No Image Found   

Check List Report

Madhupur Nagar Parishad

Version Number: 1.0.62  
Version Date: 16/10/2020 
Report Generated On: 21-06-2022 
 

[-] Collapse All


General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictDEOGHAR
AuthorityMADHUPUR NAGAR PARISHAD
Inward_NoMNP/BP/0035/W01/2022
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentNew
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillageLakhna
Taluka18
Architect Details
Architect NameRAJKISHOR KUMAR
License No.MNP/ENG/0003/2018
Architect AddressIN FRONT OF SBI TRAINING CENTRE
Architect EmailIDrkrajkishor7@gmail.com
Architect Mobile No9801383705
Plot Details
Plot Use Mixed
Plot SubUse Resi+Comm
PlotNearbyReligiousStructure NA
Plot/SubPlot No144
NorthPlot No. - VENDORS LAND
SouthRoad Width - 18.2
EastPlot No. - LAND OF MD. ASRAF
WestPlot No. - VENDORS LAND
Owner's Details
NameSHAYESTA NIGAR
AddressMADHUPUR
Email IDAJITKUMAR335577@GMAIL.COM
Mobile No7368020859
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 261.71
2 Plot area as per Document by Applicant 261.71
3 Physical area measured at site 255.92
4 Area as per Site Visit (Site Visit Report) 255.92
5Area as per Drawing 255.92

Area of Plot Considered : 255.92

[-] Table 2b
Proposal Detail :
Unit
Development Detail :
PlotPLOT
Plot OccupancyMixed
Plot SubUse -
Higher Plot Use
Higher Plot Sub UseResi+Comm
Lower Plot Use
Lower Plot Sub Use
Building StructureNon-Highrise
Building TypeSingle Detached House
Gross Plot Area 255.92
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 255.92
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 184.07
Deductions for Balance Plot Area (from Gross Plot Area)
- Common Plot 71.84
71.84
Balance Plot Area 184.07

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 60.00 % ) 153.55
Proposed Coverage Area ( 34.98 % ) 89.51
Total Prop. Coverage Area ( 34.98 % ) 89.51
Balance coverage area ( 25.02 % ) 64.04
FAR CHECK
Perm. FAR Area ( 2.00 ) 511.82
Total Perm. FAR area 511.82
Residential FAR 248.27
Commercial FAR 86.18
Proposed FAR Area 334.44
Total Proposed FAR Area 334.44
Consumed FAR (Factor) 1.31
Balance FAR Area 177.38
BUA CHECK
Total Proposed BuiltUp Area 358.03


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Exceeding 50 meter and upto 100 meter -
Existing Road Width 18.2 18.20
Proposed Road Width as per Master Plan 18.2 -
Road Widening Width 0 -
Plot size (as per measurement) 255.92 255.92
[-] Extra Land Area Checks
Name Area Status
Reqd Prop
Extra Land - 0.00 OK

     Extra Land Area Details
Name Description Unit Reqd Perm Proposed Status
Extra Land Area Details Extra Land Area - - 0.00 OK

     Plot Related Details
Name Description Unit Reqd Perm Proposed Status
PLOT Plot Area Sq.Mt. - - 255.92 OK
Plot Width Mt. - - 12.10 OK
Plot Depth Mt. - - 21.15 OK
Access Width Mt. - - 18.20 OK
Plot Frontage Mt. - - 12.10 OK
Coverage Area Sq.Mt. - 153.55 89.51 OK
FAR Area Sq.Mt. - 511.82 334.44 OK
Consumed FAR Sq.Mt. - 2.00 1.31 OK
Common Plot Checks Common Plot - Total Area Sq.Mt. 25.59 71.84 OK
Common Plot Tree Cover (Plantation) - Minimum Area Sq.Mt. - 10.79 OK
Tree Cover (Plantation) - Coverage Area Sq.Mt. - - OK
Tree Cover (Plantation) - Width Mt. - 1.96 OK
Tree Cover (Plantation) - Angle Degree - 90.00 OK
Tree Cover (Plantation) - Access Mt. - OK
Tree Cover (Plantation) - Minimum Area Sq.Mt. - 13.42 OK
Tree Cover (Plantation) - Coverage Area Sq.Mt. - - OK
Tree Cover (Plantation) - Width Mt. - 1.91 OK
Tree Cover (Plantation) - Angle Degree - 90.00 OK
Tree Cover (Plantation) - Access Mt. - OK
Tree Cover (Plantation) - Minimum Area Sq.Mt. - 47.63 OK
Tree Cover (Plantation) - Coverage Area Sq.Mt. - - OK
Tree Cover (Plantation) - Width Mt. - 3.95 OK
Tree Cover (Plantation) - Angle Degree - 90.00 OK
Tree Cover (Plantation) - Access Mt. - OK
Tree Tree - Nos Of Trees No. 4 6 OK
Car In Area Sq.Mt. - - 25.00 OK
Two Stack.Car In Area Sq.Mt. - - 25.00 OK
Total Car In Area Sq.Mt. 37.50 - 50.00 OK
Visitor's Car Parking In Area Sq.Mt. - - 12.50 OK
Total Visitor Parking In Area Sq.Mt. 12.50 - 12.50 OK
TwoWheeler In Area Sq.Mt. - - 4.00 OK
Two Stack. TwoWheeler In Area Sq.Mt. - - 4.00 OK
Total TwoWheeler In Area Sq.Mt. 8.00 - 8.00 OK
DriveWay PLOT - - - 4.50M WIDE DRIVEWAY - Width No. 3.60 - 4.50 OK
A-1 (SHAYESTA NIGAR) Front Margin... 18.20 mt. Wide MainRoad Mt. 3.00 - 6.10 OK
Rear Margin Mt. 1.80 - 4.00 OK
Side1 Margin Mt. 0.90 - 2.00 OK
Side2 Margin Mt. 0.90 - 2.00 OK
A-1 (SHAYESTA NIGAR) Basement Front Margin... 18.20 mt. Wide MainRoad Mt. 2.00 - 6.10 OK
Basement Rear Margin Mt. 1.80 - 4.00 OK
Basement Side1 Margin Mt. 0.90 - 2.00 OK
Basement Side2 Margin Mt. 0.90 - 2.00 OK

     Building Related Details
Name Description Unit Reqd Perm Proposed Status
A (SHAYESTA NIGAR) Height Mt. 30.00 9.45 OK
A (SHAYESTA NIGAR) Second Floor - Height Mt. 2.75 - 3.15 OK
Second Floor - Clear Height Mt. 2.75 - 3.03 OK
Second Floor - Beam Clear Height Mt. 2.40 - 2.78 OK
First Floor - Height Mt. 2.75 - 3.15 OK
First Floor - Clear Height Mt. 2.75 - 3.03 OK
First Floor - Beam Clear Height Mt. 2.40 - 2.78 OK
Ground Floor - Height Mt. 2.75 - 3.15 OK
Ground Floor - Clear Height Mt. 2.75 - 3.03 OK
Ground Floor - Beam Clear Height Mt. 2.40 - 2.78 OK
Basement Floor - Height Mt. 2.40 - 3.15 OK
Basement Floor - Clear Height Mt. 2.40 - 3.03 OK
Basement Floor - Beam Clear Height Mt. 2.10 - 2.78 OK
A (SHAYESTA NIGAR) Terrace Floor - Height Mt. - - 1.00 OK
A (SHAYESTA NIGAR) Basement Floor - Height Below GL Mt. - 2.25 OK
Basement Floor - Area Sq.Mt. - 89.51 OK
Basement Floor - Ventilation Area (Sq.mt.) Sq.Mt. - 1.80 OK
A (SHAYESTA NIGAR) Area Sq.Mt. - 89.51 OK
Status - OK
Total Area Sq.Mt. - 89.51 OK
A (SHAYESTA NIGAR) No. of Basement Floor No. 1 1 OK
A (SHAYESTA NIGAR) No. of Floors No. - 3 OK
No. of Tenements No. - 2 OK
A (SHAYESTA NIGAR) Number Of Lift(s) No. - 1 OK
Number Of Strature Lift(s) No. - - OK
Capacity Of Lift(s) Passanger No. - 6 OK
A (SHAYESTA NIGAR) BASEMENT FLOOR PLAN - Lift - Width Mt. 1.70 1.80 OK
BASEMENT FLOOR PLAN - Lift - Depth Mt. 1.90 1.90 OK
GROUND FLOOR PLAN - Lift - Width Mt. 1.70 1.80 OK
GROUND FLOOR PLAN - Lift - Depth Mt. 1.90 1.90 OK
TYPICAL - 1& 2 FLOOR PLAN - Lift - Width Mt. 1.70 1.80 OK
TYPICAL - 1& 2 FLOOR PLAN - Lift - Depth Mt. 1.90 1.90 OK
TERRACE FLOOR PLAN - Lift Machine Room - Width Mt. 1.70 2.15 OK
TERRACE FLOOR PLAN - Lift Machine Room - Depth Mt. 1.90 2.30 OK
BASEMENT FLOOR PLAN STAIRCASE - Flight Width Mt. 0.900 0.900 OK
STAIRCASE - Tread Width Mt. 0.250 0.250 OK
STAIRCASE - Riser Height Mt. 0.200 - OK
STAIRCASE - Riser No. On Flight No. - - OK
STAIRCASE - Cabin Ht. Mt. - - - OK
GROUND FLOOR PLAN STAIRCASE - Flight Width Mt. 0.900 0.900 OK
STAIRCASE - Tread Width Mt. 0.250 0.250 OK
STAIRCASE - Riser Height Mt. 0.200 0.143 OK
STAIRCASE - Riser No. On Flight No. - 11 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
TYPICAL - 1& 2 FLOOR PLAN STAIRCASE - Flight Width Mt. 0.900 0.900 OK
STAIRCASE - Tread Width Mt. 0.250 0.250 OK
STAIRCASE - Riser Height Mt. 0.200 0.143 OK
STAIRCASE - Riser No. On Flight No. - 11 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
TERRACE FLOOR PLAN STAIRCASE - Flight Width Mt. - 0.900 OK
STAIRCASE - Tread Width Mt. - 0.250 OK
STAIRCASE - Riser Height Mt. - - OK
STAIRCASE - Riser No. On Flight No. - - OK
STAIRCASE - Cabin Ht. Mt. - - 2.525 OK
Toilet Area Sq.Mt. - 5.00 1.44 OK
Width Mt. - - 1.20 OK
Depth Mt. - - 1.20 OK
Height Mt. - - - OK
SEPTIC TANK Area Sq.Mt. - - 1.86 OK
Width Mt. - - 0.99 OK
Depth Mt. - - 1.88 OK
Height Mt. - - - OK
RAIN WATER HARVESTING Area Sq.Mt. - - 1.86 OK
Width Mt. - - 0.99 OK
Depth Mt. - - 1.88 OK
Height Mt. - - - OK
ENT.GATE Area Sq.Mt. - - 0.56 OK
Width Mt. - - 0.13 OK
Depth Mt. - - 4.51 OK
Height Mt. - - - OK
GUARD ROOM Area Sq.Mt. - 10.00 4.32 OK
Width Mt. - - 1.80 OK
Depth Mt. - - 2.40 OK
Height Mt. - - - OK
Entrance Lobby Area Sq.Mt. - 12.00 3.33 OK
Width Mt. - - 1.80 OK
Depth Mt. - - 1.85 OK
Height Mt. - - - OK
Area Sq.Mt. - 12.00 3.33 OK
Width Mt. - - 1.80 OK
Depth Mt. - - 1.85 OK
Height Mt. - - - OK
Area Sq.Mt. - 12.00 3.33 OK
Width Mt. - - 1.80 OK
Depth Mt. - - 1.85 OK
Height Mt. - - - OK
SOLAR HEATING SYSTEM Area Sq.Mt. - - 1.86 OK
Width Mt. - - 0.99 OK
Depth Mt. - - 1.88 OK
Height Mt. - - - OK
A (SHAYESTA NIGAR) Rain Water Harvesting - No No. 1 - 1 OK
   
    All Rooms are as per Rule in Room Checking




[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Width No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Depth No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Access Width The minimum width of abutting road for any Building shall be with respect to Length of Road {As per Rule No. 34 Table No.6}
Plot Frontage No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
FAR Area (1) In Old Area, for Non-Residential Building on abutting roadwidth 12.20 (40 ft.) to 18.30 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15}
(2) For Madhupur Nagar Parishad, Max. 2.0 permissible FAR may be permitted for Commercial or Mercantile type Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Non-Residential Building on abutting roadwidth 12.20 (40 ft.) to 18.30 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15}
(2) For Madhupur Nagar Parishad, Max. 2.0 permissible FAR may be permitted for Commercial or Mercantile type Use {As per Annexure III}
Common Plot Area In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
Common Plot (1) ; In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
(2) ;
(3) In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
(4) ;
Tree Number 4-8 Trees shall be required for the Plot area above 250.0 and upto 1000.0 sq.mt. (As per Rule No. 20.1.6)
DriveWay Rule For Plor area upto 2000 sq.mt., the minimum width or driveways should not be less than 3.60 mt. {As per Rule No. 41.2 and modified as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
Margin Rule For Non-highrise Residential Building upto 10.0 mt. Ht. having Plot Depth 21-27 mt. and Plot width 10-15 mt., Margin required in Front shall be 3.0 mt., Rear 1.8 mt. and 0.9 mt. shall be provided on both side. {As per Rule No. 36 (Table 8 & 9)}
Basement Margin Rule In case of apartment/ group housing/commercial building and basements may be allowed to be constructed under the entire plot area leaving mini. 2 mt. space from the boundary of the premises {As per Rule No. 48}
Building Level
Building Height For old area, on Road width 12.20-18.30 mt., Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 30.0 mt. {As per Rule No. 39.1 Table 15}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(3) o Every basement shall be in every part at least 2.4 m. in height from the floor to the soffit of the roof slab or ceiling and mini. Of 2.1 mr. below the soffit of beams {As per Rule No. 48}
Parapet Height Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
Below GL Floor Height ,
Basement Floor No. Individual residential and small commercial buildings, plot size upto minimum 750 Sq. Meter may have one basement {As per Rule No. 48}
Floor Number For old area location,on Road width 12.20-18.30 mt., Maximum Height 30 meter shall be allowed. {As per Rule No. 39.1 Table 15}
Lift Count (1) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(2) For Residential Building height upto 15.0 mt or upto G+4 floors, No Lift is reqd. {As per Amended 06-06-2019 Rule No. 49.1.1}
Lift (1) The area of lift well shall not be counted for F.A.R calculation)
(2) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(3) The area of lift well at one floor only (not the sum of total area of lift well at every floor) shall be counted for F.A.R calculation)
(4) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(5) -
StairCase (1) Width of Winding staircase shall be mini. 0.90 mt.,Maximum rise 0.20 mt. & Minimum tread 0.25 mt. & Cabin Height 2.1 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) No Rule Defined
(4) ; No Rule Defined
Plot / Building Level
Accessory Use (1) Common toilet of maximum size of 5 sq.mt shall be taken Free from FAR
(2) No need to check distance from Building Toilet
(3) -
(4) No need to check distance from Building SEPTIC TANK
(5) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(6) No need to check distance from Building RAIN WATER HARVESTING
(7) No need to check distance from Building ENT.GATE
(8) Guard room of max. 10 sq.mt. maximum size of 5 sq.mt shall be taken Free from FAR
(9) No need to check distance from Building GUARD ROOM
(10) Entrance Lobby of maximum size of 12 sq.m. shall be taken Free from FAR
(11) No need to check distance from Building Entrance Lobby
(12) -
(13) No need to check distance from Building SOLAR HEATING SYSTEM
Accessory Use Number Provision of Rain Water Harvesting shall be mandatory for any use {Updated as per JBBL, Amendment VIII dated 16/03/2021} Rain Water Harvesting
Building Level (Rooms)