General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictDEOGHAR
AuthorityMADHUPUR NAGAR PARISHAD
Inward_NoMNP/BP/0035/W15/2021
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentNew
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillagePasia
Taluka18
Architect Details
Architect NameRAJKISHOR KUMAR
License No.MNP/ENG/0003/2018
Architect AddressIN FRONT OF SBI TRAINING CENTRE
Architect EmailIDrkrajkishor7@gmail.com
Architect Mobile No9801383705
Plot Details
Plot Use Residential
Plot SubUse Bungalow/ Dwelling / Non Apartment
PlotNearbyReligiousStructure NA
Plot/SubPlot NoKA
NorthPlot No. - LAND OF DEO NARAYAN BHAYA
SouthRoad Width - 24.30
EastPlot No. - LAND OF PREMESHWAR MANDAL
WestPlot No. - LAND OF MAHESH GUPTA
Owner's Details
NameSMT. KIRAN DEVI AND MINA DEVI
AddressMADHUPUR
Email IDAJITKUMAR335577@GMAIL.COM
Mobile No8210987385
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 242.56
2 Plot area as per Document by Applicant 242.56
3 Physical area measured at site 235.48
4 Area as per Site Visit (Site Visit Report) 235.48
5Area as per Drawing 234.90

Area of Plot Considered : 234.90

[-] Table 2b
Proposal Detail :
UnitMeters
Development Detail :
PlotPLOT
Plot OccupancyResidential
Plot SubUse Bungalow/ Dwelling / Non Apartment
Building StructureNon-Highrise
Building TypeSingle Detached House
Gross Plot Area 234.90
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 234.90
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 197.72
Deductions for Balance Plot Area (from Gross Plot Area)
- Common Plot 37.18
37.18
Balance Plot Area 197.72

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 70.00 % ) 164.43
Proposed Coverage Area ( 68.07 % ) 159.90
Total Prop. Coverage Area ( 68.07 % ) 159.90
Balance coverage area ( 1.93 % ) 4.53
FAR CHECK
Perm. FAR Area ( 2.00 ) 469.80
Total Perm. FAR area 469.80
Residential FAR 316.02
Proposed FAR Area 316.02
Total Proposed FAR Area 316.02
Consumed FAR (Factor) 1.35
Balance FAR Area 153.78
BUA CHECK
Total Proposed BuiltUp Area 319.80


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Exceeding 300 meter and upto 400 meter -
Existing Road Width 24.3 24.30
Proposed Road Width as per Master Plan 24.3 -
Road Widening Width 0.75 -
Plot size (as per measurement) 235.48 234.90
[-] Extra Land Area Checks
Name Area Status
Reqd Prop
Extra Land - 0.00 OK

     Extra Land Area Details
Name Description Unit Reqd Perm Proposed Status
Extra Land Area Details Extra Land Area - - 0.00 OK

     Plot Related Details
Name Description Unit Reqd Perm Proposed Status
PLOT Plot Area Sq.Mt. - - 234.90 OK
Plot Width Mt. - - 8.70 OK
Plot Depth Mt. - - 27.00 OK
Access Width Mt. - - 24.30 OK
Plot Frontage Mt. - - 8.70 OK
Coverage Area Sq.Mt. - 164.43 159.90 OK
FAR Area Sq.Mt. - 469.80 316.02 OK
Consumed FAR Sq.Mt. - 2.00 1.35 OK
Common Plot Checks Common Plot - Total Area Sq.Mt. 11.74 37.18 OK
Common Plot Tree Cover (Plantation) - Minimum Area Sq.Mt. - 17.99 OK
Tree Cover (Plantation) - Coverage Area Sq.Mt. - - OK
Tree Cover (Plantation) - Width Mt. - 0.86 OK
Tree Cover (Plantation) - Angle Degree - 90.00 OK
Tree Cover (Plantation) - Access Mt. - OK
Tree Cover (Plantation) - Minimum Area Sq.Mt. - 19.19 OK
Tree Cover (Plantation) - Coverage Area Sq.Mt. - - OK
Tree Cover (Plantation) - Width Mt. - 2.47 OK
Tree Cover (Plantation) - Angle Degree - 90.00 OK
Tree Cover (Plantation) - Access Mt. - OK
Tree Tree - Nos Of Trees No. 2 4 OK
A-1 (FOR SMT KIRAN DEVI) Front Margin... 24.30 mt. Wide MainRoad Mt. 3.00 - 4.00 OK
Rear Margin Mt. 1.80 - 2.50 OK
Side1 Margin Mt. 0.90 - 0.90 OK
Side2 Margin Mt. - - 0.00 OK

     Building Related Details
Name Description Unit Reqd Perm Proposed Status
A (FOR SMT KIRAN DEVI) Height Mt. 40.45 6.30 OK
A (FOR SMT KIRAN DEVI) First Floor - Height Mt. 2.75 - 3.15 OK
First Floor - Clear Height Mt. 2.75 - 3.03 OK
First Floor - Beam Clear Height Mt. 2.40 - 2.78 OK
Ground Floor - Height Mt. 2.75 - 3.15 OK
Ground Floor - Clear Height Mt. 2.75 - 3.03 OK
Ground Floor - Beam Clear Height Mt. 2.40 - 2.78 OK
Plinth - Height Mt. 0.45 - 0.60 OK
Plinth - Clear Height Mt. - - 0.60 OK
Plinth - Beam Clear Height Mt. - - 0.60 OK
A (FOR SMT KIRAN DEVI) Terrace Floor - Height Mt. - - 1.00 OK
A (FOR SMT KIRAN DEVI) No. of Floors No. - 2 OK
No. of Tenements No. - 1 OK
A (FOR SMT KIRAN DEVI) Number Of Lift(s) No. - 1 OK
Number Of Strature Lift(s) No. - - OK
Capacity Of Lift(s) Passanger No. - 6 OK
A (FOR SMT KIRAN DEVI) FIRST FLOOR PLAN - Lift - Width Mt. 1.70 1.80 OK
FIRST FLOOR PLAN - Lift - Depth Mt. 1.90 2.10 OK
TERRACE FLOOR PLAN - Lift Machine Room - Width Mt. 1.70 2.30 OK
TERRACE FLOOR PLAN - Lift Machine Room - Depth Mt. 1.90 2.88 OK
GROUND FLOOR PLAN - Lift - Width Mt. 1.70 1.80 OK
GROUND FLOOR PLAN - Lift - Depth Mt. 1.90 2.10 OK
FIRST FLOOR PLAN STAIRCASE - Flight Width Mt. 0.750 0.988 OK
STAIRCASE - Tread Width Mt. 0.225 0.250 OK
STAIRCASE - Riser Height Mt. 0.200 0.143 OK
STAIRCASE - Riser No. On Flight No. - 11 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
TERRACE FLOOR PLAN STAIRCASE - Flight Width Mt. - 0.988 OK
STAIRCASE - Tread Width Mt. - 0.250 OK
STAIRCASE - Riser Height Mt. - - OK
STAIRCASE - Riser No. On Flight No. - - OK
STAIRCASE - Cabin Ht. Mt. 2.100 - 2.525 OK
GROUND FLOOR PLAN STAIRCASE - Flight Width Mt. 0.750 0.988 OK
STAIRCASE - Tread Width Mt. 0.225 0.250 OK
STAIRCASE - Riser Height Mt. 0.200 0.143 OK
STAIRCASE - Riser No. On Flight No. - 11 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
SEPTIC TANK Area Sq.Mt. - - 1.72 OK
Width Mt. - - 0.88 OK
Depth Mt. - - 1.95 OK
Height Mt. - - - OK
RAIN WATER HARVESTING Area Sq.Mt. - - 1.72 OK
Width Mt. - - 0.88 OK
Depth Mt. - - 1.95 OK
Height Mt. - - - OK
SOLAR HEATING SYSTEM Area Sq.Mt. - - 1.67 OK
Width Mt. - - 0.77 OK
Depth Mt. - - 2.15 OK
Height Mt. - - - OK
A (FOR SMT KIRAN DEVI) Rain Water Harvesting - No No. 1 - 1 OK
Solar Water Heating System - No No. 1 - 1 OK
   
    All Rooms are as per Rule in Room Checking




[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Width No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Depth No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Access Width The minimum width of abutting road for any Building shall be with respect to Length of Road {As per Rule No. 34 Table No.6}
Plot Frontage No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
FAR Area (1) In Old Area, for Residential Building on abutting roadwidth 18.30 (60 ft) and above, the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15}
(2) For Madhupur Nagar Parishad, Max. 2.0 permissible FAR may be permitted for Residential Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Residential Building on abutting roadwidth 18.30 (60 ft) and above, the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15}
(2) For Madhupur Nagar Parishad, Max. 2.0 permissible FAR may be permitted for Residential Use {As per Annexure III}
Common Plot Area In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
Common Plot (1) ; In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
(2) ;
(3) In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
(4) ;
Tree Number 2-4 Trees shall be required for the Plot area upto 250.0 sq.mt. (As per Rule No. 20.1.6)
Margin Rule For Non-highrise Residential Building upto 10.0 mt. Ht. having Plot Depth 21-27 mt. and Plot width 21-27 mt., Margin required in Front shall be 3.0 mt., Rear 1.8 mt. and Atleast 0.9 mt. shall be provided at one side. {As per Rule No. 36 (Table 8 & 9)}
Building Level
Building Height For old area, on Road width above 18.30 mt., No restriction on height and number of floors however it may be regulated by the master plan/development plan/zonal plan {As per Rule No. 39.1 Table 15}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(3) The plinth or any part of a building shall be so located with respect to the surrounding ground level that adequate drainage of the site is assured. The height of the plinth (except in case of stilted parking) shall be not less than 0.45 mt. from the surrounding ground level {As per Rule No. 42.10}
Parapet Height Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
Floor Number For old area location,on Road width 18.30 mt. and above, No restriction on height and number of floors however it may be regulated by the master plan/development plan/zonal plan {As per Rule No. 39.1 Table 15}
Lift Count (1) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(2) For Residential Building height upto 15.0 mt or upto G+4 floors, No Lift is reqd. {As per Amended 06-06-2019 Rule No. 49.1.1}
Lift (1) The area of lift well shall not be counted for F.A.R calculation)
(2) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(3) -
(4) The area of lift well at one floor only (not the sum of total area of lift well at every floor) shall be counted for F.A.R calculation)
(5) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
StairCase (1) Width of Winding staircase shall be mini. 0.75 mt.,Maximum rise 0.20 mt. & Minimum tread 0.225 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) Width of Winding staircase shall be mini. 0.75 mt.,Maximum rise 0.20 mt. & Minimum tread 0.225 mt. & Cabin height 2.1 mt {As per Rule No. 83.18}
(4) ; No Rule Defined
Plot / Building Level
Accessory Use (1) -
(2) No need to check distance from Building SEPTIC TANK
(3) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(4) No need to check distance from Building RAIN WATER HARVESTING
(5) -
(6) No need to check distance from Building SOLAR HEATING SYSTEM
Accessory Use Number (1) Provision of Rain Water Harvesting shall be mandatory for any use {Updated as per JBBL, Amendment VIII dated 16/03/2021} Rain Water Harvesting
(2) For Individual residential buildings having more than 150 sq m. plinth area, Provisions of Solar Water Heating System shall be done Solar Water Heating System
Building Level (Rooms)