No Image Found   

Check List Report

Madhupur Nagar Parishad

Version Number: 1.0.66  
Version Date: 16/10/2020 
Report Generated On: 04-10-2023 
 

[-] Collapse All


General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictDEOGHAR
AuthorityMADHUPUR NAGAR PARISHAD
Inward_NoMNP/BP/0027/W03/2023
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentNew
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillageSapha
Taluka18
Architect Details
Architect NameVISHAL YADAV
License No.MNP/ENG/0006/2020
Architect AddressDANGAL PARA ROAD, MADHUPUR, DEOGHAR -815353 JHARKHAND
Architect EmailIDvishalyadav0209@gmail.com
Architect Mobile No9122638843
Plot Details
Plot Use Medical
Plot SubUse Lab
PlotNearbyReligiousStructure NA
Plot/SubPlot No0/1
NorthRoad Width - 18.2
SouthPlot No. - VENDORS LAND
EastPlot No. - VENDORS LAND
WestPlot No. - VENDORS LAND
Owner's Details
NameINTERNATIONAL HOMOEO RESEARCH LABORATORY
Address52 BIGHA SAPAHA
Email IDSmitakar263@gmai.com
Mobile No9830671338
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 4912.40
2 Plot area as per Document by Applicant 4912.40
3 Physical area measured at site 4912.00
4 Area as per Site Visit (Site Visit Report) 4912.00
5Area as per Drawing 4911.82

Area of Plot Considered : 4911.82

[-] Table 2b
Proposal Detail :
Unit
Development Detail :
PlotPLOT
Plot OccupancyMedical
Plot SubUse Lab
Building StructureNon-Highrise
Building TypeSingle Detached House
Gross Plot Area 4911.82
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 4911.82
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 4219.42
Deductions for Balance Plot Area (from Gross Plot Area)
- Common Plot 692.40
692.40
Balance Plot Area 4219.42

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 50.00 % ) 2455.91
Proposed Coverage Area ( 6.89 % ) 338.57
Total Prop. Coverage Area ( 6.89 % ) 338.57
Balance coverage area ( 43.11 % ) 2117.34
FAR CHECK
Perm. FAR Area ( 2.000 ) 9823.64
Total Perm. FAR area 9823.64
Special FAR 490.47
Proposed FAR Area 490.47
Total Proposed FAR Area 490.47
Consumed FAR (Factor) 0.10
Balance FAR Area 9333.17
BUA CHECK
Total Proposed BuiltUp Area 490.47


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Exceeding 50 meter and upto 100 meter -
Existing Road Width 18.2 18.20
Proposed Road Width as per Master Plan 18.2 -
Road Widening Width 0 -
Plot size (as per measurement) 4912 4911.82
[-] Extra Land Area Checks
Name Area Status
Reqd Prop
Extra Land - 0.00 OK

     Extra Land Area Details
Name Description Unit Reqd Perm Proposed Status
Extra Land Area Details Extra Land Area - - 0.00 OK

     Plot Related Details
Name Description Unit Reqd Perm Proposed Status
PLOT Plot Area Sq.Mt. - - 4911.82 OK
Plot Width Mt. - - 61.42 OK
Plot Depth Mt. - - 79.97 OK
Access Width Mt. 9.00 - 18.20 OK
Plot Frontage Mt. - - 61.42 OK
Coverage Area Sq.Mt. - 2455.91 338.57 OK
FAR Area Sq.Mt. - 9823.64 490.47 OK
Consumed FAR Sq.Mt. - 2.00 0.10 OK
Common Plot Checks Common Plot - Total Area Sq.Mt. 245.59 692.40 OK
Common Plot Tree Cover (Plantation) - Minimum Area Sq.Mt. - 692.40 OK
Tree Cover (Plantation) - Coverage Area Sq.Mt. - - OK
Tree Cover (Plantation) - Width Mt. - 9.41 OK
Tree Cover (Plantation) - Angle Degree - 90.00 OK
Tree Cover (Plantation) - Access Mt. - OK
Tree Tree - Nos Of Trees No. 8 44 OK
Car In Area Sq.Mt. - - 212.50 OK
Total Car In Area Sq.Mt. 12.50 - 212.50 OK
TwoWheeler In Area Sq.Mt. - - 26.00 OK
Total TwoWheeler In Area Sq.Mt. - - 26.00 OK
A-1 (COMMERCIAL) Front Margin... 18.2 METER WIDE MAIN ROAD Mt. 6.50 - 55.51 OK
Rear Margin Mt. 4.50 - 5.00 OK
Side1 Margin Mt. 4.50 - 18.59 OK
Side2 Margin Mt. 4.50 - 21.08 OK

     Building Related Details
Name Description Unit Reqd Perm Proposed Status
A (COMMERCIAL) Height Mt. 30.00 6.86 OK
A (COMMERCIAL) First Floor - Height Mt. 2.75 - 3.30 OK
First Floor - Clear Height Mt. 2.75 - 3.18 OK
First Floor - Beam Clear Height Mt. 2.40 - 3.05 OK
Ground Floor - Height Mt. 2.75 - 3.56 OK
Ground Floor - Clear Height Mt. 2.75 - 3.43 OK
Ground Floor - Beam Clear Height Mt. 2.40 - 3.30 OK
Plinth - Height Mt. 0.45 - 0.71 OK
Plinth - Clear Height Mt. - - 0.71 OK
Plinth - Beam Clear Height Mt. - - 0.71 OK
A (COMMERCIAL) Terrace Floor - Height Mt. - - 0.75 OK
Terrace Floor - Clear Height Mt. - - 0.75 OK
Terrace Floor - Beam Clear Height Mt. - - 0.75 OK
A (COMMERCIAL) No. of Floors No. - 2 OK
No. of Tenements No. - 2 OK
GROUND FLOOR PLAN STAIRCASE - Flight Width Mt. 0.750 1.156 OK
STAIRCASE - Tread Width Mt. 0.225 0.254 OK
STAIRCASE - Riser Height Mt. 0.200 0.137 OK
STAIRCASE - Riser No. On Flight No. - 13 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
FIRST FLOOR PLAN STAIRCASE - Flight Width Mt. 0.750 1.156 OK
STAIRCASE - Tread Width Mt. 0.225 0.254 OK
STAIRCASE - Riser Height Mt. 0.200 0.127 OK
STAIRCASE - Riser No. On Flight No. - 13 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
TERRACE FLOOR PLAN STAIRCASE - Flight Width Mt. - 1.156 OK
STAIRCASE - Tread Width Mt. - 0.254 OK
STAIRCASE - Riser Height Mt. - - OK
STAIRCASE - Riser No. On Flight No. - - OK
STAIRCASE - Cabin Ht. Mt. 2.100 - 2.641 OK
SUMP TANK Area Sq.Mt. - - 50.00 OK
Width Mt. - - 5.00 OK
Depth Mt. - - 10.00 OK
Height Mt. - - - OK
RAIN WATER HARVESTING Area Sq.Mt. - - 48.00 OK
Width Mt. - - 6.00 OK
Depth Mt. - - 8.00 OK
Height Mt. - - - OK
Overhead WaterTank Area Sq.Mt. - - 0.78 OK
Width Mt. - - 1.00 OK
Depth Mt. - - 1.00 OK
Height Mt. - - - OK
Area Sq.Mt. - - 0.78 OK
Width Mt. - - 1.00 OK
Depth Mt. - - 1.00 OK
Height Mt. - - - OK
Area Sq.Mt. - - 0.78 OK
Width Mt. - - 1.00 OK
Depth Mt. - - 1.00 OK
Height Mt. - - - OK
ENT.GATE Area Sq.Mt. - - 1.25 OK
Width Mt. - - 0.25 OK
Depth Mt. - - 5.00 OK
Height Mt. - - - OK
GUARD ROOM Area Sq.Mt. - 10.00 6.00 OK
Width Mt. - - 2.00 OK
Depth Mt. - - 3.00 OK
Height Mt. - - - OK
SOLAR HEATING SYSTEM Area Sq.Mt. - - 2.85 OK
Width Mt. - - 1.36 OK
Depth Mt. - - 2.09 OK
Height Mt. - - - OK
A (COMMERCIAL) Rain Water Harvesting - No No. 1 - 1 OK
   
    All Rooms are as per Rule in Room Checking




[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Width No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Depth No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Access Width The minimum width of abutting road for Institutional, administrative, assembly, industrial and other Nonresidential and commercial activities shall be 9.0 mt.{As per Rule no. 34.5 and modified as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
Plot Frontage No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
FAR Area (1) In Old Area, for Non-Residential Building on abutting roadwidth 12.20 (40 ft.) to 18.30 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15}
(2) For Madhupur Nagar Parishad, Max. 2.0 permissible FAR may be permitted for Commercial or Mercantile type Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Non-Residential Building on abutting roadwidth 12.20 (40 ft.) to 18.30 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15}
(2) For Madhupur Nagar Parishad, Max. 2.0 permissible FAR may be permitted for Commercial or Mercantile type Use {As per Annexure III}
Common Plot Area In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
Common Plot (1) In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
(2) ;
Tree Number Mini. 8 Trees shall be required for the Plot area above 1000.0 sq.mt. (As per Rule No. 20.1.6)
Margin Rule For Multistoried Building, having Building Height 16.40-19.25 mt.,Margin required in Front shall be 6.5 mt., Rear 4.5 mt. and 4.5 mt. shall be provided on both side. {As per Rule No. 37 Table 14}
Building Level
Building Height For old area, on Road width 12.20-18.30 mt., Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 30.0 mt. {As per Rule No. 39.1 Table 15}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(3) The plinth or any part of a building shall be so located with respect to the surrounding ground level that adequate drainage of the site is assured. The height of the plinth (except in case of stilted parking) shall be not less than 0.45 mt. from the surrounding ground level {As per Rule No. 42.10}
Parapet Height (1) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
(2) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
(3) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
Floor Number For old area location,on Road width 12.20-18.30 mt., Maximum Height 30 meter shall be allowed. {As per Rule No. 39.1 Table 15}
StairCase (1) Width of Winding staircase shall be mini. 0.75 mt.,Maximum rise 0.20 mt. & Minimum tread 0.225 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) Width of Winding staircase shall be mini. 0.75 mt.,Maximum rise 0.20 mt. & Minimum tread 0.225 mt. & Cabin height 2.1 mt {As per Rule No. 83.18}
(4) ; No Rule Defined
Plot / Building Level
Accessory Use (1) -
(2) No need to check distance from Building SUMP TANK
(3) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(4) No need to check distance from Building RAIN WATER HARVESTING
(5) -
(6) No need to check distance from Building Overhead WaterTank
(7) No need to check distance from Building ENT.GATE
(8) Guard room of max. 10 sq.mt. maximum size of 5 sq.mt shall be taken Free from FAR
(9) No need to check distance from Building GUARD ROOM
(10) -
(11) No need to check distance from Building SOLAR HEATING SYSTEM
Accessory Use Number Provision of Rain Water Harvesting shall be mandatory for any use {Updated as per JBBL, Amendment VIII dated 16/03/2021} Rain Water Harvesting
Building Level (Rooms)