No Image Found   

Check List Report

Medininagar Municipal Corporation

Version Number: 1.0.73  
Version Date: 16/10/2020 
Report Generated On: 28-09-2024 
 

[-] Collapse All


General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictPALAMU
AuthorityMEDININAGAR MUNICIPAL CORPORATION
Inward_NoMNNP/BP/0228/W04/2024
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentNew
Location of Development AreaNew Area
City Area/TPScheme NoNA
VillageBaralota
Taluka27
Architect Details
Architect NamePANKAJ KUMAR SINGH
License No.MNNP/ENG/0006/2019
Architect AddressC/O PANKAJ KUMAR SINGH,HOUSE NO 28,NEAR BRIGHT LAND SCHOO BYE PASS ROAD ,ABADGANJ,DALTONGANJ,PALAMAU,JHARKHAND.
Architect EmailIDpankaj4870@gmail.com
Architect Mobile No8709050386
Plot Details
Plot Use Educational
Plot SubUse School
PlotNearbyReligiousStructure NA
Plot/SubPlot No1679
North -
South -
East -
West -
Owner's Details
NameSomeshwar Prasad
AddressBaralota
Email IDpankaj4870@gmail.com
Mobile No8709050386
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 10115.00
2 Plot area as per Document by Applicant 10115.00
3 Area as per Site Visit (Site Visit Report) 10115.00
4Area as per Drawing 2626.50

Area of Plot Considered : 2626.50

[-] Table 2b
Proposal Detail :
Unit
Development Detail :
PlotPLOT
Plot OccupancyEducational
Plot SubUse School
Building StructureNon-Highrise
Building TypeSingle Detached House
Gross Plot Area 2626.50
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 2626.50
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 2363.78
Deductions for Balance Plot Area (from Gross Plot Area)
- Common Plot 262.73
262.73
Balance Plot Area 2363.78

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 50.00 % ) 1313.25
Proposed Coverage Area ( 49.39 % ) 1297.22
Total Prop. Coverage Area ( 49.39 % ) 1297.22
Balance coverage area ( 0.61 % ) 16.03
FAR CHECK
Perm. FAR Area ( 2.250 ) 5909.63
Total Perm. FAR area 5909.63
Special FAR 2591.22
Proposed FAR Area 2591.22
Total Proposed FAR Area 2591.22
Consumed FAR (Factor) 0.99
Balance FAR Area 3318.41
BUA CHECK
Total Proposed BuiltUp Area 2594.44


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Exceeding 300 meter and upto 400 meter -
Existing Road Width 9.1 9.10
Proposed Road Width as per Master Plan 9.1 -
Road Widening Width 0 -
Plot size (as per measurement) 10115 2626.50
[-] Extra Land Area Checks
Name Area Status
Reqd Prop
Extra Land - 0.00 OK

     Extra Land Area Details
Name Description Unit Reqd Perm Proposed Status
Extra Land Area Details Extra Land Area - - 0.00 OK

     Plot Related Details
Name Description Unit Reqd Perm Proposed Status
PLOT Plot Area Sq.Mt. 2000.00 - 2626.50 OK
Plot Width Mt. - - 45.52 OK
Plot Depth Mt. - - 57.70 OK
Access Width Mt. 9.00 - 9.10 OK
Plot Frontage Mt. - - 45.52 OK
Coverage Area Sq.Mt. - 1313.25 1297.22 OK
FAR Area Sq.Mt. - 5909.63 2591.22 OK
Consumed FAR Sq.Mt. - 2.25 0.99 OK
Common Plot Checks Common Plot - Total Area Sq.Mt. 262.65 262.73 OK
Common Plot Tree Cover (Plantation) - Minimum Area Sq.Mt. - 262.73 OK
Tree Cover (Plantation) - Coverage Area Sq.Mt. - - OK
Tree Cover (Plantation) - Width Mt. - 6.45 OK
Tree Cover (Plantation) - Angle Degree - 89.07 OK
Tree Cover (Plantation) - Access Mt. - OK
Tree Tree - Nos Of Trees No. 8 8 OK
A-1 (BUILDING) Front Margin... 9.1 MTR WIDE ROAD Mt. 9.00 - 13.00 OK
Rear Margin Mt. 6.00 - 6.00 OK
Side1 Margin Mt. 6.00 - 6.00 OK
Side2 Margin Mt. 6.00 - 6.00 OK

     Building Related Details
Name Description Unit Reqd Perm Proposed Status
A (BUILDING) Height Mt. 23.10 6.80 OK
A (BUILDING) First Floor - Height Mt. 3.30 - 3.40 OK
First Floor - Clear Height Mt. 3.30 - 3.30 OK
First Floor - Beam Clear Height Mt. 2.40 - 2.95 OK
Ground Floor - Height Mt. 3.30 - 3.40 OK
Ground Floor - Clear Height Mt. 3.30 - 3.30 OK
Ground Floor - Beam Clear Height Mt. 2.40 - 2.95 OK
A (BUILDING) Terrace Floor - Height Mt. - - 1.00 OK
Terrace Floor - Clear Height Mt. - - 1.00 OK
Terrace Floor - Beam Clear Height Mt. - - 1.00 OK
A (BUILDING) No. of Floors No. G + 6 2 OK
No. of Tenements No. - 6 OK
A (BUILDING) Number Of Lift(s) No. - 1 OK
Number Of Strature Lift(s) No. - - OK
Capacity Of Lift(s) Passanger No. - 6 OK
A (BUILDING) GROUND FLOOR PLAN - Lift - Width Mt. 1.70 1.70 OK
GROUND FLOOR PLAN - Lift - Depth Mt. 1.90 1.90 OK
FIRST FLOOR PLAN - Lift - Width Mt. 1.70 1.70 OK
FIRST FLOOR PLAN - Lift - Depth Mt. 1.90 1.90 OK
TERRACE FLOOR PLAN - Lift Machine Room - Width Mt. 1.70 1.70 OK
TERRACE FLOOR PLAN - Lift Machine Room - Depth Mt. 1.90 1.90 OK
GROUND FLOOR PLAN STAIRCASE - Flight Width Mt. 0.750 1.800 OK
STAIRCASE - Tread Width Mt. 0.225 0.250 OK
STAIRCASE - Riser Height Mt. 0.200 0.113 OK
STAIRCASE - Riser No. On Flight No. - 15 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
FIRST FLOOR PLAN STAIRCASE - Flight Width Mt. 0.750 1.800 OK
STAIRCASE - Tread Width Mt. 0.225 0.250 OK
STAIRCASE - Riser Height Mt. 0.200 0.113 OK
STAIRCASE - Riser No. On Flight No. - 15 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
TERRACE FLOOR PLAN STAIRCASE - Flight Width Mt. - 1.800 OK
STAIRCASE - Tread Width Mt. - 0.250 OK
STAIRCASE - Riser Height Mt. - - OK
STAIRCASE - Riser No. On Flight No. - - OK
STAIRCASE - Cabin Ht. Mt. 2.100 - 2.550 OK
Toilet Area Sq.Mt. - 5.00 4.67 OK
Width Mt. - - 2.14 OK
Depth Mt. - - 2.18 OK
Height Mt. - - - OK
SUMP TANK Area Sq.Mt. - - 8.29 OK
Width Mt. - - 2.19 OK
Depth Mt. - - 3.79 OK
Height Mt. - - - OK
RAIN WATER HARVESTING Area Sq.Mt. - - 7.27 OK
Width Mt. - - 2.05 OK
Depth Mt. - - 3.55 OK
Height Mt. - - - OK
ENT.GATE Area Sq.Mt. - - 0.87 OK
Width Mt. - - 0.32 OK
Depth Mt. - - 2.71 OK
Height Mt. - - - OK
SOLAR HEATING SYSTEM Area Sq.Mt. - - 25.11 OK
Width Mt. - - 2.93 OK
Depth Mt. - - 8.59 OK
Height Mt. - - - OK
A (BUILDING) Rain Water Harvesting - No No. 1 - 1 OK
Entrance Gate - No No. 1 - 1 OK
   
    All Rooms are as per Rule in Room Checking




[-] Rules
Topic Rule
Plot Level
Plot Area The minimum size of plot for Primary/Upper Primary school category shall be 2000.0 sq.mt. {As per Rule No. 35.1, Table 7}
Plot Width The minimum size of plot for Primary/Upper Primary school category shall be 2000.0 sq.mt. {As per Rule No. 35.1, Table 7}
Plot Depth The minimum size of plot for Primary/Upper Primary school category shall be 2000.0 sq.mt. {As per Rule No. 35.1, Table 7}
Access Width The minimum width of abutting road for Primary/Upper Primary school category shall be 9.0 mt. {As per Rule No. 35.1, Table 7}
Plot Frontage The minimum size of plot for Primary/Upper Primary school category shall be 2000.0 sq.mt. {As per Rule No. 35.1, Table 7}
FAR Area (1) For Educational, Institutional and Assembly building above 1000 sq.mt. Plot area, the Floor Area Ratio-FAR shall be 2.25 {As per Rule No. 39.3}
(2) No Rule Define.
Consumed FAR (1) For Educational, Institutional and Assembly building above 1000 sq.mt. Plot area, the Floor Area Ratio-FAR shall be 2.25 {As per Rule No. 39.3}
(2) No Rule Define.
Common Plot Area In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
Common Plot (1) In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
(2) ;
Tree Number Mini. 8 Trees shall be required for the Plot area above 1000.0 sq.mt. (As per Rule No. 20.1.6)
Margin Rule For Educational Building, Margin required in Front shall be 9.0 mt., Rear 6.0 mt. and 6.0 mt. shall be provided on both side. {As per Rule No. 38.2.1}
Building Level
Building Height For new area, on Road width 9.10-12.20 mt., Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 23.10 mt. {As per Rule No. 39.1 Table 16}
Floor Height (1) For Educational Bulding, The height of all rooms shall not be less than 3.3 m measured from the surface of the floor to the lowest point of the ceiling
(2) For Educational Bulding, The height of all rooms shall not be less than 3.3 m measured from the surface of the floor to the lowest point of the ceiling
Parapet Height (1) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
(2) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
(3) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
Floor Number For new area location,on Road width 9.1-12.2 mt. only G+6 floors shall be allowed {As per Rule No. 39.1 Table 16 and modified as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
Lift Count (1) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(2) For Non-Residential Building, No Lift is reqd for Building upto G+2 floor {As per Rule No. 49.2.2}
Lift (1) The area of lift well at one floor only (not the sum of total area of lift well at every floor) shall be counted for F.A.R calculation)
(2) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(3) The area of lift well shall not be counted for F.A.R calculation)
(4) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(5) -
StairCase (1) Width of Winding staircase shall be mini. 0.75 mt.,Maximum rise 0.20 mt. & Minimum tread 0.225 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) Width of Winding staircase shall be mini. 0.75 mt.,Maximum rise 0.20 mt. & Minimum tread 0.225 mt. & Cabin height 2.1 mt {As per Rule No. 83.18}
(4) ; No Rule Defined
Plot / Building Level
Accessory Use (1) Common toilet of maximum size of 5 sq.mt shall be taken Free from FAR
(2) No need to check distance from Building Toilet
(3) -
(4) No need to check distance from Building SUMP TANK
(5) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(6) No need to check distance from Building RAIN WATER HARVESTING
(7) No need to check distance from Building ENT.GATE
(8) -
(9) No need to check distance from Building SOLAR HEATING SYSTEM
Accessory Use Number (1) Provision of Rain Water Harvesting shall be mandatory for any use {Updated as per JBBL, Amendment VIII dated 16/03/2021} Rain Water Harvesting
(2) In case of buildings with a height of 15.0 meters and above or ground coverage more than 500 sqm., the main entrance to the premise shall not be less than 5 (five) meters i n width in order to allow easy access to fire engine Entrance Gate
Building Level (Rooms)