-
No Image Found   

Detail Scrutiny Report

Madhupur Nagar Parishad

Version Number: 1.0.60  
Version Date: 16/10/2020 
Report Generated On: 14-09-2021 
 
[-] Collapse All


General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictDEOGHAR
AuthorityMADHUPUR NAGAR PARISHAD
Inward_NoMNP/BP/0026/W17/2021
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentNew
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillageBara Shekhpura
Taluka18
Architect Details
Architect NameRAJKISHOR KUMAR
License No.MNP/ENG/0003/2018
Architect AddressIN FRONT OF SBI TRAINING CENTRE
Architect EmailIDrkrajkishor7@gmail.com
Architect Mobile No9801383705
Plot Details
Plot Use Residential
Plot SubUse Bungalow/ Dwelling / Non Apartment
PlotNearbyReligiousStructure NA
Plot/SubPlot NoSUB PLOT NO- 20 AND 21
NorthPlot No. - SUB PLOT NO- 19
SouthRoad Width - 3.0
EastPlot No. - 3' WIDE PROPOSED LANE
WestRoad Width - 18.2
Owner's Details
NameSMT. KAMLA TIWARI
AddressMADHUPUR
Email IDrkrajkishor7@gmail.com
Mobile No8082829034
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 305.57
2 Plot area as per Document by Applicant 305.57
3 Physical area measured at site 295.88
4 Area as per Site Visit (Site Visit Report) 295.88
5Area as per Drawing 295.88

Area of Plot Considered : 295.88

[-] Table 2b
Proposal Detail :
UnitMeters
Development Detail :
PlotPLOT
Plot OccupancyResidential
Plot SubUse Bungalow/ Dwelling / Non Apartment
Building StructureNon-Highrise
Building TypeSingle Detached House
Gross Plot Area 295.88
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 295.88
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 247.45
Deductions for Balance Plot Area (from Gross Plot Area)
- Common Plot 48.43
48.43
Balance Plot Area 247.45

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 60.00 % ) 177.53
Proposed Coverage Area ( 58.56 % ) 173.27
Total Prop. Coverage Area ( 58.56 % ) 173.27
Balance coverage area ( 1.44 % ) 4.26
FAR CHECK
Perm. FAR Area ( 2.00 ) 591.76
Total Perm. FAR area 591.76
Residential FAR 167.97
Proposed FAR Area 167.97
Total Proposed FAR Area 167.97
Consumed FAR (Factor) 0.57
Balance FAR Area 423.79
BUA CHECK
Total Proposed BuiltUp Area 173.27


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Exceeding 1000 meter -
Existing Road Width 18.2 18.20
Proposed Road Width as per Master Plan 18.2 -
Road Widening Width 0 -
Plot size (as per measurement) 295.88 295.88
[-] Extra Land Area Checks
Name Area Status
Reqd Prop
Extra Land - 0.00 OK


[-] Plot Level Checking (Table 3)
   
[-] Common Plot Checks (Table 3b)
Name Total Area Status
Reqd Prop
Common Plot 14.79 48.43 OK


[-] Common Plot Checks (Table 3b)
Name Minimum Area Coverage Area Width Angle Access Status
Reqd Prop Perm Prop Reqd Prop Reqd Prop
Tree Cover (Plantation) - 14.90 0.00 0.00 - 1.07 - 90.00 3.00 mt. Wide MainRoad Access Road OK
Tree Cover (Plantation) - 16.34 0.00 0.00 - 1.04 - 90.00 3.00 mt. Wide MainRoad Access Road OK
Tree Cover (Plantation) - 17.19 0.00 0.00 - 1.04 - 90.00 No Access Provided OK


   
   
[-] Tree Details (Table 3g)
Name Nos Of Trees Status
Reqd Prop
Tree 4 3 Failed
   
   
   
   
   


[-] Building Details (Table 4)
   
[-] Building USE/SUBUSE Details Building USE/SUBUSE Details
Building Name Building Use Building SubUse Building Structure
A (FOR KAMALA TIWARI) Residential Bungalow/ Dwelling / Non Apartment Non-Highrise
   
   
   
[-] Height Details (4a)



[-] Total Height (Table 4a-1)
Building Height Height (From GL) Height (From Street LVL) Status
Perm Prop
A (FOR KAMALA TIWARI) 30.00 3.30 3.30 3.42 OK


   
   
[-] Floor Height Check (Table 4a-2)
Building Name Floor Name Height Clear Height Beam Clear Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
A (FOR KAMALA TIWARI) Ground Floor 2.75 - 3.30 2.75 - 3.18 2.40 - 2.93 OK
Plinth 0.45 - 0.60 - - 0.60 - - 0.60 OK


[-] Parapet Height Check (Table 4a-2.1)
Building Name Floor Name Height Status
Reqd Perm Prop
A (FOR KAMALA TIWARI) Terrace Floor - - 1.00 OK
   
   
   
[-] Floor Number Check (Table 4a-4)
Building Name No. of Floors No. of Tenements Status
Perm Prop Perm Prop
A (FOR KAMALA TIWARI) - 1 - 1 OK

 
   
    [-] Coverage Check (Table 4b)
Permissible Proposed Status
177.53 173.27 OK
60% 58.56%

[-] Individual Coverage Check
Coverage Area Perm. Prop.
  A-1 (FOR KAMALA TIWARI) - 173.27
  Total Prop. Coverage Area - 173.27
  Total Coverage Area 177.53 173.27

[-] FAR & Tenement Details (Table 4c-1)
Building No. of Same Bldg Total Built Up Area (Sq.mt.) Deductions (Area in Sq.mt.) Proposed FAR Area (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
Accessory Use Resi.
A (FOR KAMALA TIWARI) 1 173.27 5.30 167.97 167.97 167.97 01
Grand Total : 1 173.27 5.30 167.97 167.97 167.97 01


[-] Buildingwise Floor FAR Details
Floor Name Building Name Total
A (FOR KAMALA TIWARI)
Proposed Built Up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Total Proposed Built Up Area (Sq.mt.) Total FAR Area (Sq.mt.)
Ground Floor 173.27 167.97 173.27 167.97
Terrace Floor 0.00 0.00 0.00 0.00
Total : 173.27 167.97 173.27 167.97


[-] UnitBUA Table for Building :A (FOR KAMALA TIWARI)
UnitBUA CALCULATION
FLOOR Name UnitBUA Type UnitBUA Area Carpet Area No. of Rooms No. of Tenement
GROUND FLOOR PLAN SPLIT F-1&2 FLAT 146.92 146.53 6 1
SPLIT F-1&2 FLAT 0.00 0.00 8
Total: - - 146.92 146.53 14 1


[-] Building :A (FOR KAMALA TIWARI)
Floor Name Total Built Up Area (Sq.mt.) Deductions (Area in Sq.mt.) Proposed FAR Area (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
Accessory Use Resi.
Ground Floor 173.27 5.30 167.97 167.97 167.97 01
Terrace Floor 0.00 0.00 0.00 0.00 0.00 00
Total : 173.27 5.30 167.97 167.97 167.97 01
Total Number of Same Buildings : 1
Total : 173.27 5.30 167.97 167.97 167.97 01
[-] Table 4c-2

  FAR Area
Building FAR Area:167.97
Existing FAR Area :0.00
Perm.
591.76
Prop.
167.97
Status
OK




[-] Margin Checks (Table 5)
   
[-] Plot Margin (Table 5a)
Building / Wing Road Name Front Side Rear Side Side1 Side2 Status
Reqd. Prop. Reqd. Prop. Reqd. Prop. Reqd. Prop.
A-1 (FOR KAMALA TIWARI) 18.20 mt. Wide MainRoad 2.50 3.33 1.50 1.50 0.90 1.05 0.90 1.05 OK






[-] Inner Building Details (Table 6)
   

No OTS/Duct/VShaft/Balcony/Passage/Lift/Tenements Found.
   


[-] Parking Details (Table 7)
   

NO PARKING CHECK REQUIRED FOR SINGLE DWELLING UNIT. Bungalow/ Dwelling / Non Apartment, In Building: A (FOR KAMALA TIWARI)
   


[-] Exemption Details (Table 8)
   


Not Required to Check StairCase Number Rule.


[-] Staircase Checks (Table 8a-1)


[-] For Building :A (FOR KAMALA TIWARI)
Floor Name StairCase Name Flight Width Tread Width Riser Height Riser No. On Flight Cabin Ht. Status
Reqd Prop Reqd Prop Perm Prop Perm Prop Reqd Perm Prop
GROUND FLOOR PLAN STAIRCASE 0.750 0.988 0.225 0.250 0.200 0.150 - 11 - - 0.000 OK
TERRACE FLOOR PLAN STAIRCASE - 0.988 - 0.250 - 0.000 - 0 2.100 - 2.525 OK

   
   
[-] Arch Projection Checks (Table 8c - a)

[-] For Building :A (FOR KAMALA TIWARI)
Floor Name Arch Proj Name Width Depth Area Status
Perm Prop Perm Prop Perm Prop
GROUND FLOOR PLAN CHHAJJA 0.75 0.60 - 12.90 - 7.74 OK
   
   
   
[-] Accessory Use Check (Table 8d)
Accessory Use Name Area Width Depth Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
SEPTIC TANK - - 1.48 - - 0.97 - - 1.53 - - 0.00 OK
RAIN WATER HARVESTING - - 1.48 - - 0.97 - - 1.53 - - 0.00 OK
Entrance Lobby - 12.00 5.30 - - 2.10 - - 2.53 - - 0.00 OK
SOLAR HEATING SYSTEM - - 1.48 - - 0.97 - - 1.53 - - 0.00 OK





[-] Accessory Use No. Checks
Building Name Accessory Use Name No Status
Reqd Perm Prop
A (FOR KAMALA TIWARI) Rain Water Harvesting 1 - 1 OK
Solar Water Heating System 1 - 1 OK
   
   


[-] Floor Details (Table 9)
   

[-] Building:A (FOR KAMALA TIWARI)


[-] Floor:GROUND FLOOR PLAN



All Dimensions and Area of all the Rooms on this Floor are as per the Rules.


   


[-] Summary (Table 10)
   
Name Perm./Reqd. Proposed Status
  Plot Area - 295.88 OK
  Plot Width - 15.00 OK
  Plot Depth - 19.73 OK
  Access Width - 18.20 OK
  Plot Frontage - 15.00 OK
  Coverage Area 177.53 173.27 OK
  FAR Area
Bldg. FAR Area : 167.97
Sanctioned FAR Area :0.00
591.76 167.97 OK





[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Width No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Depth No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Access Width The minimum width of abutting road for any Building shall be with respect to Length of Road {As per Rule No. 34 Table No.6}
Plot Frontage No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
FAR Area (1) In Old Area, for Residential Building on abutting roadwidth 12.20 (40 ft.) to 18.30 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15}
(2) For Madhupur Nagar Parishad, Max. 2.0 permissible FAR may be permitted for Residential Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Residential Building on abutting roadwidth 12.20 (40 ft.) to 18.30 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15}
(2) For Madhupur Nagar Parishad, Max. 2.0 permissible FAR may be permitted for Residential Use {As per Annexure III}
Common Plot Area In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
Common Plot (1) ; In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
(2) ;
(3) In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
(4) ;
Tree Number 4-8 Trees shall be required for the Plot area above 250.0 and upto 1000.0 sq.mt. (As per Rule No. 20.1.6)
Margin Rule For Non-highrise Residential Building upto 10.0 mt. Ht. having Plot Depth 15-21 mt. and Plot width 10-15 mt., Margin required in Front shall be 2.5 mt., Rear 1.5 mt. and 0.9 mt. shall be provided on both side. {As per Rule No. 36 (Table 8 & 9)}
Building Level
Building Height For old area, on Road width 12.20-18.30 mt., Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 30.0 mt. {As per Rule No. 39.1 Table 15}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(3) The plinth or any part of a building shall be so located with respect to the surrounding ground level that adequate drainage of the site is assured. The height of the plinth (except in case of stilted parking) shall be not less than 0.45 mt. from the surrounding ground level {As per Rule No. 42.10}
Parapet Height Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
Floor Number For old area location,on Road width 12.20-18.30 mt., Maximum Height 30 meter shall be allowed. {As per Rule No. 39.1 Table 15}
StairCase (1) Width of Winding staircase shall be mini. 0.75 mt.,Maximum rise 0.20 mt. & Minimum tread 0.225 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) Width of Winding staircase shall be mini. 0.75 mt.,Maximum rise 0.20 mt. & Minimum tread 0.225 mt. & Cabin height 2.1 mt {As per Rule No. 83.18}
(4) ; No Rule Defined
Arch Projection (1) No need to check
(2) Chhajja,Cornice or Weather shed of upto 0.75m width shall be permitted. {As per Rule No. 46.1}
Plot / Building Level
Accessory Use (1) -
(2) No need to check distance from Building SEPTIC TANK
(3) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(4) No need to check distance from Building RAIN WATER HARVESTING
(5) Entrance Lobby of maximum size of 12 sq.m. shall be taken Free from FAR
(6) No need to check distance from Building Entrance Lobby
(7) -
(8) No need to check distance from Building SOLAR HEATING SYSTEM
Accessory Use Number (1) Provision of Rain Water Harvesting shall be mandatory for any use {Updated as per JBBL, Amendment VIII dated 16/03/2021} Rain Water Harvesting
(2) For Individual residential buildings having more than 150 sq m. plinth area, Provisions of Solar Water Heating System shall be done Solar Water Heating System
Building Level (Rooms)