-
No Image Found   

Detail Scrutiny Report

Medininagar Municipal Corporation

Version Number: 1.0.70  
Version Date: 16/10/2020 
Report Generated On: 15-05-2024 
 
[-] Collapse All


General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictPALAMU
AuthorityMEDININAGAR MUNICIPAL CORPORATION
Inward_NoMNNP/BP/0133/W03/2024
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentNew
Location of Development AreaNew Area
City Area/TPScheme NoNA
VillageSudma Bariya
Taluka27
Architect Details
Architect NamePANKAJ KUMAR SINGH
License No.MNNP/ENG/0006/2019
Architect AddressC/O PANKAJ KUMAR SINGH,HOUSE NO 28,NEAR BRIGHT LAND SCHOO BYE PASS ROAD ,ABADGANJ,DALTONGANJ,PALAMAU,JHARKHAND.
Architect EmailIDpankaj4870@gmail.com
Architect Mobile No8709050386
Plot Details
Plot Use Residential
Plot SubUse Bungalow/ Dwelling / Non Apartment
PlotNearbyReligiousStructure NA
Plot/SubPlot No53
North -
South -
East -
West -
Owner's Details
NameNirmala Devi
AddressBairiya
Email IDpankaj4870@gmail.com
Mobile No8709050386
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 768.74
2 Plot area as per Document by Applicant 768.74
3 Area as per Site Visit (Site Visit Report) 768.74
4Area as per Drawing 748.90

Area of Plot Considered : 748.90

[-] Table 2b
Proposal Detail :
UnitMeters
Development Detail :
PlotPLOT
Plot OccupancyResidential
Plot SubUse Bungalow/ Dwelling / Non Apartment
Building StructureNon-Highrise
Building TypeSingle Detached House
Gross Plot Area 748.90
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 748.90
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 686.84
Deductions for Balance Plot Area (from Gross Plot Area)
- Common Plot 62.05
62.05
Balance Plot Area 686.84

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 60.00 % ) 449.34
Proposed Coverage Area ( 41.65 % ) 311.88
Total Prop. Coverage Area ( 41.65 % ) 311.88
Balance coverage area ( 18.35 % ) 137.46
FAR CHECK
Perm. FAR Area ( 2.500 ) 1872.25
Total Perm. FAR area 1872.25
Residential FAR 1546.48
Proposed FAR Area 1561.93
Total Proposed FAR Area 1561.93
Consumed FAR (Factor) 2.09
Balance FAR Area 310.32
BUA CHECK
Total Proposed BuiltUp Area 1871.28


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Exceeding 1000 meter -
Existing Road Width 6.1 9.10
Proposed Road Width as per Master Plan 6.1 -
Road Widening Width 0 -
Plot size (as per measurement) 768.74 748.90

[-] Road width Details Checks
No Rule Status
1 For Existing Road Width, value as per site visit and value as per drawing should be same. Failed
[-] Extra Land Area Checks
Name Area Status
Reqd Prop
Extra Land - 0.00 OK


[-] Plot Level Checking (Table 3)
   
[-] Common Plot Checks (Table 3b)
Name Total Area Status
Reqd Prop
Common Plot 37.45 62.05 OK


[-] Common Plot Checks (Table 3b)
Name Minimum Area Coverage Area Width Angle Access Status
Reqd Prop Perm Prop Reqd Prop Reqd Prop
Tree Cover (Plantation) - 62.05 0.00 0.00 - 2.54 - 69.59 No Access Provided OK


   
   
[-] Tree Details (Table 3g)
Name Nos Of Trees Status
Reqd Prop
Tree 4 6 OK
   
   
   
   
   


[-] Building Details (Table 4)
   
[-] Building USE/SUBUSE Details Building USE/SUBUSE Details
Building Name Building Use Building SubUse Building Structure
A (BUILDING) Residential Bungalow/ Dwelling / Non Apartment Non-Highrise
   
   
   
[-] Height Details (4a)



[-] Total Height (Table 4a-1)
Building Height Height (From GL) Height (From Street LVL) Status
Perm Prop
A (BUILDING) 23.10 15.00 15.00 15.00 OK


   
   
[-] Floor Height Check (Table 4a-2)
Building Name Floor Name Height Clear Height Beam Clear Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
A (BUILDING) Fourth Floor 2.75 - 3.00 2.75 - 2.90 2.40 - 2.75 OK
Third Floor 2.75 - 3.00 2.75 - 2.90 2.40 - 2.75 OK
Second Floor 2.75 - 3.00 2.75 - 2.90 2.40 - 2.75 OK
First Floor 2.75 - 3.00 2.75 - 2.90 2.40 - 2.75 OK
Ground Floor 2.75 - 3.00 2.75 - 2.90 2.40 - 2.75 OK
Basement Floor 2.40 - 3.00 2.40 - 2.90 2.10 - 2.75 OK


[-] Parapet Height Check (Table 4a-2.1)
Building Name Floor Name Height Clear Height Beam Clear Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
A (BUILDING) Terrace Floor - - 1.00 - - 1.00 - - 1.00 OK
   
   
[-] Basement Floor Check (Table 4a-3)
Building Name Floor Name Height of Basement Floor above GL Area Ventilation Area Status
Reqd Perm Prop Perm Prop Reqd Prop
A (BUILDING) Basement Floor - - 0.00 - 311.88 - 0.00 OK


[-] Basement Floor Area Check
Building Name Area Status
Perm Prop
A (BUILDING) - 311.88
Total - 311.88 OK

1 [-] Basement Margin Check
Building / Wing Road Name Front Side Rear Side Side1 Side2 Status
Reqd. Prop. Reqd. Prop. Reqd. Prop. Reqd. Prop.
  A-1 (BUILDING)   9.1 MTR WIDE MAIN ROAD 6.00 35.13 5.00 3.00 1.00 1.00 1.00 1.00 Failed

    >
   
   
[-] Floor Number Check (Table 4a-4)
Building Name No. of Floors No. of Tenements Status
Perm Prop Perm Prop
A (BUILDING) G + 6 5 - 1 OK


[-] Basement Floor Number Check
Building Name No. of Basement Floor Status
Perm Prop
A (BUILDING) 1 1 OK
 
   
    [-] Coverage Check (Table 4b)
Permissible Proposed Status
449.34 311.88 OK
60% 41.65%

[-] Individual Coverage Check
Coverage Area Perm. Prop.
  A-1 (BUILDING) - 311.88
  Total Prop. Coverage Area - 311.88
  Total Coverage Area 449.34 311.88

[-] FAR & Tenement Details (Table 4c-1)
Building No. of Same Bldg Total Built Up Area (Sq.mt.) Deductions (Area in Sq.mt.) Proposed FAR Area (Sq.mt.) Add Area In FAR (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
Lift Parking Resi. Stair
A (BUILDING) 1 1871.28 16.15 253.20 1546.48 15.45 1561.93 1561.93 01
Grand Total : 1 1871.28 16.15 253.20 1546.48 15.45 1561.93 1561.93 01


[-] Buildingwise Floor FAR Details
Floor Name Building Name Total
A (BUILDING)
Proposed Built Up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Total Proposed Built Up Area (Sq.mt.) Total FAR Area (Sq.mt.)
Basement Floor 311.88 15.45 311.88 15.45
Ground Floor 311.88 311.88 311.88 311.88
First Floor 311.88 308.65 311.88 308.65
Second Floor 311.88 308.65 311.88 308.65
Third Floor 311.88 308.65 311.88 308.65
Fourth Floor 311.88 308.65 311.88 308.65
Terrace Floor 0.00 0.00 0.00 0.00
Total : 1871.28 1561.93 1871.28 1561.93


[-] UnitBUA Table for Building :A (BUILDING)
UnitBUA CALCULATION
FLOOR Name UnitBUA Type UnitBUA Area Carpet Area No. of Rooms No. of Tenement
GROUND FLOOR PLAN SPLIT A FLAT 1446.62 1446.31 2 1
TYPICAL -1,2,3&4 FLOOR PLAN SPLIT A FLAT 0.00 0.00 7 0
Total: - - 1446.62 1446.31 30 1


[-] Building :A (BUILDING)
Floor Name Total Built Up Area (Sq.mt.) Deductions (Area in Sq.mt.) Proposed FAR Area (Sq.mt.) Add Area In FAR (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
Lift Parking Resi. Stair
Basement Floor 311.88 3.23 253.20 0.00 15.45 15.45 15.45 00
Ground Floor 311.88 0.00 0.00 311.88 0.00 311.88 311.88 01
First Floor 311.88 3.23 0.00 308.65 0.00 308.65 308.65 00
Second Floor 311.88 3.23 0.00 308.65 0.00 308.65 308.65 00
Third Floor 311.88 3.23 0.00 308.65 0.00 308.65 308.65 00
Fourth Floor 311.88 3.23 0.00 308.65 0.00 308.65 308.65 00
Terrace Floor 0.00 0.00 0.00 0.00 0.00 0.00 0.00 00
Total : 1871.28 16.15 253.20 1546.48 15.45 1561.93 1561.93 01
Total Number of Same Buildings : 1
Total : 1871.28 16.15 253.20 1546.48 15.45 1561.93 1561.93 01
[-] Table 4c-2

  FAR Area
Building FAR Area:1561.93
Existing FAR Area :0.00
Perm.
1872.25
Prop.
1561.93
Status
OK




[-] Margin Checks (Table 5)
   
[-] Plot Margin (Table 5a)
Building / Wing Road Name Front Side Rear Side Side1 Side2 Status
Reqd. Prop. Reqd. Prop. Reqd. Prop. Reqd. Prop.
A-1 (BUILDING) 9.1 MTR WIDE MAIN ROAD 6.00 35.13 5.00 3.00 1.00 1.00 1.00 1.00 Failed


[-] BldgLine Margin (Table 5a-1)
Building/Wing Front Side Reqd. Prop. Main Road Name ResvRoad Name Reqd. Width Prop. Width Status
A-1 (BUILDING) BldgLine for 9.1 MTR WIDE MAIN ROAD 3.10 35.13 9.1 MTR WIDE MAIN ROAD 3.10 0.00 Failed





[-] Inner Building Details (Table 6)
   
   
[-] Lift Details (Table 6d)
Building Name Height Number Of Lift(s) Number Of Strature Lift(s) Capacity Of Lift(s) Passanger Status
Prop Reqd Prop Reqd Prop Reqd Prop
A (BUILDING) 15.00 1 1 - 0 6 6 OK

[-] Lift Check Table

[-] For Building :A (BUILDING)
Floor Name Lift Name Width Depth Status
Reqd Prop Reqd Prop
BASEMENT FLOOR PLAN Lift 1.70 1.70 1.90 1.90 OK
GROUND FLOOR PLAN Lift 1.70 1.70 1.90 1.90 OK
TYPICAL -1,2,3&4 FLOOR PLAN Lift 1.70 1.70 1.90 1.90 OK
TERRACE FLOOR PLAN Lift Machine Room 1.70 1.70 1.90 1.90 OK

   


[-] Parking Details (Table 7)
   

NO PARKING CHECK REQUIRED FOR SINGLE DWELLING UNIT. Bungalow/ Dwelling / Non Apartment, In Building: A (BUILDING)
   


[-] Exemption Details (Table 8)
   


Not Required to Check StairCase Number Rule.


[-] Staircase Checks (Table 8a-1)


[-] For Building :A (BUILDING)
Floor Name StairCase Name Flight Width Tread Width Riser Height Riser No. On Flight Cabin Ht. Status
Reqd Prop Reqd Prop Perm Prop Perm Prop Reqd Perm Prop
BASEMENT FLOOR PLAN STAIRCASE 0.900 1.400 0.250 0.250 0.200 0.000 - 0 - - 0.000 OK
GROUND FLOOR PLAN STAIRCASE 0.900 1.400 0.250 0.250 0.200 0.125 - 12 - - 0.000 OK
TYPICAL -1,2,3&4 FLOOR PLAN STAIRCASE 0.900 1.400 0.250 0.250 0.200 0.125 - 12 - - 0.000 OK
TERRACE FLOOR PLAN STAIRCASE - 1.400 - 0.250 - 0.000 - 0 - - 2.646 OK

   
   
   

[-] Ramp Checks (Table 8b-a)
Ramp Name Width Depth Slope Status
Reqd Prop Reqd Prop Reqd Perm Prop
7.00 mt. long 1.00 mt. High 3.60 mt. Wide Ramp 3.30 5.22 1.00 1.00 1.00 : 7.00 - 01 : 07 OK


[-] Ramp Checks (Table 8b)
Building Name Floor Name No. Status
Reqd Prop
A (BUILDING) BASEMENT FLOOR PLAN 1 1 OK

   
   
   
[-] Accessory Use Check (Table 8d)
Accessory Use Name Area Width Depth Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
Toilet - 5.00 1.80 - - 1.02 - - 1.76 - - 0.00 OK
SUMP TANK - - 1.80 - - 1.02 - - 1.76 - - 0.00 OK
RAIN WATER HARVESTING - - 1.80 - - 1.02 - - 1.76 - - 0.00 OK
SOLAR HEATING SYSTEM - - 13.26 - - 2.55 - - 5.21 - - 0.00 OK





[-] Accessory Use No. Checks
Building Name Accessory Use Name No Status
Reqd Perm Prop
A (BUILDING) Rain Water Harvesting 1 - 1 OK
Solar Water Heating System 1 - 1 OK
Entrance Gate 1 - 0 Failed
   
   


[-] Floor Details (Table 9)
   

[-] Building:A (BUILDING)


[-] Floor:BASEMENT FLOOR PLAN



No Room Found.


[-] Floor:GROUND FLOOR PLAN



All Dimensions and Area of all the Rooms on this Floor are as per the Rules.

[-] Floor:TYPICAL -1,2,3&4 FLOOR PLAN



All Dimensions and Area of all the Rooms on this Floor are as per the Rules.


   


[-] Summary (Table 10)
   
Name Perm./Reqd. Proposed Status
  Plot Area - 748.90 OK
  Plot Width - 12.18 OK
  Plot Depth - 61.46 OK
  Access Width 6.10 9.10 OK
  Plot Frontage - 10.66 OK
  Coverage Area 449.34 311.88 OK
  FAR Area
Bldg. FAR Area : 1561.93
Sanctioned FAR Area :0.00
1872.25 1561.93 OK





[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Width No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Depth No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Access Width The minimum width of abutting road for any Building more than 13.3 mt. ht. shall be 6.1 mt.{As per Rule no. 35.1 Note 4}
Plot Frontage No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
FAR Area (1) In New Area, for Residential Building on abutting roadwidth 9.10 (30 ft.) to 12.20 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15}
(2) For Medininagar Nagar Parishad, Max. 2.5 permissible FAR may be permitted for Residential Use {As per Annexure III}
Consumed FAR (1) In New Area, for Residential Building on abutting roadwidth 9.10 (30 ft.) to 12.20 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15}
(2) For Medininagar Nagar Parishad, Max. 2.5 permissible FAR may be permitted for Residential Use {As per Annexure III}
Common Plot Area In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
Common Plot (1) In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
(2) ;
Tree Number 4-8 Trees shall be required for the Plot area above 250.0 and upto 1000.0 sq.mt. (As per Rule No. 20.1.6)
Margin Rule For Non-highrise Residential Building 13.3-16.4 mt. Ht. having Plot Depth 45 mt. or above and Plot width 10-15 mt., Margin required in Front shall be 6.0 mt., Rear 5.0 mt. and 1.0 mt. shall be provided on both side. {As per Rule No. 36 (Table 8 & 9 and updated as per 4th Amendment dated 2nd Jan, 2019}
Building Line Check The min. width of Road for length of Road exceeding 1000 mt. shall be 15.30 mt. {As per Rule No. 34 Table No. 6}
ResvRoad Width Check The min. width of Road for length of Road exceeding 1000 mt. shall be 15.30 mt. {As per Rule No. 34 Table No. 6}
Basement Margin Rule Basements/cellars may be permitted to be constructed leaving the prescribed set back/open space applicable to the building {As per Rule No. 48}
Building Level
Building Height For new area, on Road width 9.10-12.20 mt., Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 23.10 mt. {As per Rule No. 39.1 Table 16}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(3) o Every basement shall be in every part at least 2.4 m. in height from the floor to the soffit of the roof slab or ceiling and mini. Of 2.1 mr. below the soffit of beams {As per Rule No. 48}
Parapet Height (1) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
(2) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
(3) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
Below GL Floor Height -,
Basement Floor No. Individual residential and small commercial buildings, plot size upto minimum 750 Sq. Meter may have one basement {As per Rule No. 48}
Floor Number For new area location,on Road width 9.1-12.2 mt. only G+6 floors shall be allowed {As per Rule No. 39.1 Table 16 and modified as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
Lift Count (1) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(2) For Residential Building height 12.0 mt. or above, upto G+4 floors or if the number of flats is upto 16, provision of lift will be compulsory. {As per Rule No. 49.1.2}
Lift (1) The area of lift well shall not be counted for F.A.R calculation)
(2) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(3) The area of lift well at one floor only (not the sum of total area of lift well at every floor) shall be counted for F.A.R calculation)
(4) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(5) -
StairCase (1) Width of Winding staircase shall be mini. 0.90 mt.,Maximum rise 0.20 mt. & Minimum tread 0.25 mt. & Cabin Height 2.1 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) No Rule Defined
(4) ; No Rule Defined
Ramp For parking spaces in basements and upper storey of parking floors,if car parking is less then 40, one ramp of minimum of 3.30m width if it is strait and 4.5m width if it is curved at any point and with minimum slope gradient of 1:7 for depth up to 1.8m and 1:10 for more than 1.8m depth shall be provided {As per Rule No. 41.8 and as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017} ;
Ramp No. For parking spaces in basements and upper storey of parking floors, if car parking is less then 40 one ramp of minimum of 3.30m width if it is straight and 4.50m width if it is curved shall be provided
Plot / Building Level
Accessory Use (1) Common toilet of maximum size of 5 sq.mt shall be taken Free from FAR
(2) No need to check distance from Building Toilet
(3) -
(4) No need to check distance from Building SUMP TANK
(5) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(6) No need to check distance from Building RAIN WATER HARVESTING
(7) -
(8) No need to check distance from Building SOLAR HEATING SYSTEM
Accessory Use Number (1) Provision of Rain Water Harvesting shall be mandatory for any use {Updated as per JBBL, Amendment VIII dated 16/03/2021} Rain Water Harvesting
(2) For Individual residential buildings having more than 150 sq m. plinth area, Provisions of Solar Water Heating System shall be done Solar Water Heating System
(3) In case of buildings with a height of 15.0 meters and above or ground coverage more than 500 sqm., the main entrance to the premise shall not be less than 5 (five) meters i n width in order to allow easy access to fire engine Entrance Gate
Building Level (Rooms)
Hall6.92x13.26 No Rule Defined
Hall8.91x13.26 No Rule Defined
Room3.00x7.41 No Rule Defined
Room5.28x5.72 No Rule Defined
Room5.28x7.41 No Rule Defined
Room5.60x5.28 No Rule Defined
Toilet3.20x2.03 Area for Toilet shall be Mini. 2.8 sq.mt. having side mini. 1.2 mt. {Rule No. 42.4.2}