Plot Considered : 73.87
[-] Table 2b
Proposal Detail :
Unit
Development Detail :
PlotPLOT
Plot OccupancyResidential
Plot SubUse Bungalow/ Dwelling / Non Apartment
Building StructureNon-Highrise
Building TypeSingle Detached House
Gross Plot Area 73.87
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 73.87
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 64.19
Deductions for Balance Plot Area (from Gross Plot Area)
- Common Plot 9.67
9.67
Balance Plot Area 64.19

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 60.00 % ) 44.32
Proposed Coverage Area ( 51.61 % ) 38.12
Total Prop. Coverage Area ( 51.61 % ) 38.12
Balance coverage area ( 8.39 % ) 6.20
FAR CHECK
Perm. FAR Area ( 2.500 ) 184.68
Total Perm. FAR area 184.68
Residential FAR 152.46
Proposed FAR Area 152.46
Total Proposed FAR Area 152.46
Consumed FAR (Factor) 2.06
Balance FAR Area 32.22
BUA CHECK
Total Proposed BuiltUp Area 152.48


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Exceeding 1000 meter -
Existing Road Width 24 24.00
Proposed Road Width as per Master Plan 24 -
Road Widening Width 0 -
Plot size (as per measurement) 74.17 73.87
[-] Extra Land Area Checks
Name Area Status
Reqd Prop
Extra Land - 0.00 OK



[-] Plot Miscellanies Details
No Rule Status
1 No construction shall be permitted for Building Height above 10.0 mt. or above G+2 in Plot having depth less than 10.0 mt. {As per Rule No. 36} Failed
[-] PWork to Plot Margin
Name Description Unit Reqd Perm Proposed Status
A-1 (BUILDING) Front Margin... 24 MTR WIDE ROAD Mt. 3.00 - 1.50 Failed
Rear Margin Mt. 1.50 - 0.90 Failed



NOTE : This report is generated based on the inputs or drawing provided by the Applicant. The approval is subjected to further verification by concerned scrutiny officer.
Accuracy of Scrutiny Report and Drawing is subject to accuracy of end-user provided data, 3rd party software/hardware/services, etc. We are not liable for any damages which may arise from use, or inability to use the Application.

[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Width No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Depth No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Access Width The minimum width of abutting road for any Building shall be with respect to Length of Road {As per Rule No. 34 Table No.6}
Plot Frontage No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
FAR Area (1) In New Area, for Residential Building on abutting roadwidth 18.30 (60 ft.) to 24.40 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15}
(2) For Medininagar Nagar Parishad, Max. 2.5 permissible FAR may be permitted for Residential Use {As per Annexure III}
Consumed FAR (1) In New Area, for Residential Building on abutting roadwidth 18.30 (60 ft.) to 24.40 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15}
(2) For Medininagar Nagar Parishad, Max. 2.5 permissible FAR may be permitted for Residential Use {As per Annexure III}
Common Plot Area In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
Common Plot (1) In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
(2) ;
Tree Number 2-4 Trees shall be required for the Plot area upto 250.0 sq.mt. (As per Rule No. 20.1.6)
Margin Rule For Non-highrise Residential Building 10-13.3 mt. Ht. having Plot Depth upto 10 mt. and Plot width 10-15 mt., Margin required in Front shall be 3.0 mt., Rear 1.5 mt. and 0.9 mt. shall be provided on both side. {As per Rule No. 36 (Table 8 & 9)}
Building Level
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
Parapet Height (1) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
(2) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
(3) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
Floor Number No Rule Defined
StairCase (1) No Rule Defined
(2) ; No Rule Defined
(3) Width of Winding staircase shall be mini. 0.90 mt.,Maximum rise 0.20 mt. & Minimum tread 0.25 mt. & Cabin Height 2.1 mt. {As per Rule No. 83.18}
(4) ; No Rule Defined
Plot / Building Level
Accessory Use (1) Common toilet of maximum size of 5 sq.mt shall be taken Free from FAR
(2) No need to check distance from Building Toilet
(3) -
(4) No need to check distance from Building SUMP TANK
(5) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(6) No need to check distance from Building RAIN WATER HARVESTING
(7) -
(8) No need to check distance from Building SOLAR HEATING SYSTEM
Accessory Use Number Provision of Rain Water Harvesting shall be mandatory for any use {Updated as per JBBL, Amendment VIII dated 16/03/2021} Rain Water Harvesting
Building Level (Rooms)
Kitchen2.52x2.41 Area for Kitchen shall be Mini. 5.0 sq.mt. having side mini. 1.8 mt. {Rule No. 42.3.2}
Room2.94x3.44 No Rule Defined
Room3.84x3.44 No Rule Defined
Toilet1.20x2.41 Area for Toilet shall be Mini. 2.8 sq.mt. having side mini. 1.2 mt. {Rule No. 42.4.2}