Topic |
Rule |
Plot Level |
Plot Area |
No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
|
Plot Width |
No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
|
Plot Depth |
No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
|
Access Width |
The minimum width of abutting road for any Building shall be with respect to Length of Road {As per Rule No. 34 Table No.6}
|
Plot Frontage |
No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
|
FAR Area |
(1)
In New Area, FAR for plot which lies on road less than 6.10 m. the width shall be taken as incase of Old Area {As per Addendum from Govt. of Jharkhand 3141 dated 15/05/2017}
(2)
For Medininagar Nagar Parishad, Max. 2.5 permissible FAR may be permitted for Residential Use {As per Annexure III}
|
Consumed FAR |
(1)
In New Area, FAR for plot which lies on road less than 6.10 m. the width shall be taken as incase of Old Area {As per Addendum from Govt. of Jharkhand 3141 dated 15/05/2017}
(2)
For Medininagar Nagar Parishad, Max. 2.5 permissible FAR may be permitted for Residential Use {As per Annexure III}
|
Common Plot Area |
In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
|
Common Plot |
(1)
In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
(2)
;
|
Tree Number |
4-8 Trees shall be required for the Plot area above 250.0 and upto 1000.0 sq.mt. (As per Rule No. 20.1.6)
|
Margin Rule |
For Non-highrise Residential Building 10-13.3 mt. Ht. having Plot Depth 15-21 mt. and Plot width 15-21 mt., Margin required in Front shall be 3.0 mt., Rear 1.8 mt. and 1.5 mt. shall be provided on both side. {As per Rule No. 36 (Table 8 & 9)}
|
Building Level |
Building Height |
In New Area, for plot which lies on road less than 6.10 m. Perm. Building Ht. shall be taken as incase of Old Area {As per Addendum from Govt. of Jharkhand 3141 dated 15/05/2017}
|
Floor Height |
(1)
The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2)
The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
|
Parapet Height |
(1)
Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
(2)
Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
(3)
Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
|
Floor Number |
In New Area, for plot which lies on road less than 6.10 m. Perm. No of Floor shall be taken as incase of Old Area {As per Addendum from Govt. of Jharkhand 3141 dated 15/05/2017}
|
StairCase |
(1)
Width of Winding staircase shall be mini. 0.90 mt.,Maximum rise 0.20 mt. & Minimum tread 0.25 mt. & Cabin Height 2.1 mt. {As per Rule No. 83.18}
(2)
; No Rule Defined
(3)
No Rule Defined
(4)
; No Rule Defined
|
Plot / Building Level |
Accessory Use |
(1)
Common toilet of maximum size of 5 sq.mt shall be taken Free from FAR
(2)
No need to check distance from Building Toilet
(3)
-
(4)
No need to check distance from Building SUMP TANK
(5)
The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(6)
No need to check distance from Building RAIN WATER HARVESTING
(7)
-
(8)
No need to check distance from Building SOLAR HEATING SYSTEM
|
Accessory Use Number |
Provision of Rain Water Harvesting shall be mandatory for any use {Updated as per JBBL, Amendment VIII dated 16/03/2021} Rain Water Harvesting
|
Building Level (Rooms) |
Bed Room3.00x4.34
|
The area of habitable room shall not be less than 9.5 m2, where there is only one room with a minimum width of 2.4 m. Where there are two rooms, one of these shall not be less than 9.5 m2 and the other not less than 7.5 m2, with a minimum width of 2.1 mt. |
Bed Room4.26x3.00
|
The area of habitable room shall not be less than 9.5 m2, where there is only one room with a minimum width of 2.4 m. Where there are two rooms, one of these shall not be less than 9.5 m2 and the other not less than 7.5 m2, with a minimum width of 2.1 mt. |
Dining4.05x5.66
|
No Rule Defined |
Dining4.07x5.66
|
No Rule Defined |
Kitchen2.80x3.00
|
Area for Kitchen shall be Mini. 5.0 sq.mt. having side mini. 1.8 mt. {Rule No. 42.3.2} |
Kitchen2.81x3.00
|
Area for Kitchen shall be Mini. 5.0 sq.mt. having side mini. 1.8 mt. {Rule No. 42.3.2} |
Toilet3.00x1.20
|
Area for Toilet shall be Mini. 2.8 sq.mt. having side mini. 1.2 mt. {Rule No. 42.4.2} |