[-] Proposal Information (Table 1)
General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictPALAMU
AuthorityMEDININAGAR MUNICIPAL CORPORATION
Inward_NoMNNP/BP/0083/W18/2023/ALT2
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentAddition or Alteration
Location of Development AreaNew Area
City Area/TPScheme NoNA
VillageRedma
Taluka27
Layout Sanction Date1/7/2023
Architect Details
Architect NameSIDDTHARTHA PRIYADARSHI
License No.MNNP/ENG/0005/2020
Architect AddressASTHAPURAM COLONY , PIRRA,RATU,RANCHI
Architect EmailIDpriyadarshisidd@gmail.com
Architect Mobile No9155291124
Plot Details
Plot Use Residential
Plot SubUse Bungalow/ Dwelling / Non Apartment
PlotNearbyReligiousStructure NA
Plot/SubPlot No1833
North -
South -
East -
West -

[-]Owner/Applicant details
NameChotu Tiwari
AddressRedma
Email IDPRIYADARSHISIDD@GMAIL.COM
Mobile No9955087458
  [-] Plot Details (Table 2)
[-] Area From Document (Table 2a)
No. Form Area(Sq. Mt.)
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 74.17
2 Plot area as per Document by Applicant 74.17
3 Area as per Site Visit (Site Visit Report) 74.17
4Area as per Drawing 73.87

Area of Plot Considered : 73.87
[-] Table 2b
Proposal Detail :
UnitMeters
Development Detail :
PlotPLOT
Plot OccupancyResidential
Plot SubUse Bungalow/ Dwelling / Non Apartment
Building StructureNon-Highrise
Building TypeSingle Detached House
Gross Plot Area 73.87
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 73.87
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 64.19
Deductions for Balance Plot Area (from Gross Plot Area)
- Common Plot 9.67
9.67
Balance Plot Area 64.19

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 60.00 % ) 44.32
Proposed Coverage Area ( 51.61 % ) 38.12
Total Prop. Coverage Area ( 51.61 % ) 38.12
Balance coverage area ( 8.39 % ) 6.20
FAR CHECK
Perm. FAR Area ( 2.500 ) 184.68
Total Perm. FAR area 184.68
Residential FAR 152.46
Proposed FAR Area 152.46
Total Proposed FAR Area 152.46
Consumed FAR (Factor) 2.06
Balance FAR Area 32.22
BUA CHECK
Total Proposed BuiltUp Area 152.48


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Exceeding 1000 meter -
Existing Road Width 24 24.00
Proposed Road Width as per Master Plan 24 -
Road Widening Width 0 -
Plot size (as per measurement) 74.17 73.87
[-] Extra Land Area Checks
Name Area Status
Reqd Prop
Extra Land - 0.00 OK


[-] Plot Level Checking (Table 3)

[-] Common Plot Checks (Table 3b)
Name Total Area Status
Reqd Prop
Common Plot 3.69 9.67 OK


[-] Common Plot Checks (Table 3b)
Name Minimum Area Coverage Area Width Angle Access Status
Reqd Prop Perm Prop Reqd Prop Reqd Prop
Tree Cover (Plantation) - 9.67 0.00 0.00 - 0.86 - 81.60 No Access Provided OK



[-] Tree Details (Table 3g)
Name Nos Of Trees Status
Reqd Prop
Tree 2 6 OK
[-] Plot Miscellanies Checks

No Rule Status
1 No construction shall be permitted for Building Height above 10.0 mt. or above G+2 in Plot having depth less than 10.0 mt. {As per Rule No. 36} Failed


[-] Building Details (Table 4)

[-] Building USE/SUBUSE Details
Building Name Building Use Building SubUse Building Structure No Of Residential Units Floor Name Floor Use Floor SubUse FAR Name FAR Use FAR SubUse
A (BUILDING) Residential Bungalow/ Dwelling / Non Apartment Non-Highrise 1 FIRST FLOOR PLAN Residential Bungalow/ Dwelling / Non Apartment Residential FAR Residential Bungalow/ Dwelling / Non Apartment
GROUND FLOOR PLAN Residential Bungalow/ Dwelling / Non Apartment Residential FAR Residential Bungalow/ Dwelling / Non Apartment
TERRACE FLOOR PLAN Residential Bungalow/ Dwelling / Non Apartment - - -
TYPICAL -2&3 FLOOR PLAN Residential Bungalow/ Dwelling / Non Apartment Residential FAR Residential Bungalow/ Dwelling / Non Apartment


[-] Total Height (Table 4a-1)
Building Height (From GL) Height (From Street LVL) Status
A (BUILDING) 11.40 11.40 OK



[-] Floor Height Check (Table 4a-2)
Building Name Floor Name Height Clear Height Beam Clear Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
A (BUILDING) Third Floor 2.75 - 2.85 2.75 - 2.75 2.40 - 2.60 OK
Second Floor 2.75 - 2.85 2.75 - 2.75 2.40 - 2.60 OK
First Floor 2.75 - 2.85 2.75 - 2.75 2.40 - 2.60 OK
Ground Floor 2.75 - 2.85 2.75 - 2.75 2.40 - 2.60 OK


[-] Parapet Height Check (Table 4a-2.1)
Building Name Floor Name Height Clear Height Beam Clear Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
A (BUILDING) Terrace Floor - - 1.00 - - 1.00 - - 1.00 OK

[-] Floor Number Check (Table 4a-4)
Building Name No. of Floors No. of Tenements Status
Perm Prop Perm Prop
A (BUILDING) - 4 - 1 OK

  [-] Coverage Check (Table 4b)
Permissible Proposed Status
44.32 38.12 OK
60% 51.61%

[-] Individual Coverage Check
Coverage Area Perm. Prop.
  A-1 (BUILDING) - 38.12
  Total Prop. Coverage Area - 38.12
  Total Coverage Area 44.32 38.12

[-] FAR & Tenement Details
Building No. of Same Bldg Total Built Up Area (Sq.mt.) Existing Built Up Area (Sq.mt.) Proposed Built Up Area (Sq.mt.) Existing FAR Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
Resi.
A (BUILDING) 1 152.48 76.24 76.24 76.24 76.24 152.48 152.48 01
Grand Total : 1 152.48 76.24 76.24 76.24 76.24 152.48 152.48 01


[-] Buildingwise Floor FAR Details
Floor Name Building Name Total
A (BUILDING)
Proposed Built Up Area (Sq.mt.) Existing Built up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Existing FAR Area (Sq.mt.) Total Proposed Built Up Area (Sq.mt.) Total Existing Built up Area (Sq.mt.) Total FAR Area (Sq.mt.) Total Existing FAR Area (Sq.mt.)
Ground Floor 0.00 38.12 0.00 38.12 0.00 38.12 0.00 38.12
First Floor 0.00 38.12 0.00 38.12 0.00 38.12 0.00 38.12
Second Floor 38.12 0.00 38.12 0.00 38.12 0.00 38.12 0.00
Third Floor 38.12 0.00 38.12 0.00 38.12 0.00 38.12 0.00
Terrace Floor 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Total : 76.24 76.24 76.24 76.24 76.24 76.24 76.24 76.24


[-] UnitBUA Table for Building :A (BUILDING)
UnitBUA CALCULATION
FLOOR Name UnitBUA Type Entity Type UnitBUA Area Carpet Area No. of Rooms No. of Tenement
FIRST FLOOR PLAN SPLIT A FLAT Existing 0.00 0.00 4 0
GROUND FLOOR PLAN SPLIT A FLAT Existing 105.60 105.54 2 1
TYPICAL -2&3 FLOOR PLAN SPLIT A FLAT Proposed 0.00 0.00 4 0
Total: - - - 105.60 105.54 14 1


[-] Building :A (BUILDING)
Floor Name Total Built Up Area (Sq.mt.) Existing Built Up Area (Sq.mt.) Proposed Built Up Area (Sq.mt.) Existing FAR Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
Resi.
Ground Floor 38.12 38.12 0.00 38.12 0.00 38.12 38.12 01
First Floor 38.12 38.12 0.00 38.12 0.00 38.12 38.12 00
Second Floor 38.12 0.00 38.12 0.00 38.12 38.12 38.12 00
Third Floor 38.12 0.00 38.12 0.00 38.12 38.12 38.12 00
Terrace Floor 0.00 0.00 0.00 0.00 0.00 0.00 0.00 00
Total : 152.48 76.24 76.24 76.24 76.24 152.48 152.48 01
Total Number of Same Buildings : 1
Total : 152.48 76.24 76.24 76.24 76.24 152.48 152.48 01

[-] Table 4c-2
  FAR Area Perm. Prop. Status
Building FAR Area : 152.46
Existing FAR Area : 0.00
184.68 152.46 OK



[-] Mandatory setbacks Checks (Table 5)
[-] Plot Mandatory setbacks (Table 5a)
Building / Wing Road Name Front Side Rear Side Side1 Side2 Status
Reqd. Prop. Reqd. Prop. Reqd. Prop. Reqd. Prop.
A-1 (BUILDING) 24 MTR WIDE ROAD 3.00 1.50 1.50 0.90 0.90 0.90 0.90 0.90 Failed




[-] Inner Building Details (Table 6)


No OTS/Duct/VShaft/Balcony/Passage/Lift/Tenements Found.

[-] Parking Details (Table 7)


NO PARKING CHECK REQUIRED FOR SINGLE DWELLING UNIT. Bungalow/ Dwelling / Non Apartment, In Building: A (BUILDING)

[-] Exemption Details (Table 8)


Not Required to Check StairCase Number Rule.


[-] Staircase Checks (Table 8a-1)


[-] For Building :A (BUILDING)
Floor Name StairCase Name Flight Width Tread Width Riser Height Riser No. On Flight Cabin Ht. Status
Reqd Prop Reqd Prop Perm Prop Perm Prop Reqd Perm Prop
TERRACE FLOOR PLAN STAIRCASE - 0.900 - 0.250 - 0.000 - 0 - - 2.646 OK
TYPICAL -2&3 FLOOR PLAN STAIRCASE 0.900 0.900 0.250 0.250 0.200 0.150 - 7 - - 0.000 OK


[-] Accessory Use Check (Table 8d)
Accessory Use Name Area Width Depth Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
Toilet - 5.00 0.52 - - 0.55 - - 0.95 - - 0.00 OK
SUMP TANK - - 0.52 - - 0.55 - - 0.95 - - 0.00 OK
RAIN WATER HARVESTING - - 0.42 - - 0.55 - - 0.76 - - 0.00 OK
SOLAR HEATING SYSTEM - - 2.14 - - 1.11 - - 1.93 - - 0.00 OK





[-] Accessory Use No. Checks
Building Name Accessory Use Name No Status
Reqd Perm Prop
A (BUILDING) Rain Water Harvesting 1 - 1 OK

[-] Floor Details (Table 9)



[-] Building:A (BUILDING)


[-] Floor:FIRST FLOOR PLAN



No Room Found.

[-] Floor:GROUND FLOOR PLAN



No Room Found.

[-] Floor:TYPICAL -2&3 FLOOR PLAN



All Dimensions and Area of all the Rooms on this Floor are as per the Rules.



[-] Summary (Table 4)
Name Perm./Reqd. Proposed Status
  Plot Area - 73.87 OK
  Plot Width - 12.13 OK
  Plot Depth - 6.09 OK
  Access Width - 24.00 OK
  Plot Frontage - 12.13 OK
  Coverage Area 44.32 38.12 OK
  FAR Area
Bldg. FAR Area : 152.46
Sanctioned FAR Area :0.00
184.68 152.46 OK




NOTE : This report is generated based on the inputs or drawing provided by the Applicant. The approval is subjected to further verification by concerned scrutiny officer.
Accuracy of Scrutiny Report and Drawing is subject to accuracy of end-user provided data, 3rd party software/hardware/services, etc. We are not liable for any damages which may arise from use, or inability to use the Application.

[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Width No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Depth No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Access Width The minimum width of abutting road for any Building shall be with respect to Length of Road {As per Rule No. 34 Table No.6}
Plot Frontage No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
FAR Area (1) In New Area, for Residential Building on abutting roadwidth 18.30 (60 ft.) to 24.40 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15}
(2) For Medininagar Nagar Parishad, Max. 2.5 permissible FAR may be permitted for Residential Use {As per Annexure III}
Consumed FAR (1) In New Area, for Residential Building on abutting roadwidth 18.30 (60 ft.) to 24.40 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15}
(2) For Medininagar Nagar Parishad, Max. 2.5 permissible FAR may be permitted for Residential Use {As per Annexure III}
Common Plot Area In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
Common Plot (1) In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
(2) ;
Tree Number 2-4 Trees shall be required for the Plot area upto 250.0 sq.mt. (As per Rule No. 20.1.6)
Margin Rule For Non-highrise Residential Building 10-13.3 mt. Ht. having Plot Depth upto 10 mt. and Plot width 10-15 mt., Margin required in Front shall be 3.0 mt., Rear 1.5 mt. and 0.9 mt. shall be provided on both side. {As per Rule No. 36 (Table 8 & 9)}
Building Level
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
Parapet Height (1) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
(2) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
(3) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
Floor Number No Rule Defined
StairCase (1) No Rule Defined
(2) ; No Rule Defined
(3) Width of Winding staircase shall be mini. 0.90 mt.,Maximum rise 0.20 mt. & Minimum tread 0.25 mt. & Cabin Height 2.1 mt. {As per Rule No. 83.18}
(4) ; No Rule Defined
Plot / Building Level
Accessory Use (1) Common toilet of maximum size of 5 sq.mt shall be taken Free from FAR
(2) No need to check distance from Building Toilet
(3) -
(4) No need to check distance from Building SUMP TANK
(5) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(6) No need to check distance from Building RAIN WATER HARVESTING
(7) -
(8) No need to check distance from Building SOLAR HEATING SYSTEM
Accessory Use Number Provision of Rain Water Harvesting shall be mandatory for any use {Updated as per JBBL, Amendment VIII dated 16/03/2021} Rain Water Harvesting
Building Level (Rooms)
Kitchen2.52x2.41 Area for Kitchen shall be Mini. 5.0 sq.mt. having side mini. 1.8 mt. {Rule No. 42.3.2}
Room2.94x3.44 No Rule Defined
Room3.84x3.44 No Rule Defined
Toilet1.20x2.41 Area for Toilet shall be Mini. 2.8 sq.mt. having side mini. 1.2 mt. {Rule No. 42.4.2}